Home

CO-911-4-8 user manual

image

Contents

1. Press one time 2s two times 4s and so on Automatically dial to branch phone with the function 4 Microphone 5 Connect to telephone terminal wireless telephone or answer machine 6 7 Connect to DC 12V power wire red cable to positive electrode and connect black cable to negative electrode 8 9 Signal triggering line Regardless electrodes while connected to N O or N C joint While used for 12V voltage input wire yellow or blue cable to positive voltage green cable to negative voltage 3 Set triggering signal a Open back cover b See jumper blocks J1 J2 J3 on circuit board adjust triggering signal and telephone system according to attached picture eee Reet niratea uae TONE N CAN O VOLTAGE IE d2 43 mi mi mi i mem o m E V LTAGI Picture 1 TEL Parallel telephone Picture 2 View from the back cover c Triggering signal please select jumper position according to alarm system host or triggering output contact point of sensors detectors i N C input put both J2 and J3 on left li N O input put J2 on right and J3 on left lil Voltage input put J2 on left and J3 on right d Close the back cover after setting 4 Operation procedures Enter self diagnosis after start up Enter self testing after starts up and then enter working state decimal point on the lower right corner of LED monitor flashes If alarm information is saved AUTO DIALER will make alarm as soon as
2. receives alarm signal If user wants to program or update set please preset and inquire phone numbers code password record and play record on the following steps 1 Enter programming state Press P private code 4 digits ENTER Note Initial code password 0911 For example Operation for enter programming before password saved is as followings P 0911 ENTER If code input is correct 5 will display and enter programming state if code input is incorrect E will appear means error and return to running state Input again following the above steps 2 Save the 1 group numbers Under programming state 5 displayed a Example number is 28055551 operation E1 gt 28055551 ENTER Start store number when the ENTER input in If 0 displayed means a correct input and then return to state 5 User can input it again in state 5 Operation for deleting the 1 group number is E1 ENTER b If alarm to voice automatic answer center first and not transferred by operator but turn to branch phone suppose branch phone number is 12 save operation is E1 28055551 P 12 ENTER c Hold 2s press one P press 2 times hold 4s operation for save the 2 3 4 5 6 7 and 8 group number is the same with the 1 3 Inquire the numbers saved Under programming state 5 displayed pulse 3 will display means CHECK and then pulse E1 E2 E3 E4 E
3. 5 E6 E7 E8 or P numbers will display Operation 3 gt 1 E2 E3 E4 E5 E6 E7 E8 or P display numbers saved and hear a Du voice after display 4 Save and play alarm voice a CO 911 can save 10 or 20s voice record Under programming state 5 displayed pulse 1 displayed means record begin record Operation steps 1 start talking record hear a Du voice finish record and stop automatically when time over b Play alarm voice Under programming state 5 displayed pulse 3 and then 2 P displayed means PLAY play recorded voice Operation steps 3 2 play the record hear a Du voice stop automatically after play over 5 Selectable alarm means and times CO 911 support 3 selectable triggering dialing alarm means Under programming state 5 operate as following a After triggering circling dialing 1 7 times to the saved E1 E4 numbers and then automatically stop Initial setting 5 turns Operation 6 1 choose circling times 1 2 3 4 5 6 7 ENTER Note Pulse 6 monitor display L means load displayed means choosing the 1 kind dialing alarm means when pulse 1 b after triggering circling dialing unstop following E1 E4 sequence until triggering signal reset to original state and stop automatically Operation 6 2 ENTER Note Monitor display means to choos
4. PSTN AUTO DIALER Microcomputer auto alarm dialer CO 911 1 Electrical Characteristic eOperating voltage DC12V to 15V eStatic current 50mA operating voltage DC12V eOperating current 150mA MAX operating voltage DC12V eDialing means PSTN cable network DTMF dialing e Triggering mode N C N O and voltage signal 3 selectable triggering dialing alarm means eRecord time 10 or 20s phone numbers and voice record will be saved even if it s powered off ePhone numbers can preset 4 or 8 groups 16 digits for one group at most ePassword protection 4 digit private code can withdraw alarm and program elnitial password 0911 eSupport voice alarm 2 External view COPHONE 911 AUTO DIALER la oh Ri Se Note If the dialer you chose is 8 group of numbers storage one there are four more buttons from E5 to E8 settled in this surface The model type is CO 911 8 1 LED display display the number input while save phone numbers 2 Indicators for phone numbers E1 indicator on while set E1 phone mobile phone numbers E2 indicator on while set E2 phone mobile phone numbers E3 indicator on while set E3 phone mobile phone numbers E4 indicator on while set E4 phone mobile phone numbers Note E1 E2 E3 E4 indicators on while setting password 3 P key has following functions a Save 4 digits password b While used for SPC telephone central exchanges system can take it as pause button
