Home

TandD TR-73U User manual

image

Contents

1. DATA ENDLESS DATA ENDLESS IT IT sta Oot 15 seconds 15 minutes When the desired recording interval appears stop pressing the lt INTERVAL gt button Within a few seconds the current measurement readings will return to the display and the setting will be finished By pressing the lt INTERVAL gt button during recording or while waiting for a programmed recording to start via the provided software the currently set recording interval will be displayed Changing the LCD Display Mode from Main Unit Button You can make or change the LCD display settings from the lt DISPLAY gt button on the front of the TR 73U main unit 1 By pressing the lt DISPLAY gt button on the front of the unit you can change the screen display lt DISPLAY gt button 2 If the LCD display shows three channels readings alternatively it will show one channel as a fixed display by pressing the button By pressing the button again the LCD display pattern will be set for displaying three channels alternatively If the display has been set for a fixed channel with each pressing of the button the channel display will change 12 13 Specifications Device Type TR 73U Measurement Items Barometric Pressure Temperature Humidity eee acer 1 Channel 1 Channel 1 Channel with Internal Sensor 750 to 1100hPa 10 to 60 C with External Sensor 750 to 1100hPa 0 to 50 C 10 to 95 Responsivene
2. EX Be careful of electrocution Denotes a forbidden action Inside or near the symbol may appear another symbol giving details EX Do not use in wet areas Denotes an action that you must take Inside or near the symbol may appear another symbol giving details EX Unplug power plug from outlet A WARNING When installing and using this product make sure to follow all warnings and directions from your computer manufacturer Do not take apart repair or modify the main unit Doing so may cause fire or electrocution If water or a foreign body enters into this unit immediately remove the batteries and stop using Continued use may cause fire or electrocution Do not use this unit in wet or humid places such as a bathroom It may cause a fire or other trouble including malfunction Store main units sensors batteries and communication cables out of the reach of children It is dangerous to touch or swallow batteries If any smoke or strage smells are emitted from the unit immediately remove the batteries and stop using Continued use may cause fire or electrocution PO o Oo ee This device is designed to measure and record temperature and humidity Do not use it for any other purpose than to measure and record temperature and humidity A CAUTION This unit is not water resistant If the unit gets dirty wipe it with a clean cloth and a mild detergent Do not expose the u
3. Thermo Recorder TR 73U User s Manual Thank you for purchasing our product Carefully read this instruction manual before using this unit Copyright T amp D Corporation All rights reserved 2013 01 16504480003 5th Edition Notices about this User s Manual In order to properly use this product please carefully read this manual before using T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corporation Microsoft and Windows are registered trademarks of Microsoft Corporation USA and are binding in the USA and all other countries Windows Vista is a registered trademark of Microsoft Corporation USA Company names and product names are trademarks or registered trademarks of each company Specifications design and other contents outlined in this manual are subject to change without notice On screen messages in this manual may vary slightly from the actual messages Please notify the shop where you purchased this product or T amp D Corporation of any mistakes errors
4. operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Safety Precautions and Instructions E To ensure safety obey all of the following warnings The following items should be strictly obeyed for the safe usage of this unit and for protecting yourself and other people from bodily harm and or damage to property Before using make sure to carefully read understand and follow the safety rules and precautions for our products as outlined below Explanation of Symbols Explanation of Warning Symbols These entries are actions that absolutely under no circumstance should VAN be taken The taking of such an action may cause serious personal WARNING physical damage or death These entries are actions that if taken may lead to physical injury or CAUTION damage to persons or things Explanation of Picture Symbols Denotes an important warning or caution Inside or near the symbol may appear another symbol giving details
5. to 95 RH Amount of Recorded Data 8000 readings x 3 channels One channel can record and hold up to 8000 measurement readings At the longest recording interval of 60 minutes recording can continue consecutively for 1 year 10 Months of Operation with just 1 AA Alkaline Battery Our low energy consumption design gives you ten months of continuous operation with only one AA alkaline battery This gives you the freedom to use the data loggers in places where they can be left alone for long periods of time such as in transportation or warehouse NOTE Battery life varies depending upon the type of battery the measuring environment the frequency of communication and the ambient temperature in which it is used Specifications and explanations used in this User s Manual are based on operations carried out with a new battery and are in no way a guarantee of your actual battery life Also if the recording interval is less than 10 seconds battery life will be much shorter Battery Life Warning Display When the battery power becomes low a battery life warning signal will appear in the unit s LCD display If the battery power becomes even lower the unit will automatically go into sleep mode in order to protect the data 15 Recording Intervals Select from 15 recording intervals from 1 second to 1 hour to meet your needs Select from 2 Recording Modes One time Mode When the number of recorded readings reaches 8000 FULL
