Home
Dear Customer: Thank you for purchasing our
Contents
1. administrator privilege through the management software of the access control 4 gt When conducting administrator verification Illegal Operation will be prompted if registered information of ordinary users is input the main menu cannot be entered to conduct setting operation 5 gt When inputting an ID number or a password you can omit the front zeros of the numbers and directly input the rear numbers For example If your ID is 00050 just input 50 6 gt When the registration is completed verify your fingerprints to test the effectiveness of your fingerprint registration The testing method In standby mode press your registered fingerprints If the identification is successful it means that your fingerprints are clear and the registration quality is good If the identification is difficult to pass it means that the quality of your registered fingerprint is not good enough or your registered fingerprint is not clear new registration or registration with another finger are needed 3 1 1 Delete Registered Data When an employee is resigned or the registration is error the existing ziS Fingerprint Access control User s Manual registration number should be deleted Enter Menu Data Management Delete Registered Data enter the data delete state as shown in Fig 16 input the registered number to be deleted for example 00001 press OK to confirm as shown in Fig 17 press OK key again
2. is selected in the Enable User Time Section this time section will be effective otherwise the time section of the time group will be effective Note After it is enabled the user still is controlled by the Multi user function of the user s time group If the user time section is enabled it is recommended that the time group of multi user is not enabled 5 gt Enable user identification mode It is a switch setting It controls whether the user s own identification mode is enabled or the identification mode of the time group is used 6 gt Identification mode It is the user s own identification mode If Yes is selected in the Enable User Identification Mode this identification mode is effective otherwise this mode is not enabled 7 gt Enable user valid period User valid period must be set by the supporting software If It is set as No this function is disabled If it is set as Yes this function is enabled 3 1 5 Attendance Access Control Operation After user registration and access control settings are completed the access control can be put into use 1 Access control identification operation According to parameter settings of identification mode of the access control 7 identification modes can be used Fingerprint Password Card Card Fingerprint Card Password Fingerprint Password and Card Fingerprint Password 1 Fingerprint identification Fingerprint identification can be done
3. If a administrator has been registered it cannot be entered without administrators verification Press MENU key wait until the interface displays Administrator Identification then perform identification The identification method is the same as that for user identification If the administrator identification failed incorrect fingerprint password or inductive card Illegal Operation will be displayed and audible indication will be given out The administrator identification must be re conducted If the identification succeeds the management menu interface can be entered 4 2 Data Management The Data Management menu includes user registration administrator registration delete all data delete all records and safety level setting OA a Fingerprint Access control User s Manual User registration please refer to Section 3 1 2 Administrator registration Under the data management interface as shown in Fig 4 select Administrator registration press OK key to enter the selection interface of administrator right as shown in Fig 24 The registration method is the same as that of user registration Gen Manager AllLog Delete Delete Yes OK No ESC Fig 24 Fig 25 Delete all data Please refer to Section 3 13 Delete all records Enter Menu Data management Delete all records press OK key all records will be deleted as shown in Fig 25 Note All records deleted from the above menu can
4. and down arrows to or select the display order of the Month Day Year date of the access control The factory default iS Year Month Date Voice prompt Yes or No If you select Yes you will hear voice prompt when 26 Fingerprint Access control User s Manual conducting identification If you select No you will not hear voice prompt when conducting identification If the identification succeeds the buzzer will sound Click Click Click three times If the identification fails the buzzer will sound Click one time only The factory default is Yes Sensitivity If this item is selected the adjusting access control will adjust the inductor to the best state Restore to After this item is selected all factory setting data on the equipment will be cleared and all settings will be restored to factory default value Please be careful when using this function Communication setting communication settings includes 7 items such as machine number baud ratio port number communication password IP address subnet mask and default gateway The detail description is as follows 1 gt Machine number Setting Description value 1 255 Set the number of the access control Factory setting Note Machine number is the unique ID for the machine If access controls with the same machine number are used in the same network not only can they not work properly but also the acces
5. are corresponding sub items level 3 menus under the level 2 menu The structure is shown in the following figure os ee Fingerprint Access control User s Manual Level 1 menu Level 2 menu Level 3 menu Note Only the super administrator is entitled to enter the following items under the level 2 menus system setting communication setting and record setting 2 2 13 Access Control Setting Menus In the level 1 menu when the cursor is at Access Control Management click OK to enter the level 2 menu This menu has 9 setting items The structure is shown in the following figure Level 2 menu Level 1 menu Note Only the super administrator is authorized to enter the level 2 menu under sfa Fingerprint Access control User s Manual Access Control Management 2 2 14 System Information Menu Level 1 menu Level 2 menu In the level 1 menu when the cursor is at System Information click OK to enter the level 2 menu This menu has 7 items The menu structure is shown in the above figure Chapter Three Operation Flow 3 1 Initial Use The initial using steps are as follows Detail operation steps are as follows 3 1 1 Hardware Installation For the detail installation steps and methods please refer to Section 1 3 3 1 2 User Registration The fingerprint access control has three registration identification methods fingerpri
