Installation Guide

image

Contents

1. 2 is STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL 10 11 12 13 14 19 16 17 MODELS MM 35 MM 50 MM 65 MM 75 and MM 90 MINI MIST SERIES GUIDELINES FOR STEAM ROOMS Walls ceiling and floor must be completely covered with waterproof finish tile marble stone or slate Any smooth surface flooring that is used such as tile or marble should include an anti skid finish to avoid slipping and injury Any exposed plaster plasterboard or sheet rock surface must be well sealed with acommercial quality waterproof sealer urethane or epoxy at least 3 coats Use cement board DO NOT use green board Ceiling should be pitched away from the door 1 1 2 per foot or constructed in a gable configuration to prevent condensation from dripping Built in seat should be slightly pitched to allow for condensation run off Steam room must be completely enclosed with walls door floor and ceiling but should not be vapor proof A slight opening of approximately 1 4 is desired to create movement of the steam A standard glass shower door is sufficient a special door is not necessary Make sure there is a floor drain for condensation run off and cleaning Do not install a fan inside steam room Hot steam rises and will escape through the flapper Windows that are part of the steam room enclosure should be double paned If using lights inside steam room they must be vapor proof A deionizer or inline filter
2. a volt meter test that there is no voltage on power side of the terminal block L1 and L2 e Turn brass screw on 2 1 2 x 3 panel on top of unit to access top of Brass Water Level Sensor Probe e Disconnect red and black wires from top of Brass Water Level Sensor Probe e Carefully unscrew Brass Water Level Sensor Probe e Sand off any calcium build up or debris on sensor tips with very fine sandpaper DO NOT CUT OR TRIM SENSOR WIRES e Apply white teflon tape around thread e Carefully screw Brass Water Level Sensor Probe back in e Reinstall red and black wires to top of Brass Water Level Sensor Probe Turn on main electrical breaker NOTE This maintenance is suggested for any service specialist Iron content in local water will determine the frequency of probe service Start out at least once a month and if the probe is clean and not coated then try every two months etc More frequent servicing of the probe may be needed if the unit is in an extremely hard water area or the water is supplied by a well 13 WARRANTY Steam Whirl Products warranties its products to be free of defects in workmanship and material under normal use and maintenance for a period of 6 years from the date of original purchase Steam Whirl Products liability under this warranty shall be limited to repair or replacement of products that have been determined to be defective in either materials of workmanship by an agent or representative of Steam
3. and L2 and the ground to the ground terminal 2 Install apower disconnect near unit 3 Install Timer F in Plumbing Diagram according to Timer Installation Instructions 2 STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL MINI MIST SERIES WIRING DIAGRAM hz Sm AA o O POWER SUPPLY dV GROUND 2 STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL 2 VE MINI MIST SERIES TIMER INSTALLATION SET TEMP 2 Y a S team Whirl TIMER F in Plumbing Diagram The Mini Mist Digital Timer MUST be installed in the steam room Requires 1 3 8 mounting hole Connect the supplied modular telephone cable H in Plumbing Diagram to the RJ11 jack on the back of the Mini Mist Digital Timer and to the RJ11 jack on the outside of the Mini Mist unit above Wiring Junction Box Press ON button the Mini Mist Digital Timer display window will show the value of 60 minutes Every minute thereafter it will decrease and display the updated amount of time remaining At any time while the Mini Mist Digital Timer displays the time the user may adjust the time remaining anywhere from 1 to 90 minutes by using the up and down a
4. construction of steam rooms may require a larger unit to produce the desired conditions Consult an Architect Designer Contractor or the factory to determine all factors necessary to build a suitable and safe steam room Larger Generators are available Steam Whirl s revolutionary LED self analysis system in the Standard Series generator simplifies installation and monitors for proper electrical and water feed at all times All stainless steel tanks and components Extensive factory testing for all conditions 6 year limited manufacturing warranty Factory assistance provided from blueprint to finished product 3 2 STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL GENERATOR SIZING GUIDE MAXIMUM CUBIC BREAKER WIRE ITEM MODEL FEET KW VOLTS PHASE AMPS SIZE SIZE CAPACITY eza2035 mmas 60 a 20 1 18 20a iawa Do 9 0 240 1 38 soa sawa Mini Mist Series models contain 1 Steam Generator 1 Accessory Kit Probe Maintenance Instructions and Installation Instruction Guide 2 STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL When installing and using this electrical equipment basic safety precautions should always be followed including the following 1 READ AND FOLLOW ALL INSTRUCTIONS 2 WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times 3 WARNING K To reduce the
