Home
        GUIDE EasIR-0 user manual
         Contents
1.  sub menu     press T to exit main menu operation and return real time IR mode     Function operation    Thermal camera focusing  To motorizedly focus        Aim the lens at the target   F     Press 4 to activate the menu       Press the softkey labeled    Far    and    Near    until the image on the LCD is as clear as possible    Image capturing and saving      Aim the lens at the target of interest and adjust the focus motorizedly or automatically above to get a clear image on  the LCD  and then pull the trigger to capture an image  The image will be frozen and bring up the image capture  menu       Press the softkey labeled  Save   If the SD card is in the camera  the image data will be acquiescently saved in the    SD card     Selecting the Palette          Press J to display main menu      Press the softkey labeled Parameter       Press the softkey labeled Palette            MZ      PJ       Press  amp    to confirm        to shift among different palettes    Setting Tmin and Tmax  P         Keep    depressed for 3sec to display the menu     passes    me         10    User Manual                 Al 4       u eu    k2   P J      Press     to increase the Tmax value  press Y B to decrease the value  press     to switch to Tmin   adjustment mode       The same operation for Tmin adjustment    F      Press 3 to enter Auto mode and Tmin and Tmax will adjust automatically according to the change of    scenery     Reviewing and Deleting Stored Images    To view stored images on
2.  the SD card        y activate the menu      Press the softkey labeled    File    to reveal the review menu    Filelist          Press the softkey labeled  OK  to enter the file list       Press the softkey labeled            and     gt     to toggle between different images  and press the softkey labeled  Select  to    choose the selected image     To delete a single image from the SD card     Perform the steps under viewing stored images above to bring the desired image to the display      Press the softkey labeled    Delete          Press the softkey labeled  Yes      To delete all the images from the SD card       Press to activate the menu        Press the softkey labeled    File         Select    Del All    by pressing softkey labeled          and      and  OK  to confirm        Press the softkey labeled    Yes        Listening to Voice Annotation   To play the voice annotation already stored with an image on the UFlash or SD card       Perform the steps in the  Reviewing and Deleting Stored Images  section to bring the desired image to the  EASIR 0 s display       Press the softkey labeled    Voice          Press the softkey labeled    Play       The saved voice annotation will be replayed through the imager s speaker     11    G aide    User Manual    Changing the Temperature Units    The EASIR 0 will display temperature in Fahrenheit or Celsius  To change the temperature units     M   o     Press to display main menu       Press the softkey labeled Setup       Press 
3. GUIDE  EasIR 0 Thermal Camera    User Manual    Wuhan Guide Infrared Co   Ltd   No  26 Shucheng Rd  Hongshan District  Wuhan 430070 P  R  China    Telephone  4 86 27 8767 1991   Facsimile    86 27 8767 1927   Email  overseas guide infrared com  Internet  www guide infared com        Wuhan Guide Infrared Co   Ltd   2012  Publication No  GUIDE   EASIR 0UM 012    The Quality Management System of Wuhan Guide Infrared Co   Ltd  is approved to ISO9001 2000 for the design and  manufacturing  stockholding  in house repair and site servicing of non contact temperature measuring    instrumentation     Wuhan Guide Infrared Co   Ltd  reserves the right to make changes and improvements on any of the products    described in this manual without prior notice     GUIDE   EASIR 0 Thermal Camera complies with current European directives relating to  electromagnetic compatibility and safety   EMC directive 89 336 EEC  Low voltage directive  73 23 EEC      Copyright     Wuhan Guide Infrared Co   Ltd  2012  All rights reserved worldwide  No parts of the products may be reproduced   transmitted  transcribed or translated into any language or computer language in any form or by any means  electronic     magnetic  optical  manual or otherwise  without the prior written permission of Wuhan Guide Infrared Co   Ltd     This manual must not  in whole or part  be copied  photocopied  reproduced  translated or transmitted to any electronic    medium or machine readable form without prior consent  in writi