6. control and time and attendance management It provides safe access control function as well as convenient time attendance management A fingerprint access control management system consists of a fingerprint access control terminal hereinafter called access control electronic lock controller electronic lock door sensor alarm bugle button door bell power PC and access control management software The access control is responsible for user s information registration and daily identification of entry in and out When used as access control it allows the user to open the door by pressing the registration finger without using a key When used for both access control and time attendance it allows that only registered fingerprints are required for these purposes The access control system is designed to configure parameters back up data of the equipment and download access record It also conducts data statistics and processing according to the time and attendance rules set forth by the administrator generates various statistical reports and enquires in and out record logs As a result it can fulfill the functions of access control and time attendance The access control can operate in off line mode without being connected with the management software For an access control used without the management software functions of user validation period and real time monitoring are not available There are mainly two communication modes betwee
7. out If identification records are full read attendance records in the terminal will be overwritten Factory setting 4 4 Access Control Setting It is used to set user rights Press MENU Access control setting to enter its menu The menu include 9 settings opening delay opening overtime alarm illegal opening alarm time section setting time group setting user control setting threatened alarm threatened action and Wigand mode The interface display is shown in Fig 18 and Fig 19 For Time Section Setting Time Group Setting and User Control Setting please refer to Section 3 1 4 For opening delay opening overtime alarm illegal opening alarm threatened alarm threatened action and Wigand mode the detail descriptions are as follows 1 gt Opening delay Setting Description items No 255 setting the length for opening door the unit is second 30E Fingerprint Access control User s Manual Factory setting Note If it is set as 0 the door will be opened for a long period and will not close automatically after it is opened 2 gt Opening overtime alarm Setting Description items No 3600 Set the overtime period for giving an alarm after the door is opened The unit is second When it is set as No the alarm function will not be started No Factory setting 3 gt Illegal opening alarm Setting Description items No 255 After the value i
8. password card 1 Registering fingerprint Fingerprint can be registered by two methods A After connecting to the access control all registration can be done through the access control no any operation is needed on the MF 10 All fingerprint data that are registered successfully on the access control will be automatically transmitted to the MF 10 B After connecting to the management software in the computer fingerprint can be registered and fingerprint data can be managed through the software Note Each MF 10 can store 2000 fingerprints 2 Registering password and inductive card 36 Fingerprint Access control User s Manual Passwords and inductive cards can be registered by one method i e they are connected to the access control and are registered through the access control The registered data will be automatically transmitted to the MF 10 no any operation is needed on the MF 10 Note The MF 10 does not have the function of registration of password and inductive card When it is connected to the access control data of password and inductive card in the access control can be transmitted to the MF 10 Therefore the MF 10 does not save data of password and inductive card Registration information in the MF 10 can be read only by the management software 3 Identification operation Identification in the MF 10 can be operated by fingerprint password or inductive card The MF 10 supports single identification mode only Even
9. to enter the interface for deleting press OK key directly to confirm and deletion will be done OOOO 00001 0 Fig 16 Fig 17 Note The last 0 of 0001 0 represents the first fingerprint similarly 1 and 2 represents the second and third fingerprint respectively If it is P it means that the password data will be deleted If it is C it means that the data of the inductive card will be deleted Press up and down keys to select 3 1 2 Settings Relating to Access Control After the user registration is successful the user type should be selected through the User Control Setting menu If Attendance is selected the user can do the attendance only is not controlled by the privilege of the access control and does not have the right to open the door and only the single identification mode can be used If Access Control is selected the user is controlled by the privilege of the access control and have the right to open and close the door When using the access control function of the access control for the first time settings such as Time Section Time Group and User Control Setting must be set so that users can open and close the door normally In standby mode press MENU key select Access Control Setting enter the access control setting interface there are 9 setting items as shown in Fig 18 and Fig 19 19 Fingerprint Access control User s M
