Home
Adroit SCADA with AmpCom Application Note
Contents
1. User Login v Delete CO Automatically login with these settings next time P ORS Type in the Windows s username with administrative right and password a username with password is required If you don t have one set one up under Control Panel gt User Accounts then click Finish You will now be logged on to the design environment 6 Page 3 2 Creating New Project and New Graphic Form a Under the tab Enterprise Manager right click on Projects and select Add a Project to create a new project named AmpCom Demo as shown below Enterprise Manager 3 Servers E Mi WIN VKFOV4SIRMG WIN VK Se Datasources EG Adroit i rO Management E E Profile H ig Security F Projects ni AmpCom Demo oy Translation H Shapes Wizards and H 3 System Information b Next right click on AmpCom Demo that is just created and select Create Graphic Form then rename it as Main 7 Page 3 3 Creating and Scanning Tag to Display Value a Hover over and right click on Adroit under Datasources then select Open Configurator The Agent Configuration window will open 1 Servers A WIN VKFOV4SIRMG WIN VK oeae F Datagources E Agent Configuration AS TTT a OTT LILLTITTTTTTTTTTTT T Sr File View Options Agent mm cg Profile ah Security aa D DRTE
2. Setting Up Adroit to work with AmpCom over Modbus Ethernet TCP Application Note J G Adroit Technologies ampcom Table of Contents Creatine Projectand Setting Up of DiI OK erans EA 2 1 1 Setting up of Agent Server ccccsssccscsssscsccusreccousescueussscnecusressouesscucussscnsoussestonsssencusscneousresseness 2 Le SOCEM UDO DINE e E E 3 2 Starting Agent Server and Smart Ul Service Manager ssssssessssresesreresrrrsssreresrreresreresrrerssrereserersseeree 5 2A tartine ALENE SEVE reroror aE 5 2 2 Starting Smart Ul Service Manager ccccssccssccsseccseccscccseccseccseccseccaeecseetaeeteeeseeseesseeesessseusseseees 5 FATO Man UDE SIENE en a ete me Renner ee ne ane ee ee en ee eee ee eee 6 3 1 Login Onto Adroit SMart Ul DESIGN OP scccavevesssacaccon scnvsrasicucedsecosseansacaventugresuenianutheowsrasanaseatsbarreees 6 3 2 Creating New Project and New Graphic FOrm ccccccsseccccessecccesececeesececeeecceseesecessueeceseeneceesees 7 3 3 Creating and Scanning Tag to Display Value cccccccsseccccesseccceesececeeececeeeeceeeeeeeeseeaeceeseneceesens 8 3 4 Cheatinie Label to Display Value scccasdsncscocmnseseontaceedtetevsuucniseedanounuaunengesetnt in esaeuiiermoeeaeateceeaes 10 3 5 Creating and Scanning Tag to Write Value ccceecccccsssccecesececeeeceeeeeecceesesecesseneceesuaeceesenseees 12 3 6 Creating Button to WITS Value cscs tninionsssanenadtascnagiccticeeetcvdeas wet s
3. Drivers r Config Port Selection Local Details Retry 2 o Enable Secondary Cancel ance Modbus Ethemet Dri Primary Timeout ms 500 C P Fil BE Be 5 econi j y Ton E e eS m PLC Details PLC Station ID m Dynamic IP via DNS Lookup PLC Type Arm or Enable eee TCP IP aLe a o DNS Server IP PETET PLC Port o2 re Host Name b Hover the mouse over and right click on Modbus Ethernet Driver then select Add Device If Modbus Ethernet Driver is not on the list click Install under Protocol Driver to install the driver the Adroit 7 installation disc is required c Type in AMPCOM as the name of the device d Referring to above snapshot select Custom for the PLC Type type in the IP address of the AmpCom device for the TCP IP Address leave PLC Station ID and PLC Port as 1 and 502 respectively e Click Ping Test to verify if connection is successful f After successfully pinging the device click Advanced 3 Page Please read the driver documentation before modifying any of these settings OK Cancel Help Default values are shown in brackets Advanced settings r Backoff Connection Network latency between stations required on o rr Create seperate paralleled connections for devices with the same as a gateways only mSec O off IP and port optimised for RS232 gateways default
