PR2200ELCDSL / PR3000ELCDSL User`s Manual

image

Contents

1. HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Make sure that the total Volt Amp VA requirements of your computer monitor and peripheral equipment does not exceed 2200VA 3000VA 2 Ensure that the equipment plugged into the battery power supplied surge outlets does not exceed the UPS unit s rated capacity 2200VA 1980W for PR2200ELCDSL 3000VA 2700W for PR3000ELCDSL If the rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip BASIC OPERATION DESCRIPTION 1 Power Switch Used as the master on off switch for equipment connected to the battery power supplied outlets 2 Power On Indicator This LED is illuminated when the utility power is normal and the UPS outlets are providing power free of surges and spikes LCD Module Display Intelligent LCD display shows all the UPS information using icons and messages For more information please review the Definitions for Illuminated LCD Indicators section below 4 Down Display Button The button can be used to select the LCD display contents including Input Voltage Output Voltage and Estimated Run Time Short press the button to scroll down the function menu Pressing the button for 2 seconds will keep the LCD display always on or turn the LCD display off while in AC Utility power mode For more information about the Down Display Button please refer to the Function Se
2. 4 LOAD capacity Sensitivity setup This meter displays the approximate output load level in 20 increments of the UPS battery outlets It can also be sensitivity setup meter if you are in Setup mode It is to control the sensitivity of the UPS to switch to Battery Mode by selecting UPS shutdown voltage range When the sensitivity is increased the UPS will switch to Battery Mode with less input power variation The battery is worn 5 BATTERY capacity This meter displays the approximate charge level in 20 increments of the out replacement batteries at nap i service cpsww com a UPS s internal battery During a blackout or severe brownout the UPS switches to battery power the BATTERY icon appears and the charge level decreases u Mechanical problem e a at 6 FAULT This icon appears if there is a problem with the UPS Press the POWER button to turn off the The on off switch is designed to prevent Turn the UPS off Wait 10 seconds and damage by rapidly then turn the UPS on turning it off and on The UPS will not turn on Contact CyberPower Systems about UPS Connect the USB cable to the UPS unit and F01 Battery Mode or AC Utility Power Mode Overload fault Turn on the UPS again The USB cable is not an open serial port on the back of the F02 Battery Output Short fault Turn on the UPS again PowerPanel Business Edition connected computer You must use the cable that F03 Charger Fault Contact CyberPower Systems for su
3. berPower Reliability Quality Value Cy tay ita team Ta CER TONENE DRT EEN ee sai cso atl ttt ttle gate gt A PR2200ELCDSL PRSOOOELCDSL User s Manual K01 0000393 00 IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate your UPS CAUTION The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection DO NOT plug the UPS into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect the operation and safety of life support equipment medical applications or patient care CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery There are no us
4. Initiative CSCI accordance with the Restriction on Hazardous Substances ROHS Waste Electrical and Electronic Equipment WEEE protocols as well as ISO 14001 and IECQ QC080000 CyberPower pledges to provide the advanced energy solution for the environment and become a leading eco friendly organization in the UPS industry Reduce Energy Cost with GreenPower UPS Technology CyberPower s goal is not only to provide eco friendly products but also to bring the best value for consumers The advanced energy saving design improves the operating efficiency and eliminates waste energy consumption As a result consumers will enjoy significant energy cost savings with the adoption of GreenPower UPS technology ENERGY SAVING TECHNOLOGY BATTERY REPLACEMENT CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel knowledgeable of batteries and their precautions CAUTION When replacing batteries replace with the same type and number of batteries or battery packs CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present the risk of electrical shock Do not dispose of batteries in a fire as they may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to the skin an
5. d OPTION 1 USER SUPPLIED NORMALLY CLOSED SWITCH 4 5 JUMPER 5 N C EPO SWITCH RJ11 PLUG N O EPO SWITCH RJ11 PLUG 10 SNMP HTTP Network Slot Remove the cover panel to install an optional RMCARD to remotely monitor and manage your UPS over a network 11 Circuit Breaker Located on the back of the UPS the circuit breaker provides overload and fault protection 12 AC Input Connect the AC power cord to a properly wired and grounded outlet HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least 8 hours is recommended to ensure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet The unit will charge in both the on and off position Note This UPS is designed with a safety feature to keep the system from being turned on during shipment The first time you turn the UPS on you will need to have it connected to AC power or it will not power up 2 If you will use the software connect the USB cable to the USB port on the UPS 3 With the UPS unit off and unplugged connect the computer monitor and any externally powered data storage device Zip drive Jazz drive Tape drive etc into the battery power supplied outlets DO NOT plug a laser printer copier space heater vacuum paper shredder or other large electrical device into the bat