5. ERATION amp MAINTENANCE MANUAL PLUMBING DIAGRAM Water Supply Line Shutoff Valve As close to unit as possible Steam Outlet Steam Outlet Steamhead STEAM Locate 8 to 12 above floor ROOM E Pressure Relief Valve F Mini Mist Timer Locate 4 to 5 above floor Rae F LED Indicator Window H RJ11 Cable to Timer 1 Wiring Junction Box L1 L2 amp Ground Pigtail F GS GB GG 22233 x D Bench Seat 2 STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL GENERATOR DIAGRAM 17 7 ing LJ i Fitting z a u M Sean Gute Water Supply 1 2 Fitting Line 1 4 e Su EEE y Wiring rane l Junction Box Pressure Relief Valve a 3 4 As 3 1 RJ 12 Jack E 3 Junction LED Indicator 6 Window Water Supply Line 1 4 Copper Line 1 4 NPT Femal Thread Steam Output Line 1 2 Copper Line 1 2 NPT Femal Thread Pressure Relief Valve 3 4 Copper Line 3 4 NPT Female Thread Valve Supplied ELECTRICAL IMPORTANT All wiring should be done by a qualified electrician and must conform to all local and national electrical codes Ak WARNING ELECTRICAL SHOCK HAZARD POWER MUST BE DISCONNECTED AT THE MAIN ELECTRICAL SUPPLY BEFORE MAKING ANY CONNECTIONS 1 Supply wiring should be sized in accordance with the distance voltage and amps of the unit and suitable for 90 C Bring supply wires from Wiring Junction Box in Plumbing Diagram to L1
6. NSTALLATION OPERATION amp MAINTENANCE MANUAL SYSTEM INITIALIZATION STANDARD SERIES ONLY 1 Plug in RJ11 Cable H in Plumbing Diagram to Mini Mist timer at unit and test before installing permanently 1 After all connections are completed make sure power and water are on by verifying the following indicator lights viewable through front panel cutout hole G in Plumbing Diagram e Turn on timer and allow for sufficient time for generator to react e Green light ON verifies electrical power is on G1 e Green light OFF check circuit G2 Red light ON water level is low and tank is filling until water reaches proper level G1 e Red light OFF water level is adequate G2 2 Steam will begin to appear at the steam head 3 The timer control will shut off steam generator when the desired temperature is reached 4 The timer will automatically resume if temperature drops below set point 5 Steam will shut off automatically when time display reaches zero G1 G2 POWER WATE RA 12 2 is STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL MAINTENANCE Ay WARNING ELECTRICAL SHOCK HAZARD POWER MUST BE DISCONNECTED AT THE MAIN ELECTRICAL SUPPLY BEFORE PERFORMING ANY MAINTENANCE 1 The steam generator is designed for unattended operation and requires little maintenance 2 Water Level Sensor Probe maintenance is as follows e Shut off main electrical breaker e Open Wiring Junction Box and with
7. Whirl Products If repair or replacement cannot be made on the premises by such agent or representative then the product should be sent to the service facility Technical Service STEAM WHIRL PRODUCTS 3775 W Teco Ave 5 Las Vegas NV 89118 6827 800 232 7832 Products being sent to the service facility need to have prior approval and an RMA RETURNED MERCHANDISE AUTHORIZATION assigned The products are to be packed in a well padded box include RMA name return address and daytime phone number along with a short description of problems Mail or ship the unit prepaid to the above address If the product is returned for a defect other than in materials or workmanship a reasonable charge will be made for parts labor and shipping This warranty shall be void and or does not cover the following 1 Charges for parts or labor incurred before delivery of product to the address above 2 Any damage or defect caused by the installer service company user or any other person 3 Installation is not in accordance with the installation instructions provided with the product and or installation by a person other than a licensed electrician or plumber 4 Deterioration due to normal wear and tear 5 Misuse accident incorrect operation lack of proper maintenance acts of God 6 Chemical corrosion 7 Alteration of product in any way 8 Exposure to outside weather conditions or temperatures 9 Contact shows evidence of sho
8. al size of the unit and accessibility for plumbing service and Water Level Sensor Probe maintenance must be considered INSTALLATION Place the steam generator in a location heated attic basement vanity closet or under shower bench so that it is ACCESSIBLE and not more than 40 from steam room All steam generators are suitable for operation in ambient not exceeding 60 C 140 F ALL steam generators require maintenance The steam generator should never be located where it is exposed to outside weather conditions or freezing temperatures near flammable materials inside the steam room or where access cannot be gained to Water Level Sensor Probe for maintenance Install in an upright and level position The serial number label should be visible and accessible for service A minimum of 1 of open unobstructed space must be left around the top and sides of the generator to allow for heat dissipation and accessibility for service IN ATTIC IMPORTANT See 1 Above TIMER CONTROL IN CLOSET Behind Shower Wall IN VANTITY sus See 1 Above e bl i TI IN BASEMENT IMPORTANT S
