Home
GSM communicator BXGM0001
Contents
1. DIALLING PAUSE abbreviated with PC in the SMS programming messages Dialling Pause means the time that must pass from 0 to 255 seconds between one call and the next Example f you want the communicator to try to call the next number after a pause of 40 seconds send an SMS with the following structure 2 0 lt COMMENT gt P C 14 0 brahms Programming does not necessarily have to take place with an SMS for each parameter to be set n fact you can group all information to be sent to the communicator in a single SMS which may have the following structure Example 2 0 lt COMMENT gt N T 3 s c OIN TT C 0IN 7 P C 4 0 DEFAULT PARAMETERS ON MODULE COMMUNICATIONS ATTEMPTS NT 3 CYCLICAL SEQUENCE SCE ON END SEQUENCE OF CALLS IC OFF DIALLING PAUSE PC 60 seconds With the default settings all numbers in the address book receive a voice message and or SMS when any event occurs that concerns the control unit da 1 2 3 4 5 6 7 8 9 10 voice Intrusion Alarm XXXIX XXX XXX SMS and Voice Silent alarm XXXIX XXX XXX SMS and Voice Help Alarm XIXIX X X X X X X xX SMS and Voice Panic Alarm XIXIXIXIXIXIXIXIX X SMS and Voice Sabotage Alarm XIXIXIXIXIXIXIXIXI
2. area name A connected area name A area name B area name B disconnected output status password 16 lt Comment gt Output output name A OFF output A output B output name B ON Input Status password 17 lt Comment gt Input input A in standby input A input B input B closed S Note Ifyou do not want to receive a message in reply to the SMS you have sent at the end of the message add n The device is equipped with a relay contact that can be used to activate any controllable device by opening or closing a contact Specifically with the message password 25 lt Comment gt you can control impulse contact devices such as the heat regulators of the series TH Bpt set up for remote control TH 125 TH 350 TH 450 Customised SMS sent Reply SMS to Function by the User the User Closing of the dialler auxiliary contact relay password 23 lt Comment gt RELAY ON Opening of the dialler auxiliary contact relay password 24 lt Comment gt RELAY OFF Closing of the dialler auxiliary contact relay for 3 seconds for activation of Bpt programmable thermostats passwords lt COmMmEN RELA TH ON RELAY ON RELAY OFF Relay status request password 26 lt Comment gt Note The password 25 lt Comment gt command sent to Bpt programmable thermostats activates a specific programm For more det
3. in the programming SMS messages Communications Attempts means the number of unanswered calls from 1 to 20 after which the communicator dials the next number in the address book Example f you want the communicator to attempt to call three times the first number in the address book before going to the next one send an SMS to the communicator with the following structure 210 lt COMMENT gt INIT 3 CYCLICAL SEQUENCE abbreviated with SC in the SMS programming messages Cyclical Sequence means that if there is an unanswered call the communicator will not make any other attempts but will go on to call the next number in the address book To cause this to happen send an SMSto the communicator with the following structure 2 0 lt COMMENT gt S C OIN END CYCLE OF CALLS abbreviated with TC in the SMS programming messages With the default setting when an event occurs the communicator calls all of the numbers in the address book whether the telephone call is successful or not his case the programming message will have the following structure 2 0 lt COMMENT gt T C O FIF f you want to interrupt the cycle of telephone calls when a call is successful the programming message will have the following structure 2 0 lt COMMENT gt T C OIN
4. date gt lt time gt Sabotage Alarm Sabotage Alarm lt area name gt lt entry name gt lt date gt lt time gt Technological Alarm Technological Alarm lt area name gt lt entry name gt lt date gt lt time gt Auxiliary Alarm Network Fault Auxiliary Alarm 1 8 lt area name gt lt entry name gt lt date gt lt time gt Network Fault lt date gt lt time gt Reset Network Fault lt date gt lt time gt Battery fault Battery Fault lt date gt lt time gt Fault System On Fault lt date gt lt time gt System On lt user name gt lt date gt lt time gt System Off System Off lt user name gt lt date gt lt time gt System Partially On System Partially On lt user name gt lt date gt lt time gt Alarms Reset Alarms Reset lt user name gt lt date gt lt time gt 24 brahms Reminder of the communicator settings Numbers saved in the address book and their location Position User name 01 02 03 04 05 06 07 08 09 10 11 Mobile Telephone Operator Center Services STATES Numbers enabled to receive PA and type of messages Phone number called number called _Message pia L1 2 3 4 s 6 7 8 9 10 voice sms Intrusion Alarm
