FC3000S Microprocessor Control System for Elevator User Manual

image

Contents

1. 3 5 Section 4 Hall call control device 4 1 Floor settings 4 1 4 2 HC VEI HC_LCD1616 HC LCD MI Hall control device 4 3 4 2 1 Appearance and s1Ze 4 3 4 2 2 Introduction of terminals 4 3 4 3 HC VE2 Hall callcontrol device 4 5 4 3 1 Appearance and size 4 5 4 3 2 Introduction of terminals 4 5 4 4 HC VE3 Hall call control device 4 5 4 4 1 Appearance and s1Ze 4 6 4 4 2 Introduction of terminals 4 6 4 5 JPS II Hall Hall call control device 4 8 4 6 JPS III Hall callcontrol device 4 9 4 7 JPS II 04 Car floor display control device 4 10 4 8 JPS III 04 Car floor display control device
2. 4 11 Section 5 System functions 5 1 Major functions of FC3000S elevator control system 5 Section 6 Parameters setting 6 1 Structure of menu 6 1 6 1 1 Main page of menu 6 1 6 1 2 Different levels of menu 6 2 Section 7 Common failures and troubleshooting 7 1 Failure codes and names of their represent 7 1 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 7 2 Detailed introduction of failures 7 2 7 3 Other common failures and brief analysis 7 1 Section 8 Warnings at adjustment 8 1 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Section one Brief introduction of the system 1 1 System components The design of FC3000S elevator control system is based on the concept of distributive control with the whole system composed of main control device car control device and internal hall call display control device external hall callcontrol device also used for
3. J1 is input terminal for power and CAN BUS DC24V4 DC24V Power 24VDC 80mA 10 DC24V DC24V Power CANL CAN BUS L SVDC 80mA 10 CANH CAN BUS H J2 1s input port for key and fire signals UP is upwards button and its indicator light DOWN is downwards button and its indicator light 4 5 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 4 4 HC VE3 hall call control device 128 X64 graphic LCD Blue background white character display indicating the floor running direction and state of the elevator 4 4 1 Appearance and size Size 180X70 Installation size 170X60 mm TYPE FC5000 HC VES SN EBENEN aoe ue HH EM ull m ANE yw Dl ee I FTT L ILLI 35 MECIICA LI Ld C F TE 0 SO 50 98 i6 204 nAnNAnnAnnnnnelL E g LLL JL ILIL IL TL JL JL JL LJ z ri TW y di E r a rmnmnmnmnnnmnnmnnmnnnmnnmn LL IL JL IE JL TL JE IE JE JE IE igg J Omm fia EEG a 280 Y a n di ji T Pat E T e m Z ch m mln F zt E A A dd FAO 40 Hmm YY UUJ si LILLIAN 180mm 4 4 2 Terminal introduction 4 4 2 1 Jl UP DN J2 terminals F24V CANLCANH quer Ilong peura J1 is input terminal for powerand CAN BUS DC24V DC24V Power 24VDC 80mA 10 DC24V DC24V Power CANL CAN BUS L SVDC 80mA 10 CANH CAN BUS H J2 1s input port for key and fire signals UP is upward
4. FC3000S Microprocessor Control System for Elevator Ls kaaa WN se ce Fe eee LE fs NE I E t i mam nm 7 E m EE Mm m m E my gt a uM F UE v Ff L ii 1977 P locr regi a 08606666 MU Fr 0 03 O37 037037 037 007 00070 0030 TRELERSE L e s LJ E e ALAN YA CLASE LII m amp i FeseTTYTIS Es Picture 10 hall call control device HC LCD1616 Displaying side 1 4 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Picture 11 hall call control device HC LCD1616 Components side TILTI E EDI RO FIBA F mm E J 1 oum T y i WWW Wm la m mw as es e Wa m hs e y AR MAME ME LIFT x TYPE ME HC LCO MI HESS C Picture 13 Hall call control device HC LCD MI Components side 1 5 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator we HA z fixo Er vs 9 hat Tha A Oe ee et A vr orm Picture 15 Car floor display control device JPS III 04 ee e P c ev e e e e e e e es e L4 Picture 16 Hall call control device JPS III 1 6 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Picture 17 Car floor display all control device JPS II 04 Zhuhai Alp
5. DC24V Power 2AVDC 130mA 10 DC24V DC24V Power Lus om eat comestng 0000 CANH CANBUSL 5VDC 80mA 10 CANL CAN BUSH There are 16 4 pin sockets in the car control board for the input and output of functions and internal selection They are defined as below 1 OPI Boor open buton and indicator gh cur Poor sose huron air git a a Door los ton dnc ie s a4 Brt0or 3 internal choice and indicator ight 9 AS Br0oored internal choice and indicator ight 4PIN terminal connect to button call button open amp close door button Note B Floor is the lowest landing floor and it is set by main board menu Its value can be anywhere from B8 64 923 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator See the circuit diagram of every 4 pin socket on the right part of picture below two upper terminals are connected to buttons and two lower terminals are connected to indicating lights As to the control device in the car the end marked with A1 A12 is la foot of the terminal Definition of pin on the circuit board from top to bottom they are 4 GND 3 IN 2 COUT 1 DC24V CONI terminal is used for the extension of internal selection button and indictor And detailed introduction will be presented latter CON2 is used for extension function It can be connected to module of voice announcer at arrival CONG terminal is used for extensio
