1. Connection Status Connected Duration 3 days 05 55 51 Speed 100 0 Mbps Activity Sent Received Packets 44 566 35 712 Properties Close Figure 4 The Local Area Connection Status Dialog UM016301 1003 Configure the Hardware ZDI232ZPAK2ZPK ZiLOG ZPAK II Debug Interface Module Page 5 ZiLOG 3 Inthe Local Area Connection Status dialog box click the Properties button The Local Area Connection Properties dialog box appears Figure 5 Local Area Connection Properties General Authentication Advanced Connect using HP Intel R PRO 100 VE Network Connection This connection uses the following items M SB File and Printer Sharing for Microsoft Networks M HBl QoS Packet Scheduler a Intemet Protocol TCP IP Description Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Figure 5 The Local Area Connection Properties Dialog Configure the Hardware UM016301 1003 ZDI232ZPAK2ZPK ZiLOG ZPAK II Debug Interface Module ZiLOG Page 6 4 Inthe panel labeled This connection uses the following items select the Internet Protocol TCP IP item to highlight it and click the Properties button Figure 5 The Internet Protocol TCP IP Properties dialog box appears Figure 6 Internet Protocol TCP IP P
2. ZDI232ZPAK2ZPK ZPAK II Debug Interface Module ZiLOG UM016301 1003 User Manual Introduction This document describes how to setup and use the ZiLOG ZPAK II Debug Interface Mod ule with your ZiLOG development kit The ZPAK II module enables a development PC running ZDS II to communicate with a ZiLOG development kit It also provides an Ether net interface to the development PC The kit includes e ZPAK II module e DB9 to ID10 serial cable e Keyed 40 conductor ribbon cable e Target Interface Module TIM e User Manual e CD ROM with ZDS II software and additional documentation Installing and Configuring ZPAK II The ZPAK II module features an Ethernet interface and an RS 232 console port Slight modifications to your PC s network configuration may be required for first time use Fol low the steps in this section to install and configure the ZPAK II module See Figures 1 and 2 Ethernet Development PC Hub Development Kit ZPAK II Figure 1 Hardware Setup using an Ethernet Hub ZiLOG Worldwide Headquarters 532 Race Street San Jose CA 95126 Telephone 408 558 8500 Fax 408 558 8300 www zilog com ZDI232ZPAK2ZPK ZiLOG ZPAK II Debug Interface Module ZiLOG Page 2 5 VDC Development PC Development Kit ZPAK II Figure 2 Hardware Setup using a Crossover Ethernet Cable Crossover CAT5 RS 232 1 Set up the target development kit as described in its quick start guide supplied on t
3. page via a browser over an Ethernet connection The other way is via the ZPAK II console port The following steps describe the console port method Note To change the ZPAK II settings from their defaults via a web browser please consult the ZPAK II Debug Interface Tool Product User Guide PUGO0015 The serial port of the PC should already be connected to the console serial port of the ZPAK II Launch HyperTerminal on the PC by navigating from the Start menu to Programs Accessories HyperTerminal or Accessories Communications gt Hyper Terminal depending upon your Windows OS Create a new connection in HyperTerminal by selecting the appropriate COM port in the Connect using field of the Connect To dialog Click OK Note This connection is a direct connection via a COM port not a modem If you select COM1 the COM1 Properties dialog appears Enter the following port settings and click OK Bits per second 57600 Data bits 8 Parity None Stop bits 2 Flow control None Ensure that the connection is in the Connected state by observing the HyperTerminal status bar If not connected select Connect from the Call menu While holding down the z key lowercase on the PC s keyboard use a toothpick or straightened paper clip to press the RESET button on the side of the ZPAK II The RESET button is recessed within the side of the ZPAK II Releasing the z key dis plays a ZPAK II console boot up message in Hyper
4. PK ZiLOG ZPAK II Debug Interface Module J 4 A ZiLOG Page 3 If working in a networked environment set the ZPAK II module IP address and subnet mask to match the existing network setup See Changing ZPAK II Module Settings to Match the PC for instructions Changing the PC s Settings to Match the ZPAK II Module The following instructions are for the MS Windows XP platform If your Windows operat ing system is different please refer to your MS Windows OS online help for details 1 Open the Windows Control Panel and double click the Network and Internet Connections icon The Network Connections dialog box appears Figure 3 s Network Connections BAR File Edit View Favorites Tools Advanced Help ay Q xx amp E pi Search gt gt Folders E S e Network Connections v 8 Go LAN or High Speed Internet Network Tasks E Create a new connection E A GVC REALTEK Ethernet 10 10 View status of this connection Change settings of this connection Other Places Control Panel a My Network Places My Documents My Computer Details Figure 3 The Network Dialog UM016301 1003 Configure the Hardware ZDI232ZPAK2ZPK ZiLOG ZPAK II Debug Interface Module ZiLOG Page 4 2 Inthe panel labeled LAN or High Speed Internet double click the Local Area Connection icon The Local Area Connection Status dialog box appears Figure 4 4 Local Area Connection Status General Support