10. Dear Customer Thank you for purchasing our product MF850 Fingerprint access control To fully enjoy the benefits of this product please read instructions included in this manual carefully Version Ver 1 0 Jan 2010 All images in this manual are for reference and should be subject to the actual product Because there might be print errors inaccurate descriptions in this Manual and the Manual might be updated this manual will be subject to change In case any modifications of this manual occur the updated version will include these changes without any notice Guarantee on Human Rights and Privacy We hereby guarantee that fingerprint access controls supplied by our Company only acquire fingerprint minutiae and do not preserve fingerprint privacy In addition the fingerprint minutiae cannot be restored to the original fingerprint images Therefore your human rights will not be violated Under no circumstances shall we the provider of the equipment be liable to any direct or indirect consequences arising out of or in connection with our equipment In the event of any disputes with the user on human right copying or privacy Please communicate with your employer Fingerprint Access control User s Manual Table of Contents Table of Contents Chapter One Product Overview sl SS VSECTNIO VEL VIC Wc gatnn tata T ct detent edeneebunaenea 3 t2 Paramet rOin 4 to Hardware InstallaO mcs ecen N 6 L4 Appearance Descr
11. anual LegOpen OpenOver Ne PassTimeSet llegOpen No GroupTime PassTimeSet User setting GroupTime hreatAct User setting ThreatWarn ThreatAct Wath OK WA OK i amp 8 ESC 3 1 4 1 Time Section Setting a Fifty in and out time sections of the access control can be set at most In and out time from Monday to Sunday can be set for each time section Under the interface shown in Fig 18 select Time Section Setting press OK to enter the setting interface as shown in Fig 20 Press Up and Down keys to move the cursor to select the time section to be set press OK key to confirm Use Up and Down keys to select the date to be set press OK key to move the cursor to the number directly input numbers or press UP and Down keys to input the setting value press OK key to confirm finally press ESC key to exit and save it 0 00 23 59 i amp 8 ESC Fig 20 Fig 21 3 1 4 2 Time Group Setting Set the time group of the access control Users can be divided into different time groups Thirty time groups can be set at most Under the interface shown in Fig 18 select Time Group Setting press OK to enter the setting interface as shown in Fig 21 Press Up and Down keys to select the time group to be set press OK key to confirm and press OK key move the cursor to the setting item Multi user Time Group or Identification Mode and set each item After se
12. ata through communication between computer and TCP IP and RS485 For detail software management operation please refer to the MF 10 software manual The MF 10 appearance is shown in the following picture Keyboard Fingerprint sensor Doorbell button Sensing are 5 2 Instruction for Connection of Access Control and MF 10 MF 10 can be connected to our company s access control with 2 data lines connecting to COM A and COM B of interface 1 of the access control After they are connected fingerprint password and cards can be transmitted without any 35 Fingerprint Access control User s Manual back management software All operations including registration and deletion of fingerprint password and card can be done on the access control without any operation on the MF 10 Multi identification mode can be used on the access control only If the external MF 10 fingerprint reader is connected multi identification mode can not be used on the MF 10 only single identification mode can be used on the MF 10 After the access control is connected with the MF 10 ensure power them up at the same time or power up the MF 10 first otherwise seamless connection cannot be achieved The connection schematic is shown as the following figure Electric lock Door contact v Door switch Access control Computer Outside Inside 5 3 MF 10 Operating Instruction 1 Operation Flow 2 Registering Fingerprint
13. by two ways 1 N identification Press your fingerprint on the fingerprint sensor If the identification NO 00001 succeeds voice prompt Thank You will be Type DoorKey 3 given out as shown in Fig 23 1 1 identification Input your ID number on the keyboard press your fingerprint when the Fig 23 screen is displaying 1 1 Fingerprint Confirmation If the identification succeeds voice prompt Thank You will be given out If the identification fails voice prompt Please Re press Your Finger will be given out meanwhile the screen will display Please Re press Your Finger moe Fingerprint Access control User s Manual 2 Password identification In standby mode input your ID number press OK key input password 1 4 digits press OK to confirm If the identification succeeds voice prompt Thank You will be given out If the identification fails the access control will sound Click then the screen will display Please input again you should conduct the identification again 3 Inductive Card identification In standby mode put your inductive card close to the card slotting area of the access control When your card is close enough to the card slotting area the access control will conduct identification and give voice prompt Thank You If the identification fails or your card has not been registered the access control will sound Click an
14. communication cables are used the cables must be double core shielded wire Avoid using network cables Do not connect the equipment to strong power 220V The maximum communication distance is 1100m Additional repeaters must be provided for communication distance greater than 800m so as to ensure communication reliability For RS485 communications it is recommended that Baud Aba Fingerprint Access control User s Manual rate be set to 19 200 because the communication reliability and transmission distance increase when Baud rate reduces But the transmission speed falls when the Baud rate reduces 3 Wiring for the exit button should not be too long instead it should be close to the terminal as applicable 4 The controlled lock power should be close to the terminal and electronic lock as applicable 5 The relay can control the electronic lock directly and the maximum withstand current is DC 30V 2A 1 4 Appearance Description samplere Card induction areas Red Power indicator Green status indicatore Fingerprint Access control User s Manual TCP IP RS485 Interface 1 Interface 2 a he hl ef i Access control terminal 1 5 Interface Explanation 1 RJ45 communication interface 8P 2 54 definition 2 Access control interface 1 12P interface on the left of the back definition IN ion Doorbell interface 2 Doorbell interface 1 External signal input 2 External signal input 1 GND P
