XVRT User`s Manual - Xtreme Power Conversion

image

Contents

1. UNIX DOS WIN DOWS and other operating systems Xtreme Power Conversion Corporation Page 8 XVRT User s Manual Uninterruptible Power Supply Determining The Power Requirements Of Your Equipment 1 Make sure the total Volt Amp VA requirements of your connected equipment does not exceed the maxi mum VA rating for the UPS The maximum VA ratings are shown in the Specifications section of this docu ment 2 Ensure that the equipment plugged into the battery powered outlets does not exceed the UPS rated ca pacity If UPS rated capacities are exceeded an overload condition may occur and cause the UPS to shut down and trip the circuit breaker 3 If the power requirements of your equipment are listed in values other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The equation below only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any given time Users should expect usage requirements to be approximately 60 of the value to estimate power requirements Watts W x 1 67 VA or Amps A x 120 VA Add the totals for all of the equipment and multiply this total by 0 65 to calculate actual power require ments Note Many factors can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 85 of the UPS capacity Xtreme Power Co
2. K 1 Set User Account 1 2 Set User Account 2 3 Set User Account 3 4 Set User Account 4 lt 0 gt Return to previous menu Enter Choice gt gt E mail Setting Enter an 8 at the main menu the following screen will be displayed allowing you to setup SMTP server You have to setup it correctly so that the NETpower device can sent out mails when an event occurs NETpower SNMP agent adapter Configuration Email Parameter Setup SMTP Server IP Address 1 Set SMTP IP Address lt 0 gt Return to previous menu Enter Choice gt gt Xtreme Power Conversion Corporation Page 23 XVRT User s Manual Uninterruptible Power Supply Environmental Monitoring Module Enter a 9 at the main menu to setup the Environmental Monitoring Module You have to install Environmental Monitoring Module before setup Web and Telnet Service Setting Enter w at the main menu to enable disable Web Telnet service Enable Web Service when you want to monitor the UPS via a web browser Enable or disable Telnet Service to specify whether it allows users to login via telnet NETpower SNMP agent adapter Configuration Web and Telnet Service Setup Menu Web Service disable Telnet Service enable 1 enable Web Service 2 disable Telnet Service lt 0 gt Return to previous menu Enter Choice gt gt Upgrade Firmware Enter u at the main menu to upgrade firmware NETpower SNMP agent adapter Configuration Upgrade firmware 1 Upgrade firmware fro
3. Power indicator illuminates to add additional equipment Battery Auto Charging Once the input power cord is connected to AC the battery in the UPS will automatically be charged by the UPS To maintain the optimal battery status make sure the UPS remains plugged into AC input power The battery is fully charged before shipping However it is recommended that the battery be recharged for at least eight hours before using Energy loss may occur during shipping or long duration storage Equipment loads can be connected during this time however the battery capacity may not be 100 until charging is complete Connect Software Configure the UPSMON local monitoring software 1 Insert the UPSMON CD included with UPS packaging into the CD ROM of the local computer 2 Select the appropriate installation from the Autorun menu 3 Follow the setup instructions Click finish when prompted Ensure the checkbox to start UPSMON is checked before clicking finish 4 The UPSMON icon will appear in the system tray of the desktop near the system clock Double click this icon to enlarge the program window 5 Connect the USB or RS232 cable included in the UPS packaging to the Computer and UPS Communica tion should start momentarily If it does not click on Setup on UPSMON toolbar then select Comport and search computer ports CAUTION Please verify the UPSMON shutdown settings of the UPS and Local PC by clicking on System System configuration 6 Click
4. RECT SPECIAL INCI DENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF Xtreme Power Conversion EQUIPMENT including but not limited to any costs lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data cost of substitutes or claims by third parties Purchaser s sole and exclusive remedy for breach of any warranty expressed or implied concerning Xtreme Power Conversion equipment and the only obligation of XPC Corporation under this warranty shall be the repair or replacement of defective equipment components or parts or at XPC Corporations sole discretion refund of the purchase price or substitution of an equivalent replacement product Xtreme Power Conversion Corporation Page 19 XVRT User s Manual Uninterruptible Power Supply Appendix A SNMP Configuration Guide You must configure the Net Logic Card before it can operate properly You have two methods to configure the Net Logic Card Using telnet or terminal listed below to access the configuration screen Once the SNMP card is configured and you have accessed the SNMP web page you can view the user guide through the help section by clicking on the link to further configure the SNMP card to site parameters CAUTION A default setting of the SNMP card is to shutdown the UPS after 300 seconds when a utility power fail ure occurs Changes to this setting can only be made through the web interface after the initial configura