5. sent by the mobile telephone operator or from other services carried out by the mobile telephone operator Once the module has been placed in the appropriate containers as described in the previous pages proceed as follows Ensure voltage has been removed to the system Connect the communicator to the system BUS by means of the terminal BUS B2 Connect the terminalsa to the power supplier of the system B2 or to the terminals of the control unit as shown on the diagrams of the following pages Now restore voltage to the system The lighting of the green LED indicates that the module is powered The yellow LED will remain on for a few seconds during which the GSM device will verify mobile reception If after a few seconds the yellow LED switches off the operation was successful If on the contrary the yellow LED remains on this may indicate that there are GSM communication problems related to reception failure or SIM card registration see the chapter Sim Card Assembly Once the installation has been completed the yellow LED will flash only in case of data transmis sion reception on the GSM network A At this point of installation it is essential to teach the device following the instructions for installation of the burglar alarm system to which the GSM module is connected If the red LED flashes it means that communication on the BUS line is active brahms Diagrams for connection to Brahms B2
6. the default one Italian The customisation can be carried out using the SMS messages described in the column highlighted in the table customised SMS sent by the User where in place of the word Comment a customised text can be added CREATE AN ADDRESS BOOK The address book can be easily created via SMS messages structured in such a way that they carry he information necessary for programming the module The address book can contain up to10 telephone numbers Every programming SMS can send up to 5 numbers to the address book These SMS messages must have the following structure SMS no 1 6 lt COMMENT gt first number second number third number fourth number fifth number SMS no 2 7 lt COMMENT gt sixth number seventh number eighth numberl ninth number tenth number Example f the GSM communicator must send or receive messages to from only two numbers the address book programming message will have the following structure 6 lt COMMENT gt 3 9 3 4 7 1 2 3 4 5 6 7 3 9 3 3 3 3 4 5 6 7 8 9 brahms ADD A TELEPHONE NUMBER TO THE ADDRESS BOOK a telephone number needs to be added to the address book proceed as follows Example f the address book contains 5 numbers in order to add a sixth number send the following mes sage to the communicator 2 2 lt COMMENT gt 6 3 9 3 3 3 8 8 8 8 8
7. 0 lt COMMENT gt TC ON 20 lt COMMENT gt TC OFF 20 lt GEN ERAL PREFERENCES gt sc O Ti PROGRAMMING OF THE GE NERAL PREFERENCES DIAL LING PAUSE 20 lt COMME lengh T gt PC pause in seconds ENERAL P PC 40 20 User instructions Srahms Functions that can be performed by SMS By sending specially structured SMS messages you can remotely perform a number of operations on the systems connected to the communicator These commands via SMS in order to be ac cepted by the burglar alarm must meet the following requirements The number from which the SMS command is sent must correspond to one of the numbers in the address book The SMS must contain a valid User Password The user who sends the SMS to a communicator installed on the B2 control unit must have a level of priority which allows him to perform the required operation see B2 control unit instruc tions B2 amp Note On the B2 control units the commands via SMS are accepted only if there is correspondence between the telephone number the User Name and the User password see B2 control unit instructions The following tables list all of the functions that can be performed by SMS A Important Inthe SMS the proper syntax must be perfectly respected i e the name of the areas of the zones of the outputs and of the inputs mus