15. control is of mounting type The steps for installation are as follows 1 Positioning Position four holes on appropriate wall according to iron board s holes 2 Drilling Drill four holes using screws supplied with terminal 3 Fixing iron board Put an iron board on appropriate place of the drilling area And then fix the iron plate firmly by beating the screws 4 Suspension Hang up the terminal on the iron board with the bottom 1 4m from the ground 5 Powering on Connect the equipment as per the reference connection diagram and power on the equipment 6 Connecting to the computer The product may be connected to the computer using RS485 or TCP IP Select a communication mode for the access control and management computer Then set up communication parameters on the access control See Section 4 3 Connect the access control and computer with communication cables Then install the management software on the management computer and set related communication parameters which must be the same with the parameters on the access control For operating modes see the Users Manual for Reference Software Notices for Installation 1 Environment It is recommended that the access control be installed indoor If used outdoor the equipment must be protected against strong rays and rains It is also recommended a sunshade and heat dissipation device be used in summer and thermal insulation facilities be used in winter 2 If RS 485
16. d then the screen will display Please input again 4 Card Fingerprint In standby mode slot your card and press your fingerprint The registered number of your fingerprint must be the same as that of your card If the identification succeeds voice prompt Thank You will be given out 5 Card Password In standby mode slot your card and input your password The registered number of your password must be the same as that of your card If the identification succeeds voice prompt Thank You will be given out 6 Fingerprint password In standby mode press your fingerprint and then input the corresponding password If the identification succeeds voice prompt Thank You will be given out 7 Card Fingerprint Password In standby mode slot your card press your fingerprint and input your password If the identification succeeds voice prompt Thank You will be given out 2 The identification on the external reader is conducted as follows You can do attendance access control identification on the access control In addition you can do the identification on the MF 10 and external inductive card reader which are connected with the access control A MF 10 identification operation The MF 10 only supports 3 single identification ways such as Fingerprint Password and Inductive Card Even the access control is set with multi identification mode the multi identification mode will automatically change to the
17. he function is described as follows ESC To perform EXIT or CANCEL OK To confirm MENU To access menu management A or V Scroll up down button for menu operation 0 9 To input numbers F1 F4 Shortcut keys The definition is given in Section 4 6 _10 Fingerprint Access control User s Manual 2 2 Menu For the access control you can use function keys and numerical keys to perform flexible menu selection keyboard Level 1 menu input and various settings The oye A level 1 menu includes three categories record management setting and system information Each menu consists of different subordinate level 2 and level 3 menus to perform corresponding operations 221 Menu structure The constitutions of the level 1 menu are 1 Data management To register and delete the fingerprints passwords and data on inductive card for users or administrators and all records and to set safe value of algorithm 2 Setting To set system parameters for the terminal 3 Access control setting To set parameters for the terminal 4 System information To examine the information recorded in the terminal The structure of level 1 menu is shown in the figure above Only a super administrator is entitled to have access to Setting and Terminal Setting options in the level 1 menu An ordinary administrator is granted access to only a part of level 2 menu under Data management level 1 menu and System infor
18. iptioneeceienri 7 eS Anite era e EX DIAG a Oi aca de set ence ses sae dasesaansetatacetactbieeseaa nes 8 1 6 Fingerprint Placement Guide ccceeeeeeeeeeeees 9 Chapter Two Basic Function 2A Keyboard oeseri a a aries 10 Diet MO esntce selec aandce es aedeacueawaccee aedeecawacces aedes 11 2 21 Menu SIUC TUTE erse e EEREN 11 Chapter Three Operation Flow Sul Mial Ue 14 3 1 1 Hardware Installation ccccccccccceecceeceeeeeeeeeeeees 14 HE User Ree Braoa 14 JA te Delete Resistered Data say n sern Ee E ETR 18 3 1 2 Settings Relating to Access Control eeeeseseesseseeee 19 3 1 5 Attendance Access Control Operation eessse0s0000000 22 310 Record Searc hint eenean E 24 BZ DaN U Geesse ee saiac sateen ase 24 Chapter Four Management Operation 4 1 Enter Management Menu onenn oaa 24 Ad Data Manacement sisteem R 24 Bi aS E E TE E A 25 44 Access Control Settini ssns RS 30 AS SYEDA Oita a ediattoka ical elon 33 AO Shortcut Key SeN iseer EEan 33 Chapter Five MF 10 Description SL ProducCOVEIVICW siicdarsie sions a N 35 5 2 Instruction for Connection of Access Control and MF 10 35 Ey ee Fingerprint Access control User s Manual 5 3 MF 10 Operating Instruction Technical Support Appendix Fingerprint Access control User s Manual Chapter One Product Overview 1 1 System Overview A fingerprint Access control combines functions of access
