1. GB PEDESTRIAN AUTOMATIC HERMETICALLY SEALED SLIDING DOOR for HOSPITALS USER MANUAL EVAi c EVOLUS HOSPITAL 16005 A CE TRANSLATION OF WWWUTALV MADE JT UNI EN ISO 9001 200C ORIGINAL INSTRUCTIONS RECOMMENDATIONS THIS INSTRUCTION MANUAL IS INTENDED FOR THE FINAL USER OF A LABEL AUTOMATIC SLIDING DOOR SYSTEM IT IS UNDERSTOOD THAT INSTALLATION AND TESTING MUST HAVE BEEN CARRIED OUT BY SPECIALISED PERSONNEL GENERAL SAFETY WARNINGS BEFORE COMMISSIONING THE AUTOMATIC DOOR PLEASE CAREFULLY READ THIS MANUAL PROVISIONS The automatism has been designed to be used exclusively with pedestrian automatic sliding doors The manufacturer accepts no responsibility for incorrect product usage as well as forany damages arising from changes to the system made without his prior consent When operating the system accident prevention regulations must be observed REMARKS Always meet the usage and maintenance conditions provided for by LABEL Maintenance and repair operations must only be performed by qualified and properly trained personnel PROPER BEHAVIOUR Only use the automatic door if itis in perfect technical conditions In case of failure or malfunction that might affect safety immediately contact the service centre Inappropriate use of the system may cause serious injuries and damage ABEL AUTOMATIC SLIDING DOOR EVAi c EVOLUS HOSPITAL 16005 models EVHT E SX EVHT E DX TABLE OF CONTEN
2. TS 1 INDICATIVE SYSTEM DESCRIPTION page 4 2 TECHNICAL DATA 4 3 AUTOMATIC DOOR OPERATION 5 3 1 NORMAL DOOR OPERATION 5 3 2 DOOR OPERATION IN NIGHT LOCK MODE 5 4 PROGRAM SELECTORS 6 4 1 MECHANICAL KEY SELECTOR EV MSEL 6 4 2 DIGITAL PROGRAM SELECTOR N DSEL 7 4 2 1 GENERAL PROGRAMMING MENU 9 4 2 2 PASSWORD 10 4 2 3 LANGUAGE 12 5 OPERATION IN CASE OF POWER SUPPLY FAILURE 13 6 NOTIFICATION OF ERRORS AND OPERATION PROBLEMS 14 7 MAINTENANCE LO 8 DISPOSAL 15 1 INDICATIVE SYSTEM DESCRIPTION AUTOMATISM POWER SUPPLY 230V OPERATOR SIDE l OPPOSITE SIDE _ gt 1 Closing safety sensor 2 Opening button 3 Digital programmer 4 Closing safety sensor 5 Opening safety sensor 6 Touch sensitive detector 7 EVHT E operator 2 EVHT E OPERATOR TECHNICAL DATA OPERATOR MODEL EVHT E SX leftward opening EVHT E DX rightward opening POWER SUPPLY 230Vac 10 50 60Hz POWER 130W FREQUENCY OF USE continuous PAUSE TIME Max 20 sec WORKING TEMPERATURE 15 C 50 C DEGREE OF PROTECTION IP22 POWER SUPPLY OF EXTERNAL ACCESSORIES 13 Vdc EVHT TRANSOM DIMENSIONS H x D 135 x180 mm 3 AUTOMATIC DOOR OPERATION WARNING Always contact the assistance technician before commissioning the door to learn how the automation works Switch on the power supply by means of the system switch The automation electronic control unit beeps shortly to indicate that the automat
3. ard HOW TO CHANGE THE PRIMARY PASSWORD e Select PRIMARY PASSWORD e Press OK F1 button ACTUAL C PASSWORD D e Type the default preset primary password A A A A A by pressing 5 times on A PASSHORD button If the primary password is not the default password as it had already been changed before type the currently used primary password lA EAlT B LE PASSIORI D el e Type the new primary password selecting a combination of 5 characters from the letters A B C D PA TEST B 10 c assure D A EXIT B REPEAT HEN c PASSWORD LD PASSWORD OK PA EXT B HOW TO CHANGE THE SERVICE PASSWORD e Select SERVICE PASSWORD e Press OK F1 button A EXIT E e PASSIORD D ra Peat E C FESSURE D A EXIT B C T LD pa eat E Itis required to repeat the new password so type the previous combination again If the typed password is correct the PASSWORD OK message appears on the display for one second then the system switches back to the PASSWORD MANAGEMENT section press the EXIT Ka button to return to the general programming menu If the typed password doesn t match the previous one the PASSWORD ERROR message appears on the display the system will switch back to the PASSWORD MANAGEMENT section and the user will have to repeat the procedure Type the primary password Type the new ser
4. e opened by pressing the OPEN button or using the Spyco radio control if any e The safety function sensors and behaviour in case of obstruction are active and work as described in par 3 1 for normal operation 4 PROGRAM SELECTORS The program selector allows the door user to select the operating mode Depending on one s preferences the EV MSEL mechanical key selector or the N DSEL digital programmer can be used Each program selector is described in details below 4 1 EV MSEL MECHANICAL KEY SELECTOR OPERATING MODE Insert and rotate the key in EV MSEL selector to select the program desired EJ Open door program The door stops in complete opening position T Reduced opening during winter For reducing the opening 1 Bi directional automatic program CJ The door automaticallv opens when each opening control activates T Single direction automatic program output only CJ To exclude the incoming detection on external radar input Night lock program The door can only be opened through the OPEN input or using the SPYCO remote control if any The key can be taken out of the selector when in any position in order to prevent the work program from undesired changes 4 2 DIGITAL PROGRAM SELECTOR N DSEL By pulse pressing the button choose the automatic door operating mode Each time a button is pressed it switches from a work program to the next one TWO WAY lele uz GES esco The operating programs to be sel