4. bolometer  160x 120 pixels  25um   Spectral Range  8 14um   Thermal Sensitivity   lt 100mk at 30  C       Field of View  Focus     20 6   X 15 5  11mm       Focus     motorized       Image Presentation       External Display     3 6  TFT LCD with high resolution                Video Output  PAL  NTSC   Man Machine Communication  Buttons  Respond as per operators    operation  Menu  Microsoft   Windows style       Measurement       Temperature Range     0  C to 250  C       Accuracy      2  C or  2  of reading       Emissivity Correction     Variable from 0 01 to 1 00  in 0 01 increment        Measurement Features     Automatic correction based on distance  relative humidity  atmospheric    transmission and external optics       Optics Transmission Correction     Auto  based on signals from sensors       Image Storage                Type  Removable 2GB SD card  File Format  JPG with analysis records  Power System  Battery Type  AA rechargeable battery  field replaceable  AA Alkaline battery also usable          Charging System        in battery charger          Guide    Battery Operating Time     User Manual    Over 2 hours continuous operation       External Power Operation     AC adapter 110  220 VAC  50  60Hz       Environmental Specification       Operating Temperature     0  C to 50  C       Storage Temperature      10  C to 60  C       Humidity     Operating and storing 10  to 95   non  condensing       Encapsulation     IP43                               Shock  Operatio
5. dhered to at all times   Non optical surfaces  The non optical surfaces of the camera can be cleaned when required  with a soft cloth dampened with water and a  mild detergent   Optical surfaces   The optical surfaces of the camera lens should only be cleaned when visibly dirty  Care should be taken to avoid  touching the exposed lens surface  as skin acid left behind from fingerprints can be damaging to coatings and lens    substrates  Use only a proprietary lens cleaning tissue     Guide    User Manual    Calibration and Repair Philosophy  To ensure the accuracy and reliability of the GUIDE   EASIR 0 Thermal Camera  it is highly recommended that the  instrument be calibrated at 12 monthly intervals   Calibration or repair for the instrument can be obtained by either contacting the address  telephone number on the    cover of this User Manual  or by email to the following addresses  overseas guide infrared com       Caution  The GUIDE   EASIR 0 Thermal Camera does not incorporate any user serviceable parts  Never attempt to    disassemble or modify the camera  Opening the unit invalidates the warranty     Technical Support    Technical support for your Wuhan Guide Thermal Imaging System can be obtained by either contacting the address    telephone number on the cover of this User Manual or by email to the following address     overseas quide infrared com    Feedback to Us    We have tested and verified the information in this manual to the best of our abilities  Yet as we ar
6. e committed to    continuous development and progress  you might find features of the product have been changed since the time of  printing  You are appreciated to let us know about any error you find  and your suggestions for further editions by  either contacting the address telephone number on the cover of this User Manual or by email to the following address     overseas quide infrared com    System Overview    GUIDE   EASIR 0 is a new infrared camera of Guide infrared  breaks the IR world with its lowest price and high  performance  Designed for tough work environments and entry level users  EASIR 0 is far more robust and  shock resistant for any tough working environment and it is easy to operate and allows for the learners to operate  without being trained and take the inspection work easily with one hand  Featured with latest IR Fusion technology  it  helps you pinpoint the problem exactly with the most efficiency  Power on the EASIR 0  let the 3 6  LCD bring you into  the fresh IR world    System Configuration  Please ensure that the following items have been correctly supplied   e IR Camera with visual camera    11mm IR lens  e 3 6  TFT LCD with high resolution  e 2GB SD card  amp  card reader  e AC Adapter  amp  cable      USB extension cable    Guide    e USB driver    e Guide IrAnalyser   Software      User manual    Options  e Sun Shield    User Manual    Technical Specification       Imaging Performance                THERMAL   Detector type  Uncooled FPA micro
7. e lowest limitation  the red indicator will flicker for a moment    then power off automatically     M     Y  Note        When using the battery   only when powering on and in the low battery condition  the indicator will light on     How to charge with batteries    Charge the batteries with battery charger only       v  Note        Please choose qualified rechargeable batteries and battery charger     Buttons Introduction    CER  jel    There are three functional buttons of GUIDE   EASIR 0 From left to right  they are r    and   O and  a trigger button  T      Power on  off the camera    M  The input voltage is 9V keep button depressed for more than 3 seconds to power on  When powering off  keep       M  Zo  J depressed until the switch off bar runs fully  To release the button    at any time before the       the button Y    switch off bar runs fully to leave the power off state           Focus   F  In the non menu state  press 4 to enter focus menu  the following info will be displayed on the screen  n ES  According to the attention  press 4 to focus far  press  amp    focus near  Press Tor       Quick function    G aide       User Manual    pj  In the non function state  long pressing the       to switch between the manual mode and automatic mode  and    pj  press  amp    shortly to enter spot analysis mode  L R   U D    P  jJ    Press     to switch between the up down or left right  ET M  Fo       Press   or    to adjust the value of X or Y s coordinate      Press T to ex