6. FC3000S Microprocessor Control System for Elevator Copyright Declaration FC3000S Microprocessor Control System for Elevator is copyright protected by Hangzhou FreeControl Co Ltd All rights reserved We will try our best to notify our customer if there is amendment of the function software or design of our products However we don t guarantee that our customer will be informed Please pay attention to the version and date of the manual you are using and contact us or our agent in time to get the latest version of manual Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Safety Warnings Please confirm at the arrival of the product Don t install the equipment if the control device has been damaged Transportation During transportation the commodity shall be handled with care to avoid the possibility of damaging the control device During transportation please do not touch the components of the control device with hands to avoid damage caused by static electricity During transportation please do not touch the control device with wet hands to avoid the possibility of damaging it Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Installation Notice Please install the system to metal or other incombustible substance to avoid the danger of fire Make sure there is no combust
7. When corresponding circuit breaks and the voltage of input terminal is too high it means the insulation of the circuit does not meet requirements which would impair the running of the elevator Please add contactor transfer to corresponding circuit 279 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Section 3 Control board Extension board in car 3 1 CB VEI control board in car An elevator car can use 4 control boards at most which are used for double door system and persons with disability elevator Define the function of control board through the setting of DIP switch DIP 1 DIP 2 See chart below 299999999999999 signal voltage corresponding to PG A door standard control board in Car A Door Control board vvithout obstacle in car B door standard control board in car B Door Control board vvithout obstacle in car Single standard control board in car single car door elevator 1 2 a b Double standard control board in car single car door elevator c Standard control board in car without obstacle control board in car single car door elevator d Single standard control board in car double car doors elevator e Double standard control board in car double car doors elevator f Double standard control board in car without obstacle double control board in car double car doors elevator 3 1 1 Appearance and size Size of car con
8. the failures occurred before 7 1 Failure code and the failure name it represents See following chart o Manconacioroperation talue PowerofFandew 777 Te E Scraping door lock during running Restore after door lock functions normally Failure of inspection signal circuit Power Power off and restore 0 and Power off and restore EER PG failure Power off and restore 10 Door zone lost during running Restore after door zone is normal EE ES circuit breaks while stopping Restore after safety circuit functions normally E Failure of input port Power off and restore 14 Overtime running time Over time running 0000 Power Power off and restore and Power off and restore M MS circuit breaks while running Restore after safety circuit functions running door closing limit switch failure of door A REOR the failure without stop Door opening failure of door A Restore Restore after normal door opening normal door Restore after normal door opening 19 Door Door closing failure of door A Door closing failure of door A of door A Restore Restore after normal door closing normal door Restore after normal door closing Short connection of door lock Restore after normal door opening EHLLLEN LN Short connection of hall door lock Restore after normal door opening WA QE 22 Poor contact of door lock Manually adjustment of door lock Poor contact of hall door lock Manually adjustme