6. 12 Specifications n ile aecel tal ete Ee i Aad cea etd Optional Accessories Thermo Recorder TR 73U Warranty viii About Thermo Recorder TR 73U E Outline TR 73U Thermo Recorder is a data logger capable of measuring displaying and recording temperature humidity and barometric pressure data TR 73U has a total of three channels one temperature one humidity and one barometric pressure channel The data recorded into the TR 73U units can then be downloaded quickly via USB cable to your computer whereby with our exclusive software you can easily process the data into graphs tables save to files and or print it out Moreover it is possible to connect more than one unit at the same time E Basic Functions Barometric Pressure Measuring Range 750 1100hPa The TR 73U with the internal barometric pressure sensor can measure and record ina range of 750 to 1100 hPa Temperature Measuring Range 40 110 C The TR 73U with the sensor included in this package can measure and record in a range of 0 to 50 C but by purchasing one of our optional sensors it is possible to measure and record in the wider range of 40 to 110 C Please take a look at our full range of optional sensors to find one to match your application Humidity Measuring Range 10 95 RH The TR 73U with the sensor included in this package can simultaneously measure and record temperature in a range of 0 to 50 C and humidity in a range of 10
7. anges occur the humidity measurements may appear abnormal Once the sensor s temperature becomes stable the measurements will return o normal This sensor is not waterproof Do not get wet o gt gt e When measuring with the temperature humidity sensor in an environment of 0 o 50 C and less than 30 RH the measurements may sometimes fluctuate This is not abnormal vi vii Cautions about using the Sensors Handling the temperature humidity sensor The service life of humidity sensors can vary greatly depending on operating environment Periodic calibration may be required During use the temperature humidity sensor will accumulate impurities dirt on the surface of the sensor is being used in a bad environment smoky or dusty places it may be necessary to change the sensor sooner When the temperature humidity sensor is not being used please place it in the attached vinyl bag with the drying agent included and store it in a cool dark place with a temperature of between 5 to 25 C and a humidity of below 30 RH Attached to the temperature humidity sensor are two stickers a wetness detection sticker and a temperature detection sticker If either of the stickers shows abnormality you should change the old sensor to a new one immediately Wetness Detection Sticker o Temperature Detection Sticker Wetness Detection Sticker Informs you that the sensor has been wet Normal Abnormal Under norma
8. e unit will turn off During recording the power cannot be turned off Please stop recording first and then turn off the power Even if the power has been turned off the recorded data will be saved However if the battery power is totally lost all data will be lost so please download data as soon as possible to avoid losing any necessary data Connecting the Sensors E Connect the Sensor To avoid poor connections be sure to push the sensor connector securely into the jack When using the temperature humidity sensor in environments where the temperature is 0 to 15 and humidity under 30 RH there may occur changes in measurement readings This is not a malfunction NOTE If a sensor extension cable is being used with the data logger connected by USB to your computer electromagnetic waves may cause large errors in measurements For details about handling the temperature humidity sensor please refer to page vii Cautions about using the Sensors of Safety Precautions and Instructions Starting Recording from Main Unit Button By pressing the lt REC STOP gt button on the main unit you can start a recording session immediately If you wish to make changes to the device name channel name recording mode or to any other recording conditions you must make those settings by connecting the device to your computer lt REC STOP gt button E Start Recording Press in the lt REC STOP gt bu
9. ent for the display will appear Measurements and Messages Area Current measurements or operational messages such as FULL or SLP will appear Installing the Battery 1 Remove the battery cover form the back of the unit 2 Insert 1 AA alkaline battery making sure that the and are in the correct direction Always use a new battery 3 Replace and close the battery cover Changing the Battery 1 When battery power becomes low a battery life warning signal will appear in the unit s LCD display If at this time you change the battery recording will continue uninterrupted and all data will be saved for downloading N If the battery is not changed and power becomes even lower SLP will appear in the LCD display The unit will automatically go into sleep mode in order to protect the data and all normal operations will stop If you change the battery at this point it is still possible to download all saved recorded data 3 If the battery is further left unchanged the display will automatically shut off If all battery power is lost all data will be lost as well NOTE If a unit is left without a battery for more than 2 minutes all data will be lost so please work quickly when changing the battery Turning ON the Power 1 By holding in the POWER switch at the left side the unit will turn on POWER Switch Turning OFF the Power By holding in the POWER switch th