8. he Guide IrAnalyser software     Install USB driver to PC    When there is no menu in the live thermal image  properly connect the USB interfaces of the camera to a USB2 0 port    of your PC with the USB extension cable     Microsoft amp  Windows launches a Found New Device Wizard to guide you to install the driver as follows                   e    Found New Hardware Wizard          Welcome to the Found New  Hardware Wizard    This wizard helps you install software for     USB Device         lf your hardware came with an installation CD     E92 or floppy disk  insert it now     What do you want the wizard to do     O Install the software automatically  Recommended      Install from a list or specific location  Advanced     Click Next to continue        Choose  Install from a list or specific location  advanced   and include the folder where you save the driver    program  Then Click button next to go further     13    User Manual    Please choose your search and installation options        Search for the best driver in these locations     Use the check boxes below to limit or expand the default search  which includes local  paths and removable media  The best driver found will be installed         C Search removable media floppy  CD ROM       v  Include this location in the search     C EasIR 4  EasIR 4_USBdrive x     O Dont search    will choose the driver to install     Choose this option to select the device driver from a list  Windows does not guarantee that  the driver y
9. infrared image can be saved into 2GB SD card or the built in flash  memory in standard JPG format     e SD card can accommodate 2000 images and the built in flash memory can store 200 images     Image Playback   e Images saved into SD card or the built in flash memory can be replayed on the camera    e Temperature measurement can be done on replayed images    e Images saved in SD card and the built in flash memory can be downloaded to PC for further analysis and report    generation with software Guide IrAnalyser     Parts Described                   User Manual            LCD Display       Charging Indicator       Function Softkeys       Microphone       Battery Cover       Speaker  EASIR 4 only        Visual Camera  EASIR 2 4 only        Laser EASIR 2 4 only                N    oO  a  J wy  N    IR Lens          o    Trigger Button       11    USB Interface       Video Interface EASIR 2 4 only        AC Adapter Charging Input Terminal             SD Card Slot          Gai de User Manual    EASIR 0 Charging Instruction    How to use the batteries    M  Zo     Insert the batteries  the indicator will not flicker at once  Press button       to make the red indicator flicker    after 2 seconds   the indicator will alternatively flickers as green and red and stop when entering the self check  interface    If the camera is powered on when battery is low  the red indicator will flicker quickly and power off  automatically       When using the camera  if the batteries consume to th
10. it the spot analysis and return the real time IR mode   Manual calibration   F  On the non menu mode  keep pressing  T  button and then press     button to run shutter calibration    Image frozen and save    On the non menu mode  press T to freeze the image  the following info will be displayed on the screen      se  x  _     Gucde User Manual       Press T again to exit frozen mode and return to the real time IR mode  or   F       Press         to save the image and return to live thermal image    Main menu operation    M     On the non menu mode  press to bring up Main menu  the following info will be displayed on the screen          Press T in the main menu to return real time IR mode       On the main menu mode  press   i 3 3 to enter sub menu of parameter setting                               On the sub menu mode  press     to confirm selecting the highlighted option and enter the next sub menu     press T to exit main menu operation and return to real time IR mode     k2       On the main menu mode  press     to enter file operation sub menu                          i    P     On this sub menu mode  press  amp    to enter next sub menu  press T to exit main menu operation and return  real time IR mode     PI     On the main menu mode  press 4   to enter system setting sub menu     Guide    User Manual           Default  Language  Tunit  TimeDate    AlarmTemp    j        P      On the sub menu mode  press     to confirm selecting the highlighted option and enter the next