4. for Address Refer to the AmpCom User Manual for all the available WRITE Registers 0 for Scan rate ms then click on Scan Under currently scanned tags START will appear to have been scanned Now double click on the START value A window Edit Marshal Agent START will come up on the screen as shown on the following page 13 Page Edit Marshal Agent START pt a ee eet ne te ColdStar M l Cancel digt 0 eS a a l a Update All m E Te Em a E PN Update Curent B fide OFF FR rR e a goo S B fide OFF FR rR ON goo Header e iT Z cn 7 7a 7 Ci a m7 4 7a 7 7 7 ca Cc 4 lw Value Integer E Rawyalue Integer E Reverse Mapping Swap Bytes I Along the digiOO row Check the boxes for Pulse and ColdStart then make sure ColdStart value is set to Off m Set Delay to 300 as shown above n Click OK to close the active window o Click OK again to close the current window and then close the window on Agent Configuration p Click the Enterprise Manager tab right click on Adroit under the Datasources folder and select Refresh 3 6 Creating Button to Write Value a Double click on Main graphic form that was created earlier The graphic form will open and will become active Enterprise Manager Se Servers Si WIN VKFOV4SIRMG WIN Datasources GH
5. off efault Backoff period mSec O off default 20000 20000 Close Port after every transaction to the slave default off Backoff count only backoff after this number of 2 a Close and re connect to the slave on all communication consecutive failures default 2 errors off only close when retires exhausted default off Byte Ordering Custom Ple Type PDU lengths Reverse Modbus coil MSB LSB ordering when scanning i N them into integers default off Coils 00000 Bits f 384 I Force 16Bit boundary justification Default on Inputs 10000 Bits fi 984 Reverse MSb LSb ordering when scanning Holding register pa bits into Booleans default off Analogue 30000 Words 124 124 23 F Swap byte order on String agents default on Holding 40000 Words wap word s byte order default on Extended 60000 Words fi F Swap LONG word ordering default on Note To use these custom pdu sizes CUSTOM model must be selected in the config dialoque wap floating point word ordering default off General iv Use sequence numbering in the M BUS header on greater integrity P Use Modbus serial encapsulated in TCP IP default off during timeouts default on Optimize scanning of coils and relays to only scan the exact number of elements default off Use Function6 write Single Holding Register default off l Detailed Debbugging information default off Enable Unsol
6. up as shown below Data Element Selection A Pi Preview QQQ 100 Configuration Display Value Behavior Eoy Digital a EventLogging e EventOutput aan amp Expression Input Data Element String Formatting ul Coon eo f Type in Voltage L1 N 0 F27 for String Formatting g Click on the browse button l h the window on Configuration Input Value Data Element Browser will open 11 Page h Under Datasources gt Adroit gt Agentgroup expand Real and select VL1 N and then click Finish i Click Finish again to exit from the active window j Along the toolbar at the top of the graphic form click Preview k The label will now display the value of the device AMPCOWM at address 300081 as shown below Start Page AAA od BH G1 Design Xml Behind HH GQ 100 sb Click on the Design to go back into designing phase 3 5 Creating and Scanning Tag to Write Value a Hover over and right click on Adroit under Datasources then select Open Configurator The Agent Configuration window will open Adroit NHP 1C902AQE02A AS NHP 1C902A0E BX File View Options Security Window Help a Eg E Agent Configuration AS Agent Name START Description start Agent filter se IW Basic Advanced Systern Type Group Header Marshal Groups Use