5. UPS UPS Attached Device NA Last Battery Replacement Date 12 31 1969 1 Set UPS Identification Name 2 Set UPS Attached Device 3 Set Last Battery Replacement Date Xtreme Power Conversion Corporation Page 22 XVRT User s Manual Uninterruptible Power Supply lt 0 gt Return to previous menu Enter Choice gt gt System Time amp Time Server Enter a 6 at the main menu the following screen will be displayed allowing you to setup System Time In this option you can setup the date and time for the Net Logic Card The SNTP Server and Time Zone settings are used for time adjustment Specify the SNTP Server and Time Zone and then choose 4 Adjust System Time to adjust your system time If the values retrieved from the Internet are not what you want you can still change the date and time manually NETpower SNMP agent adapter Configuration System Time amp Time Server Setup System Time 01 07 2003 11 08 37 Time Server IP Address 200 49 40 1 Time Zone 0 1 Set System Time 2 Set Time Server IP Address 3 Time Zone 4 Adjust System Time lt 0 gt Return to previous menu Enter Choice gt gt User Account Enter a 7 at the main menu the following screen will be displayed allowing yo u to setup user accounts those who can login to the Net Logic Card NETpower SNMP agent adapter Configuration User Account Setup Menu User name Password 1 dnpower 2 okok ok ok K ok OK ok 3 K K K K K K KK 4 28 K K K K K K
6. XVRT Line Interactive UPS 1000VA 1500VA 2200VA 3000VA Models User 8 Installation Manual www xpcc com 2015 Xtreme Power Conversion Corporation All rights reserved Rev 10 08 15 XVRT User s Manual Uninterruptible Power Supply Table of Contents NACH OC UC ON esco cim ame sanitat noses ioe sit E E mm tit 3 SOC EV IOS TUC OO NS ei ains 3 ProductDescriptonsiosiimi onm m y y mn massissos 5 Line Interactive Technology occcccccnccccnnnonnnnnononnnonononnnnnnnonnnnnnnnnnnnnonnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnnos 5 Determining The Power Requirements Of Your Equipment ssssccsesees 9 Hardware Installation Guide sscccssccssccsssccssccssccsssccscccsscessccnsscnsssessees 10 CONNECtioNS aNA StaltUP sererrrresersessooserrrrrrrreserrerrrr sr rrr rr rss rr rar ARR DKK ARR KKR KRK KR RR RAR RR RSK RR KKR KR KKR An 11 OtherFe SUC OPA on eis EO REE AEE E RN 12 Software And Computer Interface ccccsssccsssccssscccsscccsssscesssccsssceesseees 13 Power Monitoring SO tWAre cccccnnnoncononooonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nro nn KR RAR RR KRK RR KKR KR KKR Rn 13 Interface A O e UU RR RR RAR KRK KR RAR RK KKR dant A 13 BOUL SIGS A 14 Replacing The BatterlY sssssessesssoseoseoesereseesssrsorerrrrrrrrrs reser rar rn rr rss rs rr AR KR RAR RR RDR KRK KR KKR RAR RR RR RADAR ARR KKR 14 A 15 as o A 15 Specifications rd nara 16 A 17 Obtaining Service
7. ceptacl y peer Gls core TSR 6 5 15R 1 L5 15R 4 5 15R ENVIRONMENT Operating temperature 32 104 F 0 40 C Audible noise lt 40dBA Altitude 11 500 ft above sea level INDICATORS amp Battery backup Slow beeping sound ALARMS Battery low Rapid beeping sound Overload Continuous beeping sounds APPROVALS UL cUL FCC VVARRANTY 3 years electronics 1 year battery USA and Canada COMMUNICATIONS INTERFACE RS 232 bidirectional port RS 232 to USB cable to enable USB connection SNMP connectiv ity via external SNMP card device INCLUDED IN BOX 6ft USB DB9 adaptor 6ft DB9 cable UPSMON CD phone cord vertical brackets set hori zontal brackets user manual Xtreme Power Conversion Corporation Page 16 XVRT User s Manual Uninterruptible Power Supply Shipping List 1 UPS 1 User s and Installation Manual 1 power cord for XVRT 1000 amp XVRT 1500 1 6 ft USB DB9 adaptor cable 1 UPSMON CD monitoring software 1 phone cord for use with telephone data surge protection 1 set of vertical mounting brackets 1 set of horizontal mounting brackets Xtreme Power Conversion Corporation Page 17 XVRT User s Manual Uninterruptible Power Supply Obtaining Service If the UPS requires Service 1 Use the TROUBLESHOOTING section in this manual to eliminate obvious causes 2 Verify there are no circuit breakers tripped 3 Ca