8. 8 8 This message overwrites a number in position 6 in the address book MODIFY A TELEPHONE NUMBER IN THE ADDRESS BOOK f a telephone number in the address book needs to be modified proceed as follows Example The message shown in the example allows to overwrite the number in position 2 of the address book with a new one that will have to be written after the text 22 lt COMMENT gt 2 2 2 lt COMMENT gt 2 3 9 3 3 3 5 5 5 5 5 5 5 DELETION OF A TELEPHONE NUMBER IN THE ADDRESS BOOK f a telephone number in the address book needs to be deleted proceed as follows Example The message shown in the example allows to delete the number in position 5 of the address book leaving the same position in the address book empty the message has the following syntax 2 2 lt ICOMMENT gt ST I USE OF SPECIAL TELEPHONE NUMBERS IN THE COMMUNICATOR t is possible to allow the messages from a specific telephone number to be sent to the first number in the address book This function can be used to allow the informational messages from the specific mobile telephone operator for example information on the credit to be sent to the first number in the address book to do this it is necessary to know the number for Center Services of the specific mobile telephone operator This number can be obtained by contacting Customer Service The programming message will have t
9. BUS LA Terminal board for Bot BUS Hoasis connection Mi BUS B2 Terminal for connection to BUS B2 BRAHMS C NO Relay contact 12V 1A normally open TAMP Terminal board for TAMPER contact connection ve Terminal board for earth connection Terminal board for connection to power supply from power supplier SW1 TMP When the jumper is connected the tamper contact is disconnected SW2 LCK When the jumper is disconnected the address book cannot be modified via SMS SW3 DFT By powering the module without jumper the default configuration is reset SW4 BTL Boot loader jumper reserved for the Technical Service not to be removed Srahms A ATTENTION Before installing the module it is important to verify that there is an adequate radio receiving signal from the device in the area where the device needs to be installed To do this simply insert the SIM in a mobile phone and check reception If reception is poor the device will have to be installed in another location with a better signal Please be informed that the company Brahms S r l declines all liability in the event of failed transmission failed reception delayed transmission or delayed reception of SMS mes sages by the communicator when these are due to the quality of the reception signal or to any other problem related to the mobile telephone operator s activities charging cost on the communicator remaining SIM credit resulting from messages
10. Dispose of the unit in accordance with current standards Installer instructions brahms General technical characteristics The communicator BXGM0001 is contained gt in a DIN70 module which can be fastened in r the spaces provided in the containers of the mH L BRAHMS burglar alarm control units or in any ci L U electrical enclosure provided with DIN rails Knn Package contents 70 43 5 GSM module Instructions LOST lt DIN rail Antenna z LLALL x mm 2 lm La lial L _ 70 64 5 Technical specifications of the communicator Weight 160 grams Container material PPOX Polypropylene oxide Degree of protection IP 30 Power supply 15 V AC or from the 12 V DC supply line Standby consumption 310 mA with 15 VAC 110 mA with 12 VDC Communication consumption 360 mA with 15 V AC 180 mA with 12 V DC GSM module type Modem GSM GPRS Dual Band 900 1800 MHz Operating temperature from 0 C to 40 C Storage temperature 10 C to 60 C Relative Humidity lt 90 without condensation brahms Installation of the SIM Card and the optional card BXGMOH01 In order to operate the device must be equipped with a SIM card not included in the package to be inserted in the appropriate housing The device can work in conju
11. Silent alarm Help Alarm Panic Alarm Sabotage Alarm Technological Alarm Auxiliary Alarm Networ Battery Fault System On System Off System Partially On Alarms Reset 25 brahms 26 brahms 27 Srahms BPT Spa Centro direzionale e Sede legale Via Cornia 1 b 33079 Sesto al Reghena PN Italia http www bptit mailto info bpt it CE
12. TELEPHONE NUMBERS IN THE COMMUNI CATOR ACTIVATION 21 lt COMMENT gt number for telephone operator service centre 21 lt SPECIAL NUMBER gt 393492000200 USE OF SPECIAL TELEPHONE NUMBERS IN THE COMMUNI CATOR DEACTIVATION 21 lt COMMENT gt 0 21 lt SPECIAL NUMBER gt 0 FIND OUT YOUR REMAINING SIM CREDIT WITH A SMS 8 lt COMMENT gt required message by call operator code number required by the call operator 8 lt CREDIT gt PRE CRE SIN 4916 FIND OUT YOUR REMAINING SIM CREDIT WITH A VOCAL CALL 9 lt COMMENT gt CALL code number required by the call operator 9 lt CREDIT gt CALL 404 DEACTIVATE SMS RECEPTION BY A NUMBER IN THE AD DRESS BOOK 19 lt COMMENT gt position in the address book OFF 19 lt RECEPTION SMS gt 5 OFF REACTIVATE SMS RECEPTION BY A NUMBER IN THE AD DRESS BOOK 19 lt COMMENT gt position in the address book ON 19 lt RECEPTION SMS gt 5 ON Srahms Function PROGRAMMING OF THE GE NERAL PREFERENCES COM MUNICATIONS ATTEMPTS Customised SMS sent by the User 20 lt COMMENT gt NT number of unanswered calls Examples of customized 20 lt GE SMS ERAL PREFERENCES gt NT 3 PROGRAMMING OF THE GE NERAL PREFERENCES CYCLI CAL SEQUENCE PROGRAMMING OF THE GE NERAL PREFERENCES END CYCLE OF CALLS 20 lt COMMENT gt SC ON 20 lt COMMENT gt SC OFF 2