5. ected by XS button are described below Bi directional automatic program The door automatically opens when each opening control activates Single direction automatic program output only To exclude the incoming detection on external radar input Single direction automatic program input only To exclude the outgoing detection on internal radar input Open door program The door stops in complete opening position Night lock program The door can only be opened through the OPEN input or using the remote control if any Free manual door The automatic operation is disabled and door can be manually open MANUAL Operation of other buttons located on N DSEL program selector panel Em REDUCED OPENING DURING WINTER r Diass F3 K To reduce the passage opening To activate the reduced opening during winter press the ke button once the symbol on the display indicates that the function is on To disable the reduced opening during winter press the x button once more F1 Door opening command Pressing the F1 button will open the door The F1 may open the door even when the NIGHT LOCK work program is selected if the operator electronic control unit is set accordingly F3 Itis only used if the N DSEL digital programmer manages two automatic doors The N DSEL digital programmer can independently manage the operation of two EVHT E sliding automatic doors Pressing the F3 button allows to select the door on whic
6. h the work program is set The number 1 appears on the display when door 1 is selected the number 2 appears if door 2 is selected 4 2 1 GENERAL PROGRAMMING MENU The user can enter the general programming menu when he wishes to select the desired language for the texts that appear on the display or when he wishes to enable a password to prevent any unauthorised access to the N DSEL digital programmer DIAGRAM 1 TUO WAY gt nv gt gt E gt YseTh 5 EXIT XSET YSET EXIT YSET EXIT YSET EXIT E LANGUAGE 4 KARTI a gt F1 i Jag i fENTER WW EXIT SOD TE O EE Sla OH LE x Eat ORD OK kk di CERTER MI EMIT SIS SECTION SECTION UNUSED RESERVED FOR RESERVED FOR TECHNICAL STAFF TECHNICAL STAFF LANGUAGE SECTION CON ON COON WSETA EXIT VSETA EXIT WSETA EXIT NAZ NAZ NAZ SERVICE 4 2 TIELA Fe COMMUHICATIOH SET UP EI PU STA DRE O ENS i PESTEN GA Ss EEE SECTION RESERVED FOR TECHNICAL STAFF E DAILY OPEHIMG SET UP 4 UNUSED SECTION RESERVED FOR TECHNICAL STAFF PASSWORD MANAGEMENT SECTION The paragraphs below explain the procedure to be followed to manage the user password and to select the language 4 2 2 PASSWORD To prevent the door work program from being modified a password can be entered that must be input every time the N DSEL programmer is used To enable the password perform the operations listed below 1 Press the SET button fo
7. he primary password fA exit BI UH PASSWORD OH UFF PASSWORD OFF OHN Exit OFF e Press the OFF button F1 to disable user password usage To return to the general programming menu press the EXIT Ke button twice From thismomenton the access to N DSEL digital programmer like program selector is free 4 2 3 LANGUAGE To select the language perform the operations listed below Ger 1 Press the button for 5 seconds to enter the general programming menu see Diagram 1 in the previous paragraph 2 Press the F1 three times to switch to the Language sub menu 3 Press the Enter ke button to access the Language section e UsetheF2and ake buttons to move arrow to the desired language e Press the EXIT Ke button to return to general programming menu e Press the EXIT button again to return to the main view of the automatic door work program 5 OPERATION IN CASE OF POWER SUPPLY FAILURE If the battery module is installed in the operator automatic door operation is guaranteed by an emergency battery Door automatically opens and remains open if the program selector is set on automatic programs Door stays closed on the work program NIGHT LOCK and it can be opened using an opening command on the OPEN input e POWER SUPPLY LIGHT DISPLAY on N DSEL PROGRAMMER Mains power supply on and connected battery being charged Mains power supply off and door operating with charged battery e Main
8. ic door is powered The first opening command starts a calibration cycle during which the door opening speed is very low until the end of the stroke to find the stop point after the delay time has elapsed the door closes back at normal speed 3 1 NORMAL DOOR OPERATION e When something enters the motions sensor internal and or external radar detection area the door opens and stays open until sensors detect the presence then once the pause delay has elapsed the door closes back e When the manual door opening button is pressed the door opens and stays open until the command remains active then once the pause delay has elapsed it closes back e Ifthe closing safety sensor detects a presence the door immediately reopens and stays open as long as the sensor remains engaged e Ifthe opening safety sensor detects a presence the door slows down and proceeds very slowly until the opening stroke is completed e f during the opening motion the door bumps against an obstacle it stops and closes back When it opens again later it slows down near the point where it had met the obstacle to avoid further impact e fduring the closing motion the door bumps against an obstacle it stops and opens back When it closes again later it slows down near the point where it had met the obstacle to avoid further impact 3 2 DOOR OPERATION IN NIGHT LOCK MODE e The door cannot be opened through the external and internal radars e The door can only b