8. ck The short circuit current capability of the battery is sufficient to burn wire or tools very rapidly producing molten metal Observe these precautions when replacing the battery 1 Remove all watches rings or other metal objects Only use tools with insulated handles Do not lay tools or metal parts on top of battery or any terminals Wear protective eye wear goggles rubber gloves and boots Power down the UPS and disconnect the charging source before removing covers Determine if the battery is inadvertently grounded If inadvertently grounded remove the source of the ground Contact with a grounded battery can result in electrical shock The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit 7 Disconnect the battery terminals to remove old batteries 8 Measure the DC voltage of the approved replacement batteries for the proper value 9 Install and connect new batteries ensuring proper polarity and voltage 10 Replace cover s reconnect AC source and restart the UPS Dr Oe US Xtreme Power Conversion Corporation Page 14 XVRT User s Manual Uninterruptible Power Supply Audible Alarms Alarm Indication Unit Status SLOW BEEPING SOUND ON BATTERY RAPID BEEPING SOUND LOW BATTERY CONTINUOUS BEEPING SOUND OVERLOAD Troubleshooting The UPS has a self protect feature that prevents the UPS from be
9. d e When AC input power returns the UPS automatically begins supplying the load with power through the AVR circuit e The charger circuit provides recharge for the batteries tL REL RELAY L INPUT gt OUTPUT RELAY MR BATTERY INVERTER Xtreme Power Conversion Corporation Page 5 XVRT User s Manual Uninterruptible Power Supply FRONT PANEL XVRT 1000 1U HEIGHT REAR PANEL XVRT 1000 1U HEIGHT Se 5 HEHEHHE L CSD usen Les FRONT PANEL XVRT 1500 2U HEIGHT REAR PANEL XVRT 1500 2U HEIGHT mm DVI E DD e FRONT PANEL XVRT 2200 XVRT 3000 3U HEIGHT Xtreme Povver Conversion Corporation Page 6 XVRT User s Manual Uninterruptible Power Supply REAR PANEL XVRT 2200 3U HEIGHT ate ase ve am ao o oum pen BATTERY FAULT AC NORMAL BATTERY IN USE XVRT 1000 FRONT PANEL XVRT 1500 2200 3000 FRONT PANEL Xtreme Power Conversion Corporation Page 7 XVRT User s Manual Uninterruptible Power Supply AC NORMAL or LINE MODE Indicator The AC Normal XVRT 1000 or Line Mode XVRT 1500 XVRT 2200 XVRT 3000 indicator illuminates when utility power s condition is normal BATTERY IN USE or INV MODE Indicator The Battery in Use XVRT 1000 or Inv Mode XVRT 1500 XVRT 2200 XVRT 3000 indicator illuminates when the power is supplied from the batteries BATTERY FAULT Indicator This illuminates indicating weak battery Recharge the battery
10. ff and unplug the UPS CAUTION Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and their required precautions Keep unauthorized personnel away from batteries and always replace batteries with the quantity and type See Page 15 of this manual for more safety details DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT Xtreme Power does not sell products for life support or medical applications DO NOT use these UPS in any circumstances that would affect operation or safety of any life support equipment or with any medical applications or patient care DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire or electric shock do not use with or near an aquarium Condensation from the aquarium can cause the UPS to short out Storage To store the UPS cover it and store it with the battery fully charged During extended storage recharge the battery every three months to ensure battery life Xtreme Power Conversion Corporation Page 4 XVRT User s Manual Uninterruptible Power Supply Product Description Many different kinds of sensitive electrical equipment can be protected by an Uninterruptible Power Supply UPS including computers workstations process control systems telecommunications systems sales terminals other critical instrumentation etc The purpose of the UPS is to protect these systems from poor quality utility power complete loss of power or other associated problems E
11. for at least four hours If after recharging this is still illuminated replace the battery by following the instructions in the manual BOOST Indicator This illuminates when input voltage is too low and the UPS is boosting the voltage via the Automatic Voltage Regu lation AVR circuit BUCK Indicator This illuminates when input voltage is too high and the UPS is lowering the voltage via the Automatic Voltage Regulation AVR circuit Power Switch The Power Switch can be used as the master on off switch of your equipment by leaving your equipment con nected to the UPS and switched on UPS Outlets The UPS Outlets provide instantaneous backup power protection to your equipment They can also be used to sup ply temporary uninterrupted operation for your equipment during a power failure Bypass Power Sag Outlets The Bypass or Power Sag Outlet provides bypass power sag protection to your equipment Prevent power prob lems traveling through your system via unprotected peripherals Circuit Breaker Protection The Circuit Breaker serves as an overload and fault protection a critical component of this advanced UPS Tel Data Protection Ports The Telephone Data Protection Ports provide users surge protection via 1 in 1 out RJ45 jack Caution To reduce risk of fire use only 26AWG or larger telecommunication line cord Communication Function A RS232 interface and UPSMON software is provided to support communications with NOVELL
