Home
LF1030 HYDRAULIC PATIENT LIFT LF1040
Contents
1. LF1030 hydraulic patient lift components mm LF1040 Item Qty Description 1 Mast Boom Pump assembly LF1030 Mast Boom Actuator assembly LF1040 Note Actuator Charger Pendant and mounting items are packaged separately on LF1040 LF1030 INS LAB RevB10 ASSEMBLY 1 Remove the locking pin from the mast sleeve located on the rear of the base 2 Install the L inserts in the base 3 With the boom pointed in the same direction as the base legs insert the mast into the sleeve 4 Insert the locking pin through the holes of the sleeve and mast and attach the locking cable to the end of the pin 5 Screw the two mast attachment bolts into the holes in the sleeve of the base install mast attachment bolts LF1030 INS LAB RevB 10 6 Screw the push handles into the mast and tight en the nuts 7 Insert spreader bar attachment rod into spreader bar Insert spreader bar rod into the U bracket at the end of the boom Align holes Insert spreader bar attachment bolt and tighten 8 Install the base adjustment handle in the socket located behind the mast sleeve on the base With base handle to the far right position insert and tighten base attachment bolt to ensure that the handle is firmly attached to the base 9 LF1030 only For shipping purposes the boom is in its lowest position To elevate turn the pump knob clockwise until hand tight and operate
2. attendant Please note the following special statements used throughout this manual and their significance Z WARNING Indicates a potential hazard situation or unsafe practice that if not avoided could result in death or serious personal injury 4 CAUTION Indicates a potential hazard situation or unsafe practice that if not avoided could result in minor personal injury or product property damage Note Provides application recommendations or other useful information to ensure that you get the most from your product LF1030 INS LAB RevB 10 3 2 SAFETY PRECAUTIONS IMPORTANT Before using patient lift please read and adhere to the following safety precautions and warnings Failure to do so could result in serious injury or damage to your patient lift Always consult your healthcare professional to determine safe methods most suitable for your individual abilities Protect yourself your attendant and patient lift by having it serviced regularly If you experience any malfunction contact your Lumex dealer immediately as a hazardous condi tion could result causing personal injury or damage to your patient lift Periodic inspection adjustment and replacement of worn parts are necessary to provide years of excellent service Refer to CARE AND MAINTENANCE section of this manual WARNINGS Z WARNING Important Read and understand these instructions before assembling or us ing the LF1030 and LF1040 If you do not understan
3. Lift patient maintaining patient s position facing attendant until patient s feet swing easily off the bed 10 Position patient above wheelchair or commode chair Lock lift brakes N WARNING Before transfer ensure wheelchair or commode chair wheel locks are in locked position Wheelchair wheel locks must be in a LOCKED POSITION before lowering the patient into the wheelchair or unexpected wheelchair movement could result which may result in serious injury to both the patient and the attendants 11 SLOWLY release pressure knob by turning counter clockwise to gradually lower patient During descent assist patient in attaining correct sitting posture 12 When patient is seated push down on boom to slacken sling loops Patient can remain seated on sling 13 For commode chair use adjust clothing before moving lift to straddle commode chair Keep sling loops taut and ensure that patient is in a comfortable position LF1030 INS LAB RevB10 15 7 CARE AND MAINTENANCE Proper care and maintenance are essential to keeping your Lumex patient lift in a safe operating condition In addition to inspecting the unit before each use periodic maintenance checks should be done We further recommend that this unit be serviced at least once annually by an authorized dealer Z WARNING It is extremely important that the patient lift be inspected before each use Ensure that all hardware and accessories are secure and that the actuator is function
4. down Note If the hydraulic cylinder begins leaking fluid do not operate Contact your Lumex dealer for a new cylinder responding and relay is not Actuator goes up or down but not both 9 SPECIFICATIONS Note All dimensions are given in inches unless otherwise specified Lifting height range Note As measured from point Minimum 27 4 where spreader bar attaches to boom Maximum 77 7 Mastheight St 4 00 diameter both locking and non locking odtWegh O Ab 103 2 Ib Specifications are subject to change without notice LF1030 INS LAB RevB 10 20 10 LIMITED WARRANTY GF Health Products Inc warrants this product to be free from manufacturing defects in material and workmanship for its period of warranty that is in accordance with industry standards This warranty is extended only to the original purchaser consumer or dealer non consumer of this new product and to no other purchaser or transferee GF Health Products Inc warrants the Lumex LF1030 Hydraulic Patient Lift and its components to be free from defects in workmanship and materials as listed below Frame Parts 1 Year Hydraulic Pump Year GF Health Products Inc warrants the Lumex LF1040 Electric Patient Lift and its components to be free from defects in workmanship and materials as listed below Frame Parts 1 Year Electronics 1 Year Actuator 1 Year The Warranty period for the consumer com