13. X SMS and Voice Technological Alarm XIXIXIXIXIXIXIXIXIX SMS and Voice Auxiliary Alarm XIX XIX XIX XXIX xX SMS and Voice Networ XIXIXIXIXIXIXIXIX IX SMS and Voice Battery XIXIXIXIXIXIXIXIX IX SMS and Voice Fault XIX XIX RIRI X SMS and Voice E System On XIXIXIXIXIXI XIXIXIX SMS and Voice H System Off XIXIX X X X X X X X SMS and Voice S System Partially On XIX X X X X X X X X SMS and Voice Alarms Reset XIX AXI XIX IXI XIXI XX SMS and Voice brahms Function CREATE AN ADDRESS BOOK first 5 numbers Customised SMS sent by the User 6 lt COMMENT gt first number second number third number fourth numberfifth number Examples of customized SMS 6 lt CREATE ADDRESS BOOK gt 393471234567 393333456789 CREATE AN ADDRESS BOOK second 5 numbers 7 lt COMMENT gt sixth number seventh number eighth num ber ninth number enth number 7 lt CREATE ADDRESS BOOK gt 393471234567 393333456789 ADD A TELEPHONE NUMBER TO THE ADDRESS BOOK 22 lt CO ENT gt position in the address book telephone mber lt ADD NUMBER gt 393338888888 MODIFY A TELEPHONE NUM BER IN THE ADDRESS BOOK 22 lt CO the add T gt position in ok telephone umber ODIFY NUMBER gt 393335555555 DELETION OF A TELEPHONE NUMBER IN THE ADDRESS BOOK 22 lt CO ENT gt position in the address book 22 lt DELETE NUMBER gt 5 _ USE OF SPECIAL
14. ails refer to the programmable thermostats manuals For instance in order to close the auxiliary contact relay the following SMS can be customized and used password 23 lt CLOSE RELAY gt 23 brahms Messages to user by voice and SMS for B2 control units In case of alarm fault or variation in the status of the system the communicator can send a voice message and or SMSto the user numbers in the address book that are enabled according to programming Intrusion ntrusion Alarm DI Intrusion Alarm lt perimeter area gt lt porch door gt lt 15 05 07 gt lt 14 32 gt In the following table in the column SMS message received you can read SMS alarm messages that the communica or sends to the numbers of the address book The part of the message in bold face and in quotation marks is the same one the user will receive in voice form ALARMS STATES Event type Intrusion Alarm SMS Message received In bold face between quotation marks the message that arrives in voice form Intrusion Alarm lt area name gt lt entry name gt lt date gt lt time gt Silent alarm Silent alarm lt area name gt lt entry name gt lt date gt lt time gt Help Alarm Help Alarm lt area name gt lt entry name gt lt date gt lt time gt Panic Alarm Panic Alarm lt area name gt lt entry name gt lt
15. ay the following SMS can be customized and used password 23 lt CLOSE RELAY gt brahms Programming of the communicator through SMS The BXGM0001 communicator allows remote control and signalling functions via the receipt and sending of SMS messages from and to the telephone numberscontained in the address book saved in the internal memory of the communicator itself A If you are using the telephone communicator on BRAHMS B2 systems all of the following settings can be programmed in a simple intuitive way via the interface and the touch screen of the B2UC0002 terminal without the aid of SMS see the B2 instruction manual B2 A Important Before starting programming the address book via SMS make sure that the jumper SW2 LCK is connected With the jumper disarmed the address book can be programmed only from B2 control units via the interface and the touch screen of the terminal B2UC0002 The communicator when purchased can receive programming messages sent by any telephone number It is therefore advisable once the programming of the address book has been com pleted to disconnect the jumper SW2 It is important to enter the appropriate international dialling code before the numbers that are being saved in the address book 39 for Italy The SMS messages that are sent to the GSM module can be customised allowing them to be memorised and subsequently transmitted more easily or written in a different language from