12. ic equipment CAUTION Any changes or modifications not expressly approved by the manufacturer of this device could void the user s authority to operate the equipment FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device pursu ant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference in residential installation This equipment generates and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications There is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced technician for help Any special accessories needed for compliance must be specified in the instruction CAUTION A shielded type power cord is required in order to meet FCC emission limits and to prevent interference to the nearby radio or TV reception It i
13. ing damaged as a result of overheating If the temperature is higher than 55 C the UPS will shut down If this happens wait for several minutes for the UPS to cool down and then restart the UPS PROBLEM POSSIBLE CAUSE SOLUTION Turn the UPS off amp unplug at least Full time Bypass outlets stop pro Circuit breaker has tripped due to one piece of equipment Wait 10 viding power to the equipment an overload sec reset the circuit breaker on the UPS amp turn the UPS on Recharge the battery by leaving the Battery a charged UPS plugged in and switched on The power required by your equip ment slightly exceeds the capacity of the UPS I Contact Xtreme Povver Conversion The battery is defective or vvorn out about replacement of batteries The on off switch is designed to prevent damage by rapidly turning it off and on The UPS is not plugged into an AC Connect the UPS to an 110 120V The UPS will not turn on wall outlet 60Hz AC wall outlet The battery is defective or worn out a OA ton about replacement of batteries Mechanical problem Contact Xtreme Power Conversion Shutdown your load amp turn the UPS off Wait 10 sec amp turn the UPS back on This should reset the UPS The UPS does not supply expected runtime Unplug at least one piece of equip ment from the UPS outlets Turn the UPS off Wait 10 sec amp then turn the UPS on The UPS shuts down when there is The UPS is not providing battery loss of AC power po
14. ion Data b Reboot SNMP agent adapter s Save amp Reboot Exit Without Saving Enter Choice gt gt SNMP Agent IP Parameter To configure the SNMP agent IP parameters enter a 1 at the main menu The following screen will appear allow ing you to configure IP address Subnet Mask and Gateway NETpower SNMP agent adapter Configuration IP Parameter Setup My IP Address 192 168 1 254 Subnet Mask 255 255 255 0 Router Gateway IP Address 192 168 1 1 1 Set IP Address 2 Set Subnet Mask 3 Set Router Gateway IP Address lt 0 gt Return to previous menu Enter Choice gt gt MIB II System Group Enter a 2 at the main menu the following screen will be displayed allowing you to configure some important MIB II System Group items including system name contact person and system location NETpovver SNMP agent adapter Configuration MIB II System Group Setup Menu Current values for the follovving MIB II OID sysName NETpovver sysContact admin sysLocation 1 Set sysName 2 Set sysContact 3 Set sysLocation lt 0 gt Return to previous menu Enter Choice gt gt Xtreme Power Conversion Corporation Page 21 XVRT User s Manual Uninterruptible Power Supply SNMP Read Write Access Control Enter a 3 at the main menu the following screen will be displayed allowing you to setup the SNMP Access Control Enter the community number from 1 to 4 to specify a community string an IP address and the access privilege NETp
15. lectrical interference exists in many forms causing problems in AC power from lightning power company ac cidents and radio transmission motors air conditioners and vending machines Protection of sensitive electrical equipment is vital to protect against power outages low or high voltage conditions slow voltage fluctuations frequency variations differential and common mode noise transients etc To prevent power line problems from reaching critical systems causing damage to software hardware and equip ment malfunctions the UPS maintains constant voltage isolating critical load output and cleaning the utility AC power Line Interactive Technology A line interactive technology UPS provides basic power protection and Automatic Voltage Regulation AVR to the load when AC input power is available When AC input power is unavailable the line interactive UPS will switch to batteries to supply the load with power In the event that the power failure lasts longer than the UPS backup time the UPS will shut down avoiding battery damage When the input AC voltage returns the UPS will automatically return online to recharge the batteries As shown in the diagram e AC input flows into and through the AVR to the load e When AC input varies outside the acceptable specification the AVR switches taps on the transformer to better regulate the output e If ACinput power fails the inverter turns on an supplies power from the batteries to the loa