5. ing properly Failure to do so could result in patient attendant injury or damage to your patient lift Torn cut frayed or broken slings can fail resulting in serious injury Only use slings in good condition Inspect before each use Destroy and discard old worn and unusable slings When you believe a component or part is not functioning properly immediately contact your au thorized Lumex dealer as a potentially hazardous condition could exist BEFORE EACH USE Before each use of the patient lift ensure that e All nuts and bolts are tight e The lift moves freely with caster brakes off e Rear caster brakes operate properly e Base adjustment mechanism operates easily e Spreader bar clips are secured tightly e The hydraulic pump operates properly LF1030 only The electronic components operate properly LF1040 only BATTERY To increase the longevity of the battery keep the battery on charge when not in use LUBRICATION Your Lumex patient lift was designed with minimum maintenance in mind however a six 6 month check and lubrication should ensure that your patient lift will remain in peak operating con dition The casters MUST roll and swivel freely Lightweight waterproof grease such as automobile lubricant should be applied to the ball bearings of the casters every six 6 months Apply grease more frequently if the casters are exposed to periods of excess moisture Lubricate all pivot points with lightweight oil Clean patient l
6. should be removed before washing The slings can be dried by using a dryer on LOW heat or by hanging 4 CAUTION DO NOT bleach slings LF1030 ONLY INSTALLATION OF 10108005 HYDRAULIC PUMP Removal of Existing Pump 1 Follow the instructions in this upper boom lower mast E bracket 5 existing pum bracket section to remove the existing 9 pump pump shown at near right If installing pump for the first time proceed to INSTALLATION OF NEW PUMP 2 Detach the top of the existing pump from the upper boom bracket as shown at mid right Use two 9 16 wrenches to remove the hardware that secures top of pump to upper boom bracket This will free the pump to rotate downward 3 Detach the bottom of the existing pump from the lower mast brack et as shown at far right Use two 9 16 wrenches to remove hardware that secures bottom of pump to lower mast bracket This will free the pump take care that it does not fall LF1030 INS LAB RevB10 17 Installation of New Pump Note The hardware for attaching the Hydrau lic Pump GF 10105005 to the LF1030 mast and boom comes with the lift frame 1 Attach the bottom of the new hydraulic pump to the lower mast bracket with the pressure knob and pump lever toward the bottom of the pump as shown at near right and the FRONT label toward you as shown at far right Use a hex bolt washers and hex nut to secure pump to mast Use two 9 16 wrenche
7. the pump handle elevate boom LF1030 INS LAB RevB 10 10 Note Steps 10 13 apply to LF1040 Electric Patient Control box Lift only Cap screw 10 Attach control box using 5mm cap screws as B shown at right Battery charger Cap screw 11 Attach battery charger using 5mm cap screws as shown at right 12 Clip battery onto unit 13 See following Electrical connections section Eu A attach battery charger Electrical connections LF1040 only The control box is the heart of the electrical system into the control box plug the hand control battery and battery charger depending on battery charger options Ensure that all plugs are seated firmly in the proper receptacles When standing behind the patient lift the hand control connection is on the far left of the control box Ensure that the marks on the control box and the hand control plug are aligned and then firmly insert the hand control plug Immediately to the right of the hand control connection is the motor connection Insert the hand control plug firmly in its receptacle this plug has nothing to align Charging the battery LF1040 only The battery used on the LF1040 has an audible alarm that sounds when the battery charge has been depleted by 50 Charge the battery as soon as possible upon hearing this alarm Note This patient lift uses a lead acid battery Charge the battery fully before initial use To increase the longevity of the batt