19. istration will be rejected and The fingerprint is repeated will be displayed Finger x 00001 Continue Yes 0K No ESC Fig 10 Fingerprint Access control User s Manual Password registration Each user can register one group of password besides 3 fingerprints Under the interface shown in Fig 5 select Password Registration press OK key the display is shown in Fig 12 Password PWD ID New Enroll Yes OK No ESC Confirm Fig 12 Fig 13 Under the interface shown in Fig 12 press OK key to enter the input state for registering numbers After inputting numbers for example 00001 press OK key the display is shown in Fig 13 Input an identical password 1 4 digits twice press OK key again to save it Under the interface shown in Fig 12 press ESC key and input the registered ID number a group of password can be registered for back up or a registered password can be changed Inductive card registration Each employee can register inductive card Under the interface shown in Fig 5 select Inductive Card Registration press OR key the display is shown in Fig 14 Card New Enroll Yes OK No ESC Fig 14 Fig 15 Press OK key to enter the input state for registering numbers After inputting numbers for example 00001 press OK key the display is shown in Fig 15 After slotting the card the card number will be filled in a
20. mation of level 1 menu The structure of level 1 2 and 3 menus are described as follows 2 2 12 Setting Menu Select Data Management using A V in level 1 menu Then press OK to access the level 2 menu which has totally 5 items Move the cursor using A V to select desired option among menus of the same level Press OK to access the sub menus of the selected menu Press ESC to return to the higher level menu Level 4 menu is contained in the Super Administrator and Registered Administrator which are level 3 menus The content of the menu is identical with the level 3 menu under User Registration The structure is shown below Fingerprint Access control User s Manual Level 1 menu Level 3 menu Level 2 menu Note The ID cards are not included in the standard functions and must be used with an external reading head Only the super administrator is entitled to access the following items under the level 3 menu super administrator registered administrator 1 1 safety setting I N safety setting and delete all records In addition when executing Delete registered data the super administrator can only delete the user s registered data and data of an administrator belonging to the same level 2 2 12 Setting Menu In the level 1 menu when the cursor is at Setting click OK to enter the level 2 menu This menu has three setting items and there
21. n the access control terminal and access control management system namely RS485 TCP IP The system configuration is shown in the following diagram Fingerprint Access control User s Manual Schematic for Installation of Access Control Push Button 85 Outdoor Indoor 1 2 Parameters MF850 fingerprint access control Static working current Relay contact 3A 120VAC 28VDC 2 4 TFT color screen 0 C 45 C current Operation temperature Relative operation 20 60 humidity Fingerprint sampler High hardness optical fingerprint sampler Keyboard 20 tact switch Smart KM dual core low consumption Main board structure Core algorithm HAS 8 0 Fingerprint Access control User s Manual Working mode Offline inline Sensitivity level setting Fingerprint password card fingerprint Identification mode password fingerprint card card password card fingerprint password Capacit ee 1 500 fingerprint Capacit of ee 1 000 management record Capacity of in and aed 60 000 out records Communication RS485 TCP IP mode Alarm Alarm for removal prevention alarm for overtime opening alarm for tamper resistance alarm for external input points Fire fighting Available blocking Fingerprint Access control User s Manual Bell ring function 20 groups of rings Doorbell interface Available 1 3 Hardware Installation Installation Procedure The access
22. ng TCP IP communication 255 255 255 000 Note The subnet mask must be consistent to that of the LAN 7 gt Default Gateway 192 168 010 001 Set the default gateway of the LAN when using TCP IP communication 192 168 010 001 Note The default gateway must be consistent to that of the LAN Record setting Record setting includes 2 items The detail description is as follows 1 gt Management record warning Setting Description value No The terminal will not warm when the records are overflowed If the management records are overflowed the terminal will be overwritten with previous management records 1 255 The terminal will inform the overflow of management records based on the set value If the value is 100 warning will be given out from the 901 record If the management records are overflowed the terminal will be overwritten with previous management records Factory setting 29 Fingerprint Access control User s Manual Note If the memory space of user management records is nearly full display or warning tone will be given out please handle the records in time 2 gt In and out record warning Setting Description value No The terminal will not warm when in and out records are overflowed If identification records are full read identification records in the terminal will be overwritten 1 1500 When the remaining record space in the terminal is at the set value warning will be given
23. not be recovered please be careful Safety level setting The detail functions are as follows Setting items Setting Description value 1 1 Safety 1 50 For some users who are difficult to setting pass identification this value can be lowered so as to improve identification pass rate 1 N Safety Based on all users safety level setting value generally it is set as 1 Factory default 1 1 default as 27 1 N default as 1 setting 4 3 Setting It is used to set system parameters Press MENU SETTING to enter the menu including 3 items system setting communication setting and record setting As shown in Fig 26 _25 Fingerprint Access control User s Manual Communication Language Log Setup rime Time Fmt VoiceOut Bri Adjust Initial Setup AOO Fig 26 Fig 27 System setting Under the interface as shown in Fig 26 select System setting press OK to enter it its interface is shown in Fig 27 The detail description is as follows Total number Set the total number of of administrators of access administrators control The factory default is 5 Language Including Simplified Chinese Traditional Chinese and English The interface displays in Simplified Chinese Traditional Chinese and English The factory default is Simplified Chinese Time setting Use the up and down arrows to select correct date numbers to set the date of the access control Time format Year Month Day Press up