11. nal  25G  IEC 68 2 29  Vibration  Operational  2G  IEC 68 2 6  Interfaces  USB 2 0  Real time image and measurement transfer to PC   Physical Characteristics  Weight  0 73KG including battery   Size  111mmx124mmx240mm  Colors Yellow amp blue interlaced or red amp dark interlaced alternative          System Features    Unique Features    e Rugged housing and rubber protection offers high effective operation even in harsh environment    e Big 3 6  LCD plus three button button system make for a friendly navigation with the push of a thumb    e Unique ergonomically handle presents the comfortable feeling    e Auto gate which works as both shutter and intelligent lens cap prevents all disturbing heat radiation caused by    optics and electronics inside  delivers crisp and uniform images and protects the precise lens     e Ultra large capacity SD memory card and built in flash memory offer easy in field storage     e High speed USB2 0 interface enables real time data transfer and camera control     e Robust on board analysis enhances operators    efficiency  amp  productivity     e Low cost enables the ownership of everyone     Imaging Performance    e Motorized focusing of IR lens     Temperature Measurement    e Auto calibration ensures high accuracy     e Auto hot spot tracing and center cursor temperature measurement pinpoint the problem     Image Storage       Guai de User Manual   e Live images can be frozen to be static images   e Frozen images  comprising radiometric data  
12. ng  from Wuhan Guide Infrared Co   Ltd     Table of the Contents    Table ofthe Contents  iniciada ra   E ea arde 1  IO TUCU tai 1  Precautlorns   uu iacit etn Dd 1  E aa aaa aaa anaa a a aa aaa aranan ann aaaea 1  Calibration and Repair Philosophy   o decedat is 2  Technical SUPPOM ease Gee dilli dr D                                            R   a karek   k   2  Feedbackto       ERE EE EP EE EIER E ERI RR ERES 2  System OVE VIEW P L                            daka 2  System Configuration                E E Eke kk kk kk ek kek OR E ROM UR KAKA KAR Ak KA KAR kk    rk    A 2  Technical Special tallar KAR KAR KAK KAK    A AA 3  SICHERER 4  Parts DescriDed s    eoe a ete ki ani xek   yasi zal   waran Ere ter Ee aaa 5  EASIR 0 Charging Instruction id ceo eoruni Dus Du equi e tuu buc tu wane Ed aep Du cuu RD Saat  7  Buttons Introduction  ieu aid K  RA KAWA K  RA KARA K  RA AR   W   KA WALA H  KA 7    A SIRR YO DD e e N e E 10    Guide    User Manual    Introduction    This publication provides the necessary information required to safely operate the GUIDE   EASIR 0 Thermal Camera   It is important to fully check all equipment with which you have been supplied    The equipment should be used  maintained and serviced by suitably trained personnel  capable of carefully following  the procedures and guidelines given in this User Manual    All User Manuals and leaflets should be read thoroughly before proceeding with operation of the equipment    It is also advisable that all User Ma
13. nuals and Instruction Leaflets supplied are kept readily available  for reference when    the equipment is in general use     Precautions    The following precautions must be adhered to at all times and must be considered in addition to any advised  precautions issued at the relevant worksite or work area   e Keep the GUIDE   EASIR 0 Thermal Camera steady during operation   e Do not use the GUIDE   EASIR 0 Thermal Camera in temperature exceeding its working and storage  temperature ranges     Do not direct the GUIDE   EASIR 0 Thermal Camera at very high intensity radiation sources such as the  sun  carbon dioxide lasers or arc welders etc   e Do not expose the GUIDE   EASIR 0 Thermal Camera to dust and moisture  When operating the unit near  water  ensure that the unit is adequately guarded against splashes   e When the GUIDE   EASIR 0 Thermal Camera is not in use or is to be transported  ensure that the unit and its  accessories are stored in the protective carry case   e  Donotre switch on the camera until 15 seconds later after switching it off     Do not throw  knock or vibrate intensely the camera and its components in order to keep them from damage     Do not attempt to open the camera body  as this action will void the warranty     e Keep the SD memory card for the exclusive use of the camera      WEST Tal lala  elo    To ensure that the GUIDE   EASIR 0 Thermal Camera is kept in good working condition and remains fully operational   the following guidelines should be a