10. essure conditions may leak and cause a malfunction Please do not insert your fingers or any foreign objects into any of the devices jacks Do not use any other batteries than those that are specified in this User s Manual It may cause a fire or other trouble including malfunction CID OPS gt Do not use or store the Thermo Recorder in any of the following places Doing so may cause electrocution fire and or other adverse effects to the device and or your computer Areas exposed to direct sunlight This will cause the inside of the device to become overheated and may cause fire deformation and or other damage including malfunction Areas prone to strong magnetic fields This may cause damage including malfunction Areas exposed to water leakage This may cause electrocution or other damage incluing malfunction Areas exposed to excessive vibration This may cause injury malfunction damage or loss of proper electrical contact Areas near fire or exposed to excessive heat This may cause damage including malfunction and deformation Areas prone to smoke duct and dirt This may cause damage including malfunction Cautions about using the Sensors Cautions about using the temperature humidity sensor TR 3100 The sensor can measure temperature within the range of 0 to 50 C and humidity within the range of 10 to 95 RH Only use the sensor within these ranges If extremely severe temperature ch
11. l conditions black dots pig Under abnormal conditions it will will appear on a white turn to red Temperature Detection Sticker Informs you that the sensor measured a temperature measurement over 60 C Normal Abnormal Under normal conditions the Under abnormal conditions the number 60 will lightly appear on a number 60 will clearly appear on a pinkish white background red background Table of Contents Notices about this User s Manual Compliance Information Safety Precautions and Instructions E To ensure safety obey all of the following warningS 0 cceeeeee iii E Explanation of Symbols iaiia a a S iii About Thermo Recorder TR 73U E Outline E Basic FUNCHOMS aA a AE A N 1 Package COOS rana eraen kapana ED rA e R EEEE KESAEN Ea 3 Betore USING s ccccecscctescscvssigegcassiedeecavstacgsoidesenasntcesttvaesugtctentnteettpebianactecd 4 Part Names and Functions E Part Names and Functions ME LCD Displays iccessccsscsnesisssscsjesersestetsseacondsctcseiesoeinsendecesdinetisassteiesessesberss 6 Installing the Battery aoirean aiios Na aE iA re A aE 7 Turning ON the Power Connecting the Sensors E Connect the Sensor Starting Recording from Main Unit Button ccccsccceeeeeeeeseseseseseeeeees 10 E Start Recording E Stop Recording Setting Recording Interval from Main Unit Button Changing the LCD Display Mode from Main Unit Button 008
12. nit to harmful gases or chemicals It may cause corrosion and or other danger to the unit and to people handling the unit Do not use batteries other than specifies Doing so may cause fire or damage Battery terminals may provide insufficient contact due to age or vibration This may lead to data loss Condensation may occur if the units is moved from one environment to another where the difference in temperature is great Use the unit in an environment where the ambient temperature is great Use the unit in an environment where the ambient temperature is from 10 to 60 C and the humidity is 90 RH no condensation or less gt PO To prevent damage to the unit from static electricity remove static electricity from your body by touching metal aroung you door knob window frame before touching the unit Static electricity may cause not only damage to the unit but may cause breaks in or a loss of data If the unit will not be used for period of time for safety reasons please remove the battery If left in the unit it may leak and lead to malfunctioning Please take extra caution when plugging in and pulling out the USB plug while another USB device such as CD RW HDD is in operation It may cause problems to your CD RW or other device We shall not guarantee the operation of our device if you have connected it to your computer using a USB hub or a USB extension cable Batteries used under low pr
13. o install the application and the USB driver Before connecting this product to a PC with a USB cable it is necessary to first install the application and the USB driver If you use the USB cable to connect the product to a PC before installation the USB driver may not properly install If you have connected the product to a PC without first installing the driver please make sure to press Cancel in the Installation Wizard window when it pops up the PC screen and then disconnect the USB cable from the product For details about making TR 73U Unit Settings or about Downloading Data see the explanation in the Software User s Manual and or the Software Help If you are using Windows 8 carry out operations on the desktop which can be accessed via a tile on the Start screen E Windows 7 Vista nate tee Pr ae Cancel nt no ates Button E For other Windows Operating Systems The screen shot below is from Windows XP For other Windows OS there is also a Cancel button in the lower right of the screen Your screen may differ slightly if you are using a Windows OS other than XP Cancel Button Part Names and Functions E Part Names and Functions FRONT lt DISPLAY gt lt INTERVAL gt lt REC STOP gt button button button DISPLAY Pressing this button will change the LCD Display Mode INTERVAL Pressing this button will display the currently set recording interval REC STOP Pres
14. or unclear explanations in this manual T amp D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit Please be fully aware of this before using our product Some of our products which come under the category of strategic goods in foreign trade law need the permission of the Japanese government to be exported outside of Japan Please read the warranty and provisions for free repair carefully Compliance Information Radio EMC and Safety Regulations This device complies with Part 15 of the Federal Communications Commission FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is