8. 1030 INS LAB RevB 10 22 11 INDEX A Assembly instructions 8 B Battery care 16 Before each use 16 C Care and maintenance 16 Care of slings 17 CAUTION statement significance 3 Charging the battery LF1040 only 11 Checking for damage and wear 17 Cleaning 17 Components 8 E Electrical connections LF1040 only 11 Emergency procedures LF1040 only 12 F Features 6 H Handling Procedures 7 Hydraulic Pump 10105005 Installation LF1030 only 17 Inspection 7 Introduction 3 L Lifting the patient 13 Lifting the patient from bed 13 Lifting the patient from the floor 14 Lowering the patient onto a bed 13 Lowering the patient to the floor 14 Lubrication 16 Maintenance schedule 19 N Note significance 3 O Operating instructions 13 R Removing the sling 15 LF1030 INS LAB RevB10 S Safety precautions 4 Safety statements significance of 3 Shipping and transportation instructions 7 Specifications 20 Storage 7 T Transferring the patient from a bed to a wheelchair or commode chair 15 Transferring the patient from a chair to a wheelchair or commode chair 14 Troubleshooting 20 U Unpacking 7 V Videos instructional at www grahamfield com 13 Warnings 4 WARNING statement significance 3 Warranty limited 21 Weight capacity 4 USA Company Headquarters GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 USA tel 800 347 5678 770 368
9. 4700 fax 800 726 0601 678 291 3232 GRAHAM FIELD Made in Taiwan www grahamfield com
10. LLIIVIEX Graham Field Brand LF1030 HYDRAULIC PATIENT LIFT LF1040 ELECTRIC PATIENT LIFT USER MANUAL LF1030 INS LAB RevB10 2010 GF Health Products Inc Read this manual before operating your Patient Lift Save this manual for future use The most current version of this manual can be found online at www grahamfield com CONTENTS 1 3 2 SAFETY PRECAUTIONS deiwieas 4 lil crzem 4 3 FEATURES ec H 6 4 HANDLING cdi sc kd RAS Eas rv a i orca a 7 SHIPPING AND TRANSPORTATION INSTRUCTIONS eene nnn 7 5 ASSEMBLY INSTRUC TIONS vrccssciesictasssenticniatsdswnneecsescntvdcaababutstunieusbsteadneususadeecrareisdadenaueamiiabaneusonndn 8 COMPONENT S 8 ASSEMBLY qe r 9 b OPERATING INSTRUC TIONS usiiniatiabeskunn erani tai atc n ah Risa o ha eii caus 13 LIFTING THE PATIENT ERU CK C ia adsa FI UD UO RR GN EGRE 13 7 XSAREANDMAINTENANGCE acp ch HR a irr nil aio Ea Rr IA dE E
11. SLOW LY release the pressure knob by turning counter clockwise for gradual lowering of the patient Carefully lower the patient onto the bed Support the patient s head if necessary while being lowered Remove the sling by reversing the procedures used when lifting patient from bed LF1030 INS LAB RevB 10 13 Lifting the patient from the floor 1 Position the patient lift behind the patient placing a pillow over the base to protect and sup port the patient s head and neck Place the patient s head carefully on the base The patient lift should be positioned with the spreader bar centered over the patient 2 Lower the spreader bar Attach the sling to the spreader bar hooks 3 Lift the patient up above the floor Position the patient in the sling by pulling the handle on the back of the sling Turn the patient to face the lifting column and place the patient s feet on the base straddling the column for extra stability Lowering the patient to the floor 1 Place a pillow on the base to protect the patient s head and neck this is unnecessary when us ing a sling with a head support 2 Reverse the above procedures to lower Transferring the patient from a chair to a wheelchair or commode chair Note GF Health Products Inc recommends that two attendants be used when transferring a patient to and from a wheelchair 1 Fold the sling 2 While maintaining support gently lean the patient forward Place the folded sling
12. THER EXPRESS WAR RANTIES AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN AND THE REMEDY FOR VIOLATIONS OF ANY IMPLIED WARRANTY SHALL BE LIMITED TO THE REPAIR REPLACEMENT CREDIT AND OR REFUND OF THE DEFEC TIVE PRODUCT OR PART PURSUANT TO THE TERMS CONTAINED HEREIN GF HEALTH PRODUCTS INC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state province to province Some states provinces do not allow the exclusion or limitation of incidental or consequential damage or limitation on how long an implied warranty lasts so the above exclusion and limitations may not apply to you The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and understand ings with respect thereto The recipient of this document hereby acknowledges and represents that it has not relied on any representation assertion guarantee warranty collateral contract or other assurance except those set out in this document GF Health Products Inc Graham Field 2935 Northeast Parkway Atlanta GA 30360 Tel 800 347 5678 Fax 800 726 0601 LF