16. brahms GSM communicator BXGM0001 Installer and User manual 05 02 10 24852600 Srahms Use and Applications The modules consists of a telephone communicator on a GSM network for BRAHMS model burglar alarms B2UC0002 The device lets you remotely control the main functions activation deactivation sectioning etc of the BRAHMS burglar alarm where it is installed by sending SMS messages The communicator when properly programmed is capable of sending voice or SMS messages or both which inform the user of events that have occurred that concern the system The SMS messages that are sent to the GSM module can be customised allowing them to be memorised and subsequently transmitted more easily or written in a different language from the default one Italian The customisation can be carried out using the SMS messages described in the column highlight ed in the table customised SMS sent by the User where in place of the word Comment a customised text can be added The device is also equipped with a normally open relay contact which can be used to activate TH Bpt heat regulators designed for remote control or any other device set up for this purpose controlled through the opening or closing of a contact By adding the optional card BKGMOH01 you can use the module in mixed BRAHMS burglar alarm systems in conjunction with BPT HOASIS home automation systems A ATTENTION The BXGM0001 dialler is compat
17. ced in any non metallic container If the module is installed inside a DIN box move the seat of the antenna into the appro priate additional hole on the shell thus allow ing its correct closure Assembly in the plastic container B2CTPLO1 on BRAHMS B2 control unit Assemble the DIN rail provided on the bottom of the container screwing it into the holes and fasten the module fig 1 Assembly in the metallic container B2CTME01 on BRAHMS B2 control unit Assemble the DINrail provided on the bottom of the container screwing it into the holes and fasten the module fig 2 A ATTENTION If the module is installed inside metal con tainers use the optional antenna model BX ANGMO1 by placing it outside the container as shown in figure 2 brahms Terminal boards and connections Optional auxiliary RS 232 connector to interface battery connector the module with a PC Green LED Voltage present Yellow LED GSM transmission reception in progress Red LED transmission reception on line BUS B2 in progress Connection for antenna SIM Card SIM Card housing connector for assembly of card Hoasis BPT Jumper SW1 TAMPER disabled Jumper SW2 address book protection LA B2 c NO TAMPER 00000000 lumper SW4 LO JL IL IL 4 boot loader BUS BUS C NO TAMP jumper WS LA B2 default reset
18. do not tamper with it Use original spare parts Installation programming commissioning and maintenance of the product must only be per formed by qualified technicians who have been properly trained in compliance with current standards including compliance with accident prevention Operate in sufficiently lighted areas that are conducive to health and use tools utensils and equip ment that are in good working order Upon completion of installation always check for correct operation of the unit and the system as a whole Do not install the device outdoors or in areas where it is exposed to seepage or splashes of water Handle the device with care It contains electronic parts that are fragile and sensitive to humidity The electronic cards can be seriously damaged by discharges of static electricity If they are to be handled wear suitable clothing and anti static footwear or at least ensure static electricity has been discharged by touching with the fingertip a metallic surface connected to the earth system e g the chassis of a household appliance Weld the joints between wires to prevent false alarms caused by oxidation of the wires The electrical system must comply with current standards in the country of installation Failure to comply with the above instructions may compromise the unit s safety The installer must make sure that the information for the user where applicable is present on the devices