16. lly shut down and not restart until utility power is restored Check to assure power is available at the receptacle being used for input power Xtreme Power Conversion Corporation Page 12 XVRT User s Manual Uninterruptible Power Supply Software And Computer Interface Power Monitoring Software The UPSMON series software is used via a standard RS 232 interface to perform monitoring functions It can pro vide an orderly shutdown of a computer in the event of a power failure UPSMON displays diagnostic information on your monitor including Voltage Frequency Battery Level etc The software is available for DOS Windows 3 1x Windows 95 97 2000 ME XP Windows NT or later Novell Netware Linux and others Call your dealer for more information on computer OS compatible solutions Interface Kits A series of interface kits are available to provide UPS monitoring Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating systems recognize The interface cable must connect to the REMOTE PORT on the UPS and to either COM 1 or COM 2 on the com puter The communications port on the back of the UPS may be connected to a host computer This port allows the com puter to monitor the status of the UPS and control the operation of the UPS in some cases Its major functions include some or all of the following e To broadcast a warning when power fails e To close a
17. llyourdealerforassistance If youcannotreachyour dealer oriftheycannotresolvetheproblem call Xtreme Power Conversion Corp Technical Support at 800 582 4524 Technical support inquiries can also be made at support xpcc com Please have the following information available BEFORE calling the Technical Support Department e Your name and address e The serial number of the unit e Where and when the unit was purchased e All of the model information about your UPS e Any information on the failure including LED s that may or may not be illuminated e A description of the protected equipment including model numbers if possible e A technician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask the Technical Sup port Technician about obtaining a replacement set of packaging material It is important to pack the UPS properly in order to avoid damage in transit Never use Styrofoam beads for a packing material 2 Include a letter with your name address daytime phone number RMA number a copy of your original sales receipt and a brief description of the problem 3 Mark the RMA number on
18. m tftp server 2 Upgrade firmware from http server lt 0 gt Return to previous menu Enter Choice gt gt When you choose 1 the following screen is displayed asking you to input the tftp server and the filename of the latest firmware To make it work you must have a tftp server installed and copy the firmware file to the tftp server Input the tftp server address gt gt 192 168 1 1 Input the file name gt gt dnpower bin When you choose 2 the following screen is displayed asking you to input the url pointed to the firmware file To make it work you must have a web server installed and copy the firmware file to the web server Input the URL Example http 192 168 1 1 dnpower bin gt gt http 192 168 1 1 dnpower bin Restore Default Configuration Data To reset the configuration data enter r at the main menu When the next menu is displayed choose 1 to reset all values to their factory default settings or choose O to return to the previous menu without resetting the data NETpower SNMP agent adapter Configuration Restore default data 1 Yes Do it lt 0 gt Return to previous menu Enter Choice gt gt Xtreme Power Conversion Corporation Page 24 XVRT User s Manual Uninterruptible Power Supply Reboot SNMP Agent Adapter Enter b at the main menu to reboot the NETpower device All settings will not be saved When the next menu is displayed choose 1 to reboot the NETpower device or choose O to return to the previous
19. menu NETpower SNMP agent adapter Configuration Reboot 1 Yes Do it lt 0 gt Return to previous menu Enter Choice gt gt Save 8 Reboot To save configuration data and reboot enter s at the main menu When the next menu is displayed choose 1 to save configuration data and reboot the NETpower device or choose O to return to the previous menu NETpower SNMP agent adapter Configuration Save amp Exit 1 Yes Do it lt 0 gt Return to previous menu Enter Choice gt gt Exit Without Saving Enter x at the main menu to exit the Configuration Screen Xtreme Power Conversion Corporation Page 25
20. nversion Corporation Page 9 XVRT User s Manual Uninterruptible Power Supply Hardware Installation Guide Inspect the UPS upon receipt The packaging is recyclable keep it for reuse of dispose of properly Installation of Rack mount accessories Install the rack mount type units according to the following illustrations Vertical Tower Configuration Wall Mount Configuration Xtreme Power Conversion Corporation Page 10 XVRT User s Manual Uninterruptible Power Supply Connections and Startup Connect to Utility Power Plug the UPS into a 3 wire grounded receptacle of proper size per UPS specifications Make sure the receptacle is protected by the proper size fuse or circuit breaker and is not located on the same circuit with equipment requir ing higher amounts of power e g refrigerator air conditioner copier Avoid using an extension cord to connect the UPS to the input power receptacle NOTE Size of Branch Circuit Over current Protection CAUTION to reduce the risk of fire connect only to a circuit provided with 30 amperes maximum branch circuit over current protection in accordance with National Electric Code ANSI NFPA 70 Start the UPS Turn the UPS on by pushing the Power switch button on the front of the UPS The UPS will conduct a self test once connected to input power and the power switch turned ON DO NOT add or remove equipment from the output of the UPS while the UPS is conducting its self test Wait until the
