1. Monitors up to 8 Digital inputs amp 4 Analogue inputs 8 Remote control outputs for switching applications Fast and easy installation Low set up and running costs No field programming required as it can be done by SMS Faster response to alarms and process disturbances Able to work in GSM mode or GPRS mode e Programmable 4 alarm set points for each analogue input Works with 0 5VDC or 4 20mA based transducer e Accept other kind of sensors temperature sensor motion sensor etc Reports on set point alarms and other triggers Real time monitoring amp controlling via monitoring software Reduces wasted traveling time responding to alarm events Provides more detailed information 3 CHARACTERISTIC WT 9001 is a versatile SMS alert device suited for most monitoring needs It is simple to use yet is packed with powerful functionalities to meet a wide ranging industrial and commercial and residential applications WT 9001 I P65 USER MANUAL Rev 4 1 Technical Support technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD ng amp Remote Control System 3 1 Standalone Operation Housed in the weather and desk proof IP 65 enclosure complete with internal industrial modem monitoring controller and flexible operating firmware It is very easy to setup install and use 3 2 8 Digital Inputs Most equipment today does provide some form of alerting signal to interface to mo
2. sisseeles mmm emen O1 5 2 Access Control for Administrator eeesieeesesese menn nnd T 5 9 QPU S BIEIDICIS ss ne eee ete eee a bret Sacoche lid op INDUL CUN RT 59 Alarm Seting mem 20 GPRS SENOS erre a O a 2 O 5 7 Miscellaneous Settings cscsisisiseeees esee mmemmememimimimiminsusururatninis i DO 6 Technical SPEC CallONS TETTE WT 9001 I P65 USER MANUAL Rev 4 1 Technical Support technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD 1g amp Remote Control System 1 INTRODUCTION The WT9001 IP65 GSM Remote Monitoring amp Remote Control System is a complete remote telemetry unit It contains a GSM Modem and control circuitry It is capable of controlling up to 8 Relay outputs and monitor 8 Digital inputs and 4 Analogue inputs Analogue input support Detect Water Leaks Monitor Temperatures for out of range conditions Monitor Humidity for Damaging High Humidity Levels and monitor fuel levels The WT9001 IP65 GSM Remote Monitoring amp Remote Control System is operated by the sending of SMS GPRS and email The GSM controller can be used as a remote telemetry system users can directly control the output relays from a simple text message or GPRS The controller can also be used as a remote monitoring system the unit can automatically notify the user whenever the any inputs change state The WT 9001 IP65 is complete with an LCD display back up battery and built in Quad Band Modem
3. VT 9001 IP65 GSM Remote Monitoring And Remote Control System User Manual amp Setting Instructions UNTURA TURA CORPORATION SDN BHD not Control System WIRING DIAGRAM DESCRIPTION Auxiliary 12 VDC Output Auxiliary DC Output Depends on power supply Auxiliary 12VDC Output RLY8 N O Ma Descriptions INPUT POWER 15 24VDC RLY M O p a ES Auxiliary 12VDC Output S RLY6 N O IDEE e RLYS N o EX Auxiliary DC Output Depends on power supply z E LEL RLY4 N O EZ Auxiliary 5VDC Output INE ONE een RLY3 N O Pulse Counter amp E Auxiliary 3 3VDC Output Digital function GND aa W O EST ST Ie EN Analogue Input 4 Digital function e SIREN GND GND GND GND GND GND GND tS ES c5 IS OSGFSPLPORFSPFRRFEFERPIPFORG EE RN 67B 9 10 11 12 13 1415 lb 17 15 19 2021 De DS Db BS Ply 27 2A 29 NU NBNSN KMESIESESESBSSS WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD trol System CONNECTION DETAILS Example Commection Diagram of 0 5 4 5 IC Fuel Sensors Auxiliary 12VDC Output Auxiliary 12VDC Output Auxiliary OC Output Depends on Power Supply Auxiliary 5VDXC Output Auxiliary 3 3VDC Output GND GND GND GND GND GND GND GND GND 16171619 20 21 22 23 2425 21 27 21 29 31 L j 6 9 10 1112131415 WO ONSSSESSSS NS BSINSYNEVENOSVSNON RE 0 5 4 5VDC Anal
4. 1 Function as Analogue Input Measure 0 5VDC Signal for voltage based transducer fuel sensor Working Mode 2 Function as Analogue Input Measure 4 20mA Signal for current based transducer Fuel sensor Working Mode 3 Function as Analogue Input for temperature 5VDC Working Mode 4 Function as Analogue Input for humidity 5VDC Example To configure input 1 to monitor a 4 20mA input signal you would send the following SMS message to the unit SWT17 2 Note Loop voltage of 5VDC and 12VDC output is included on board to provide power for up to four 0 5VDC sensors or 4 20mA sensors A maximum of 24VDC is allowed to be connected to the inputs 5 4 3 Setting the Alarm Set Points for Analogue Input Note This Function Works On Analogue I nput Only There are 4 alarm set points available on each analogue input It allows the unit to generate alarms whenever the monitored signal reaches the set point To program the alarm set points you can send the following command by SMS to the unit Text Command WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com l4 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD emote Control System ALP N I XX F N stands for input number 1 4 stands for set point number 1 4 XXX stands for 2 digits Percentage Threshold Alert Value for Alarm F stands for the perform functions Selectable O 10 Selectable Functions F Description Function