19. eral Preferences of the communicator through SMS Page 17 Communications attempts 7 Cyclical SEQUENCE sis a Sa KETE ainn 7 Endicycle of calls vcs suine 7 Dialling PAUSE LD pira 7 Default parameters on module 8 User instructions Functions that can be performed DY SMS si a 5 se pa Page 22 Messages to user by voice and SMS for B2 control units Page 24 Reminder of the communicator settings 0 cece eee Page 25 brahms Safety Warnings A ATTENTION After removing the packaging check the condition of the unit The packaging items plastic bags expanded polystyrene etc must not be handled by children as they may be dangerous Carefully read the instructions before starting installation Perform work as specified by the manufacturer Before connecting the equipment make sure that the rating plate data corresponds to that of the distribution network An omnipolar switch with contacts separated by at least 3mm must be installed upstream on the equipment on the electric system of the building The manufacturer declines all liability for any damage as a result of improper incorrect or unrea sonable use Before performing any cleaning or maintenance operation disconnect the equipment from the power supply network by opening the system switch In case of failure and or malfunction of the device detach it from the power supply and
20. ermostats BB008 e OH GSM CN1 as Fel Programmable thermostats can be Ta connected to this contact such as Ja Bpt TH 450 TH 350 TH 125 or any other device that can be remotely svia controlled via the opening closing of a la a relay cal 230V K TRANSFORMER L 230Vac Fig 6 The device is equipped terminals C NO of terminal board M1 with a relay contact that can be used to activate any controllable device by opening or closing a contact Specifically with the message password 25 lt Comment gt you can control impulse contact devices such as the heat regulators of the series TH Bpt set up for remote control TH 125 TH 350 TH 450 Customised SMS sent Reply SMS to Function by the User the User Closing of the dialler auxiliary contact relay password 23 lt Comment gt RELAY ON Opening of the dialler auxiliary contact relay password 24 lt Comment gt RELAY OFF Closing of the dialler auxiliary contact relay for 3 seconds for activation of Bpt programmable thermostats ee RELAY THON RELAY ON RELAY OFF Relay status request password 26 lt Comment gt S Note The password 25 lt Comment gt command sent to Bpt programmable thermostats activates a specific programm For more details refer to the programmable thermostats manuals For instance in order to close the auxiliary contact rel
21. he following syntax 2 1 lt COMMENT gt number for telephone operator service centre n order to deactivate the function enter 2 1 lt COMMENT gt 0 FIND OUT YOUR REMAINING SIM CREDIT n order to find out the remaining credit of your SIM it is necessary to send an SMS specifically struc ured depending on your telephone operator preceded by the word 8 lt COMMENT gt or 9 lt COM MENT gt Some operators for example Telecom Italia Mobile require a message consisting of text number in this case the message will have the following syntax 8 lt ICOMMENT gt required message by call operator code number required by the call operator 8 lt CREDIT gt PRE CRE SIN 4916 brahms Other Operators Vodafone Italia for example require a simple vocal call to be sent to a number required by the call operator The message will have the following syntax 9 lt COMMENT gt C AJL L code number required by the call operator 9 lt CREDIT gt CJA L L 404 DEACTIVATE SMS RECEPTION BY A NUMBER IN THE ADDRESS BOOK The default settings allow an event to be reported to all users through an a v
22. ible with B2UC0002 equipped with terminals of version 1 0 or greater The version of the terminal can be obtained from the packaging label from the label on the back of the terminal or it can be read directly on the screen by pressing the button B2 brahms Use and Applications Page 2 Safety warnings Page 4 Installer instructions General technical characteristics Page 6 Contents of package 6 Installation of the SIM card and the optional card BXGMOH01 Page 7 Positioning of the device Page 8 Assembly of the antenna 8 Assembly in the plastic container B2CTPLO1 on BRAHMS B2 control unit 8 Assembly in the metallic container B2CTMEO1 on BRAHMS B2 control unit 8 Terminal boards and connectors Page 9 Commissioning Page 10 Connection diagrams Page 11 Programming of the communicator through SMS 4 Create an address book Add a telephone number to the address book 15 Modify a telephone number inthe address book c iirine ana 5 Deletion of a telephone number inthe address DOG eee 5 Use of special telephone numbers inthe communicator 5 Find out your remaining SIM credit 5 Deactivate SMS reception by a number in the address book 6 Programming of the Gen