13. The emergency re lease should not be used in lieu of the hand control and battery LF1030 INS LAB RevB 10 12 6 OPERATING INSTRUCTIONS LIFTING THE PATIENT Z WARNING Do not attempt to transfer a patient without prior approval of the patient s healthcare professional and without having read the instructions and practiced using the patient lift N WARNING Use special care for those patients who cannot cooperate while being lifted Z WARNING Ensure all bolts hooks and loops are securely fastened N WARNING Use only Lumex slings with Lumex patient lifts Z WARNING DO NOT use torn cut frayed or broken slings as injury could result N WARNING Ensure the floor area is clear of any obstacle that could cause a caster to stop and possibly tip the patient lift Note Instructional videos that review the application of several sling styles and lifting sce narios are available at www grahamfield com Lifting the patient from a bed With patient face up in center of bed roll patient onto their side away from attendant Place sling folded lengthwise halfway under patient with lower edge just beneath knees Roll patient onto their side toward attendant pull sling to smooth it and center patient on sling Pull the leg loops forward and under the thighs Cross the loops one through the other ps Gia og Roll the patient lift under the bed locating the spreader bar over the patient Be careful not to lower the spre
14. ace the battery back on the patient lift Ensure that the tabs on the battery are fully engaged with the bracket The lift is now ready for use Emergency Procedures LF1040 only Emergency stop The control box is equipped with a red Emergency Stop button This button is to be used in the event the hand control ceases to function correctly To engage hit the button firmly with the palm of your hand The button will lock in the depressed position stopping all motor functions To disengage turn the button clockwise and it will return to its normal position Emergency lowering The motor is equipped with an motor Emergency Release which is located on top of the motor adjustment emergency as shown in the picture at right To engage pull up on the release which will disengage gearing in the cylinder and lower the patient The emergency release is adjust if able by turning the screw adjacent to the pull stem Turn the screw clockwise to increase and counter clockwise to decrease the sensitivity of the release mechanism Z WARNING Use caution when using the emergency release Pull back slowly on the release which will gradually lower the patient Pulling back too quick ly could cause the patient to be lowered too rap 4 idly which could result in serious injury Do not un der any circumstances use the emergency release for lowering the patient when the hand control and battery are operating correctly
15. ader bar onto the patient Center the spreader bar over the patient before lifting N WARNING Do not lock or block the patient lift casters when lifting The casters must be free to roll so that the patient lift can stabilize as the patient is lifted from the bed N WARNING To ensure stability while lifting or transferring a patient the patient lift legs must be locked in the maximum open position 7 Hook the sling loops onto the spreader bar 8 If the patient is in a hospital bed raise the bed s head section to elevate the patient 9 Raise the patient carefully If possible lower the bed Reposition the patient as needed using the handle on the back of the sling to ensure a safe and comfortable sitting position as the patient is raised 10 Raise the patient until the buttocks are just above the mattress Lift the patient s legs and turn the patient to face the lifting column Move the patient lift away from the bed Ensure that the patient s arms and legs clear the patient lift bed or any other obstacles Lowering the patient onto a bed 1 Raise the patient lift until the patient s buttocks are above the surface of the bed Ensure that there are no obstacles underneath or around the bed Move the patient lift under the bed Ensure the patient does not hit any portion of the bed and that the patient s legs have cleared the bed 2 Center the patient over the bed and rotate the patient to face the foot section of the bed
16. as identification or if the product is not serialized lot number and date code within thirty 30 days of return authorization issue date In the event you do not receive satisfactory warranty service please contact GF Health Products Inc the address below DO NOT return products to our factory without prior authorization LIMITATIONS AND EXCLUSIONS The foregoing warranty excludes consumables such as filters and tubing as these require routine maintenance The foregoing warranty shall not apply to serial num bered products if the serial number has been removed or defaced Products subjected to negligence abuse misuse improper operation improper maintenance improper cleaning improper storage or damages beyond GF Health Products Inc s control are not covered by this warranty and that evalua tion shall be solely determined by GF Health Products Inc This warranty shall not apply to problems arising from normal wear and tear or failure to follow instructions The warranty shall also not apply to products modified without GF Health Products Inc s express written consent nor shall it apply if parts not manufactured by GF Health Products Inc or if parts not complying with original equipment specifications are added to GF Health Products Inc products or if the product or part is serviced by an entity not authorized by GF Health Products Inc LF1030 INS LAB RevB10 21 THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL O