5. N stands for number 5 12 of Input XXXXX stands for the display text that you want to program Maximum 50 characters Example If you want the alert message to display Garage Closed when input 1 triggered you would send the following SMS message to the unit STO1ZGarage Closed To check the programmed texts you can send STO Z N 5 4 10 Setting the Counter Alert Value For I nputs Note Only Input 5 8 have pulse counter function An alert message will be sent when the increment of alarm counter reaches the alert value Default 500 It is possible to set the alert value up to maximum value of 9999999 times To set the counter alert value of input you can send the following commands by SMS message to the unit Text Command COA N ZX N stands for number 5 8 of Input X stands for the number of times Range from 0 9999999 Example Assume that you want it to send a counter alert message each time the input 5 has triggered for 5 times you would send the following SMS message to the unit COA5 5 WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 19 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD amp Remote Control System 5 4 11 Setting the Feature Of Digital I nput All digital inputs can be programmed to behave differently it can count the input active high pulses generate an alarm message or activate relay To program the input you can send the following co
6. and off Eg If pulse counter 4 at Digital Input 8 reached the alert value relay 4 will activate Generates an alert message once alarm counter reaches the alert value Audible alarm will sound once alarm counter reached the alert value if the alarm function is turned on ALM N 1 Function 5 E Digital Input Mode Activates the output relay number according to which input number applied with functions of PWT N and PWK N Not repeatingly 2 times then stop afterwards Generates a programmable input alert message STR N once input triggered For more details on functions of PWT N and PWKI N please refer to Miscellaneous Settings on page Function 6 e Function as pulse counter E Activates the output relay number according to which input number applied with functions of PWT N Z and PWK N Not repeatingly 2 times then stop afterwards E Generates an alert message once alarm counter reaches the alert value e Audible alarm will sound once alarm counter reached the alert value if the alarm function is turned on ALM N 1 For more details on functions of PWT N and PWKI IN Z please refer to Miscellaneous Settings on page Function 7 e Digital Input Mode e Generates a programmable input alert message STR N once input triggered Function 8 e Digital Input Mode Generates a programmable input alert message STR N once input triggered e Generates a programmable input aler
7. reaches the programmable set points Four programmable set points can be programmed for each analogue input When the monitored signal crosses a set point a specified action will be performed like switching the output relay or sending an SMS report WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD toring amp Remote Control System 3 4 8 Digital Outputs WT 9001 is a 2 way device Besides monitoring inputs and act upon such inputs it also allow mobile phone users to compose SMS messages to it When WT 9001 receives any SMS it will look its memory bank to see what it is supposed to do and action according No action SMS are ignored Up to 8 relays can turned on and off by messages received from mobile phone Creating action messages are done with the same ease as that of input monitoring 3 5 Querying Inputs And Outputs Status Authorized groups can also query the status of an input or output This is very useful feature to determine the present status of an input or output The enquirer need not wait for an alarm to happen in order to receive the given I O status 3 6 Turning On Off Device Remotely Authorized users can send a SMS command to trigger on or off the digital output Upon receiving the command WT 9001 will perform the instructed action After the on or off action is done it will send a reply to the querying mobile phone as an ackn
8. send the following SMS message to the unit RER2Z 32222000000000000000 Example of Returned Message RER2 32222000000000000000 OK To check the setting you can send the following SMS command to the unit RER 5 4 8 Editing the Input Alert Message For When Input gets High Pulse The Input Alert Message can be edited and programmed up to 50 characters long You can change the displayed text by sending the following commands by SMS message to the unit Note Only support normal abc ABC English text no special characters Text Command STR N XXXXX N stands for number 5 12 of Input XXXXX stands for the display text that you want to program Maximum 50 characters Example If you want the alert message to display Garage Opened when input 1 triggered you would send the following SMS message to the unit STR1 Garage Opened To check the programmed texts you can send STR Z N WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 19 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD 1g amp Remote Control System 5 4 9 Editing the Input Alert Message For When Input returned to Normal The Input Alert Message can be edited and programmed up to 50 characters long You can change the displayed text by sending the following commands by SMS message to the unit Note Only support normal abc ABC English text no special characters Text Command STOIN ZXXXXX
9. sound the connected audible siren when input triggered This output is available on the connection PIN6 and ground on the main board To turn On Off this function you can send the following SMS command to the unit Text Command ALMIN ZX WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 23 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD ng amp Remote Control System N stands for Input number 1 12 X stands for ON 1 or OFF 0 value When ALM1 1 is applied means audible alarm will sound when Input 1 triggered When ALM1 0 Default is applied means audible alarm will not sound when Input 1 triggered To check the audible siren function setting you can send ALM Z N 5 5 2 Setting the Alarm Time For Audible Alarm Default 600 seconds The alarm siren can be set to determine how long the siren will remain active and this can be done by sending the following SMS command to the unit Text Command ALTM X X stands for the number of seconds Range from 0 9999999 Example When ALTM 3600 is applied means the audible alarm will sound for 1 hour when triggered To check the Alarm time setting you can send ALTM 5 5 3 Power Down Alarm The system has the function to send a text alert and also sound the audible siren in the event the main power is lost and the system is relying on battery back up It is also possible to activate and deactivate this function by sen
