wet bath checklist - Alcohol Interlock Curriculum

image

Contents

1. Use mild detergent to clean the top housing Use chrome cleaner for removing stains and heavy soils p 14 If algae or other abnormalities are noticed on the parts within the solution chamber use the following procedure o Use one tablespoon of Clorox per 1 gallon of water allow soaking for 3 6 hours followed by rinsing with COLD water then Air dry use of hot water could shock the thermostat and break the NIST thermometer p 14 Check to see if the fuse cap is secure DO NOT OVERTIGHTEN p 14 Replace the container gasket if uneven wear is noted it is recommended the gasket be replaced once a year p 14 Inspect the glass container threads for chips or cracks and replace if necessary p 14 Notes Citations Guth Laboratories Model 34C User Manual Alcohol Countermeasure Systems Reference Solution Recommendations BAIID Field Representative Wet Bath Simulator Assessment Office of the Secretary of State Jesse White BAIID Division 217 524 0660 Room 211 Howlett Building Springfield IL 62576
2. BAIID Division Calibration Review Guth Laboratories Model 34C Simulator Vendor Installation Site County Address Assessment Date Manager Installer Name Last Assessment Issues from Last Review Sealing of the Simulator When screwing the jar portion onto the head simulator do you moisten the rubber strip with certified solution to ensure the tightest seal Yes No When the device is not in use are the outlet hose and the blow tube connected to ensure that the integrity of the solution is not compromised Yes No o If not the alcohol content of the solution may dissipate Is the rubber grommet that encompasses the external thermometer cracked dry or out of tolerance Yes No o If so the integrity of the simulator may be compromised replace if air leaks Is there a tight seal between the glass container and the simulator s top housing Yes No Place finger over outlet hose and blow air through blow tube if you can see or hear air escaping then there is not a tight seal and the device may not be working properly have installer conduct this test Model 34 C Manual BSL p 1 o If the glass container s thread or rubber seal is cracked or chipped then replace Does the Vendor supply adequate solution if provided by Vendor Where is the unopened solution stored ACS Recommendations p 1 o It must be stored in a cool location with no extreme temperature changes and must not freeze p 1 How oft
3. en is the solution replaced Manually Count or Computer Tracks o If tracked by computer can ask installer to open up program to check countdown until solution needs to be changed When changing solution is the correct amount of new solution p 12 Is any of the solution out of date in the format of YEAR MONTH DAY Any time the offender brings their Interlock Device in for service the BAIID must be calibrated via Illinois Administrative Code 1001 442 Section D 11 does this occur Yes No Environmental factors i e deviations in temperature can affect the calibration process negatively If the device is not being used it should be stored somewhere at room temperature is this occurring Yes No p 1 Calibration How long does the machine warm up before calibrations are conducted p 12 o It will take approximately 15 minutes to reach the proper temperature p 12 o The heater lamp light will be OFF when the 10 4 has reached 34 C p 12 Do you ensure that the simulator is 34 C before any calibrations are performed Yes No p 12 4 If the installer must blow into the simulator for recalibration does he or she rinse their mouth out first o Additionally if the installer manually blows into the device solution will not last as long when compared to solution where an air pump is used in view of the fact that more moisture is introduced to the solution from the breath sample Cleaning and Preventative Maintenance

Download Pdf Manuals

image

Related Search

Related Contents

16 Recording primate vocalizations  Wireless Video Door Phone User Manual  

Copyright © All rights reserved.
Failed to retrieve file