        ZoneMaster All-Mode Surge Suppressors Installation
         Contents
1.                                                    13 690                                                                                                                                                 Configuration and Schematic Connection Diagrams          12 400  4            a                                                           13 690               12 750                                                                                                                                                                                  Configuration and Schematic Connection Diagrams    277 480V THREE PHASE 4W WYE    Suppressor 13                Main  Feed             To  Equipment                                                   12 400            10 000                                                            13 690   13 690                                                                                                                       MAINTENANCE  At intervals not exceeding two months  check     l  Status indication lights  2  Conditions of connecting cables and terminals    Module Replacement       Unplug the remote contact connector at the top of the module  Remove  the mounting nuts at the top and bottom of the module  The protection  module can now be removed     WARNING  Replace the defective module with a module    having the same color label and voltage rating        Installation of the replacement module is the reverse of the above pro   cedure  Final step
2.   check that all cable connections are secure and  nuts are tightened  Do not overtighten     NOTE  No customer serviceable parts inside  Opening    module WILL void Warranty       10    11    Copyright 19969      The Wiremold Company  AII Rights Reserved    Patented No  5  311  393  Printed in U S A     801614 Rev C 7 15 08         
3. Installation  Instructions   amp  User Manual    ZONEMASTER                    AC Panel Transient Voltage Surge Suppressors     YY SENTREX   Power  amp  Data Quality Systems    The Wiremold Company   In US    60 Woodlawn Street  West Hartford  CT 06110  800 621 0049 FAX 860 232 2062   Outside U S   860 232 6251   In Canada    850 Gartshore Street  Fergus  Ontario NIM 2W8   519  834 4332 FAX  519  843 5980    INTRODUCTION  This document explains how to install the Wiremold ZoneMaster        Mode  AC Panel Surge Protection Devices     INSTALLATION INSTRUCTIONS   Warning  Terminals marked L1  L2  L3  N  GND  where relevant  must be  connected respectively to phase s  neutral and ground  Failure to comply  may result in danger or damage  See corresponding diagrams for proper  connections     INSTALLATION DESCRIPTION   ZoneMaster All Mode  units are connected in parallel  or in  shunt    across the supply to be protected  The connecting cable does not carry the  supply current  only the current associated with suppressing the transient  overvoltage     MOUNTING   The units should be mounted as close as possible to the panel to be  protected  See  page 4  on Connecting Lead lengths  Conduit  preferably  metallic  is    be installed from the suppressor to the panel  Drill holes  in the ZoneMaster All Mode  enclosure only in the designated areas as  shown in recommended cable dressing illustrations  page 5   Mount the  unit in the appropriate location using the mounting holes provide
4. connection diagrams for more details and mark   ings on unit if provided     RECOMMENDED WIRE GAUGE   STRANDED COPPER  Minimum of 8 AWG   Maximum of 4 AWG   for ease of dressing   Torque Rating  35   50 in   Ibs     LENGTH OF CONNECTING LEADS  The longer the connecting leads between the the ZoneMaster All   Mode   and power panel  the higher the residual transient voltage     RECOMMENDED MAXIMUM  500mm  197   IDEALLY  250mm  107     Each 250mm increase in cable length increases clamping voltage by  25V per 1000   surge current discharged        BIND THE PHASE NEUTRAL AND GROUND  CONDUCTORS TIGHTLY  OVER THE ENTIRE RUN  FROM THE SUPPRESSOR TO THE SERVICE  PANEL        ALWAYS USE THE SHORTEST LENGTH OF  CONNECTING CABLE POSSIBLE        RECOMMENDED CABLE DRESSING             CABLE   lt                          lt        ZoNEMAsTER                    Configuration and Schematic Connection Diagrams    120 240V SPLIT PHASE 3W    Panel  Suppressor L2          Main  Feed    To  Equipment                               je  12 400      12 400  4        10 000   10 000   16                                                  18 690   13 690      12 750         12 750                                                                                                                                                      Configuration and Schematic Connection Diagrams    120 208V THREE PHASE 4W WYE    Suppressor                                   12 400            12 400           10 000            
5. d on the  enclosure     INCORRECT INSTALLATION WILL IMPAIR THE  EFFECTIVENESS OF THE AC PANEL PROTECTORS   Particularly important is the length of the connecting leads  see pages  4  amp  5      Status INDICATORS  The Wiremold ZoneMaster All Mode   units have comprehensive  con   tinuous visual status monitoring present on each module        Status Full Reduced No No Power to   High N G  Indicated Protection    Standby  Protection Protector Voltage   Present Protection    LED Green Red Red Green Red  amp  Green  Indicator LED Lit LED Lit LED Lit LED Out LED Lit          Power Protection  Indicator    REMOTE INDICATORS   A remote indication of the reduced protection state is available as a nor   mally open or normally closed dry contact    Form        Rated maximum  1A at 30Vdc resistive and maximum 0 3A at 125Vac general use  Suitable  for connection of AVLV2 18AWG to 20AWG copper wire  Recommend   ed tightening torque  7 in   165     Routing of these wires should be separate from the power with a mini   mum of spacing of two inches      WARNING     OF HIGH NEUTRAL TO GROUND VOLTAGE    On certain models  if both Red and Green lights are on  consult a qualified  electrical contractor to check the integrity of the building wiring     CONNECTING LEADS   Connect the suppressor as shown in the installation diagram  Refer  to page 5 for recommended cable dressing  Connect the terminals  within the suppressor to the load side of 60A breakers or fuses within  the panel  See specific 
    