10. the system will be rejected To allow any person gain access to the system just send SMS Command ANY O Note Only Administrator number 1 and 2 may send this SMS command 5 3 OUTPUT Settings The WT 9001 has 8 outputs that are connected to an on board relay which can be activated by sending an SMS command 5 3 1 Switch On the Output Relay For a Specific Time To activate any output relay you can send a text command via SMS specifying the output number and the number of seconds the output should stay on to the unit It is possible to set up to maximum of 99 999 seconds Text Command RLY N X N stands for Output number 1 8 X stands for the number of seconds Range from O 999999 Example To turn on the output relay number 5 for 1 hour you can send the following text message to the unit RLY5 3600 Example of Returned Message RLY5 3600 OK WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com ll COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD ing amp Remote Control System Note Sending the following SMS Message to unit will switch off the relay RLY5 0 To check the status of all the relays you would send the following text message to the unit RLY 5 3 2 Switch Multiple Outputs Relays to Stay On To activate multiple output relays to stay on you can send a text command via SMS specifying the output number that should stay on to the unit Text Comma
11. who hijacks the WT 9001 device It allows the owner to identify the hijacker s SIM Card number by sending a warning message to the programmed owner s number when the SIM card has been switched To activate and also deactivate this function you can send the following SMS command to the unit Text Command ANTH X X stands for ON 1 or OFF 0 value When ANTH 1 is applied means it will alert the owner by sending a warning message when the SIM Card has been changed When ANTH ZO Default is applied means this function is turned off WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 25 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD tor ng amp Remote Control System Alert message received WARNING SIM Card Has Been Changed On WT 9001 To check the Anti Theft setting you can send ANTH 5 5 6 Setting the Recipient of Anti Theft Alert With Anti Theft function turned on it can generate text alerts to all 20 of the administrator s Mobile phone numbers whenever the SIM card has changed To set the administrator to receive this alert you would send the following commands by SMS message to the unit Text Command REAT XXXXXXXXXXXXXXXXXXXX X stands for position for 1 20 administrators with function value O OFF 1 9 number of text alerts Example When SIM card has been changed it will generate 3 SMS to administrators 1 2 3 and 1 SMS to the rest you would send th
12. you can send GSI P 5 6 4 Turn On the GPRS Connection To activate the GPRS connection of the SIM card you can send the following SMS command the unit Default Off Text Command GPRS X X stands for ON 1 or OFF 0 Example To turn on GPRS connection you would send the following SMS command to the unit GPRSZ1 Note It is advised that you should program all other functions before enabling the GPRS connection When enabled it will not send any SMS messages To check GPRS connection setting you can send GPRS WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 28 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD ng amp Remote Control System 5 7 MISCELLANEOUS SETTINGS 5 7 1 Inquire All Programmed Administrator Numbers To check all the administrator number in the list simply send the following SMS command Text Command ADM 5 7 2 Inquire the Status of I nputs To check input status you can send the following SMS command Text Command CTR If all inputs are disabled the returned message would be ANI N1 OFFZANI N2 0FF ANI N3 0FF ANI N4 0FF 1 NDI G5 0FF 1 NDI G6 OFF I NDI G7 OFF I NDI G8 OFFZI NDI G9 OFFZI NDI G10 0FF INDIG11 OFFZI NDI G12 0FF If analog inputs are ON input5 in counter mode input6 9 in digital mode the rest are OFF the returned message would be ANIN1 ONZANIN2 ONZANIN3 ON ZANINA4 ONZINCTR5 ONZINDI G6 0N ZINDIG7 zONZINDIG8
13. z0ON ZINDI G9 ONZINDIGI0 ZOFFZI NDIG11 OFFZIN DI G12 OFFZ 5 7 3 Reading Counter Alert Value Of Inputs It is possible read all the counter alert value of inputs by sending the following SMS command to the unit Send the following SMS Command COA Example of Returned Message COA5 XXX COA6 XXX COA7 XXX COA8 XXX XXX stands for the number of seconds Range from 0 9999999 WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 29 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD itoring amp Remote Control System 5 7 4 Reading the Alarm Time Value It is possible to read the alarm time value by sending the following SMS command to the unit Send the following SMS Command ALT Example of Returned Message ALT 30 OK Note All 8 Digital Inputs have the same setting for siren on time Default 30 sec 5 7 5 Reading the Total I ncrement Counter Value To read the total increment counter value you can send the following SMS message to the unit Text Command COU Example of Returned Message INC5 x xxx INC6 x xxx INC7zx xxx INC8 x xxx OK Note This Function Works On Digital Input 5 8 only 5 7 6 Reading the Sub Increment Counter Value p To read the sub increment counter value you can send the following SMS message to the unit Text Command COT Example of Returned Message PULSE5 x PULSE6 x PULSE7 x PULSE8 x OK Note If pulse