14. ocedures to go to Device Manager is as follows  Clicking My Computer  gt  Clicking the right mouse and  choosing Property  gt  Choosing menu Hardware in the System Property dialog box    Choosing option Device    Manager under the menu Hardware     1 Device Manager QuE    File Action View Help         m   62a     5  IDE ATA ATAPI controllers  Sy IEEE 1394 Bus host controllers  C   Keyboards  15  Mice and other pointing devices  ll  Modems   9 Monitors  Ml  Network adapters  PCMCIA adapters    Processors      Sound  video and game controllers    System devices  Universal Serial Bus controllers    GUIDE EasIR 4   Intel R  8280 1DB DBM USB Universal Host Controller   24C2  Intel R  8280 1D8 DBM USS Universal Host Controller   24C4  Intel R  8280 1DB DBM USB Universal Host Controller   24C7  Intel R  8280 1D8 DBM US82 Enhanced Host Controller   24CD  USS Root Hub   USB Root Hub   USB Root Hub   USB Root Hub           4  4        ot             15    
15. ou choose will be the best match for your hardware                 Installation starts  When getting to the step as shown below  choose    Continue anyway    to proceed further     r      Found New Hardware Wizard  Please wait while the wizard installs the software    E    e GUIDE EasIR 4       The software you are installing for this hardware   GUIDE EasIR 4    with Windows XP  y    Continuing your installation of this software may impair   or destabilize the correct operation of your system   either immediately or in the future  Microsoft strongly  recommends that you stop this installation now and ce  contact the hardware vendor for software that has   passed Windows Logo testing     has not passed Windows Logo testing to verify its compatibility   Tell me why this testing is important      STOP instalaton          Installation continues and finishes quickly  Click button Finish     14    G aide    User Manual    Tr    Found New Hardware Wizard    Completing the Found New  Hardware Wizard    The wizard has finished installing the software for        GUIDE EasIR 4    The hardware you installed will not work until you restart  your computer     Click Finish to close the wizard                Go to Device Manager to check and confirm whether the driver has been successfully installed  lf there is    GUIDE  EASIR 0  listed under Universal Serial Bus Controller  it indicates the driver has been properly installed and you  can transfer data from the camera to PC now       The pr
16. the softkey labeled Tunit    Le     P        Press           for Celsius or    for Fahrenheit     Doing spot analysis    EASIR 0 supports single spot measurement  The location of center spot can be adjusted in live image     DNE C     Press 4   button and then       button to bring location adjustment mode of center spot       M  KANN C     The default adjustment mode is    Left Right    mode  press        and A J can move the center spot to left and    Aa    right under this mode  press  P  button to switch into    Up Down    mode  then press        and          can move the  center spot to up and down under this mode  Press    P    button can switch between the above two modes freely        Press    trigger    button can save and exit the location adjustment mode of center spot     How to get accurate temperature    There are a lot of factors affecting temperature accuracy    Here is a brief introduction to some typical parameters  emissivity  background temperature  distance  humidity and etc     Y Note     To get accurate temperature  you shall hold the camera stably and focus the camera well        Emissivity  All objects radiate infrared energy  The amount of energy radiated is based on two primary factors  the  surface temperature of the object and the emissivity of object s surface   The default emissivity is 0 98  which is applicable to most surfaces   For some special materials or surfaces  please refer to the emissivity table to find a right emissivity value     Yo
17. u can change emissivity between 0 01 and 1 00 in menu Para and Emissivity        Tamb  To display and adjust the real time comparative scene temperature of target  The default setting of this  parameter is automatic adjusted by the internal temperature sensor  If needed  this setting can be adjusted    manually according to real temperature of some special scenes  like sky or snow  of measured target        B button and 3 button to bring the submenu of parameter setting  then choose    Tamb    and select     e  Po        Set    option to set the value manually by press            button and     button  The new measurement will be       based on the saved tamb value until re enter the    Tamb    option and exit  which will activate the default automatic  mode   12                Transferring Data from the Camera to PC    Guide    User Manual    Distance  To set the proper distance from target  the distance range is from 0 1 meter to 50 meters     Relative Humidity  To set relative humidity percentage value between O and 100 according to the practical    environment     Before transferring data from the EasIR 0 camera to PC  ensure that the PC offers USB2 0 interface and the USB    driver for the camera has been successfully installed in the PC     If SD card is inserted in EASIR 0  the PC will identify the EASIR 0 as a removable hard disk  you can copy the    saved data to PC or delete them from the card  or even format the SD card and etc  But you cannot operate on it in    t
    