7. Adroit Sm el Management i yf Profile H ah Security E E System E Projects cg i Wizards and H EE System Information 14 Page b Click the Toolbox tab and browse to Windows Forms and then click on Button c Move the cursor across to the graphic form and draw a box to create a button Toolbox h x Starck Page sml Behind button d On the button click on the tiny play button to bring up the Button Tasks window and then click on the dropdown box and select Operator Action Button Tasks Behaviors New Behavior B LI Color Display Value Execute Command e The window on Configuration Operator Action Behavior will pop up as on the following page 15 Page KS Configuration Value Data Element Browser Data Element Selection start A gt dig00 coldstartEnable i me dig00 delay dig00 description m dig00 initvalue j dig00 invert E Xml Behind pb Preview Q Q 9 Configuration Operator Action Behavior Select the data ele Data Element Adroit Marshal START dig00 rawvalue a digdO rawalue 7 os wm dig00 state0 Minimum Data Element Value 0 Maximum Data Element value 1 3 digo0 textvalue j dig00 time me dig00 value Control Action O Data Entry Data Set fo dig01 coldstartEnable mm dig01 delay be dig01 Jdescri
8. Currently scanned tags VL1 N will appear to have been scanned Click OK to close the current window and then close the window on Agent Configuration Click the Enterprise Manager tab right click on Adroit under the Datasources folder and select Refresh E Project Explorer Open Configurator Create Tag Include Header Slots Save Connection Details Edit Datasource Security Export Datasource Lock Copy Path 9 Page 3 4 Creating Label to Display Value a Double click on Main graphic form that was created earlier The graphic form will open and will become active Enterprise Manager aSa Servers E S WIN VKFOV4SIRMG WIN CD Datasources GH Adroit 5 Management ERED Profile H ak Security ERSE System w 3 Shapes Wizards and H S System Information b Click the Toolbox tab and browse to Windows Forms and then click on Label c Move the cursor across to the graphic form and draw a box to create a label Toolbox Start Page SA SEAD EREE 34 Windo 10 Page d On the label click on the tiny play button to bring up the Label Tasks window and then click on the dropdown box and select Display Value Q Jebedubecubedebedabocubecuban oO Jubdebedubedubecube label E E Operator Action Size Tooltip Visibility e The window on Configuration Display Value Behaviour will pop
9. System Description fYL1 N Real agent 2 Projects a a AmpCom Demo Agent filter ty Translation i E Main M Basic Advanced Emory PM Project Type Group ES Shapes Wizards and Real Emory System Information Toolbox Enterprise Manager b Under Agent filter gt Type click the dropdown box and select REAL c Under Agent gt Name type in VL1 N then click Add d An agent named VL1 N is then added to the box near the bottom of the window Security Window Help e Now click on Scan A window on Tag scanning configuration will open as shown on the following page 8 Page E Adroit WIN VKFOV4SIRMG AS WIN VKFOV4SIRM EIS Davi TD CE stated C Stopped Agent Help VLT N in Find pe Slot l Header slots Details value Import fares rea ptet F Scan input inhibited F Output enabled q Scan tate ms Deadband Currently scanned tags Unscan Tag Address Rae DeadBand 0 L1 N value 300081 F Under Device click the dropdown box and select AMPCOM that was previously created Click OK if prompted to Create it automatically Next click the radio button next to Started Adroit will now start to scan the device Type in 300083 F for Address Refer to the AmpCom User Manual for all the available READ Registers 400 for Scan rate ms then click on Scan Under
10. d by Scan Alarm D E Remove Help 4 12 Page Under Agent filter gt Type click the dropdown box and select Marshal Under Agent gt Name type in START then click Add An agent named START is then added to the box near the bottom of the window Now click on Scan A window on Tag scanning configuration will open as shown on below E Tag scanning configuration AMPCOM Device SMPCOM f Started C Stopped Agent START in Find Slot Header slots Details Address e Scan rate mz Deadband i Scan input inhibited i Output enabled Curenth scanned tags scan Unecan ILT value 300097 F 400 0 IL value 3000949 F 400 0 ILS value 300101 F 400 0 IMB value 300151 F 400 0 LITHO value 300165 F 400 0 LTH value 300167 F 400 0 L3THO value 300169 F 400 0 PT 100 1 value 300787 400 0 PT 100 2 value 300786 400 0 REMOTE value 412501 0 0 RESET value 412004 0 0 START value 412502 0 0 STOP value 412503 0 0 TCU value 300171 F 400 0 i Ok Help Import we rier Aa ES Under Device click the dropdown box and select AMPCOM that was previously created Click OK if prompted to Create it automatically Next click the radio button next to Started Adroit will now start to scan the device Check the Scan Inhibited and Output enabled boxes Type in 412802