14. 800 1900mhz Humidity Less Than 90 RH Operating Temperature 08 C to 80 C Security Features Password protected access and phone number checks System Health Check Remote health check feature via SMS Indicators Power Telco Network Signal Low Other error Repeat SMS of alarms User configurable I O Interface 3 8mm pitch pluggable screw terminal block Remote event log Yes Output pulse capability Yes Display Dot Matrix LCD with back light 16 characters x 2 line WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 34 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD Monitoring amp Remote Control System WARRANTY Witura Corporation Sdn Bhd guarantees all WT 9001 IP65 GSM Remote Monitoring And Remote Control System against defective parts and workmanship for 1 year warranty Witura Corporation Sdn Bhd shall at its option repair or replace the defective equipment upon the return of such equipment to any Witura branch This warranty applies ONLY to defects in components and workman ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment Note Wherever possible return only the PCB to Witura Service Centres DO NOT return the enclosure The WT 9001 IP65 is a product of Witura Corporation Sdn Bhd and is manufactured by Shenz
15. HD itoring amp Remote Control System Text Command TEST When the unit replies TEST OK indicate the unit is operating correctly Note If you receive no reply then unit is not working 5 7 11 Setting the Password for Reset Command To setup a password for reset command you can send the following SMS command to the unit Text Command PAWO XXXXXX XXXXXX stands for 6 digits password 123456 Default Example To change the password to 654321 you would send the following SMS command to the unit PAWO 654321 5 7 12 Reset the WT 9001 To reset the unit you can send the following SMS command to the unit Text Command RESTZXXXXXX XXXXXX stands for 6 digits password based on PAWO Default 123456 and it can be changed anytime To reset manually via hardware just press the tact switch button 5 7 13 Saving Parameters To save parameters into the EEPROM you can send the following SMS command to the unit Text Command SAVE2PROMZ WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 32 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD litoring amp Remote Control System 5 7 14 Checking the Back up Battery Status To check the battery voltage and charger status you can send the following SMS command to the unit Text Command CHARGER 5 7 15 Checking the Software and Hardware Version of WT 9001 To check the software and hardware ve
16. O e No Function Function 1 e Activates output relay 5 to stay on Function 2 e Activates output relay 6 to stay on Function 3 e Activates output relay 7 to stay on Function 4 e Activates output relay 8 to stay on Function 5 e Sends a programmable alert message SDF N Function 6 e Sends a programmable alert message SDF N and activates audible alarm Depends on function ALM Function 7 e Turn off output relay 5 The unit will send SMS if the relay 5 is ON at previous state If not it won t send SMS Function 8 e Turn off output relay 6 The unit will send SMS if the relay 6 is ON at previous state If not it won t send SMS Function 9 e Turn off output relay 7 The unit will send SMS if the relay 7 is ON at previous state If not it won t send SMS WT 9001 I P65 USER MANUAL Rev 4 1 Technical Support technical witura com 15 COPYRIGHT 2010 WITURA CORPORATION SDN BHD 1g amp Remote Control System Function 10 e Turn off output relay 8 The unit will send SMS if the relay 8 is ON at previous state If not it won t send SMS Example To setup 2 alarm set points at 10 and 90 for input 1 and both set points will also trigger an alarm message you would send the 2 following SMS command to the unit ALP11 10 3 ALP12 90 3 Note The perform functions work on GSM mode only 5 4 4 Editing the Alarm Set Point Message Content Note This Function Works On Analogue I
17. d Text Command ANETZXXXXX Username Password XXXXX stands for Access Point Name Maximum 15 characters Username maximum 10 characters Password maximum 15 characters Example To configure the access point Vodanet user name 123 and password 123 you can send the following text message to the unit ANETZVodanet 123 123 Note If there is no user name and password required for GPRS connection you can simply send the command as the following ANET Vodanet To check the APN settings you can send ANET Z WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 27 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD 1g amp Remote Control System 5 6 3 Setup the GPRS Communication To link the WT 9001 unit to the monitoring software you will need to program the connection type external IP address of the host computer and Port number created from the monitoring software into the WT 9001 unit by sending the following SMS command Text Command GSIP TTT XXX XXX XXX XXX NNNN TT stands connection type TCP XXX XXX XXX XXX stands for Public IP Address NNNN stands for Local Port number created from the WT 9001 Monitoring Software Example Assume that you have acquired the External IP address as 123 65 214 231 port number 8765 and connection type TCP you would send the following SMS command to the unit GSIPZTCP 123 65 214 231 8765 To check GPRS communication settings