5. e the 2 alarm means c After triggering circling dialing persistently following E1 E8 sequence until stop by inputting password operation 6 3 gt ENTER Monitor displays while pulse 3 means choose type dialing alarm Note 1 The above alarm means can choose one only but If 1 2 3 is not chosen after pulsing 6 and directly pulse ENTER The above operation will make system return to producing default set The 1 dialing means circulate 5 turns 2 After triggering in alarm state In case a above automatically stop after finish dialing In case b above continuous dialing reset restore triggering signal if want to stop dialing In case c above If user want to stop dialing just input password 3 Please remove alarm host alarm panel alarm before stop dialer dialing 6 Save and inquiry code a Save code password 4 digit private password Initial password is 0911 If private code is 1234 operations in programming state in state 5 press P gt 1 2 3 4 ENTER and hear a voice which means finish input Note private code must be 4 digits if less than 4 digits system will display E and enter state 5 User can input it following the above procedures b Inquire code Under programming state state 5 press 3 and then P monitor will display code Operation steps 3 P gt display passwo
6. rd and hear a voice Du after display over c If user forget password Open the cover and then pulse RESET in picture 1 Code will be changed to the initial one 0911 but voice short message will not lose 7 Matters needing attention For the above operations if user want to change the setting Only need to operate the same procedures to save the new setting under programming state state 5 Pulse ENTER to return to working state after finish operation If ENTER is not pressed and monitor display 5 programming state still it will fail to trigger Please install and use it following the instructions and reference to following suggestions a Correctly program alarm means see Item 6 in this instruction b Correctly locate jumper position according to triggering means see detail in picture 2 c Telephone line correct wiring 8 Stop alarm dialing AUTO DIALER will automatically alarm to the preset numbers while triggered If user wants to stop alarm dialing input iT 77 private code while o displayed Suppose code is 1234 1234 will be displayed after input If code is correct alarm will be withdrawn after hear Du sounds For example code is 1234 operation steps after o displayed pulse ELZ BBP P Withdraw alarm Must input 4 digit correct password incorrect password fail to withdraw alarm input correct password again can withdraw alarm Please pay atten
7. tion Withdraw control host alarm system alarm and then input private code to remove AUTO DIALER alarm while try to stop AUTO DIALER 911 dialing 9 Methods for directly use dialer without alarm host a Choose corresponding triggering means CO 911 can directly connect to detectors door magnets emergency panic button and power switch to form an independent alarm system b Arm press P 8 times before input phone numbers can delay 16 second delay 2s press 1 time only need to turn of power close the door and go out and switch power on system will enter warning state c Disarm within 16s after entrance accord to time set in 2 above remove alarm by input password or switch off power 10 Methods to remove common faults a Triggered but not dial to phone numbers saved phone line connect error or J1 position wrong b No trigger trigger means set error J2 J3 jumper position error c Dialing nonstop did not choose correct alarm means d Noisy while play record mostly because power supply problem

Download Pdf Manuals

image

Related Search

Related Contents

Plantronics 46186-01 headphone pillow  Manual de Instalación  CE2277MO User Manual - Oriental Pacific International  MASTER IFI par APPRENTISSAGE - Université Nice Sophia Antipolis  公募型指名競争入札について(変更)  Husky H4120 Use and Care Manual  MANUAL - quintiavio.com  Version 16 User's Guide  VMOD63 - Falcon Technical Ltd  Aiwa VX-S205U User's Manual  