24. nt 2010 04 22 password and inductive card Before using users must be registered When registering each user must use an exclusive ID number ID number is the ig number of the user information in the management software corresponding to the data in the access control Each ID number can be registered with 3 fingerprints 1 group of _14 Fingerprint Access control User s Manual password and one inductive card at most D number ranges 1 65535 The standby interface of the access control is shown in Fig 1 Fingerprint registration Each user can register 3 fingerprints at most In standby mode press MENU key enter Menu Data Management User Registration Fingerprint Registration New Registration Input ID Number Press Finger three times Save registration succeeds The detail operation steps are as follows Manager 2010 04 22 1 amp 2 ESC Fig 2 Fig 3 After pressing MENU key the interface will be displayed as shown in Fig 2 If a administrator has been registered the interface is shown in Fig 3 Before entering the menu administrator verification must be done For operating method please see Section 4 1 Under the interface shown in Fig 2 select Data Management press OK key the display is shown in Fig 4 Sep Mananger 20 Manager Level Setting Delete Password Card AllLog Delete Fig 4 Fig 5 Select User Registration Press OK key to enter
25. of management records record 4 6 Shortcut Key Setting There are 4 shortcut keys such as F1 F2 F3 and F4 on the surface of the access control They can be set using the supporting software Their meanings include default definition including F1 Dayshift sign in F2 Dayshift sign out F3 Overtime sign in F4 Overtime sign in enquiry system information voice warning silent warning and communication information display The detail descriptions are as follows 233 Fingerprint Access control User s Manual Dayshift sign in Set the F1 key as the default definition using the software When pressing F1 key on the machine the LCD will display Dayshift sign in The record is dayshift sign in Dayshift sign out Set the F2 key as the default definition using the software When pressing F2 key on the machine the LCD will display Dayshift sign out The record is dayshift sign out Overtime signin Set the F3 key as the default definition using the software When pressing F3 key on the machine the LCD will display Overtime sign in The record is overtime sign in Overtime sign Set the F4 key as the default definition using the out software When pressing F4 key on the machine the LCD will display Overtime sign out The record is overtime sign out System Select one key among F1 F2 F3 and F4 keys information and set it as the System information enquiry enquiry using the softwa
26. ower supply grounding Wigand data input Wigand data 0 input D1_O Wigand data loutput UT DO_O Wigand data 0 output UT Fingerprint Access control User s Manual 1 G C ND Power supply grounding 0 1 OM_ ME 10 interface 1 B 1 COM_ ME 10 interface 2 A 3 Access control interface 2 12P interface on the right of the back definition D Power supply grounding T ALM OUT Output terminal of hidden alarm control T ALM IN Input terminal of hidden alarm control ALM OUT Output terminal of exposed alarm control ALM_IN Input terminal of exposed alarm control 7 OPN_S Door lock switch Power supply grounding Normally closed terminal of lock sensor Normally open terminal of lock sensor 1 6 Fingerprint Placement Guide When installation of the terminal is completed the fingerprint will be registered first which is followed by validating operation The recommended finger for registration is the forefinger and middle finger Fingerprint Access control User s Manual Too deflective Too low Correct pressing manner Correct finger placement method Press with your finger on the fingerprint gathering window Make sure the fingerprint s centre is aligned to the centre of the gathering window as much as possible Finger press method is shown as the following figure Chapter Two Basic Function 2 1 Keyboard The configuration of the keyboard is shown in the following figure T
27. r will be opened only or alarm will be given out only Note Threatened alarm action is effective only when the threatened alarm function is started and only one of above three items can be set as Yes Three fingerprints must be registered The third fingerprint is used as the threatened fingerprint by default When a normal opening signal is given alarm can be removed 6 gt Wigand mode 6 The Wigand output mode is WG26 mode 3 The Wigand output mode is WG34 mode 30 Fingerprint Access control User s Manual Factory setting Note If the Wigand output mode is 26 its external card reader must be WG26 mode If the Wigand output mode is 34 only the external card reader with WG34 mode can be compatible 4 5 System Information It is used check the storage state of the access control press MENU System Information to enter its menu which includes 7 items The detail descriptions are as Check the total number of user registration follows Setting items User registration Administrator registration Fingerprint registration Check the total number of administrator registration Check the total number of fingerprint registration Inductive card Check the total number of inductive card number number registration registration Password Check the total number of password registration registration Check the total number of in and out records Management Check the total number
28. re Press the key the LCD will display the system information on the equipment Voice warning Select one key among F1 F2 F3 and F4 keys and set it as the Voice warning using the software Press the key the warner will give out voice warning Silent warning Select one key among F1 F2 F3 and F4 keys and set it as the Silent warning using the software Press the key the warner will start silent warning Communication Select one key among F1 F2 F3 and F4 keys information and set it as the Communication information display display using the software Press the key the 07 2 Fingerprint Access control User s Manual LCD will display the communication information on the equipment Note If no any action is done for 20 seconds after clocking in the dayshift sign in out and overtime sign in out displaying will disappear automatically If voice warning or silent warning has been started warning can be stopped when a normal opening signal is given out Chapter Five MF 10 Description 5 1 Product Overview MF 10 is a multifunction reader which can be connected with any professional access control and can be seamlessly connected with our company s access control MF 10 features single identification modes such as fingerprint identification password input and card identification It is completely compatible with profession password keyboard readers in present market and can manage fingerprint d