18. ding the unit an SMS Message Text Command ALACZX X stands for ON 1 or OFF 0 value When ever the ALAC 1 command is activated and the power down alarm is on any of the Administrators programmed to receive text alerts will receive the following messages from the unit in the event of power down and also when power is restored WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 24 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD ig amp Remote Control System Power down and text alert received Power down Power restored and text alert received Power restored 5 5 4 Setting the Recipient of AC Failure Alert Whenever there is power failure the unit can generate text alerts to all 20 of the administrator s Mobile phone numbers To set the administrator to receive this alert you would send the following commands by SMS message to the unit Text Command REAC XXXXXXXXXXXXXXXXXXXX X stands for position for 1 20 administrators with function value O OFF 1 9 number of text alerts Example To generate 2 SMS to administrators 1 2 3 and 1 SMS to the rest when AC failure you would send the following SMS message to the unit REACZ22211111111111111111 Example of Returned Message REAC 22211111111111111111 To check the setting for AC failure alert you can send REAC 5 5 5 Anti Theft Feature The system has an anti theft function that can used to detect the person
19. e this function you must turn on the function of the inputs and tell the WT 9001 which are the recipient numbers and who should receive the alert message for the particular input 5 4 1 Turn On the Function of Inputs To turn on the function of input you can send the following commands by SMS message to the unit Text Command CTR N X N stands for number 5 12 of Input X stands for ON 1 or OFF 0 value Example To turn on input number 1 you can send the following text message to the unit CTR5 1 Returned Message INCTR5 0N OK To disable input 1 you would send the following SMS to the unit CTR5 0 Returned Message 1 NCTR5 OFF OK WT 9001 I P65 USER MANUAL Rev 4 1 Technical Support technical witura com 13 COPYRIGHT 2010 WITURA CORPORATION SDN BHD 1g amp Remote Control System Note A disabled input will not trigger an alarm or report 5 4 2 Setup the Working Mode of 4 Analogue Inputs Input 1 2 3 and 4 of WT 9001 can be configured to an analogue inputs signal When the inputs is configured as an analogue input it can measure a 4 20mA input signal or O 5VDC signal and will generate report when the monitored signal reaches the programmable set points To setup the working mode of input you can send the following command by SMS message to the unit Text Command SWT N X N stands for input number 1 4 X stands for Working Mode 1 2 3 and 4 Description Working Mode
20. e following SMS message to the unit REAT 33311111111111111111 Example of Returned Message REAT 33311111111111111111 To check the Anti Theft Alert setting you can send REAT 5 6 GPRS SETTI NGS For Monitoring Software To setup a communication between the WT_9001 software and the WT 9001 unit you need a GPRS enabled SIM card installed into the WT 9001 device and configure it as the below 5 6 1 Programming the User ID p The system requires the user ID programmed in both software and the WT 9001 unit in order to communicate with each other To setup a user ID for the WT 9001 unit you need to send the below command by SMS to the unit WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 26 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD g amp Remote Control System Text Command USI DZ XXXX XXXX stands for 4 digits numeric numbers Example To program User ID 1111 into the WT 9001 device you would send the following SMS command to the unit USIDZ 1111 Note To setup a User ID for the monitoring software please refer to the WT 9001 Server Software Guide To check the programmed User ID you can send USI D 5 6 2 APN Settings For GPRS internet connection you will have to configure the APN Settings needed by your network operator Different mobile operators have different APN settings To configure the APN you would send the following SMS comman
21. hen Witura Telecommunications Co Ltd WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 35 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD
22. mmands by SMS message to the unit Text Command CTC N F N stands for number 5 12 of Input For pulse counter mode N is input number 5 8 F stands for input function 1 12 Function Descriptions Function 1 Function as pulse counter Function 2 E Function as pulse counter e Activate the output relay number according to the input number applied to stay on Eg If pulse counter 2 at Digital Input 6 reached the alert value relay 2 will activate Generates an alert message once alarm counter reaches the alert value Audible alarm will sound once alarm counter reached the alert value if the alarm function is turned on ALM N 1 Function 3 e Function as pulse counter Activate the output relay number according to the input number applied to stay on Eg If pulse counter 3 at Digital Input 7 reached the alert value relay 3 will activate Sends a programmable input alert message STR N once input triggered Generates an alert message once alarm counter reached the alert value in 1 SMS message concatenated Audible alarm will sound once alarm counter reached the alert value if the alarm function is turned on ALM N 1 Function 4 E Function as pulse counter WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 20 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD e Activate the output relay number according to the input number applied for 2 second