15. ove are subject to change without notice Optional Accessories TR 07K2 Wall Attachment Wall Attachment 4 t Included f screws x 2 double sided tape x 1 52 US 15C USB Communication Cable Cable Length a about 1 5 m aS b s For product information or questions contact us at T amp D corporation Shimadachi 817 1 Matsumoto Nagano 390 0852 Japan Monday to Friday 9 00 12 00 13 00 17 00 excluding company holidays GMT 9 00 Tokyo Time Web Site http www tandd com Thermo Recorder TR 73U User s Manual Copyright T amp D Corporation All rights reserved 2013 01 5th Edition This is printed on recycled paper 14
16. sing this button will start or stop recording LEFT SIDE RIGHT SIDE Sensor Jack USB Cable Jack Power Switch Serial Cable Jack 1 1 Not supported in TR 73U E LCD Display ee DATA com ENDLESS ONETIME Recording Mark The recording condition will appear ON Recording in progress BLINKING Waiting for programmed start Data Capacity Scale After every 2000 readings the scale will be marked from left to right COM Mark This will appear when data is being sent or received ON USB cable is connected BLINKING In communication with computer Recording Mode One time Mode When the number of recorded readings reaches 8000 FULL will appear in the unit s LCD display and recording will automatically stop Endless Mode When the number of recorded readings reaches 8000 the oldest data readings will be overwritten and recording will continue Battery Life Warning Signal When the battery power becomes low a mark will appear on the LCD of the main unit If the battery power becomes even lower SLP will appear and normal operations will stop Please change the battery as soon as the Battery Warning Mark appears IMPORTANT If the main unit remains in sleep mode for about 1 month without a change of battery or if the battery is left out of the unit for more than 2 minutes all recorded data will be lost Unit of Measurement The unit of the measurem
17. ss 4 internal Sensor seconds or 40 seconds At a recording interval of 12 minutes Thermal Time Constant 9 minute or more 40 seconds 5 RH Pipettes epee 1 5hPa Average 0 3 C At 25 C 50 RH ae oo 0 1hPa 0 1 1 RH Sensor Barometric Pressure Thermistor Macromolecular Sensor Humidity Sensor Recording Interval Select from 15 choices 1 2 5 10 15 20 and 30 seconds 1 2 5 10 15 20 30 and 60 minutes Recording Capacity 8000 Readings x 3 channels Recording Modes Endless Mode Overwrite oldest data when capacity is full One Time Mode Stop recording when capacity is full Power AA alkaline battery LR6 x 1 Battery Life About 10 months 1 Interface USB Communication Weight of Main Unit About 62 g including one AA battery Dimensions H55mm x W78mm x D18mm Working Environment Temperature 10 to 60 C for Main Unit Humidity under 90 RH without condensation Accessories included in package Temperature Humidity sensor TR 3100 x 1 AA alkaline battery LR6 x 1 USB communication cable cable length1 5m Software x 1 User s Manual Warranty x 1 1 Battery life depends upon the measuring environment communication frequency recording interval and quality of the battery being used Also if the recording interval is less than 10 seconds battery life will be much shorter It is possible to change the battery during recording The specifications listed ab
18. tton on the front of the unit until the REC mark appears in the display When displayed recording has begun REC mark DATA com ENDLESS lights up Liotta ah Ab hPa NOTE By starting a new recording session all data currently saved in the unit will be erased Even if the unit is waiting for a programmed recording to start via the provided software by pressing the lt REC STOP gt button until the REC mark appears you can start a new recording session immediately E Stop Recording You can stop a recording session by pressing the lt REC STOP gt button until the REC mark disappears from the display When it has disappeared recording has stopped REC mark j UDATA com ENDLESS disappears ri f ah ah ah hPa 10 11 Setting Recording Interval from Main Unit Button You can make or change recording interval settings from the lt INTERVAL gt button on the front of the TR 73U main unit During recording or while waiting for a programmed recording to start via the provided software there are not settings to be made 1 on lt INTERVAL gt button Press in the lt INTERVAL gt button on the front of the device until the recording interval appears in the display With each pressing of the lt INTERVAL gt button the recording interval time will change Press until the desired setting appears Recording Interval 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60 minutes
19. will appear in the unit s LCD display and recording will automatically stop Endless Mode When the number of recorded readings reaches 8000 the oldest data readings will be overwritten and recording will continue Current Readings Monitoring Display With our exclusive software you cannot only monitor the current measurements at a set interval but can view those measurements in a continually changing graph You can simultaneously display the current measurements and corresponding graphs for the number of units you have connected Adjustment Function By entering the adjustment values beforehand with the provided software it is possible to view and record the adjusted measurement values There are two methods of adjustment adjusting by one point or adjusting by two points Adjustment for differences will be based upon the following simple equation Y aX b X equals the measured value and Y equals the value after adjustment Package Contents Temperature Humidity Sensor T amp D Recorder for Windows TR 3100 x 1 Software CD ROM x 1 User s Manual Warranty x 1 Software User s Manual x 1 a ee i USB Communication Cable US 15C x 1 AA Alkaline battery x 1 Before Using Important Notes about the Installation Procedure for using this product with USB communication Thank you for choosing T amp D Products In order to use a USB connection to communicate between this product and a PC it is necessary t