1. This A C unit is to be used only for the purposes for which it has been designed and manufactured If used in other ways bad functioning or damages caused to people and or things are not responsibility of the Manufacturer Before starting with the installation you should assure that the unit has been purchased from an authorized Skipper dealer distributor the cartons contain all the items checked into the packing list the warranty certificate supplied with the unit ts filled out correctly In case of any bad functioning during operation please refer to the Troubleshooting section in this manual If the problem persists please contact your authorized dealer distributor 2 Safety consideration e Turn the main power source off when servicing when not using the unit for long time or in case of failure eDo not turn on the air conditioner if the filters are not installed in order to prevent dust and dirt to settle on it eA performance drop may occur due to blocking the airflow of the unit by obstacles to the air flowing in or out the air conditioner in the range of 1 meter in front or above it eDo not operate the air conditioner in cooling mode while using any heating device inside the cabin eDo not allow direct sunlight to enter the cabin while operating the unit nor expose the unit or the remote control to direct sunlight e Avoid the unit working when the boat is veering or with rough sea the excessive lateral or longitudin
2. Each operation on refrigerant circuit as well as cleaning void and recharging operations must be made exclusively by qualified technicians Electrical system all electrical components must be kept clean and dry Check periodically for electrical leaks which if detected must be immediately eliminated Winterizing the system when freezing temperature are expected it is necessary to drain all the water from the condenser the sea water pump the strainers and the connection tubing In details a close the seawater intake b remove the condensing unit inlet water hose c clean the strainer and drain completely the water inside it and inside the pump If the boat must be on land for more than 30 days allow all water to drain from the circuit to avoid corrosion due to the stagnation and let fresh water flow for some minutes Remember to discharge the circuit when launching for the connection of the pump 10 Troubleshooting In case of failure the COMEDE1 remote controller can stop unit operation listing by an alarm code the problem occurred For more details on this feature read carefully the pertinent COMEDE1 user s manual Most common failure are listed in the table below User s_manual_ENG_rev 06 09 11 The circuit braker is off____ Turn circuit braker on The unit doesn t aloo ow osas work The input line voltage is insufficient the dock or the manufacturer of the Dispersion of heat ___ lose all the windows Air filter
3. ball valve and it is necessary to close the sea water circuit in case of general unit maintenance and or strainer cleaning so that it is important to make it easily accessible The ball valve can be keep closed during winter operation which does not require sea water circulation Ball valve should be closed before the haulage of the boat in this way the pump will be full of water Check the opening of the valve after the launching and before using the unit Sea water pipe is then connected to the ball valve through the x20 mm male hose connector and stainless steel clamps The seawater circuit must be as short as possible without kinks or loops which could prevent the pump priming or increase pressure drops of water in the circuit with consequent loss of performance of the air conditioner The line between the water intake valve and the pump should be as short as possible The seawater strainer must be installed at the beginning of the intake line and properly situated to provide easy access for cleaning Check the arrow on the filter in order to assure the correct direction of the water flow through the strainer itself After cleaning always discharge air from the upper part of the strainer and check the right filling of the circuit The installation of the strainer is compulsory for the validity of the warranty in case of failure User s_manual_ENG_rev 06 09 8 The seawater circuit should always rise from water intake to the air con
4. _rev 06 09 6 shouldn t be close to exhaust or to any source of poison gas Do not put it in the bilge of the engine room Once drain discharge circuit installation has been ended try its efficiency filling the drain pan with water and verifying its flow 6 3 Air distribution circuit The inlet air grille must be installed as close as possibile to the air conditioner near to the floor to allow an uninterrupted airflow to the unit The inlet air grille can be placed opposite respect to the coil but in this case it is necessary to provide sufficient space around the unit to assure the proper air flow The air supply grille should be installed as higher as possible to create the ideal air flow into the ambient avoiding short cycling lt is important that the air flow is not oriented directly towards the inlet air grille or the thermostat The connection between the air blower and the circular air supply grille is made using the flexible duct and the PVC hose clamps included inside the installation kit The same clamps could be used for the connection of the duct to eventual pipe derivation tee max 1 used for the air distribution inside contiguous ambient For multiple outlet air grilles installation pls contact Thermowell Technical Department Take care of strictly tightening the clamps checking the absence of air leakages The duct should be positioned as straight as possible minimizing the number of the bend each bend reduces the air flow tr