23. nd RLNU XXXXXXXX XXXXXXXX stands for 8 digits value ON 1 or OFF Q for the 8 Outputs Example To switch on the output relay number 5 6 7 8 you can send the following text message to the unit RLNU 00001111 Sending the following SMS Message to unit would mean all the relays will be switched off RLNU 00000000 The 1 indicates the ON command and the O zero indicates the OFF command 5 3 3 Setting the Recipient of Relay Off Alert The unit can generate text alerts to all 8 of the administrator s Mobile phone numbers when the relay has turned on or off To set the administrator to receive this alert you would send the following commands by SMS message to the unit Text Command RETR XXXXXXXXXXXXXXXXXXXX X stands for position for 1 20 administrators with function value O OFF 1 9 number of SMS alerts WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 12 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD 1g amp Remote Control System Example To program the unit to generate 2 SMS to administrators 1 2 3 4 5 and 1 SMS to the rest you would send the following SMS message to the unit RETR 22222111111111111111 Example of Returned Message RETR 22222111111111111111 To check the setting you can send the following SMS command to the unit RETR 5 4 INPUT SETTI NGS One of the most important functions of WT 9001 is to receive alarms In order to us
24. nistrator and answers to it Attention Please program the WT 9001 unit systematically begin with programming the administrator number 5 1 Programming the Administrator Number The 20 administrator numbers can be programmed with a text command via SMS Text Command TEL N XXXXXXXXXX N stands for administrator number 1 20 XXXXXXXXXX stands for the phone number you want to program as administrator Please note that it is possible to program up to a maximum of 16 digits for a phone number Example To program phone number 1111222233 as administrator into list number 1 you would send the following SMS command to the unit TEL1 1111222233 Example of Returned Message TEL1 1111222233 WT 9001 I P65 USER MANUAL Rev 4 1 Technical Support technical witura com 10 COPYRIGHT 2010 WITURA CORPORATION SDN BHD ing amp Remote Control System Note Programming the administrator numbers is necessary in order to operate all other functions and to receive text alerts when the relays activated 5 2 Access Control For Administrator Note It is advised that the owner should set the system to allow programming access for administrators only after programming the Administrator numbers Sending SMS Command ANY 1 Only the administrators in the list will have the access control to the system any person outside the list in this case will not have the authority to access the system and text command sent to
25. nitoring devices from reporting of various malfunction or abnormalities There are various kinds of signal that the equipment can send out most common of which are opening or closure of one or more switch relay contact UPS usually provide signals such as incoming power fail battery mode battery level low and switchover failure An air conditioner system may provide signals such as system on off compressor over temperature low gas pressure etc Equipments to be monitored are connected to WT 9001 using these alarm signaling contacts WT 9001 keeps a constant watch over all the contacts Whenever any contact input changes status either from a close to open or from an open state to close state it is captured by WT 9001 It will then process the input according to the configuration provided by the user The correct SMS messages will be sent to 20 mobile phone users WT 9001 is so fast in capturing the change of status of any signaling contacts that no event will be missed out up to 8 inputs can be monitored directly The flexibility of WT 9001 is in allowing remote query of input status using SMS To change contacting mobile phone number is also very easy Authorize personal remotely using SMS command to add change or delete mobile phone number in WT 9001 3 3 4 Analogue I nputs The WT 9001 has 4 analogue inputs that can be configured to measure a 4 20mA signal or 0 5VDC signal It will generate reports when the monitored signal
26. nput amp GSM Mode Only The alarm set point message can be edited and programmed up to 50 characters long You can change the displayed text by sending the following commands by SMS message to the unit Note Only support normal abc ABC English text no special characters Text Command SDF N XXXXX N stands for Input number 1 4 XXXXX stands for the display text that you want to program Maximum 50 characters To check the programmed texts you can send SDF Z N Example If you want the alert message to display Fuel Alert for input 1 when the monitored signal reaches the set point you would send the following SMS message to the unit SDF1 Fuel Alert Note When signal reaches the set point the system will send the programmable alert messages and also report the set point level For example Fuel Alert 10 5 4 5 Reset the Alarm Set Points This function allows you to reset an input s alarm set points to factory default settings To reset alarm set points you can send the following command by SMS message to the unit Text Command WT 9001 I P65 USER MANUAL Rev 4 1 Technical Support technical witura com 16 COPYRIGHT 2010 WITURA CORPORATION SDN BHD tor ng amp Remote Control System CLP N N stands for Input number 1 4 Example To reset input 1 alarm set points to factory default you would send the following SMS message to the unit CLP1 Note Factory Default for Alarm Se
