1. S1 S1 S2 S3 S4 Data CR LF SS 2 3 Data S4 weight status ST standstill US not standstill OL overload weight mode GS gross mode NT net mode weight of positive and negative or Uint kg or Ib weight value including decimal point Carriage return Line feed
2. into user parameter setting Function Display Parameter instruction Auto power off OFF 10 0 close auto power off 10 10minutes auto power off 30 30 minutes auto power off 60 60 minutes auto power off Back light mode BL 1 0 close back light 1 auto Back light 2 stay Back light Units switch function UnS 1 0 close units switch function 1 kg Ib 2 b oz 3 kg Ib oz Hold function Hold 1 0 close hold function 1 peak hold 2 data hold 3 auto hold Hold time Ht 1 0 no time limit 1 15 1second 2 15 2 second 3 15 3 second 4 15 4 second 4 2 Communication parameter setting Enter into communication parameter setting after finishing user parameter setting Function Display Parameter instruction Communication mode trn 1 0 close serial communication 1 continuously send 2 manually send 3 command mode Baud rate baud 1 1 9600bit s 2 4800bit s 3 2400bit s 1 1200bit s 0 600bit s Communication mode instruction Continuously send mode the indicator continuously send the Communication format 1 Manually send mode press UNIT 1 second to send the Communication format 1 Command send mode send ASCII R to indicator or hexadecimal 52 indicator back to the Communication format 1 Communication format 1 data all use ASCII upper computer directly recognizes weight as soon as it gets the data CR LF
3. LP7515 Weighing indicator USER MANUAL LIST 1 Instruction 1 1 Function feature 1 2 Technical parameter 1 3 Battery instruction 1 4 overall dimension 2 Installation 2 1 Open package inspection 2 2 Platform connection 2 3 Electrical connection 2 4 Communication interface 3 Basic operation 3 1 Operation panel 3 2 Key function 3 3 Power on 3 4 Power off 3 5 Zero Tare 3 6 Hold 3 7 Kg Lb Oz Unit switch 4 Parameter setting 4 1 User parameter setting 4 2 Communication parameter setting bm A uw an nD QA 1 Instruction 1 1 Function feature Delicate indicator shape with steady performance PCB board is suitable for industrial use or commercial use Low power design longer battery usage time 6 digits 20mm high LCD display with backlight Perfect function Low battery detection and warning shutdown automatically while under voltage Hold function lock the weight Idle mode and Automatic power off function Zero tare function Optional serial output can be connected with big display or PC 1 2 Technical parameter Accuracy class OIML LI Tare range 2 100 max Capacity Initial zero range 10 max Capacity Manually zero range 2 max Capacity Operation temperature amp humidity 10 40 C lt 90 RH Storage temperature 40 70 C 1 3 Battery instruction The indicator use 3 pcs of 5 AAA battery and work about 30 hours If close the backlight mode the battery can last 100 hours When Low battery detecti
4. UNIT Unit switch Move down 3 3 Power on Press ON OFF 1 second to power on self inspection If exceed the zero range it displays ERR6 Or weighing return to zero 3 4 Power off 1 Press ON OFF 1 second to power off 2 Auto power off in low battery 3 Auto power off in 10 minutes see 4 1 OFF to adjust time without no operation 3 5 Zero Tare When weighing exceed the zero range 2 and stable press ZERO to enter into net weighing mode display net weight zero When weighing in the zero range 2 and stable press ZERO to back to gross weighing mode display gross weight zero 3 6 Hold When Hold 1 peak hold mode press HOLD to keep the peak weight it shows the maximum data then press HOLD again to release hold function When Hold 2 data hold mode press HOLD to keep the current weigh and press HOLD again to release hold function or auto release in 15 seconds see 4 1 Ht to adjust time When Hold 3 auto hold mode auto keep the current stable weight Press HOLD to release hold function or auto release in 15 seconds 3 7 Kg Lb Oz Unit switch When Uns 0 close unit switch When Uns 1 kg Ib Unit switch press UNIT to change the unit between kg and Ib When Uns 2 b oz Unit switch press UNIT to change the unit between Ib and oz When Uns 3 kg Ib oz Unit switch press UNIT to change the unit among kg Ib and oz 4 Parameter setting 4 1 User parameter setting Press HOLD and UNIT to enter
5. on and warns light up the low battery icon please change the battery If not change in time it will shutdown automatically When use DC power supply it will not use battery power 1 4 overall dimension ON OFF HOLD po Be ZERO UNIT WEIGHING INDICATOR 2 Installation 2 1 Open package inspection Once you open the package please check all the parts based on the packing list If there are something missing or broken please contact with our after sales department as soon as possible to ensure proper use of the indicator 2 2 Platform connection The indicator can connect with 4 pieces of 3500 load cells at most LP7515 use quick disconnect as below 2 3 Electrical connection Adaptor power supply please insert the adaptor to DC connector of the indicator back cover Battery power supply 3 pieces of 5 battery 2 4 Communication interface RS232 Communication interface via DB9 Pin DB9 Pin DB9 definition 3 Basic operation 3 1 Operation panel Instruction Weight is zero The weighing data is stable G ass Gross weight Net Net weight Fold Data hold Low battery Unit kg ID Unit Ib OZ Unit oz 3 2 Key function Key Weighing Mode Parameter Setting ON OFF Power on off Exit HOLD Hold Confirm ZERO Zero Tare Move left