23. nction with the Hoasis Bpt home automation system by adding the interface module optional BXGMOH01 to be assembled as shown in the figure To do this unscrew the two fastening screws and remove the dialler cover Do this making sure that you do pull out the antenna wire S SIM card not included SIM card housing A og Optional module BXGMOH01 for interfacing with Hoasis BPT home automation system A A ATTENTION If the SIM card is new prior to inserting it into the communicator make a call by inserting it into a mobile phone thus allowing the mobile telephone operator to register the card The device requires that the SIM cards are activated only vocally and by SMS No SIM Data Before carrying out the programming operation deactivate the SIM card PIN code A ATTENTION The electronic cards can be seriously damaged by discharges of static electricity If they are to be handled wear suitable clothing and anti static footwear or at least ensure static electricity has been discharged by touching with the fingertip a metallic surface connected to the earth system e g the chassis of a household appliance Srahms Positioning of the device Y il Assembly of the antenna On the shell of the module there is a seat for the insertion of the antenna included in the package The antenna provided is swivel type so that it can be pla
24. oice message and an SMS However it is possible to allow some numbers to receive only voice messages Example f you wish to prevent the fifth number in the address book from receiving SMS but rather only voice messages the programming message will have the following syntax 1 9 lt COMMENT gt _ 5 O F F n order to reactivate SMS reception by the number the programming message will have the fol owing syntax 1 9 lt COMMENT _ 5 JOIN amp Note In the Brahms B2 type control unit by means of the B2UC0002 terminal it is possible to deactivate the voice message as well amp Note Brahms declines all liability in case of transmission of SMS by the mobile telephone operator that decrease the communicator s remaining SIM credit On page 23 the User can take note of the main programmed parameters for his own benefit and as a written reminder in case of future work on the system brahms Programming of the General Preferences of the communicator through SMS A If you are using the telephone communicator on BRAHMS B2 systems all of the following settings can be programmed in a simple intuitive way via the interface and the touch screen of the B2UC0002 terminal without the aid of SMS see the B2 instruction manual B2 Also by means of correctly structured SMS messages you can set the following preference COMMUNICATIONS ATTEMPTS abbreviated with NT
25. systems a BXGM0001 Mi NO MO og BUS LA S BUS B2 S M2 9 L 0 B2AL0001 z WD I EB lo and ag B2SEAL02 Ka O ug yE S C 30 V g a BU Mi S BUS 10 BUS 15 12v H BAT TIS B2IPPA01 No TAMPER S E id 7 SS G BB065 B2UC0002 BB065 SE E BUS L 230Vac Fig 4 11 Srahms Connection of BXGM0001 card BXGMOH01 in mixed system comprised of Hoasis BPT home automation Brahms B2 burglar alarm OH A 01 OH RI M3 L n f l OH MA BXGSMO01 tk j M1 5 aia il BUS L a S BUS 82 3 OH T 01 M2 l FAA Raise B2AL0001 n A n l B2SEAL02 M2 o 19 i Teel 24 v E lmn ES di rene sov 5 Mi S Bus 2 RIE B2IPPA01 tev t 3 sa TS TAMPER pe BB065 B2UC0002 BUS BB065 S L 230Vac Fig 5 ZA ATTENTION f the GSM module is installed in mixed systems of BRAHMS B2 and HOASIS BPT is it necessary to install on the module BKGM0001 the card BXGMOH01 optional so that the module can interface with both systems 12 brahms BXGM0001 connection to Bpt series TH programmable th
26. t the same as inserted in the programming windows of the control unit and the sequence of numbers that make up the password must be correct The SMS messages that are sent to the GSM module can be customised allowing them to be memorised and subsequently transmitted more easily or written in a different language from the default one Italian The customisation can be carried out using the SMS messages described in the column highlighted in the table customised SMS sent by the User where in place of the word Comment a customised text can be added For instance in order to arm the system the following SMS can be customized and used password 10 lt Arming System gt 22 brahms Functions which can be performed by SMS on the control units BRAHMS B2 System arming password 10 lt Commen System On Input User 01 lt date gt lt hour gt System disarming password 11 lt Commen System Off Input User 01 lt date gt lt hour gt Partial arming password 12 lt Commen area name 1 on area name area name 1 on 2 off area name 2 off Silence password 13 lt Commen Command Executed Setting of physical status password 14 lt Commen Output output name A on of outputs output name A on output name B on output name B off System status password 4 lt Comment gt System safety failure in pro gress on failure not reset Area Status password 15 lt Comment gt Area