17. behind the patient s back and push it down until it touches the seat of the chair 3 Use the loops to pull the leg sections of the sling forward and beneath the patient s thighs Then cross the loops one through the other Move the patient lift around to the front of the chair Hook all sling loops onto the spreader bar Carefully raise the patient The second attendant should now move the wheelchair into position pe cp Se oe Engage the wheelchair wheel locks to prevent movement N WARNING Before transfer ensure wheelchair wheel locks are in locked position Wheel chair wheel locks must be in a LOCKED POSITION before lowering the patient into the wheelchair or unexpected wheelchair movement could result which may result in seri ous injury to both the patient and the attendants 9 Position the patient over the wheelchair with their back against the back of the wheelchair 10 SLOWLY lower the patient into the wheelchair 11 With one attendant behind the wheelchair and the other operating the lift the attendant be hind the chair should pull back on the handle or sides of the sling to place the patient into the back of the chair This will maintain a good center of balance and prevent the chair from tip ping forward gt lt gt lt lt lt m sm er LF1030 INS LAB RevB10 14 Removing the sling Gently pull the leg se
18. ctions to the side out from under the patient s thighs Standing by the pa tient s side lean the patient forward while supporting the patient with one hand Pull the sling up from behind the patient s back and position the patient in the chair Z WARNING Pulling sharply on the sling may cause the patient to fall forward resulting in personal injury Always support the patient by keeping one arm around the patient s shoulders when placing or removing the sling Note If possible the patient should be encouraged to take an active part in removing the sling The patient can lean forward lift their thighs and help in removing the leg sections Transferring the patient from a bed to a wheelchair or commode chair 1 For smooth easy lifting have the wheelchair or commode chair in ready position with wheel locks in locked position With patient face up in center of bed roll patient onto their side away from attendant Place sling folded lengthwise halfway under patient with lower edge just beneath knees Roll patient to side toward attendant pull sling to smooth it and center patient on sling Pull the leg loops forward and under the thighs Cross the loops one through the other iS oe Gey With base of lift under bed SLOWLY release pressure knob by turning counter clockwise and pull down boom Attach sling to spreader bar 9o Turn pressure knob clockwise until tight and lift the patient by operating the pump handle 9
19. d any part of these warnings cau tions or instructions contact a healthcare professional for direction in the use of this product If the Lumex Patient Lift is not properly assembled personal injury and damage to the Lumex Patient Lift could result N WARNING If components are damaged or missing contact your dealer immediately DO NOT use substitute parts Use only Lumex replacement parts The use of non Lumex re placement parts could cause personal injury property damage and void the warranty N WARNING The LF1030 Hydraulic Patient Lift LF1040 Electric Patient Lift maximum weight capacity is 400 pounds DO NOT exceed the maximum weight capacity N WARNING GF Health Products Inc assumes no responsibility for any damage or injury caused by improper assembly or use of this product N WARNING Check all parts for shipping damage before using In case of damage DO NOT USE the equipment Contact the carrier or your authorized Lumex dealer for further instructions N WARNING Patient lift may tip over if used incorrectly Read and adhere to the operating instructions prior to lifting anyone N WARNING GF Health Products Inc strongly recommends that two caregivers take part in the lifting process N WARNING When transferring a patient always keep the patient centered over the base N WARNING This patient lift is designed for transfer only It is not intended to be used for transporting or moving a patient from one locat