29. rs Identify key input the ID number to be set press OK key GGiteea Fp Pw Card Users Date No to enter the interface shown in Fig 22 press Up WA OK 18 E ESC and Down keys to select the parameter type to be Fig 22 set and press OK key to confirm press Up and Down keys to select parameters and press OK key to confirm and press ESC key to exit and save Setting item description 1 gt Type Include two parameters Attendance and Access Control Users of attendance type are not controlled by the privilege of the access control and do not have the right to open the door only the single identification mode can be used and attendance records will be produced Users of access control type are controlled by the privilege of the access control and have the right to open and close the door 2 gt Time group Each access control user must be distributed to a time group and is controlled by the settings of the time group There are 30 time groups can be selected 3 gt Enable user time section It is a switch setting It controls whether the user uses his own time section or uses the time section of the time group If Yes is selected the user uses his own time section and is not controlled by the time section of the time group 4 gt Time section The user s own time section is the same as the time section of the LO x Fingerprint Access control User s Manual time group If Yes
30. s press to delete the input error data Note The MF 10 can save 2000 fingerprints but it does not save data of password wee wie Fingerprint Access control User s Manual inductive card and identification record data Therefore search and collection of records and other operations relating to records cannot be conducted on the MF 10 they can be conducted on the access control to which the MF 10 is connected Technical Support To obtain more information and technical support you can 1 Read the detailed electronic hardware instruction in the supporting VCD that requires PDF reader for viewing 2 Read the detailed electronic hardware instruction in the supporting VCD that requires PDF reader for viewing to learn information on installation and operation of the management software Appendix Access Control Neworking Schematic l Computer RS43 men Omputer bet work p witch m RS485 communicate 3 a TCP IP Communi E 26 _ 233 z FES ag A O 3a ae g w Sy o 2 5 S No 1 No 2 age Access Access 38 8 control control a LL Fingerprint Access control User s Manual 230
31. s control management software will be confused when acquiring the time attendance record therefore one access control can be set with a OT Fingerprint Access control User s Manual unique number only when connecting to the network 2 gt Baud Ratio Setting items Setting Description value Baud ratio The lower the setting value is the more stable the communication will be the further the transmission distance will be but the transmission speed will be slower Setting value includes 9600bps 19200bps 38400bps and 115200bps Note If RS485 communication mode is selected this value will be effective furthermore the value must be set consistently to the communication ports otherwise no communication can be made It is recommended to use baud ratio 19200 bps 3 gt Port Number Setting Description items 1 9999 Set the software port of the TCP IP communication of the terminal Factory setting Note The port must be consistent to the port number of the software in the PC administration machine 4 gt Communication Password 0 999999 Set the access password when using TCP IP communication Factory setting 5 gt IP Address SIR Fingerprint Access control User s Manual 192 168 10 224 Set the IP address to access the machine when using TCP IP communication 192 168 10 224 Note The IP address in the LAN is unique 6 gt Subnet Mask 255 255 255 000 Set the subnet mask of the LAN when usi
32. s set if the door sensor detects that the door is opened illegally the machine will start alarming The unit is second When this value is set as No the alarm function will not be started Factory setting Note There are three ways to disable the illegal alarm relay 1 Shut down the illegal opening alarm from the controller 2 Send shutdown order to the controller from the host computer 3 After the door is closed give a normal opening lock signal 4 gt Threatened alarm Setting Description a e the threatened alarm function No Close the threatened alarm function Factory setting 5 gt Threatened action 232 Fingerprint Access control User s Manual Setting Set value Description items Open the When identification is done by the third door Open the back up fingerprint the door will be opened only When identification is done by the third back up fingerprint the door will not be opened When identification is done by the third back up fingerprint the alarm will give out silent alarm but the door will not be opened No When identification is done by the third back up fingerprint the alarm will not give out silent alarm and the door will not be opened When identification is done by the third door back up fingerprint the door will be alarm opened and the alarm will give out silent alarm When identification is done by the third back up fingerprint the doo
33. single identification mode when identification is conducted on the MF 10 For detail identification operating steps please refer to Section 5 3 Bro ee Fingerprint Access control User s Manual B Identification on the external inductive card reader is operated as follows The inductive card reader only supports the single inductive card identification way Even the access control is set with multi identification mode the multi identification mode will automatically change to the single identification mode when identification is conducted on the inductive card reader Its operating method is the same as the card slotting method of the access control and the MF 10 Please refer to Section 5 3 3 1 6 Record Searching After you do attendance or go in out records will be saved on the access control You can download and view the records through the supporting management software For detail operating steps please see the instruction of the supporting software 3 2 Daily Use When you go in out daily you press your registered finger on the fingerprint sensor of the outdoor host machine If the identification succeeds the door will be opened and you can go in the door When you go out the door press the open button installed indoor usually it is installed beside the door to open the door Chapter Four Management Operation 4 1 Enter Management Menu Under standby state press MENU key to enter management menu as shown in Fig 2