6. d eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take TECHNICAL SPECIFICATIONS the following precautions before replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 DO NOT lay tools or other metal parts on top of battery or any battery terminals 4 Disconnect the charging source prior to connecting or disconnecting battery terminals 5 Wear rubber gloves and boots Input 6 Determine if the battery is inadvertently grounded If inadvertently grounded remove source Frequency Range of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL AVR Function SHOCK The likelihood of such shock will be reduced if such grounds are removed during Output eee installation and maintenance applicable to a UPS and a remote battery supply not having a On Battery Output Voltage grounded circuit On Battery Output 50 60Hz 1 Frequency CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF Overload Protection On Utility Circuit Breaker amp Internal Current Protection USED BATTERIES ACCORDING TO THE INSTRUCTIONS On Battery Internal Current Limiting Turn off and unplug all connected equipment rotection es 2 Turn the UPS off and unplug it from the AC power source Operating Temperature 32 F to 104 F 0 C to 40 C a Remove the front panel of the UPS 4 Remove two screws fr
7. er serviceable parts inside except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensation from the aquarium can come in contact with metal electrical contacts and cause the machine to short out DO NOT USE THE UPS ON ANY TRANSPORTATION To reduce the risk of fire or electric shock do not use the unit on any transportation such as airplanes or ships The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out INSTALLING YOUR UPS SYSTEM UNPACKING The box should contain the following 1 UPS Unit x 1 2 Emergency Power Off Cable gray x 1 3 Serial Cable x 1 4 USB Cable x 1 5 User Manual x 1 6 Management software Disk x 1 7 Function Setup Guide x 1 8 IEC to IEC Power cord x 4 9 IEC to AU Power cord x1 OVERVIEW The PR2200ELCDSL PR3000ELCDSL provides automatic voltage regulation for inconsistent utility power The PR2200ELCDSL PR3000ELCDSL features 405 Joules of surge protection and provides battery backup during power outages The PR2200ELCDSL PR3000ELCDSL ensures consistent power to your computer system and its included software will automatically save your open files and shut down your computer system during a utility power loss
8. ere brownout or blackout P N T this icon appears and an alarm sounds two short beeps _ LOAD i followed by a pause to indicate the UPS is operating ee Bessas 5 from its internal batteries Durin rolon rown 6 F secu ie spa wil ene ir sr ieee o A amp oP Circuit breaker button is Circuit breaker has al wae an a a sae ag i o Ave Mure SCHEDULELOAD S P rojecting from the back of the tripped due to an P A Ree re and the BATT CAPACITY meter shows one 20 T SETTING TIME TO TURN ON E g proj g ae the circuit breaker by depressing the button capacity segment shaded The capacity depends on how INPUT m m kva uni OVEROAN and then turn the UPS on much load added and the runtime left to indicate the ESTIMATED jh j fh Hz Battery not fully Recharge the battery by leaving the UPS UPS s batteries are nearly out of power You should save YF RUN TIME Cael Vaal Mama Hr F Hae charged plugged in files and turn off your equipment immediately or allow the e U y does not perform Contaci Cyber Pawar Sysienis abou software to shut the system down g expected runtime Battery is slightly worn replacement batieresiat 3 Energy Saving The UPS in energy saving bypass mode When the utility power is normal and the out l l service cpsww com au battery is fully charged the UPS will go into energy saving bypass mode automatically See CyberPower GreenPower UPSTM Technology section for more information
9. om the battery compartment cover and slide the cover completely off of Total of UPS outlets IEC x 9 the unit ene 221 x 170 x 432 mm 5 Remove the batteries from the compartment Dimensions LxWxH 6 Disconnect the battery wires from the batteries Weight kg 23 3 re Install the replace batteries by connecting the red wire and black wire to the same color Battery connectors from the battery pack Battery Sealed Maintenance Free Lead Acid Battery 8 Put the batteries back into the compartment Typical Recharge Time 9 Re install the battery compartment cover and tighten the retaining screws Charging Current Max 10 Put the front panel back on the UPS User Replaceable 11 Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge Indicators Power On LCD Display Online On Battery Fault Replace Battery Audible Alarms On Battery Low Battery Overload REMINDER Batteries are considered HAZARDOUS WASTE and must be disposed of properly Almost any retailer that sells lead acid batteries collects used batteries for recycling PowerPanel Business one NA Sensi 008 Linn Edition Software Self Test Auto Charger Auto Restart USB interface Expansion Port EPO Port Certifications Certifications CE RCM DEFINITIONS FOR ILLUMINATED LCD INDICATORS 1 ONLINE The UPS is supplying utility power to D B D TROUBLESHOOTING connected equipment r geen nae P SENSITIVITY 2 BATTERY During a sev
