Home

User Manual

image

Contents

1. ATTENTION __ ran ATTENTION HOSPITAL GRADE PLUG Must Be Connected To Hospital Grade Receptacle Only 915 001 026 REV B PATIENT FALL HAZARD 750 LBS MAXIMUM WEIGHT CAPACITY Page 3 TROUBLE SHOOTING 1 0 Table does not move up or down 1 1 Check power cord connection to main power source 1 2 Make sure main power source is receiving power 1 3 Thermal protector may have activated and you must allow the system to cool down 1 4 Table still does not function after checking the aforementioned possible items call the customer ser vice at 1 800 437 8011 2 0 Tried everything and nothing works to resolve the dilemma call customer service at 1 800 437 8011 SPECIFICATIONS Item TG1847 0 EC 750 Width 4 ft Length 7 ft Ht Range 17 39 nominal Item TG1857 0 EC 750 Width 5 ft Length 7 ft Ht Range 17 39 nominal Item TG1867 0 EC 750 Width 6 ft Length 7 ft Ht Range 17 39 nominal Weight Capacity 750 Ibs lifting Upholstered Top 2 polyfoam with vinyl cover standard Vinyl Coated Nylon amp Herculite optional Has rounded corners with steel frame as a bumper guard Vinyl conforms to California Fire Code 117 Casters Total locking 6 Colson casters standard Frame Heavy gauge steel Finish Polyurethane Pearl Grey standard Porcelain optional Accessories Sit to Stand Guard Rails Various Exercise Accessories available Switch Handheld heigh
2. XPRESSLY LIMITED AND SUBJECT TO THE TERMS HEREIN TO THE REPAIR OR REPLACE MENT OF ANY PRODUCT OR PART WHICH SHALL APPEAR TO BE DEFECTIVE IN THE OPINION OF TRI W G INC THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL TRI W G INC BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES NO CLAIM FOR BREACH OF WARRANTY FOR PRODUCTS OR PARTS FURNISHED HERE UNDER SHALL BE ASSERTED AGAINST TRI W G INC MORE THAN TWENTY 20 DAYS AFTER THE EXPIRATION OF THE WARRANTY PERIOD Page 5 Manufactured and Distributed by STRI W G Phone 1 800 437 8011 Email triwg triwg com 215 12th Avenue NE PO Box 905 Valley City ND 58072 0905 ir Copyright 2015 Tri W G Inc All Rights Reserved
3. event dam age to the frame and cushion while moving down hallway through doorways etc 3 Remove all other packaging material from the table except for the cardboard cushion liner INSTALLATION 1 There is no assembly required 2 Position table in an area having flat level floors so table is not distorted out of alignment and caster brakes will function as intended 3 Casters should be locked at all times except for when moving Casters should be locked when a person is on the table 4 Connect power cord to properly grounded 120 Volt AC receptacle conforming to applicable nationally rec ognized electrical codes 5 Power supply cord serves as disconnect device The socket outlet shall be installed near the equipment and shall be easily accessible IMPORTANT SAFETY PRECAUTIONARY INSTRUCTIONS 1 Once again please have anyone who will be operating this table read the manual before using Operator should understand and practice the precautionary instructions recommended in this manual All users should use common sense and know the limitations and hazards associated with operating the table 2 NEVER place your hands or feet nor the patients hands or feet near any of the working mechanisms of the table when raising or lowering the table Also DO NOT place or leave objects or items of any kind under neath the base frame of the table when operating 3 Whenever you see this symbol AN it means Attention You and or Your Patie
4. il FOR CUSTOMER Ez ASSISTANCE As a future reference we suggest you record the information listed 215 12th Avenue NE below for quick accessibility Valley City ND 58072 0905 Model No Serial No Purchase Date 1 800 437 801 1 Purchased From triwg triwg com www triwg com Tri W G Service 1 800 437 8011 USER MANUAL P N 040115 750 For HI LO MAT TABLE TG1800 SERIES Read this user manual carefully before using Hi Lo Mat Table LIMITED W ARRANTY REGISTRATION CARD ENCLOSED Tri W G Inc INTRODUCTION Thank you for selecting the Tri W G Hi Lo Mat Table The purpose of these operating instructions is to intro duce the authorized user operator in using and working with this device safely and to conduct routine preven tative maintenance procedures on the device For this goal to be achieved it is essential that the authorized user operator carefully read this manual understand and practice the precautionary measures recommended in it PLEASE HAVE ANYONE WHO WILL BE OPERATING THIS TABLE READ THIS MANUAL UNCRATING 1 Inspect for any damage to the table immediately after uncrating If the table is damaged file a merchan dise damage report immediately with the delivering carrier Do not return damaged merchandise to Tri W G unless instructed to do so 2 Keep the cardboard liner on top of the table while moving table to desired location This will pr
5. mful ingress of water Ordinary ANASTHETICS Not suitable for use in the presence of a flammable anesthetic mixture with air or oxygen or nitrous oxide ELEC RATING Input 110 120 Volt AC 60 Hz 2 5 Amp single system Page 2 WARNINGS AND USAGE HINTS Please make note of the meaning of the following warnings and usage hints Note indicates usage information that helps the user to use the product correctly and efficiently or to understand the properties of the product r vc aa Caution warning to inform the user of hazards that re main due to the incomplete effectiveness of protective measures against property damage or personal injury pointer to the possible required special training and per sonal protective equipment Warning warning of Irreparable property damage or Personal Injury that remains based on hazard analysis With reference to protective measures and possible re quired special training and personal protective equip ment Danger warning of life threatening hazards that remain despite hazard analysis With reference to protective i measures and possible required special training and j personal protective equipment i OTHER HAZARDS The manufacturer has constructively and with protective measures minimized the effects of existing hazards Pay attention to the following hazards and the possible countermeasures given in the following