9. oblem Should any malfunction occur the Customer must contact the Support Centre and use the door manually without powering it 7 MAINTENANCE The maintenance plan must be observed to ensure the life and safe operation of the automatic door We recommend that you sign a maintenance contract providing for periodic intervention on the system by specialised technicians If the user has the N DSEL program selector he will be warned that the maintenance interval has expired when the message PROGRAMMED MAINTENANCE message is shown on the display kal SCHEDULED MAIHTEHAHCE Each maintenance operation is recorded into the maintenance register The final user must limit himself to cleaning surfaces fixture and if necessary the motion and presence sensors taking care to lock the door while performing these operations 8 DISPOSAL At the end of its life this system must be disposed of in accordance with national provisions To this purpose we recommend that you contact specialised operators LABEL service centre EVOLUS Made in Italy by ABEL Via Ilariuzzi 17 A S Pancrazio Pse 43126 PARMA ITALIA Tel 39 05 21 67 52 Fax 39 05 21 67 52 22 infocom labelspa it www labelspa com A SUD ISO 9001 AZIENDA CERTIFICATA SISTEMA QUALITA UNI EN ISO 9001 2000
10. r 5 seconds to access the general programming menu see Diagram 1 at para 4 3 1 2 Press the F1 button five times to switch to the Password Management sub menu 3 Press the Enter 3 amp button to access the Password management section PASSWORD MANAGEMENT Fi PASSWORD MANAGEMENT PRIMARY PASSWORD TEMPORARY PASSWORD TECHMIQUE PASSWORD A PASSWORD OH OFF This section displays the two passwords available to the final user the primary password and the service password The technical password is only reserved for the technical staff members in charge of installation and maintenance operations PRIMARY PASSWORD for the system s owner user It is a 5 character password used by the user to prevent unauthorized persons from having access to N DSEL programmer and change the work program Using a primary password is optional and must be enabled by system s owner Default preset primary password is A A A A A WARNING When enabling the password be careful not to forgetthe access combination SERVICE PASSWORD for user It is a 5 character password that the system s owner may divulge to persons to be authorized to use N DSEL programmer The service password only allows changing the automatic door work program Default preset service password is A A A A A To change the service password it is necessary to have access by primary password Use the xke button to move the selection arrow downward F2 button to move back upw
11. s power supply off and door operating with almost exhausted battery e Mains power supply on with inefficient battery e When the battery is exhausted or if there is no emergency battery the door can be opened using either the lifting handle or the embedded handle 6 NOTIFICATION OF ERRORS AND OPERATION PROBLEMS PROBLEM LIKELY CAUSE SOLUTION The door opens but it doesn t close back The door opens very slowly The door doesn t respond to the opening commands The door stops during the stroke and inverts the running direction The electronic control units beeps multiple times and door operation is irregular The D symbol appears on the display The motion radars or the closing safety sensor detect the presence of an objector of a person The opening safety sensor detects an obstacle The MANUAL FREE DOOR function can be activated The door detects an obstacle along its stroke The fixture experiences friction along its stroke The defect depends on the number and length of the beeps The system has detected a machine operation error Check that the radars or the sensors are not engaged Identify the obstacle and remove it Check the setting of the program selector Identify the obstacle and remove it Properly arrange the fixture for this operation please contact the service centre Contact the service centre to resolve the problem Contact the service centre to resolve the pr
12. vice password selecting a combination of 5 characters from the lettersA B C D It is required to repeat the new password so type the previous combination again If the password typed is correct PASSWORD OK is shown on display for one second and the system returns to the PASSWORD MANAGEMENT section Press the EXIT Ka button to return to general programming menu If the typed password doesn t match the previous one the PASSWORD ERROR message appears on the display the system will switch back to the PASSWORD MANAGEMENT section and the user will have to repeat the procedure ENABLING USER PASSWORD USAGE primary and service Select PASSWORD ON OFF e Press OK F1 button c P iss WOE D D A E IT B UH PASSWORD OH UFF PASSWORD OFF on Exit OFF e Press the ON button to enable the usage of user passwords and return to the PASSWORD MANAGEMENT menu To return to the work program view press the EXIT Ka button twice e From this moment on whenever the user wants to access to N DSEL digital programmer to change the automatic door work program the primary or service password must be typed When the user decides to enable the password usage it is recommended to change the combination of both primary and service password DISABLING USER PASSWORD USAGE e Fromthe PASSWORD MANAGEMENT section select PASSWORD ON OFF e Press OK F1 button ACTUAL e PASSWORD D gg OTTONE e Type t