5. al inclination of the boat could cause the loss of water from the condensate pan and the blockage or breaking of the compressors due to the non circulation of lubricating oil e Avoid the unit working while the in and out flow of the air is even partially obstructed on the contrary the electrical heater could damage itself irreparably e Never install the unit in the bilge or engine room e Always follow safety labels put on the air conditioner eCheck that the power supplied by the generator is sufficiently higher than the power required by the unit for operating 3 Unpacking the unit When the unit is received all items should be carefully checked against the following User s_manual_ENG_rev 06 09 3 packing list to ensure all cartons have been received and there are no damages If there is some shipping damage the carrier should make the proper notation on the delivery receipt acknowledging the damage It is necessary to send to Thermowell a photographic documentation of the damages within 10 days from the receiving of the unit otherwise the claim will not be accepted Self contained 1ZY air conditioner Electronic board with remote controller Flexible insulated duct diam 100 mm Round PVC air supply grille diam 100 mm PVC hose clamps for air duct 400x8 mm PVC inlet air grille 300x300 mm PVC tube with incorporated steel spiral int diam 18 mm Sea water strainer Male hose connector 1 2 x 18 Female hose connector 1 2 x 18 F
6. ditioner After the unit it can rise again or drop to the discharge part which must always be over the water line so that the circuit will be self bleeding The air conditioner has two hose fittings for the connection to the sea water circuit Seawater inlet and outlet are marked with labels The discharge side of the circuit should be made so that the water discharge will not cause excessive noise both for your boat and your neighbours but in such position to easily check for the proper water flow Sea water discharge is connected to the pipe by stainless steel clamps In case of new installation of sea water inlet or outlet or both it is suggested to install them on opposite sides respect to the keel so that sea water coming out from the air conditioner hotter is not directly sucked by the pump thus reducing performance of the whole system User s_manual_ENG_rev 06 09 9 7 Power supply Before any electrical operation it is necessary to disconnect the unit from power supply Electrical connections must be made by qualified technician or by people having necessary knowledge For the electrical connection of the unit please refer to the wiring diagram supplied with the unit Before electrical connections verify that voltage frequency and phase number available are compatible with those labelled on the unit Locate the Speedy air conditioner as near as possibile to the current tap If it is necessary to increase length of the
7. electric cable it is recommended to make use of a cable having a proper section and insulation according to the effective distance between the air conditioner and the general electric board To prevent a possible electrical shock which could result in serious injury or death always ground the system A circuit breaker is always required 16 A for 9 000 BTU h model 20 A for 13 000 BTU h model 8 Start up Before servicing the unit it is strongly suggested to check all the electrical and seawater circuit connections Cooling mode operation 1 Open the ball valve on the sea water circuit 2 Turn on the circuit breaker to the air conditioner 3 Turn on the air conditioner from the ON OFF button on the wall mounted or remote controller 4 Set the desired temperature to a lower value than the cabin temperature using the TEMP buttons arrow up to increase temperature arrow down to decrease 5 Check for the proper sea water flow by the sea water discharge or the strainer Heating mode operation 6 In heating mode is not required to open the ball valve 7 Turn on the circuit breaker to the air conditioner 8 Turn on the air conditioner from the ON OFF button on the wall mounted or remote controller 9 Set the desired temperature to a higher value than the cabin temperature using the TEMP buttons arrow up to increase temperature arrow down to decrease 9 Maintenance Air filter keep the air filters always clean by removing and was