27. ogue GND Blue FUEL as 3 3VDC Output Red Analogue Input 2 Black 0 5 4 5VDC FUEL SENSOR Analogue GND Blue 2 3 3VDC Output Red rale Connection Diagram oY 4 AmA Pressu Auxiliary 12 VOC Output Auxiliary 12VDC Output Auxiliary DC Output Depends on Power Supply Auxiliary 5VDC Output Auxiliary 3 3VDC Output ee 10 1112131415 lo 17 15 19 20 21 22 235 24 252027 21 2 3I SSNSVSVOENSVSENDONA Analogue Input 1 Black 4 20mA l AE i PRESSURE Analogue GND Blue Ne TRANSDUCER 1 9 24VDC Output Red e Analogue Input 2 Black 4 20mA PRESSURE Analogue GND Blue TRANSDUCER 2 9 24 VDC Output Red WT 9001 I P65 USER MANUAL Rev 4 1 Technical Support technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD ing amp Remote Control System PACKAGE CONTENTS 1 pc IP65 Enclosure 1 pc WT 9001 Main Board with GSM Module mounted 1 pc Power Adapter 1 pc Battery Backup 1 pc GSM Antenna 1 pc LCD Display for Assisting in Programming O Ui 43 UJ NJ H CONTENTS laudgoreidrau e mA E UU TES msg e s SELENE AE HU E 9 Installation Instructions see mmm mmm Rmrmrmem mmm nr n n a n d a aM Em WT 9001 IP65 Programming Instructions ececeeesese emm nm mmm LO 5 1 Programming the Administrator Numbers
28. owledgement There are 8 digital output that can be independently controlled 3 7 Remote Editing Of Mobile Phone Numbers WT 9001 has a feature to allow user to remotely add change or delete any mobile phone numbers in WT 9001 memory Re assigning of operation personnel a change of mobiles phone number is also common Rather than having to physically go to the installation site with a notebook computer the authorized personnel can perform the change from anywhere using mobile phone Where there are many installed sites this feature saves time and afford 3 8 System Check Authorized mobile phone group can perform system check by sending a command to WT 9001 If WT 9001 is switched on or working normally it will reply to the querying number WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD ng amp Remote Control System 3 9 GSM Modem Integral to the design of WT 9001 is a GSM 850 900 1800 1900mhz Industrial grade modem Its capabilities and performance are highly optimized by the operating firmware Any change in the GSM signal and receiving conditions are detected quickly and the software automatically takes care of signal errors 3 10 Reliable Performance Besides running the necessary program to perform all the required functions WT 9001 has diagnostic routines running alongside Being a monitoring device WT 9001 must have a
29. reaches 1 billion values will reset automatically to zero Note This Function Works On Digital I nput 5 8 only WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 30 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD ng amp Remote Control System 5 7 7 Reset the Total ncrement Counter Value To reset the total counter value you can send the following SMS message to the unit Text Command CLA N N stands for Input number 5 8 Example When CLA5 is applied means the total increment counter value will be reset for input 5 5 7 8 Sound the Audible Alarm Manually It is possible to sound the alarm manually by sending the following SMS command to the unit which remain active for the period of time set Text Command ALNF X X stands for ON 1 or OFF 0 value When ALNF 1 is applied means audible alarm will sound When ALNFZO Default is applied means audible alarm will turn off To check siren status you can send ALNF 5 7 9 Checking Signal Strength To check the signal strength 0 31 you would send the following SMS command to the unit Text Command CSQ 5 7 10 Checking the System is Operating Correctly It is possible to check the system is operating correctly by sending the following SMS command to the unit WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 31 COPYRI GHT 2010 WITURA CORPORATI ON SDN B
30. rsion of WT 9001 you would send the following SMS command to the unit Text Command EDI Example of Returned Message Software release time lt WT 9001 gt 2009 6 02 01 40HW 1 8SW1 0MW3 4 5 6 16 Enable and Disable of the System To send SMS to enable all the functions WT 9001 prepared by work and SMS to disable all the functions WT 9001 is not prepared by work Command Enable System ENABLE Returned Message ENABLE OK Command Disable System DISABLE Returned Message DISABLE OK WT 9001 I P65 USER MANUAL Rev 4 1 Technical Support technical witura com 33 COPYRIGHT 2010 WITURA CORPORATION SDN BHD itoring amp Remote Control System gt Monit 5 7 17 Auto Restart System The WT 9001 can continuously monitor the system status of its own When there is a problem with system operation or the module is not working properly it will restart the system automatically to avoid the unit stopped working permanently If the system failed to respond within 15 30 seconds it will restart the system 6 TECHNICAL SPECIFICATIONS Item Description Model WT 9001 Operating Voltage 12 28VDC 5W Current Consumption 50mA idle 60mA per active relay No of Inputs 8 Digital amp 4 Analogue Inputs No of Outputs 8 Relay Outputs 0 3A 125 ACV 0 3A 48 DCV Relay Connections Normally Open Normally Closed amp Common Contacts Communication Port USB Port GSM Modem Quad Band 850 900 1
31. rst checking if the SIM requested any PIN code If this is the case the PIN code can be disabled using the security settings on the phone The WT 9001 identifies only 3V SIM Card 1 3 gop Tea Proceed as follows Slide back the SIM door and lift it up Slide the SIM card into the SIM door making sure that the clipped corner of the SIM card lines up with the clipped corner of the SIM holder 3 Close the SIM door WT 9001 I P65 USER MANUAL Rev 4 1 Technical Support technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD ng amp Remote Control System 4 Slide the SIM door to lock the SIM card in place You should install the WT 9001 in a place where there is GSM signal coming from the operator you want to use Check it with a phone before proceeding with the installation If you need to install the device in a place with little signal you may consider using an external antenna that we may supply as an option to be purchased separately with 5m cable WT 9001 IP65 PROGRAMMING INSTRUCTIONS via SMS Only You can program the WT 9001 via SMS commands using your phone Any programming command sent by SMS can be in SMALL or CAPITAL letters The fields between square brackets are parameters do NOT enter the square brackets When you send a command you will receive the answer for the first time even if your GSM number is not in the administrator list This happens because the WT 9001 recognizes any GSM number as admi