6. nts Safety is Involved 4 During table operation stop the table operation if anything unusual is observed or unusual sounds are heard coming from the table Page 1 OPERATING INSTRUCTIONS Adjust Height To raise or lower the mat table simply touch the up or down arrow key on the hand switch The low voltage hand switch has operating power of VDC mA of 12 50 Duty Cycle System is an intermittent operation 1 minute on 9 minutes off Capacity The table is intended to support 750 Ibs 333 6 Kilograms Casters Locking the casters is accomplished by pushing down or stepping on the back part of the brake pedal firmly To release the brake pedal push down or step on the upper part Intended Use This device is a motorized hi lo mat exercise table intended for medical purposes that can be adjusted to various positions It is used by patients with circulatory neurological or musculoskeletal conditions This device is intended for professional use only MAINTENANCE The mat table is equipped with a strong high performance quiet linear actuator having a long lifetime and vir tually maintenance free however conducting routine preventative maintenance checkups are a must One must routinely check the actuator for wear on the end mounts and connecting bolts for unusual noises for actu ator wobbling when extending or retracting the spindle and that it is operating smoothly as minimums Due to normal wear it may be necessary to re
7. place the linear actuator The actuator is non servicable in the field Call customer service for replacement actuator The gas springs are used to assist the linear actuator in the first stages of the lifting process and may need replacing from time to time due to normal wear If one should notice an oil leak or oil spot on the floor below the gas spring or if table seems to be deficient in power it may indicate the spring needs replacing If opera tor hears an unusual noise while operating the device it may be coming from the gas spring which would indi cate it may need replacing Call customer service to assist in interpreting the nature of the noise Due to normal wear it may be necessary to replace the hand switch or the power cord Call our customer serv ice for replacement parts and or installation instructions Cleaning the vinyl cover is accomplished with a mild detergent and water Do not use Peroxide Hylex Lysol or strong cleaning agents as they will discolor and reduce the life of the vinyl We also recommend diluting some of the well known over the counter cleaners available before using such as 409 cleaner with a ratio of 4 1 at a minimum A soft dust cloth will work to remove dust and lint on the steel frame when necessary Any repair should be performed by trained or certified service personnel SYMBOLS INDICATORS and DEGREE OF SAFETY ZA Attention Consult accompanying documents WATER Protection against har
8. stery Please note the aforementioned limited warranty is limited to original owner and not transferable in the case of Products and twelve months in the case of Parts from the date of delivery from Tri W G Inc or an authorized Tri W G Inc Dealer whichever is later Should defects appear in any products subject to this limited warranty and Parts subject to this limited warranty sold hereunder within the respective limited war ranty period Tri W G Inc will repair or replace under the terms of this limited warranty any defective Part or Parts or provide new or remanufactured Parts when the defective Part or Parts are returned to Tri W G Inc facilities at Buyer s expense upon 20 days prior written notice to Tri W G Inc Buyer will be charged for any replacement Parts when shipped to Buyer by Tri W G Inc When the defective Parts are returned to Tri W G Inc pursuant to Tri W G Inc returned goods authorization charges will be waived This limited warranty does not apply to any Products or Parts which have been damaged through misuse negligence or accident including shipping damage on the part of Buyer or any third party This limited war ranty does not apply to any Product in which Parts other than replacment Parts or Parts approved by Tri W G Inc have been used if said Parts are or may be the cause of failure FOR ANY BREACH OF WARRANTY EXPRESSED OR IMPLIED THE LIABILITY OF TRI W G INC IS HEREBY E
9. t adjusting switch low voltage VDC mA of 12 50 Power supply serves as main discon nect device Electrical 6 5A 120V 780W hospital grade plug NOTICE Design changes may have occurred in the product since this manual was published The technical information found with in this manual was correct at the time this manual was approved for publication Tri W G Inc does not assume any risk or liability for attachments or their effects on this device if the attachments are not manufactured sold by and expressly approved by Tri W G Inc When parts are required use only those parts authorized by Tri W G Inc If any information contained in this publication is not understood the user should contact Tri W G Inc for assistance Page 4 LIMITED WARRANTY This Product or Part is sold by Tri W G Inc under the limited warranties set forth in the following paragraphs Such warranties are extended only with respect to the Purchase of the Product or Part as new merchandise directly from Tri W G Inc or a Tri W G Inc Authorized Dealer and are extended to the ultimate customer purchaser of the Tri W G Inc Product or Part Tri W G Inc warrants that each Product or Part sold hereunder shall be free of defects in material and work manship for the Product warranty period identified as follows Ten Years structural frame Two Years operating system and major moving components One Year hand and foot controls uphol

Download Pdf Manuals

image

Related Search

Related Contents

WorkCentre 4118 Evaluator Guide    Optimmersion User Manual  R8300 Office Dock User Manual  Service Capture User`s Manual - Macomb Intermediate School District  Gebrauchsanleitung .....2  取扱説明書 パワーコンディショナ  Procedimiento para la Medición de Cloro Libre  Nostalgia Electrics NGD-200 Use and Care Manual    