8. emale female ball valve 1 2 Brass sea intake 1 2 Brass sea water drainage nozzle 1 2 x 19 mm Inox steel hose clamps for water pipe diam 17 32 mm Condensing water evacuation pipe 16x19 mm Power supply electrical cable Inox steel bracket Installation use and maintenance manual IZY air conditioner Installation use and maintenance manual remote controller COMEDE 1 Wiring scheme Warranty certificate Niaia 1 SS Simin NOL Ol gia ia 313 _ It is important to handle the unit upright at all times If the unit is not upright when received set it upright and wait until 24 hours before start it Deeply inspect refrigerant copper pipes inside the unit looking for fractures Evidence of refrigerant oil is indicative of broken refrigerant pipes 4 Factory inspection Thermowell tests and inspects all the units in its factory according to accurate internal standards Each performance test carried out on the unit is possible only if the same conditions are reproduced and maintained charge consistency constant evaporation and condensing temperature water and air temperatures quality and tolerance of the measuring instruments It is possible to check the units in their destination place only if the same conditions of the plant are reproduced and kept for the necessary time 5 How does it works IZY marine air conditioner is available in cooling only CO and cooling heating EH versions Cooling operation is made by conv
9. entional vapour compression cycle ecological refrigerant gas R407C through which is it possible to take heat from the cabin transferring to the sea water in details during summer operations the warm air of the cabin is blowed by the centrifugal fun through the coil circulated by low temperature User s_manual_ENG_rev 06 09 4 refrigerating gas In this way the air will be cooled before entering again the cabin An electrical pump properly dimensioned captures water from the sea and circulates it through the cupronickel heat exchanger producing here gas condensation Sea water temperature is highly influencing the performance of the A C In winter operations EH models only the air heating is made by an electric resistance put inside the blower compressor and sea water circulation pump do not work and the ball valve on sea water circuit can be closed In this way unlike reversing cycle systems the heating operation is not affected by the lower sea water temperature reached during winter season thus obtaining 100 heating efficiency also with sea water temperature below 10 C IZY operation mode is setted by the remote controller COMEDE1 more informations about operations setting are described in the proper manual 6 Installation diagram Thermowell s IZY marine air conditioning has been designed to operate over a wide range of operative conditions both for air and sea water temperature If it is required to operate the unit in particula
10. hing them twice a month or at least at the beginning of cold hot season It must replace once in a year Drain discharge Check periodically 3 4 times in a year that the condensate discharges are not clogged by dirtiness or other Sea water strainer The seawater strainer installed on seawater pump intake requires to be checked and cleaned periodically This strainer is absolutely necessary as it prevents the seawater pump and circuit to be clogged by dirty particles There is not a fixed rule to determine the periodicity of strainer maintenance which depends on the number of running hours and on the level of water pollution In cool mode a reduced water flow User s_manual_ENG_rev 06 09 10 reduces the efficiency and eventually causes a unit shutdown If the unit is used in the harbours when there is backwash or strong wind there could be an intake of dirty particles with following obstruction of the strainer Copper nickel heat exchanger Keep the copper nickel heat exchanger circuit sea water circuit always clean washing it with proper products once every two years This operation has to be carried out in preference by a qualified r technician Refrigerant charge each IZY unit is factory refrigerant charged R407C and tested Refrigerant charge should not need adjustment for all the life of the air conditioner Only in case of circuit broken or other leakage it needs to be recharged but only once the failure has been detected and repaired
11. ough the duct of a certain quantity The max length of the duct should be 2 5 meter The air conditioner is provided directly from the factory with a filter placed in front of the air return coil during installation of the unit consider for an easy accessibility to this filter for cleaning and or replacement see Maintenance section of the present manual Sometimes it could happen that the return air must be ducted too in such cases please contact Thermowell Technical Department 6 4 Seawater circuit For the seawater intake use 1 the Y brass sea intake supplied into the kit creating a dedicated water line 2 an existing seawater intake line not in use Please refer to the following picture for the correct installation of the sea water intake User s_manual_ENG_rev 06 09 PROW WATER DIRECTION BOAT DIRECTION It is strongly recommended to never intake the cooling water from the cooling circuit of the engine or of the generator The powerful self priming pumps of these systems would win the head of the seawater pump preventing its regular working If the installation of a new sea water intake is necessary it must be placed as close as possible to the keel and as far below the sea water level as possible thus reducing the possibility of air entering the circuit however it will not be dangerous since the sea water pump installed on the air conditioner is self priming The Y ball valve should be installed directly on the