20. d the warranty and may result in damage to the unit Consult your Lumex Dealer for further information N WARNING LF1040 Electric Patient Lift only The electronics and actuator contain no serviceable components If service is required the unit must be returned to the factory for repair DO NOT attempt to open the electronics or actuator or obtain local service this will void the warranty and may result in damage to the unit Consult your Lumex Dealer for further information N WARNING Use extreme care caution and common sense when utilizing a patient lift Special attention must be given to patients who are disoriented and cannot cooperate while being lifted such as comatose agitated spastic or mentally confused persons Consult their healthcare professional for assistance in lifting these types of patients N WARNING Lumex specifically disclaims responsibility for any bodily injury or property damage which may occur during any use which does not comply with federal state or local laws or ordinances LF1030 INS LAB RevB10 5 3 FEATURES LF1040 Electric Patient Lift Battery battery charger amp control box LF1040 Electric Patient Lift only Boom Actuator LF1040 Electric Patient Lift only 2 4 spreader bar suspension Hydraulic pump LF1030 Hydraulic Patient Lift only See above left for LF1040 Mast LF1030 INS LAB RevB 10 Electric Patient Lift co
21. ery keep the battery fully charged when not in use Battery charging time is approximately four hours N WARNING After the alarm sounds there could still be sufficient battery power left to lift a patient Be aware that a lifted patient cannot be lowered when the battery is dis charged Refer to the Emergency Procedures section that follows for discharged battery operation LF1030 INS LAB RevB10 11 Charging the battery with lift mounted battery charger With control box battery charger and battery assembled insert the battery charger plug into a standard 110V receptacle A green light signifying power and a yellow light signifying that the battery is charging will illuminate on the bat tery charger When the battery is fully charged the yellow light will shut off The lift is now ready for use Note The patient lift will not operate during lift mounted battery charging Charging the battery with wall mounted battery charger Remove the battery from its bracket on the patient lift by placing your hand on top of the battery curling your fingers behind the battery and pulling up on the metal handle Pull the battery up and toward you to remove Place the bat tery on top of the wall mounted battery charger A green light signifying power and a yellow light signifying that the battery is charging will illuminate on the battery charger When the battery is fully charged the yellow light will shut off When battery charging is complete pl
22. ift of all excess oil and grease Before use of the patient lift and every two months thereafter place a drop of oil on the following areas The point where mast and boom connect e Spreader bar hooks e Pump handle hinge e Caster axles e The point where pump and boom connect LF1030 only The point where actuator and boom connect LF1040 only LF1030 INS LAB RevB 10 16 CLEANING Regular cleaning is recommended A soft cloth dampened with water and a mild NON ABRASIVE detergent household cleaner soapy water or hospital grade disinfectant is all that is needed to clean your patient lift Automobile wax or furniture polish will help maintain the finish over a long period of time A CAUTION DO NOT wash under water pressure or steam clean CHECKING FOR DAMAGE AND WEAR It is extremely important to frequently check the areas of the patient lift that are under a great deal of stress for damage and wear These areas include slings spreader bars spreader bar suspension and mounting hardware pump mounting hardware and all pivot points Inspect for signs of crack ing fraying deformation and any loose components 4 CAUTION Replace any defective parts immediately and make certain that the patient lift is not used until repairs are made Contact your authorized Lumex dealer for replacement parts CARE OF SLINGS Lumex slings are washable at 150 F and autoclavable at 185 F for 30 minutes The head support s plastic insert
23. ion to another N WARNING Never use the patient lift to lift or transfer anything other than a person N WARNING Ensure that lifting sling loops are correctly attached to the hooks to prevent the patient from sliding or falling out of the sling which could result in personal injury Ensure that sling grip handles are always positioned away from the patient so that the smooth side is facing the patient N WARNING Do not lock or block the casters when lifting The casters must be free to roll so that the patient lift can stabilize as the patient is initially lifted from a chair bed or any stationary object N WARNING To ensure stability while lifting or transferring a patient the patient lift legs must be locked in the maximum open position N WARNING Replace any worn or broken parts immediately Torn cut frayed or broken slings can fail resulting in personal injury Use only slings that are in good condition LF1030 INS LAB RevB10 4 A WARNING Unauthorized modification of your patient lift or the use of non Lumex re placement parts may change the structure of the lift and could create a hazardous con dition which may result in serious injury and will void the warranty N WARNING LF1030 Hydraulic Patient Lift only The hydraulic pump is sealed at the fac tory If service is required the unit must be returned to the factory for repair DO NOT at tempt to open the hydraulic pump or obtain local service this will voi