9. 24VDC 80mA 10 DC24V DC24V Power CANL CAN BUS L SVDC 80mA 10 CANH CAN BUS H Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Section 5 System function 5 1 Major functions of FC3000S elevator control system 1 Inspection operation mode When the inspection switch in the car or machine room is at inspection position press UPDOWN button and the elevator will run at inspection speed It runs only when the button is pressed Press button incessantly and the elevator will run It will stop when the button is released Similarly when inspecting door opening and closing button function is in the same way 2 Floor memory learning automatically Attention adjustment operator should not leave machine room during elevator auto learning process Attention Before the auto learning make sure the data in the basic parameters are correct and outer circuits are functioning normally The process of auto learning should be performed and ended manually Operation is carried out by menu and it can be stopped anytime in the course of Auto learning If the car is not at the base floor when the auto learningstarts through menu it will go down to the base floor automatically Then the elevator run upwards When it arrives the door zone of top floor it will stop automatically Press ENTER again the auto learning process ends The system will save the learning data after about 10 seconds
10. FC3000S Microprocessor Control System for Elevator 4 7 JPS III Hall call control device 5X7 and 7X11 two LED dot matrix modules indicating floor and running direction It can also display rolling Chinese charactersto tell the passengers state of the elevator running 4 7 1 Appearance and size Size 246X55 Installation size 75 amp 145 X45 mm TYPE MD JPS I 01 SN 4 7 2 Terminal introduction 081 crc a a mau jm sao ma Cl am Se 14V CANL CANH d2 24V CANLCANH LIL L JL L JU FIRE KEY J1 J2 UP DW J1 is input terminal for power and CAN BUS DC24V4 DC24V Power 24VDC 80mA 10 DC24V DC24V Power CANL CAN BUS L SVDC 80mA 10 CANH CAN BUS H J2 1s input port for key and fire signals UP is upwards button and its indicator light DOWN is downwards button and its indicator light Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 4 8 JPS III 04 Car floor display control device 5X7 and 7X11 two dot LED matrix modules indicating floor and running direction It can also display rolling Chinese characters to tell passengers the state of the elevator running 4 8 1 Appearance and size Size 170X119 Installation size 162X105 mm 170 0 mm 162 0mm MD JPS 111 04 SN Fa z i ra E 5 R2 105 0mm 118 0mi 4 8 2 Terminal introduction J1 is input terminal for power and CAN BUS DC24V4 DC24V Power
11. 20 55HZ ibration 1 m s 55 220HZ Please contact us for more information and confirmation before using the equipment in any special environment Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Contents Section 1 Brief introduction of the system 1 1 Components of the system 1 1 1 2 Appearance of each module 1 2 1 3 Structure of the elevator control system 1 8 Section 2 Main control device 2 1 Appearance 2 1 2 2 Introduction of terminals 2 1 Section 3 Control board Extension board in car 3 1CB_VElcontroldeviceboard in car 3 3 1 1 Appearance and Ss1Ze 3 3 1 2 Introduction of terminals 3 2 3 2 CEB VEI Extension board in car 3 4 3 2 1 Appearance and S1Ze 3 4 3 2 2 Introduction of terminals
12. Basic parameter menu Choose the type of door operator 3 Speed segment The number of normal speed segments output number Start valve speed Speed valve value to judge whether the elevator is activated normally 6 2 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S adie 2 Control System for Elevator Inspection Inspection speed Speed value of inspection running value of inspection running BE GL M L sensn AA e heddiw ee vine nein teste Diameter of traction Diameter of traction sheave H sheave Traction machine deceleration ratio of traction machine X traction ratio Speed ratio Encoder RPM Actual pulse value of encoder Frequency division The same with frequency division rate of inverter ratio Highest landing Actual highest floor of the elevator automatically written in after floor auto learning E Lowest landing pu rre Actual lowest HM MR oU floorof the elevator range B8 63 isa Main landing floor ding floor Main landing floor he floor that elevator goes back to while waiting ao a KM B8 64 Elevator lock T O floor that elevator lands after locking range B8 64 mainfloor returning to the main floor at fire range B8 64 6 1 2 2 Control parameter menu mad 3 Monitorfuneion 4 Automatically return Decide whether the automatically main floor returning to main floor function is ON or OFF I Decide whether the anti troublemaking function of the gt Anti tro
13. Elevator 4 XE A With orientation at the moment the door lock closes A FPF EB Arriving at leveling position 6 1 2 5 Input setting menu READY Each input port can be set as effective at H or L When corresponding input is effective the terminal will display 6 When it is set as H If indicator light of corresponding input port is on the signal of this port is effective 6 If indicator light of corresponding input port is off the signal of this port is ineffective When it is set as L If indicator light of corresponding input port is on the signal of this port is ineffective 12 UP LMT If indicator light of corresponding input port is off the NN DN LMT Ss signal of this port is effective a LL The door zone signals as m EE When the elevator 1s at the door zone the door zone signal is effective 19 OL o Circumstance 1 when the elevator is at the door wt Sb j Door zone switch 1s disconnected and FIRE MR indicator light of the DZ port of the main ET beard sort 26 CDOOR In this circumstance DZ input should be set 28 POWER Circumstance 2 when the elevator is at the door zone 29 OD Door zone switch is connected and 30 CDL indicator light of the DZ port of the main board is on 831 SED when the elevator is not at the door zone Door zone switch 1s disconnecte