34. the access control is set with multi identification mode the MF 10 will automatically turn to single identification mode A Fingerprint identification Only 1 N identification mode can be done Press your finger directly on the fingerprint sensor If the identification succeeds the access control will prompt Thank You in voice and the MF 10 buzzer will sound Click Click Click three times If the identification fails the buzzer will sound Click one time only B Inductive card identification Put the inductive card near the inductive area When the inductive card is close enough to the inductive area the MF 10 can identify it and identification will be successful If the identification succeeds the access control will prompt Thank You in voice and the MF 10 buzzer will sound Click one time If the identification fails the buzzer will sound Click one time too C Password identification The input method for password identification ID number number Password number For example If the user ID is 00050 the password is 123 when inputting on the MF 10 the inputting order is OOO50 123 or 50 123 the front 0 can be omitted Note Administrator identification cannot be performed on the MF 10 The MF 10 does not support the password starting with 0 at present Therefore when registering password please do not input any password starting with 0 If any input 66 sk 99 error occur
35. the registration type select interface as shown in Fig 5 After selecting Fingerprint Registration press OK key to enter the new registration interface as shown in Fig 6 Press OK key the display is shown in Fig 7 If it is used for the first time the default ID number is 00001 which can be changed manually Input corresponding ID number then press OK key as shown in 15 Fingerprint Access control User s Manual Finger New Enroll 00001 Yes OK No ESC i EB ESC Fig 6 Fig 7 Press with the same finger for three times according to the instruction on the interface the registration will be successful as shown in Fig 9 New Enroll New Enroll Press Finger 1 00001 0 Sav 0K Ign ESC Fig 8 Fig 9 Note The last digit 0 in 00001 0 represents the first fingerprint and so on The third fingerprint will be taken as the threatened alarm fingerprint by default Press OK key to save the registration After it is saved successfully enter the interface for continuing registration as shown in Fig 10 If you press ESC key you will enter the back up fingerprint registration interface as shown in Fig 11 For backup input the registered ID number use another finger to press for three times and save it If three fingerprints are not identical failure will be prompted and re registration will be required When registering if the system finds similar fingerprints the reg
36. tting is successful press OK key to confirm and press ESC key to exit and save Description 1 gt Multi user The setting range is 0 5 Each time group can be set with 5 users at most 0 means that the multi user function is not enabled If 1 5 is set it means that the multi user function is enabled and the door will be opened only when users in _ 20 Fingerprint Access control User s Manual the same time group sign in out within 30 seconds otherwise the door will not be opened For example If the value is set as 3 the door will be opened only when 3 users in the same time group sign in out within 30 sections 2 gt Time section Three different time sections can be set at the same time at most If a user is not in the range of the set time section the user cannot open the door 3 gt Identification mode Users of this group have 5 identification modes Fingerprint Password Card Fingerprint Password Card Fingerprint Card Password Card Fingerprint Password Note If the multi user function is started the multi identification mode is invalid for multi user multi user can only use single identification mode The input order for time section in 01 01 01 can be random 3 1 4 3 User Control Setting Each user of the access control has an user Group ID control setting parameter In the interface shown in e Vane Fig 18 select User Control Setting press OK SELG Use
37. utomatically Press OK key again to save it Under the interface shown in Fig 14 press ESC key input the registered ID number a back up inductive card can be registered or a new registration ee Fingerprint Access control User s Manual can be done Tips 1 gt If no administrator is registered anybody can change settings of the access control After administrators are registered the management menu for changing settings of the access control cannot be entered without administrators verification Therefore it is recommended to register one administrator at least for managing data and settings of the access control Enter Administrator Registration menu and then register according to the instructions The operating steps of administrator registration is the same as that of user registration 2 gt After administrators are registered non administrator users ordinary users have the rights to do attendance or open the door only 3 gt Administrators include two types Super Administrator and Registration Administrator The Super Administrator has the highest privilege and can conduct any operation on the access control The Registration Administrator has less right than the Super Administrator and can only conduct operations such as User Registration Delete Registration Data of Ordinary Users and check System Information If you lost your management privilege you can cancel the
Download Pdf Manuals
Related Search
Related Contents
CY-8096 Human Hsp27 ELISA Kit Fujifilm FinePix F610 User's Manual bp308 Installationshandbuch 45% - Element14 Samsung UN40H6203AF 40" Full HD Smart TV Wi-Fi Black Samsung SMART Camera NX Mini & 9 mm objektiv (svart) Käyttöopas Eurex Double Movik User Manual DCS 6000 Conference Units rev L Copyright © All rights reserved.