11. icited Support default off l Use IEC Standard Addressing default off IEC Addressing with Offset default off V Address 255 Padding Required default on g Check both the boxes for Swap word s byte order and Swap floating point word ordering the click OK to close the active window h Click OK to close the AMPCOM window then click OK again to close the Adroit Configuration Setup window 4 Page 2 Starting Agent Server and Smart UI Service Manager 2 1 Starting Agent Server a Goto Start Menu click on All Programs gt Adroit 7 gt Adroit Agent Server if you do not have a license dongle click on Adroit Agent Server time license Adroit Agent Server window will now start a shortcut of Adroit Agent Server could also be found on the desktop 2 2 Starting Smart UI Service Manager a Now goto Start Menu click on All Programs gt Adroit 7 gt Adroit Smart UI Service Manager Make sure the SmartUl Service is Running by clicking the icon on the taskbar SmartUl Service is required when using Smart UI Designer SmartUI Service Manager Licence Information SmartUl Service Running SMART UI 5 Page 3 Adroit Smart UI Designer 3 1 Login on to Adroit Smart UI Designer a Goto Start Menu click on All Programs gt Adroit 7 gt Adroit Smart UI Designer A window b will open as shown below
12. ionaibecebatacedistsibbdasthrancabasiodbeatnndedaaiios 14 1 Page 1 Creating Project and Setting Up of Driver 1 1 Setting up of Agent Server a Go to Start Menu click on All Programs gt Adroit 7 gt Adroit Setup Adroit Configuration Setup window will open b Under the Agent Server tab type in the following Project Name AmpCom Agent Server Name AS Sms Ss lookin war SC EB Agent Server Ul Connection UI Preferences Drivers Eventlog Service ao oen Date modified tiie _ ampcom wgp 9 27 2012 12 03 PM WGP File hn Select Configuration AmpCom gt _ batching wgp 9 27 2012 11 59 AM WGP File Agent Server Type Stand alone Distributed server gt Distributed server Options Project Name Geccany om F Agent Server Nes SS Auto Load Filename C Project WGP ampcom wgp C Time Granularty fi a Seconds Os Save As Remove Advanced About ANDR femocom wan Files of type Auto Load files wgp 7 Exclude path from file name c Click the browse button Lil along the Auto Load Filename row the window for Select Auto Load File will open d Name the file ampcom and click open e Click on Save As and Type in AmpCom as the Configuration Name 2 Page BB Adroi Agent_Server_Configuratic Batching Auto Load Filename 1 Time Granularity 1 2 Setting Up of Driver a Now click on the tab
13. ption m dig01 initYalue dig01 invert m dig01 name z dig01 pulse f dig01JrawYalue we dig01 state0 mm dig01 state1 i dig01 Jtext alue wm dig01 time Advanced View gt lt lt Previous Next gt gt oe fe dig01 value v Action Type Control Action Toggle Boolean Increment Decrement by g SS _ g dig02 coldstartEnable oe m Fein lela Adroit Marshal START dig00 rawy alue f Click on the browse button l h the window on Configuration Input Value Data Element Browser will open g Under Datasources gt Adroit gt Agentgroup expand Marshal and then Expand START and then select digi0OJrawValue and then click Finish h Select Control Action as the Action Type i Click on the dropdown box for Control Action and select Toggle Boolean j Set Minimum Data Element Value to 0 Maximum Data Element Value to 1 k Click Finish again to exit from the active window I Click the Save Button on the Smart UI Designer to save the graphic form m Along the toolbar at the top of the graphic form click Preview n Press the Start button and ensure Virtual Input 1 is active Note this button has been set up as a pulse and will not latch once pressed 16 Page