32. sage to the unit DLY5 500 WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 22 COPYRIGHT 2010 WITURA CORPORATION SDN BHD tor ng amp Remote Control System 5 4 13 Setting the Function of Opening amp Closing time for Output Relay The system has the function to activate the relay for a specific time and then be deactivated for a specific time in a repeating process To set the opening amp closing time of the relays you can send the following SMS command to the unit Note This function only applied in input function 5 and 6 Text Command for Opening time PWTIN ZX N stands for Output number 1 8 X stands for the number of seconds for relay to stay on Range from 0 9999999 To query relay on time you can send SMS command PWT Z N Text Command for Closing time PWK N ZX N stands for Output number 1 8 X stands for the number of seconds for relay to stay off Range from 0 9999999 To query relay off time you can send SMS command PWK Z N Example Opening time of output 1 is set as 1 minute PWT1 60 and the Closing time as 5 seconds PWK1 5 and function 5 is applied on Input 1 When input 1 is triggered output relay 1 will be activated for 1 minute and close for 5 seconds and then back on for 1 minute and close again for 5 seconds 5 5 ALARM SETTINGS 5 5 1 Turning the Audible Siren Functions On Off When I nputs Triggered The system has the function to
33. t Point are 255 for all set points for all analogue inputs 5 4 6 Checking the Analogue Inputs Status Note This Function Works On Analogue Input Only This function allows you to inquire the live status by an SMS To check the level you can send the following command by SMS message to the unit Text Command FST Example of Returned Message ANIN1 15 ANIN2 99 ANIN3 10 ANIN4 05 5 4 7 Setting the Alert Message Recipients Every input can generate text alerts to all 20 of the administrator s Mobile phone numbers and this function can be changed at any time by sending the following commands by SMS message to the unit Text Command RER N ZXXXXXXXXXXXXXXXXXXXX N stands for input number 1 12 1 4 for Analogue and 5 12 for Digital X stands for position for 1 20 administrators with function value O OFF 1 9 number of text alerts Example 1 WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 17 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD y amp Remote Control System Any alarm coming from Input 1 will generate 2 SMS to administrators 1 2 3 and 1 SMS to the rest you would send the following SMS message to the unit RER1 22211111111111111111 Example of Returned Message RER1 22211111111111111111 OK Example 2 Any alarm coming from Input 2 will generate 3 SMS to administrator 1 2 SMS to administrator 2 3 4 and 5 no SMS to the rest you would
34. t message STO N once input returned to normal Audible alarm will sound when input return to normal if the alarm function is turned on ALM N 1 WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com 21 COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD y amp Remote Control System Function 9 e Function as pulse counter Switch off output relay 1 Function 10 Function as pulse counter Switch off output relay 2 Function 11 Function as pulse counter e Switch off output relay 3 Function 12 E Function as pulse counter e Switch off output relay 4 Note It is required to reset the Counter Alert Value CLA each time you change the input function 5 4 12 Setting the Trigger Time of Alarm Input Note This Function Works On All Digital I nputs The unit will report the state of all inputs when any input changes state for longer than a programmable trigger time The trigger time of each alarm input is programmable and can be varied from a minimum of 500ms to a maximum of 999999ms Any change that does not remain stable for the specified trigger time will be ignored The factory default trigger time is 1 seconds Text Command DLY N ZX N stands for number 5 12 of Input X stands for time in milliseconds Range from 500ms 999999ms Example Assume that you want digital input 5 to report when it changes state for more than 500ms you would send the following SMS mes
35. very high operating reliability and stability Every section of WT 9001 is monitoring each other Should the modem fail to perform its required role the controller will interrogate and restart the modem 3 11 Application p For monitoring and remote control of equipments and machines that are able to provide dry contract signals 8 digital outputs with pulse functions extend control functions Suitable for door access control On Off equipment remotely resetting of Routers Network switches etc Some application examples are Machines Standby Power Generator Electrical Panels Pumps Uninterruptable Power Supplies DC rectifier systems Vending Machines Fire Alarm Panels Gas Monitoring Systems ATM Machines Security Systems Fishery Cold rooms HVAC systems Door Security Network equipment and more WT 9001 IP65 USER MANUAL Rev 4 1 Technical Support technical witura com COPYRI GHT 2010 WITURA CORPORATI ON SDN BHD i ring amp Remote Control System INSTALLATION INSTRUCTION Note It is essential that you read the step by step instructions fully prior to installing and programming the unit 4 1 Screw off the Front Case of WT 9001 I P65 Main Unit 4 2 Installing the Components Antenna LCD Power Supply amp SIM Card Installing the SIM Card Note Installing the SIM Card Please be sure the initial 4 digit PIN code of SIM card is disabled This can be done by placing it in an unlocked Mobile phone and fi