12. rly heavy conditions pls contact Thermowell s Technical Department 6 1 Locate the air conditioner B OCCHETTA DI IMMISSIO NE CIRCOLARE CIRCULAR VENTILATING GRILLE COMANDO APARETE REMOTE CONTROLLER fp A J lt A NIN Hy ARIA CABINA SEA WATER DRAIN AGE AIRFROM CAB INE NOZZLE Each unit must be installed in a place easily accessible for maintenance reasons and which allows the proper air circulation at least 5 7 cm free space behind the return air User s_manual_ENG_rev 06 09 5 section The unit must be secured onto a flat horizontal surface using the supplied L shape inox steel brackets Insert the brackets on the rim of the condensate pan and secure by means of self tapping screws In order to make installation simplest it is suggested to definitely secure the unit only once air distribution sea water and drain discharge circuits has been completely installed Altough the air conditioner is very quiet in operation it is suggested to select the location for installation considering noise emissions It is suggested for example the installation into a locker rather than under a bed Using acoustic baffles is helpful in order to obtain maximum noise absorption even if the installation is under the berth The air conditioner is equipped already installed into the unit of a self priming sea water pump which allows the installation at a maximum height of 1 6 mt over the sea water line Higher distance
13. s may cause losses of performance of the unit and malfunctioning in the sea water pump in such cases ask for details to Thermowell Technical Department 6 2 Drain discharge circuit The running of the unit in cooling operation produces condensate water which is kept in a pan inside the unit and which must be drained and discharged overboard The condensate draining tubing must be connected to the 2 drain nipples of the condensate pan using supplied stainless steel clamps Take particular care when installing condensate drain circuit since the air conditioner can produce significative quantities of drain which if not properly evacuated can produce damages to the boat furniture It is possible to connect drain discharge circuit to only one drain nipple if so take care to properly seal the non used one Drain discharge pipe must be secured to the drain nipple with the supplied stainless steel brackets It is necessary to install the unit at a certain level to give a minimum slope to the discharge hose The draining hose should go down for at least 3 cm just immediately after the connection to the pan then going down without counterslopes along the line to the outlet port The overboard outlet port should be above the water line Where the overboard discharge is not possible you can drain into a bilge as near as possible to the strainer of the bilge pump In this case as the drain tube is in a depression the end of the tube User s_manual_ENG
14. s of the unit are clogged Rinse the filters with water and air dry The unit does Temperature setting Change the set point of temperature wrong for ex FAN or DRY Change the setting mode Fan speed a a al Heat sources Remove all heat sources The unit or the Remove and clean the strainer and check pump doesn t ae SANET is dirty ere IG AIr in he inlet duct discharge the seawate the seawater circuit work properly pump User s_manual_ENG_rev 06 09 Technical information in this manual are not binding Thermowell in his pursuit of a policy of constant development and upgrading of the manual may make any modifications without prior notice thermowell Thermowell Sede Legale Via Monte San Michele 26 73055 Racale LE Italy Sede operativa Via Olanda Zona Industriale 73100 Lecce Italy Tel 39 0832 300214 Fax 39 0832 300214 info thermowellmarine com service thermowellmarine com www thermowellmarine com User s_manual_ENG_rev 06 09 13
15. thermowell USER S MANUAL IZY www thermowellmarine com CONTENTS A A A A T pag 3 2 Sale ly COn idora ON aada aa OO E elena anaa A naneese i pag 3 SO a A A NO pag 3 ds We SUI Mata hc O se teancnen naam pag 4 Da ROWA S WOK a ds a diodosi pag 4 6 Installation Alarc n pag 5 Gol EOCate Meal GOMGIMIONG cesar tada pag 5 0 2 Daln da Isoharge CIRCUIN sak a A AA EEA pag 6 623 All GISUID UTIONY CIRCUIM a iia pag OF SOG Water circula ita is is eva anaemia dane a E Geen aci cada pag 7 Poti A e emer ae becuase no R pag 10 pA UD ests li e as ei pag 10 J Malena it aa a aweanecout pag 10 10 I FOUDICSIMOOUMNG a ens pag 11 User s_manual_ENG_rev 06 09 1 Preface Dear ship owner congratulations on your purchase of this marine air conditioning system which will assure high comfort levels in your boat Thermowell marine air conditioners are efficient powerful compact and affordable units You ll be satisfied by its advanced performances and latest technology Before starting installation it is strongly recommended to read this manual which is also basic and integrant part of the air conditioner carefully and completely because it provides important information to ensure proper installation operation and maintenance of the unit and to get the best performance from the unit Improper installation or operating procedures may cause unsatisfactory performances and or premature failure in the unit and or the boat