21. ny open files before the battery is exhausted e To turn off the UPS Some computers are equipped with a special connector to link with the communication port In addition special cords may be required Some computers may require special UPS monitoring software Contact your dealer for the details on the various interface kits Xtreme Power Conversion Corporation Page 13 XVRT User s Manual Uninterruptible Power Supply Batteries The life of batteries used in these UPS products is estimated at 3 6 years depending on level of usage Once the battery is no longer useful and must be replaced please contact service personnel for assistance Replacing The Battery QUALIFIED SERVICE PERSONNEL ONLY CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the bat tery under the supervision of Qualified Service Personnel knowledgeable of batteries and their precautions CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present risk of electrical shock Do not dispose of batteries in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION Although the battery system voltage is only 12VDC and 24VDC the battery can present a high risk of short circuit current and electrical sho
22. omer has requested and received a Return Material Authorization RMA number DOA equipment is defined as equipment that does not properly function according to user documenta tion when initially received and connected in conjunction with proper procedures as shown in the user documen tation or via support provided by XPC Corporation personnel or authorized agents This warranty shall be void if a the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifi cations or c the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions Any technical advice furnished by XPC Corporation or a XPC Corpora tion authorized representative before or after delivery with regard to the use or application of Xtreme Power Con version equipment is furnished on the basis that it represents XPC Corporations best judgment under the situation and circumstances but it is used at the recipient s sole risk EXCEPT AS STATED ABOVE XPC Corporation DISCLAIMS ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EXCEPT AS STATED ABOVE IN NO EVENT WILL XPC Corporation BE LIABLE FOR DIRECT INDI
23. on Help in UPSMON toolbar for further software configuration Connect the optional external SNMP card if purchased See Appendix A for configuration details Connect the Loads Plug your equipment e g computer monitor critical data storage device etc into the Battery Power supplied outlets Plug your peripheral equipment e g printer scanner fax audio device to the Bypass outlet s Do not plug a laser printer into the UPS output outlets as its power demand is much higher than typical peripherals and may cause the circuit breaker to trip It is suggested that laser printers and other heavy loads be connected to the Bypass outlets Xtreme Power Conversion Corporation Page 11 XVRT User s Manual Uninterruptible Power Supply Connect Telephone or Data Device If you wish to protect a fax modem or other telephone or data networking device plug the cable from the wall into the IN jack Connect the cable provided with the UPS from the OUT jack to the fax modem or other net working device To protect a 10Base T UTP network interface obtain and use a UTP cable to connect the OUT jack to your computer Test It is recommended that the user perform a simulation test when using the UPS for the first time or when adding an additional piece of equipment to verify actual load levels Conduct a simulation test 1 Switch the UPS ON 2 Wait for the Power Indicator to light up 3 Unplug the UPS to simulate a utility failure
24. ower SNMP agent adapter Configuration SNMP Access Control Setup Menu Community name IP address Access 1 2 3 4 1 Set Access Control 1 2 Set Access Control 2 3 Set Access Control 3 4 Set Access Control 4 lt 0 gt Return to previous menu Enter Choice gt gt SNMP Trap Receivers Enter a 4 at the main menu the following screen will be displayed allowing you to setup the SNMP Trap Receiv ers The Severity includes Any Server Warning and Informational The Any means any event will be sent to the trap receiver The Severe means only severe events will be sent to the trap receiver The Warning means only warning events will be sent to the trap receiver The Informational means only informational events will be sent to the trap receiver The Generation item is used to enable or disable trap generation NETpower SNMP agent adapter Configuration SNMP Trap Receiver Setup Menu IP address Community Severity Generation 1 2 192 168 1 2 public any disable 3 4 1 Set trap receiver 1 2 Set trap receiver 2 3 Set trap receiver 3 4 Set trap receiver 4 lt 0 gt Return to previous menu Enter Choice gt gt UPS Properties Enter a 5 at the main menu the following screen will be displayed allowing you to setup the UPS Properties including UPS Identification Name UPS Attached Device and Last Battery Replacement Date NETpower SNMP agent adapter Configuration UPS Properties Setup UPS Identification Name