5. Terminal followed by the ZPAK prompt as shown below ZiLOG TCP IP Software Suite v1 1 Copyright C 2003 ZiLOG Inc All Rights Reserved clock enabled UM016301 1003 Configure the Hardware ZDI232ZPAK2ZPK ZiLOG ZPAK II Debug Interface Module ZiLOG Page 8 created buffer Pool 1524 32 created buffer Pool 4096 8 IP Address 192 168 1 50 IP Subnet 192 168 1 0 255 255 255 0 IP Gateway 192 168 1 254 netstart exiting stack extent 379 2048 ZPAKII version y Copyright 2001 3002 ZiLOG Inc All Rights Reserved ZPAKII Console version 1 5 Type H for help ZPAKII gt gt Note In the example output above x x x denotes the current version of the TCP IP stack software and y y denotes the current version of ZPAK II The console prompt is not case sensitive 7 Atthe ZPAKII prompt enter H and press ENTER The following message should appear ZPAKII gt H H display this Help I change Ipaddress S change ipSubnet mask G change ipGateway P change Portnumber V change dtli Variable count B change dtli Buffer size F load deFault settings C display Current settings A toggle pAssword D toggle Dhcp option W change passWord R Reset zpakii ZPAKII gt 8 Use the I command to change the ZPAK II s IP address to one that is compatible with the PC Use caution to avoid creating a conflicting IP address 9 Use the s command to change the ZPAK Is subnet mask to one that is compatible with th
6. e PC Typically the subnet mask is the same as that of the PC UM016301 1003 Configure the Hardware ZDI232ZPAK2ZPK ZiLOG ZPAK II Debug Interface Module ZiLOG Page 9 gt Note All changes are saved to Flash memory inside the ZPAK II 10 Cycle the power on the ZPAK II for the new settings to take effect The hardware is now configured and ready for application development with the eZ80Acclaim module contained in this kit Compatibility with Microsoft Operating Systems The ZPAK II Debug Interface Module is compatible with the following Microsoft operat ing systems when connected directly to the serial port of the PC e WIN98SE e WINNT e WIN2000 e WINXP UM016301 1003 Compatibility with Microsoft Operating Sys ZDI232ZPAK2ZPK ZiLOG ZPAK II Debug Interface Module ZiLOG Page 10 This publication is subject to replacement by a later edition To determine whether a later edition exists or to request copies of publications contact ZiLOG Worldwide Headquarters 532 Race Street San Jose CA 95126 3432 Telephone 408 558 8500 Fax 408 558 8300 www ZiLOG com Document Disclaimer ZiLOG is a registered trademark of ZiLOG Inc in the United States and in other countries All other products and or service names mentioned herein may be trademarks of the companies with which they are associated 2003 by ZiLOG Inc All rights reserved Information in this publication concerning the devices applications or technolog
7. he CD ROM 2 Connect the Target Interface Module TIM to the ZPAK II module using the keyed 40 conductor ribbon cable 3 Connect the TIM to the ZDI port on the target development board Align pin 1 of the TIM to pin 1 of the development board s ZDI socket 5 If using an Ethernet hub connect an Ethernet patch cable from a free port on the Ethernet hub to the Ethernet port on the ZPAK II module Connect the PC s Ethernet port to the same hub If connecting the development PC directly to the ZPAK II module connect a cross over Ethernet cable from the PC to the ZPAK II module 6 Connect the serial COM port on the PC to the console port on the ZPAK II module via the supplied serial cable and the 10 pin adapter cable You may need to reconfigure the ZPAK II module IP address for your networking environment 7 Connect the 5 VDC power supply to the ZPAK II module Configure the Hardware The default IP address and subnet mask of the ZPAK II module are 192 168 1 50 and 255 255 255 0 respectively To enable communication between the PC and the ZPAK II module you must either change the PC s Ethernet settings to match those of the module or vice versa If using the PC in a non networked configuration set the PC s IP address to 192 168 1 21 and its subnet mask to 255 255 255 0 See Changing the PC s Settings to Match the ZPAK II Module on page 3 for instructions UM016301 1003 Configure the Hardware ZDI232ZPAK2Z
8. roperties General You can get IP settings assigned automatically if your network suppots this capability Otherwise you need to ask your network administrator for the appropriate IP settings Qbtain an IP address automatically Use the following IP address IP address 192 168 1 21 Subnet mask 255 255 255 0 Default gateway Use the following DNS server addresses Prefered DNS server Altemate DNS server Figure 6 The Internet Protocol Properties Dialog Enter values for the IP address and subnet mask to match those shown in Figure 6 Leave any remaining fields blank In this example an IP address of 192 168 1 21 and a subnet mask of 255 255 255 0 are being assigned to the PC These values place the PC on the same network as the ZPAK II unit and do not conflict with the IP address of ZPAK II 6 Click OK and restart the PC The PC is now ready to communicate with the ZPAK II module 8 The default IP address of the ZPAK II module is 192 168 1 50 If this address con flicts with another address on the LAN or if another address is more compatible pro ceed to Changing ZPAK II Module Settings to Match the PC on page 7 UM016301 1003 Configure the Hardware ZDI232ZPAK2ZPK ZiLOG ZPAK II Debug Interface Module ZiLOG Page 7 Changing ZPAK II Module Settings to Match the PC There are two ways to change the ZPAK II module s default settings One method is via the ZPAK II module s embedded web
9. y described is intended to suggest possible uses and may be superseded ZiLOG INC DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION DEVICES OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT ZiLOG ALSO DOES NOT ASSUME LIABILITY FOR INTELLECTUAL PROP ERTY INFRINGEMENT RELATED IN ANY MANNER TO USE OF INFORMATION DEVICES OR TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE Devices sold by ZiLOG Inc are covered by warranty and limitation of liability provisions appearing in the ZiLOG Inc Terms and Conditions of Sale ZiLOG Inc makes no warranty of merchantability or fitness for any purpose Except with the express written approval of ZiLOG use of information devices or technology as critical components of life support systems is not authorized No licenses are con veyed implicitly or otherwise by this document under any intellectual property rights UM016301 1003