1. information on LED indicators 1 2 Operation Description Using the keyboard EKB1 the alarm is turned on or off entering the correct keyboard user code Factory default keyboard password is 1111 It is recommended changing it When the code is entered the system begins counting the time dedicated to leaving the premises The user is notified about the time countdown by a sound signaller integrated in the keyboard When the time is up a green LED lights and the alarm system switches to security mode To turn the alarm system off the user must enter user password again The user will be notified about a successful alarm turnoff by a sound signaller it will beep several times Also the green LED will fade off The user is notified about the turned night mode STAY by a yellow LED To turn on STAY mode it is necessary to configure the system accordingly using the program ESIM262 ConfigTool If the user does not open the door or in other words Z1 is not triggered after entering the code the alarm will turn to STAY mode when only the marked zones are secured The user is notified about this by the yellow LED STAY mode is useful when only particular zones are secured e g when the owner of the house is at home For instance only house perimeter only doors and windows are secured and the system does not react to the motion sensors inside the premises Red LED indicator shows that several zones have BYPASS mode turned on i e a particular z
2. eldes Keyboard EKB1 User Manual v1 0 The WEEE Waste Electrical and Electronic Equipment marking on this product see right or its documentation indicates that the product must not be disposed of together with household waste m Safety Information Please read and follow these safety guidelines in order to maintain safety of operators and people around e Don t expose the system to high humidity chemical environment or mechanical impact e Don t attempt to personally repair the system Any system repairs must be done only by qualified safety aware personnel The system must be powered by GSM system ESIM262 AUX output 13 8V Mains power must be disconnected before any installation or tuning work starts The system installation or maintenance must not be done during stormy conditions Manufacturer Warranty The system carries a 24 month warranty by the manufacturer ELDES UAB Warranty period starts from the day the system has been purchased by the end user The war ranty is valid only if the system has been used as intended following all guidelines listed in the manual and within specified operating conditions Receipt with purchase date must be kept as a proof The warranty is voided if the system has been exposed to mechanical impacts chemicals high humidity fluids corrosive and hazardous environment or other force majeure factors Copyright ELDES UAB 2009 All rights reserved It is st
3. nt changing all settings using ESIM262 Configuration TOOL To change the settings using the keyboard the user must first turn on service mode and after making the changes exit the mode The user will be informed about every successful command by a sound signal beeping several times In the case of failure or error it will beep once Description Command Possible val ues q 2 v pe v gt N N 47 W z 3 a c 5 L vi 0 Entering service mode Entering premises delay time Service mode PIN code change It is necessary exiting service mode after making configuration User manual EKB1 v1 0 7 Made in Lithuania www eldes It User manual EKB1 v1 0
4. o the wall 2 Disconnect security system ESIM262 power supply and backup battery before connecting wires 3 Connect keyboard connectors to ESIM262 Accordingly 12 V must be connected to AUX DATA to DATA GND to GND 4 Infix the keyboard into the holder 5 Turn on ESIM262 power supply Note If DALLAS key reader and or temperature sensor are connected to ESIM262 DATA connector used is the same I e all components containing DATA output must be connected in parallel ESC and ENT must be constantly lit If not all security zones are used it is necessary to use resistors with the unused zones Otherwise a red BYPASS indicator will light up even if a particular zone is turned off by SMS message or using configuration tool User manual EKB1 v1 0 5 BYPASS temporary zone disconnection To turn on BYPASS mode for any zone press the buttons in the following sequence ESC Zone_NO ENT E g to disconnect zone 5 press ESC 5 ENT Red LED indicator will light up immediately To turn off BYPASS mode enter analogous command sequence ESC 5 ENT The indicator will switch off Turning on BYPASS mode using the keyboard is analogous to the command sent by SMS message XXXX_Z 1 6 OFF User manual EKB1 v1 0 6 Service mode Factory default parameters are the following user PIN code 1111 Service mode code 1470 The user will be notified about the service mode actuation by a blinking red LED indicator It is most convenie
5. one is switched off This is useful if a specific sensor breaks down while the cause of the breakdown is being troubleshot The keyboard can indicate the security zone triggered at that time E g if the number five is blinking zone No 5 has been triggered The user can configure the system using the keyboard if he she knows administrator password The keys ESC and ENTER are always lit up Pressing any button will result in all keys illuminating for 30 seconds 1 3 Technical Specifications Electrical and Mechanical Characteristics Supply voltage 13 8 VDC from ESIM262 AUX output Current used not more than 150 mA when all LEDs are in operation Wea connection cable length keyboard connection cable length Dimensions 140x100x18 mm Operating temperature range 0 55 oC User manual EKB1 v1 0 4 1 4 Connector and LED Indicator Functionality Fig No 1 a a G J 12V DATA GND STAY w ARMED ee 1 2 3 BYPASS ee 4 5 6 7 a 3 ESC ENT g o LEDs STAY STAY perimeter security state indicator ARMED ARMED armed security status indicator BYPASS BYPASS temporary zone disconnection status indicator Connector Functionality Positive supply pin 12 14 VDC connected to the main unit AUX DATA Data pin connected to the main unit DATA Negative supply pin connected to the main unit GND COM 1 5 Keyboard installation and configuration 1 Fix the keyboard holder t
6. rictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from ELDES UAB ELDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this GSM ALARM AND CONTROL SYSTEM ESIMO51 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes It ce User manual EKB1 v1 0 2 Package Content 1 Keyboard EKB1 ccceeeeeeeeee ener ann 1pcs 2 Keyboard EKB1 holder 4 4444 1pcs 3 EKB1 user manual sssssssesrsrererrerrrrrrrree 1pcs About User Manual Quick Start This document describes keyboard EKB1 and its connection to security and alarm system ESIM262 It is very important to read User Manual before start using the system Content ae ESKE o a EE AEE A A AT ATARE 1 6 1 2 Operation Description i 1 3 Technical Specifications eeeeeeeeee n 6 1 6 1 7 4 Connector and LED Indicator Functionality ann 5 Keyboard Installation and Configuration cccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeee User manual EKB1 v1 0 3 1 General Information 1 1 Function EKB1 is a microcontroller based device intended to use with security and control system ESIM262 Its function is turning on or off the alarm entering data and show ESIM262
Download Pdf Manuals
Related Search
Related Contents
MANUAL DE INSTRUCCIONES RA Series Price Computing Scale みなかみ町の空間放射線量は安全です Structure-Conveying Modelling Language SML User's Guide リスクマネジメントサービス Samsung SP-D400S Priručnik za korisnike PH 260 Hobel/Profilierer - bei Logosol Deutschland Porter-Cable HL5211 User's Manual Canon IXUS 95 IS Digital Camera User Manual Copyright © All rights reserved.