25. s essential that only the supplied power cord be used Use only shielded cables to connect I O devices to this equipment WARNING Any changes or modifications not expressly approved by the manufacturer of this device could void the user s authority to operate the equipment IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow ALL instructions carefully during the installation and operation of the UPS and Batteries Read this manual thoroughly before attempting to unpack install or operate This UPS is intended for Installation in a Controlled Environment CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the UPS cover Qualified Service Personnel must Xtreme Power Conversion Corporation Page 3 XVRT User s Manual Uninterruptible Power Supply perform ALL repairs and maintenance No user serviceable parts inside CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is discon nected CAUTION UPS must be connected to an AC power outlet with fuse or circuit breaker protection Do not plug into an AC wall outlet that is not grounded If you need to de energize this equipment turn o
26. sessesssseossssssossssscsseseosessscsssosecssosecsesssesssossossosseseosesse 18 Xtreme Power Conversion Limited WarraNty sssssssssssrscrsrrssrssorersssrrt 19 Appendix A SNMP Configuration Guide scccsssccsssccssscccssseccsssccssseees 20 Xtreme Power Conversion Corporation Page 2 XVRT User s Manual Uninterruptible Power Supply Introduction Thank you for selecting this Uninterruptible Power Supply UPS It provides you with protection for connected equipment Please read this manual before installing the XVRT Series UPS models XVRT 1000 XVRT 1500 XVRT 2200 and XVRT 3000 as it provides important information that should be followed during installation and main tenance of the UPS and batteries allowing you to correctly set up your system for the maximum safety and per formance Included is information on customer support and service if it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so that the Technical Support personnel can more effectively assist you Safety Instructions ATTENTION To safely interact with and enjoy all the features and benefits of these Xtreme Power Conversion Un interruptible Power Supplies UPS please read and follow all installation and operation instructions completely These UPS are designed to provide power protection for connected electron
27. the outside of all packages Xtreme Power cannot accept any package without the RMA number marked on the outside of the boxes 4 Return the UPS by insured prepaid carrier to the address provided by the Technician 5 Refer to the Warranty statements in this manual for additional details on what is covered Xtreme Power Conversion Corporation Page 18 XVRT User s Manual Uninterruptible Power Supply Xtreme Power Conversion Limited Warranty Xtreme Power Conversion XPC Corporation warrants Xtreme Power Conversion equipment when properly ap plied and operated within specified conditions against faulty materials or workmanship excluding batteries for a period of three years for XVRT Series products from the date of purchase XPC Corporation warrants internal batteries for a period of one year from the date of purchase For equipment sites within the United States and Canada this warranty covers repair or replacement at the sole discretion of XPC Corporation The customer is re sponsible for the costs of shipping the defective product to XPC Corporation XPC Corporation will pay for ground shipment of the repaired or replacement product This warranty applies only to the original purchaser If equipment provided by XPC Corporation is found to be Dead on Arrival DOA XPC Corporation will be respon sible for the costs of shipping product to and returning equipment from the customer in a timely manner as agreed to with the customer once the cust
28. the serial port is not used by any program on your PC 6 Run a terminal program such as HyperTerminal 7 Configure the serial port for 9600 bps no parity 8 data bits 1 stop bit and no flow control 8 Reboot the Net Logic Card 9 Press ESC key right after reboot The Card Box will detect if the user presses a ESC key for 5 seconds If so it will allow the user to log in otherwise it will try to initialize the external MODEM for other usages So you have to press the ESC key as quickly as possible You may keep holding the ESC without releasing it right after the system is started to make sure it will not be too late or missing 10 10 Use dnpower for the User Name and for the Password 11 11 A Configuration Screen is displayed Note The default login user name and password are both dnpower Configuration Screen When you enter into the Configuration Screen the following menu is displayed Xtreme Power Conversion Corporation Page 20 XVRT User s Manual Uninterruptible Power Supply NETpower SNMP agent adapter Configuration HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH lt Main Menu gt HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH 1 SNMP Agent IP Parameter 2 MIB II System Group 3 SNMP read write Access Control 4 SNMP Trap Receivers 5 UPS Properties 6 System Time amp Time Server 7 User Account 8 E mail Setting 9 Environmental Monitoring Module w Web and Telnet Service Setting u Upgrade firmware r Restore Default Configurat