9. ee 1 Above 2 STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL PLUMBING IMPORTANT All plumbing should be done by a qualified plumber and must conform to all local and national plumbing codes Ak WARNING ELECTRICAL SHOCK HAZARD POWER MUST BE DISCONNECTED AT THE MAIN ELECTRICAL SUPPLY BEFORE MAKING ANY CONNECTIONS Use copper or brass fittings only DO NOT use galvanized or black iron DO NOT USE PLUMBERS PUTTY ON ANY WATER CONNECTIONS A union must be installed close to the generator to facilitate easy removal if necessary Tap off any existing water supply line hot or cold with 1 2 copper tubing or 1 2 NPT pipe If hot water line is used temperature should not exceed 160 F The maximum water pressure should not exceed 120 psi Flush at least 1 gallon of water to clear line prior to connecting to the 1 4 compression water inlet fitting A in Plumbing Diagram on generator When tightening this fitting use two wrenches to avoid strain on Water Solenoid Valve inside generator Install a shut off valve B in Plumbing Diagram on the water supply line as close to the generator as possible DO NOT USE A SADDLE VALVE For best results install an inline filter between the shut off valve and generator For best results steam generator should be higher than the steam head If this is not possible steam line must slope 1 4 per foot minimum to steam room Connect 1 2 copper tubing or 1 2 NPT pipe
10. hooked up on incoming water line is helpful in hard corrosive water areas Install the steam generator to hot side of water to reduce heating time unless a water softener is hooked up Water softeners are usually hooked up to hot side Check local utility line voltage and choose appropriate steam generator voltage 208 Volt or 240 Volt Make sure the steam generator is installed in an upright and level position and is in a location that is ACCESSIBLE for Water Level Sensor Probe maintenance Steam generator should never be located where it is exposed to outside weather conditions freezing temperatures near flammable materials or inside the steam room 2 STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL kk CONFIRM THE CORRECT MODEL HAS BEEN SELECTED Multiply the length x width x height of the steam room enclosure A A Cubic Feet If enclosure walls are constructed of glass marble concrete stone B or slate Copy the Figure from box A to box B Cubic Feet Total A and B for total Cubic Feet C C Cubic Feet INCREASE C FOR EACH OF THE FOLLOWING FEATURES OF STEAM ROOM ENCLOSURE Add 15 for an exterior outside wall Add 15 for an extra glass panel in addition to the door Add boxes C through F for total Cubic Feet G Select recommended model from the GENERATOR SIZING GUIDE on Page 3 Cubic Feet Add 15 for each additional foot for rooms over 8 high NA G Certain materials used in the
11. merchantability design or operation of the product or its fitness for any particular use or purpose or the quality of the materials or workmanship in the product or any other representation or warranty beyond the terms of this warranty Steam Whirl Products shall not be liable for the user s incidental or consequential damages User acknowledges that the price of the product would be higher if Steam Whirl Products were liable for consequential or incidental damages Some states do not allow the exclusion or limitation in whole or in part of warranties or the exclusion of consequential or incidental damages therefore the above limitation or exclusions may not be applicable to you Steam Whirl Products warranty obligation shall be discharged upon tender of repair or replacement User s refusal to accept the tender terminates Steam Whirl Products warranty obligation MODEL DESCRIPTION SERIAL Water Sensor Probe Maintenance Schedule 1st Check Suggested 2nd Check 3rd Check LISTED FOR TECHNICAL ASSISTANCE CALL 800 232 7832 E MAIL techsupport steam whirl com es STEAM WHIRL
12. od pressure circulatory system problems or diabetes should consult a physician before using a steambath Persons using medication should consult a physician before using a steambath since some medication may induce drowsiness while other medications may affect heart rate blood pressure and circulation The use of alcohol drugs or medication can greatly increase the risk of hyperthermia Some aroma therapy oils may cause an allergic reaction USE WITH CAUTION The installation of a Steam Diffuser is recommended This device will enable the user to move comfortably around the steam shower and may help prevent burning or scalding Always shut electricity off at the main breaker panel 44 SAVE THESE INSTRUCTIONS 9 2 STEAM WHIRL INSTALLATION OPERATION amp MAINTENANCE MANUAL 1 2 PRE INSTALLATION Verify correct model has been sized for the cubic feet and type of steam room using the GENERATOR SIZING GUIDE on Page 3 Check that the electrical power supply available is adequate for the voltage amps and phase of the generator Ak WARNING ELECTRICAL SHOCK HAZARD 3 All installations and service must be performed by a qualified electrician and or plumber and conform to all local and national codes The generator must be installed and operated according to the instructions Failure to do so will void the warranty and could lead to injury or death due to the live electrical components involved with installation Physic