10. pport i inactive came with the unit F04 Internal Fault Contact CyberPower Systems for support The unit IS not Shutdown your computer and turn the F05 Fan Abnormal Contact CyberPower Systems for support providing UPS off Wait 10 seconds and turn the 7 OVER LOAD This icon appears and an alarm sounds to indicate the battery supplied outlets are battery power UPS back on An should reset the unit overloaded To clear the overload unplug some of your equipment from the battery supplied outlets until the Guerioad Remove excessive load and restart the icon turns off and the alarm stops UPS 8 SCHEDULE Users can setup the schedule to turn on and shut down the computer and UPS through Output Short Contact CyberPower Systems at PowerPanel Personal Edition software The LCD display will show how much time is left before the UPS o service cpsww com au i The fault LED is illuminated will turn back on or shut down Contact CyberPower Systems at Battery Overcharge service cpsww com au 9 ESTIMATED RUNTIME This displays the run time estimate of the UPS with current battery capacity and load Over T Contact CyberPower Systems at 10 OUTPUT meter This meter measure in real time the AC voltage that the UPS system is providing to ver Temperature service cpsww com au the computer such as normal AC line mode AVR mode and battery backup mode Note The OUTPUT Additional troubleshooting information can be found at www cpsww com a
11. tery power supplied outlets The power demands of these devices will overload and possibly damage the unit 4 Plug the UPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e g air conditioner refrigerator copier etc Avoid using extension cords 5 Depress the power switch to turn the unit on The power on indicator light will illuminate and the unit will beep 6 If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on 7 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge 8 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 9 To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to ensure battery life NO CONNECTION CYBERPOWER GREENPOWER UPS TECHNOLOGY CyberPower s Green Commitment CyberPower is dedicated to the development of green products and has adopted Green practices throughout its business including membership in Climate Savers Computing
12. tup Guide 5 Up Mute Button Short press the button to scroll up the function menu Holding the button for more than 2 seconds will silence the alarm For more information about the Up Mute Button please refer to the Function Setup Guide 6 Enter Setup Button Press the button for 2 seconds to enter the setup menu and then select the functions for configuration For more information about the Enter Setup Button please refer to the Function Setup Guide 7 Battery and Surge Protected Outlets The unit has nine battery powered surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space heater vacuum Sump pump or other large electrical devices into the Battery and Surge Protected Outlets The power demands of these devices may overload and damage the unit 8 Serial USB Ports to PC The Serial and USB ports allow connection and communication between the computer and the UPS unit Note Only one port can be used at a time 9 EPO Port Use the provided gray EPO cable to connect to a provided EPO contact switch Follow the appropriate circuit diagram to the right to wire the cable to your EPO configuration The EPO remote switch is a switch installed in an outside area connected to the unit via the Emergency Power Off cable In case of an emergency it can be used to immediately cut off power from the UPS a
13. u meter shows the status of the battery backup outlets in terms of load frequency and voltage 11 INPUT meter This meter measures the AC voltage that the UPS system is receiving from the utility o wall outlet The UPS is designed through the use of automatic voltage regulation to continuously correct For more information visit www cyberpower com or contact output voltage to connected equipment to a safe voltage output range In the event of a complete power loss Cyber Power Systems Inc severe brownout or over voltage the UPS relies on its internal battery to supply consistent output voltage The INPUT voltage meter can be used as a diagnostic tool to identify poor quality input power 12 EVENT This meter records the number of power outages 13 MUTE This icon appears whenever the UPS is in silent mode The alarm does not beep during silent mode until the battery reaches low capacity 14 AVR Automatic Voltage Regulation This icon appears whenever your UPS is automatically LY correcting low AC line voltage without using battery power This is a normal automatic operation of your UPS and no action is required on your part V 5 0 0 0 For more information about functions setup please refer to the Function Setup Guide All rights reserved Reproduction without permission is prohibited