29. tion with Telnet or Terminal is completed To make changes to this setting 1 Log into the web browser by typing the IP address in the browser s address bar 2 Enter the username and password of dnpower for both fields 3 Go to the configuration tab and select Event actions 4 Highlight Power Failure and hit select 5 Scroll down to Power Failure Shutdown and uncheck Enable This disables the feature 6 Leaving Enable checked and changing the delay time will shutdown the UPS when a power failure occurs after the specified delay time is reached Using Telnet 1 Make sure the Net Logic Card is plugged in the UPS properly 2 Connect a network cable to the LAN connector on the Net Logic Card 3 Telnet to the Net Logic Card from the PC via the path described below Start run telnet 192 168 1 254 4 Use dnpower for the User Name and for the Password 5 A Configuration Screen is displayed Note The default IP address of the Card is 192 168 1 254 The default login user name and password are both dnpower Using Terminal 1 BEN O 00 On a Make sure the Net Logic Card is plugged in the UPS properly Connect the modem cable to the MODEM connector on the Net Logic Card Connect a null modem cable to the end of the model cable Connect the other end of the null modem cable to a serial port on your computer NETpower lt MODEM cable gt lt null modem cable gt Computer running Terminal program 5 Make sure
30. to verify loads via software 4 Return utility power When utility failure occurs the UPS output outlets will supply power to your equipment from its battery and the alarm will beep every 5 seconds Be sure that your equipment is running under the limited rating power The XVRT measures the Volt AMP VA rating of the load while on Utility and the Watt VV rating of the load when on bat tery Therefore monitoring the load levels via the software while on battery will determine the actual load on the system during a power outage Ensure the UPS is not loaded to more than 80 while on battery Restore the utility by plugging the UPS back into the existing power source Repeat this test when adding additional loads to make sure the UPS works properly Other Features Overload Protection If an Overload situation is detected during the self test the UPS audible alarm will activate emit a long beep and automatically shut down the system Unplug at least one piece of equipment from the Battery Supplied outlets Switch the UPS OFF wait 5 seconds check to make sure the circuit breaker is reset and the switch the UPS ON Self Protection Failure The UPS is equipped with a self protection feature to prevent damage to the UPS Once the UPS is switched OFF the user must wait 5 seconds before switching the UPS ON again Power Failure When a Power Failure occurs after turning on the UPS and prior to the self test sequence the UPS will automati ca
31. wer Xtreme Power Conversion Corporation Page 15 XVRT User s Manual Uninterruptible Power Supply Specifications MODEL NUMBER XVRT 1000 XVRT 1500 XVRT 2200 XVRT 3000 INPUT Capacity 1000VA 600W 1500VA 900W 2200VA 1320W 3000VA 1800W Voltage 120VAC Frequency 50 60Hz auto sensing OUTPUT Voltage 120VAC Frequency 50 60Hz 0 5 Transfer time 2 4 ms typical Voltage regulation AVR AVR automatically increases output voltage 15 above input voltage if 9 to 25 of nominal AVR decreases output voltage 13 below input voltage if 9 to 25 of nominal PROTECTION amp Spike protection 320 joules FILTERING EMI RFI filter 10dBA at 0 15MHz 50dBA at 30MHz Overload capacity Shutdown if overload exceeds 110 of nominal at 60 sec and 130 at 3 sec 10base T cable port Network UTP RJ45 compatible jacks BATTERY Battery type Sealed maintenance free lead acid a quantity and 3 6V 8AH 2 12V 9AH 4 12V 9AH Recharge 8 hours to 90 of full capacity Protection Automatic self test and discharge protection replace battery indicator Backup time 3 180 min depending on load PHYSICAL Dimensions WxDxH 15 0x 14 3 x 1 7 in 16 9 x 14 0 x 3 3 in 16 9 x 13 8 x 5 1 in 16 9 x 19 1 x 5 1 in 1U 2U 3U 3U Shipping dimensions 18 8 x 17 2 x 6 3 in 23 0x21 0x8 7in 22 4x20 5x11 2in 26 1 x 23 0 x 11 2 in UPS weight 25 3 Ibs 35 9 lbs 62 6 lbs 71 9 lbs Shipping weight 28 6 lbs 42 5 Ibs 68 5 Ibs 79 4 lbs Line cord 6ft 5 15P 6ft L5 30P Re

Download Pdf Manuals

image

Related Search

Related Contents

Manual - Engineering Electronics Shop  Trentadue - OT Bioelettronica  Whitehaus Collection WH1-114L-WH Installation Guide  FR1-F MODE D`EMPLOI  INTERRUPTOR HORÁRIO (TIMER) MODELO TE-940  Samsung TV Monitor 23" mit überlegenen eingebauten Lautsprechern Benutzerhandbuch  BEDIENUNGSANLEITUNG INSTRUCTION MANUAL MODE D    Sharp MX-M283 Government Compliance  Xerox Guia do usuário  