24. lations on your purchase of a Lumex patient lift The following pages will provide you with important safety and operating instructions on the use of patient lifts slings and accessories as well as maintenance and warranty information Read this manual carefully before operating your patient lift and refer to it as often as needed Consult your Lumex dealer and or healthcare professional with any questions or concerns regarding safe and effective techniques for operating your patient lift The Lumex Patient Lift is intended to aid in the transfer of an individual who is unable to indepen dently transfer between bed chair wheelchair and or commode DO NOT attempt any transfer without prior approval of the patient s healthcare provider With their assistance select the sling that best serves the needs abilities comfort and safety of the per son being lifted It is important that you use correct slings adapted to the body shape and weight and ability of the patient and the specific type of transfer needed Upon receipt of the patient lift and prior to each use inspect it closely to ensure that nothing is damaged there are no loose or broken parts that all patient lift parts are in the proper place etc Immediately replace any worn or broken components Your patient lift should receive maintenance on a regular schedule and should be inspected daily for proper operation Contact your Lumex dealer for service and repairs Before lifting an
25. ling hook for wear or deflections o L x X Inspect all spreader bar hardware for wear EE X Sings S O Inspect slings and straps for wear or damage Jx T Inspect metal plastic parts for wear or damage d x Jo Lubrication with light oil Lubricate al pivotpoints J T Tx Lubricate top and bottom of actuator mounting D lx Cleaning S O Ckanwihmidmonaasvedeegen J 1 Tx Pump LF1030 only Ensure that pump mounting hardware is igt X J X Inspect pump mounting haraware for wear 1 X Electronics and actuator LF1040 only that battery is fuy charged X X Inspectforproperup downoperation x x J fj Ensure that mounting hardwareistight X X inspect mounting harawareforwear 1 X LF1030 INS LAB RevB10 19 8 TROUBLESHOOTING Z WARNING If you experience a problem with your lift and are unable to service it your self contact your Lumex dealer LF1030 HYDRAULIC PATIENT LIFT SYMPTOM POSSIBLE CAUSE ACTION Patient lift does go Air in the cylinder Bleed the cylinder by turning the release or down knob and push down on the mast Pump up the lift again and turn the release knob again Loss of hydraulic fluid leaking Replace any leaking cylinder cylinder Patient lift does not go Air in the cylinder See above Directions
26. mences on the first date a product is delivered to consumer by seller dealer If the product is rented or leased the warranty period commences on the invoice date from GF Health Products Inc A copy of the invoice showing date of purchase must be provided when submitting warranty claims When proof of purchase date is not provided warranty coverage shall commence upon GF Health Products Inc s invoice date to the dealer purchaser If within the warranty period the product or component part is proven to GF Health Products Inc s satisfaction to be defective GF Health Products Inc shall provide at its option one of the following 1 repair or replacement of any defective or nonconforming part or product or 2 a credit and or refund of the original selling price GF HEALTH PRODUCTS INC S SOLE OBLIGATION AND YOUR EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE LIMITED TO SUCH REPAIR REPLACEMENT CREDIT AND OR REFUND This warranty does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to the manufacturer For warranty service please contact the authorized distributor from whom you acquired your GF Health Products Inc product Upon receiving notice of an alleged defect in a product GF Health Prod ucts Inc will issue a return authorization The defective product or part s must then be returned at the purchaser s cost for warranty inspection using the serial number