13. risk of injury The wet surfaces of steam enclosures may be slippery Use care when entering or leaving The steam head steam line plumbing and other components become extremely hot 212 F during operation The steam head and plumbing must be installed in a location so that contact by user cannot occur Insulate plumbing lines for additional protection The steam head is hot Do not touch the steam head and avoid the steam near the steam head After the system is shut down the components will remain hot Do not come into contact with the steam head or components until the system has returned to a normal temperature Prolonged exposure to steam may cause hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effects of hyperthermia include Failure to perceive heat failure to recognize the need to exit the steam room unawareness of impending risk fetal damage in pregnant women physical inability to exit the steam room and unconsciousness Excessive temperatures have ahigh potentialfor causing fetal damage duringthe early months of pregnancy Pregnant or possibly pregnant women should consult a physician regarding correct exposure Obese persons and persons with a history of heart disease low or high blo
14. rrow icons The timer will then count down from the new value each minute as before MPERATURE At any time the user may press the SET TEMPERATURE button The 3 digits LED display will then temporarily change to show the temperature setting While the display is showing the temperature setting either of the up and down arrow icons may be pressed so that the temperature setting can be adjusted Pressing the up and down arrow icons adjusts the temperature setting by one 1 degree increments from 90 to 120 degrees Fahrenheit Repeated pressing of either arrow button or holding one of the buttons down allows the use to change the setting to the desired temperature If there is no further pressing of either button the display will automatically revert back to displaying the current time remaining and the system will bring the steam temperature back to the temperature setting When power is first supplied to the Mini Mist system or after a power interruption the initial temperature setting will be 100 degrees Fahrenheit As long as the line power is not disconnected the temperature setting will remain at the last user adjusted value 3 The Mini Mist will shut off steam when the desired temperature is reached and will automatically resume if temperature drops below the set point 4 Ifthe Mini Mist is operating properly peel liner off the back of the timer foam gasket and adhere to the wall 5 DO NOT staple cables 2 STEAM WHIRL I
15. rt circuiting 10 Damage incurred in transit The user or installer must examine the product immediately on delivery before installation and report any damage to the carrier and the seller 11 Shipping costs to or from warranty service facility unless required by applicable law 12 Repair or replacement of any installation materials including but not limited to tiles marble etc or costs relating to obtaining access for repair removal or reinstallation of the product or a replacement product lt is the responsibility of the user installer or contractor to provide access for service and removal of the product if necessary Steam Whirl Products is not responsible for any costs relating to accessing the product or its removal The dealer distributor and or installer is responsible for knowing the applicable building codes and the dealer and or distributor should notify the installer of same or confirm that the installer is aware of the applicable building codes Building codes vary from location to location and Steam Whirl Products cannot be responsible for knowledge of such codes No other company or person has any authority to make any warranties or representations concerning Steam Whirl Products or the products Accordingly Steam Whirl Products is not responsible for any such warranties or representations Steam Whirl Products has not made and does not make any warranty either expressed or implied about the condition
16. to steam outlet C1 in Plumbing Diagram for left or right side installation or C 2 in Plumbing Diagram for top installation and run to approximately 8 12 off finished floor in shower or just above deck of bathtub on any wall not interfering with user and at least 12 14 away from seat or bench For areas with acrylic or other non heat resistant floors install steam head 20 30 off finished floor in shower DO NOT PLACE A SHUT OFF VALVE ON STEAM OUTLET LINE ONLY ON WATER SUPPLY LINE WARNING DO NOT PLUMB VALLEYS AND DIPS WHERE WATER FROM STEAM CONDENSATION IN THE LINE COULD COLLECT AND CAUSE BLOCKAGE Leave approximately 1 2 of threads protruding from finished wall Place escutcheon on threads and screw on steam head D in Plumbing Diagram Take care not to scratch the steam head with wrench Rotate steam head until open slot is facing down IMPORTANT Steam head must be installed to prevent users from coming into direct contact with the steam head and the steam coming from it While in use the steam head and steam coming directly from it will become hot and can burn An optional Steam Diffuser is recommended for small steam rooms Connect 3 4 copper tubing or NPT pipe to the pressure relief valve E in Plumbing Diagram This item must be installed with a union and plumbed to drain to an approved location DO NOT PLUMB THE PRESSURE RELIEF VALVE LINE TO THE STEAM LINE OR INTO THE STEAM ROOM 2 STEAM WHIRL INSTALLATION OP