27. mponents Push handle Base adjustment handle Locking casters J Adjustable base LF1030 Hydraulic Patient Lift LF1040 Electric Patient Lift unless otherwise specified callout applies to both lifts Swivel casters 4 HANDLING PROCEDURES SHIPPING AND TRANSPORTATION INSTRUCTIONS If the patient lift is to be reshipped by common carrier it should be packed in the same carton s in which it was received the LF1030 is shipped in one carton the LF1040 motor may be packaged separately from the frame Unpacking 1 Check for any obvious damage to the carton or its contents If damage is evident notify the car rier or your authorized Lumex Dealer 2 Remove all loose packing from the carton 3 Carefully remove all the components from the carton Note Unless the patient lift is to be used immediately retain boxes containers and packing material for use in storing until use of patient lift is required Inspection 1 Examine the exterior of the patient lift for nicks dents scratches or other damage 2 Inspect all components Storage 1 Store the repackaged patient lift in a dry area 2 DO NOT place other objects on top of the repackaged patient lift LF1030 INS LAB RevB 10 7 5 ASSEMBLY INSTRUCTIONS The LF1030 patient lift is packed in one carton The LF1040 motor may be in a separate carton Components are shown in illustration below and called out in list below illustration COMPONENTS
28. s to tighten pump to lower mast 2 Attach the top of the hydraulic pump to the upper boom bracket as shown at right Use a hex bolt washers and hex nut to secure pump to boom Use two 9 16 wrenches to tighten A WARNING Ensure that the Hydraulic Pump is installed as described If the Hydraulic Pump is not properly installed personal injury and damage to the Hydraulic Pump could result Ye attach new pump to upper boom LF1030 INS LAB RevB10 18 MAINTENANCE SCHEDULE Note Only qualified persons should service and repair your Lumex patient lift Regular maintenance of your patient lift is necessary to ensure continuing proper and safe opera tion Read and observe the following recommended maintenance schedule Inspect Inspect adjust initially every 6 Sas mont meke Base Adjustments Ensure that base opens and closes smoothly Oox X X _Ensure that base locks securely in three positions x X Ensure that locking knob is in place and operating propery x x mspectal base hardware J 1 X Mast Ensure that mast is fully engaged and locked intomastsleeve x x Inspectmastforbendsordefletions J XT Lo x x Inspect all mast hardware for wear Boom Inspect boom for bends or deflections Ensure that boom is centered between the base legs Inspect all boom hardware for wear Spreader Bar Inspect hanger post for wear or damage X Inspect s
29. u ia 16 BEFORE EACH USE unisex eibi rre eb aasar araea DE EK DRM la Ra CR cile ud Da o fu 16 SINA nicer E E E E E E E 16 eee 16 CLEANING soisista ananena tite les a Ea we EE 17 CHECKING FOR DAMAGE AND WEAR uussssssunnrsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nannan 17 es cR ur cnp M 17 LF1030 ONLY INSTALLATION OF 10105005 HYDRAULIC 17 MAINTENANCE SCHEDULE 2 19 B TROUBLESFPIODUIIN O DM CHI 20 9 SPECIFICATIONS iiec ik vecbE FCU ranean LEN CIR HEP Fri wa Deque ICH EN KE SERM UE 20 10 LIMITED WARTUANT Y REED CNN CUIRE NEED RES USE VERE RTI PRNM UE 21 11 INDEX e n 23 GF Health Products Inc is not responsible for typographical errors Packaging warranties products and specifications are subject to change without notice Graham Field and Lumex are registered trademarks of GF Health Products Inc LF1030 INS LAB RevB10 2 1 INTRODUCTION Congratu
30. yone thoroughly read the instructions in this manual The operator should prac tice the entire lifting procedure several times with proper supervision and with a capable individ ual acting as patient It is extremely important to know how a patient will feel in the patient lift We suggest that the operator try all the various lifting slings and equipment until the operator is con fident with how the patient lift operates The lifting procedures should be explained to the patient before the actual lifting Remember that safety requires the constant attention of the lift occupant and the operator Use extreme care and common sense when operating a patient lift This guide covers the use of the LF1030 Hydraulic Patient Lift and the LF1040 Electric Patient Lift Keep in mind that the basic safety procedures included in this manual are to be used as a guide only You may find it necessary to develop your own unique methods for safely utilizing the patient lift Again consult your healthcare professionals for their recommendations and never hesitate to ask for their assistance Note Before attempting to assemble the patient lift refer to the section titled ASSEMBLY IN STRUCTIONS contained elsewhere in this manual Contact your Lumex dealer if additional assistance is needed Note In this manual the person being lifted is referred to as the patient or occupant and the person operating the patient lift is called the operator or
Download Pdf Manuals
Related Search
Related Contents
航 空 自 衛 隊 仕 様 望 仕様書の 内 容 に よ る 分 類 ” 装 備`品 等 仕 様 New Universe MP3 Sunglasses Dark Shadow Peerless TRF630 flat panel wall mount eFizz Travel™ User Manual Manuel d'utilisation eFizz Travel 取扱説明書 - アイオーテクニック Akupressurmatte Lucent Technologies MLX-16DPTM Marine Radio User Manual Philips USB Flash Drive FM16FD75B 要求水準書(案) 753001 P-440 User Manual WGS 21DEC2010.pub Copyright © All rights reserved.
Failed to retrieve file