14. car floor display etc which worked coordinately through communication by CAN BUS This method simplifies the installation process improves stability and facilitates troubleshooting Names and installation position of each control device are listed as below Installation 1 1 Control device Name Type M Note position Main control device Control cabinet in MB VEI machine room Car control device With 12 floors call signal CB VEI Car operation input port Car extension board cabinet With 8 floors call signal CEB VEI input port each 16X 16 LED dot matrix MSN a HC_VE2 dot matrix external hall call control device eraphic High light LCD amp HC_VE3 ue Hall Call box display Car floor display control device l HC_LCD1616 amp 16X 16 LCD dot matrix Car operation segment high light LCD HC LCD MI cabinet display 7X Iland 5X7 LED dot matrix 7X 1land 5X7 LED JPS III I dot matrix 1 2 Appearance of each module JPS II Pr EEN J MH Rick Sass SPs ES EME RR oi a LT F E T u f T WA a UN 1 T3 TA fa ia ia lia Via ds ds da TE EEE 2333 03 23 83 83 84 83 23 84 83 2 484 84 EI EJ 84 4 84 84 84 84 2 2 lol Ey Eo Es Eo Es Eu N Eos Es Es UE YW EE ET pem AM i OP Mi g 7 gp Nic u 1 i 7t Y vw vow y v V b NEN dime LE e P B5 LI me oe gt Sa m M Picture 1 Main control device MB VEI Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC300
15. dismiss this failure The elevator will continue to work normally but the failure 1s recorded Trouble 23 Poor connection of hall door lock At the door zone during the process of door closing after the door is fully closed there is no hall door lock signal Then the hall door lock is regarded as with poor connection and the failure is marked out Opening the door again if the hall door lock signal works normally then main board will dismiss this failure The elevator will continue to work normally but the failure is recorded Trouble 24 door opening limit switch failure of door B While the door operator2 1s closing elevator door and there is door lock signal after the door has been closed If at this time there is still door opening limit switch signal then the main board regards a door opening limit switch failure occurs at door operator 2 Trouble 25 door closing limit switch failure of doorB While the door operator2 is opening elevator door there is no door lock signal after the process has been completed If at this time there is still door closing limit switch signal then the main board regards door operator2 door closing limit switch failure occurs Trouble 26 Door opening failure of door B Door operator2opens the door After the preset timefor door opening there is still door closing operator switch signal the door lock has not been broken and the door is still not full open A door operator2 opening door failure o
16. door earlier if door close button is pressed In the automatic mode when the door is fully open press door close button it will answer immediately and close the door in advance except the first door open after the elevator run stop 12 Door open button to open the door When the elevator is not running and stops at the door zone and the door is still or in the process of closing press door open button it will immediately execute the door opening command 13 Reopen the door at reopen signals When door safety edges of door or screen detector is acting or the door is not closed completely in certain time the door will reopen unconditionally 14 Door open or not close when over loading When over loading the elevator will not close the door or will open the door if it has been closed At the 5 9 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator same time the buzzer for overload will keep buzzing 15 Door open or close only when the button is pressed In inspection mode door open or close only when the button is pressed When the door opening or closing button is pressed the door will open or close the action will stop as soon as the button is released 16 Attendant change the running direction In attendant mode when the elevator has not started running yet the attendant can press UP or DOWN button to change the elevator running direction 17 External call of th
17. 0S Microprocessor Control System for Elevator E a ba mme Perea tare Lili r z q m LM En a E j be pe Fo TE F Gabe im AT FTT m SR mn SEE Hi HETH Wl LTT i ma ll al 1 i E khh id Ed HT Er HE UNENT HN a lll OO BE hi CES Twm TH ET am El HEU H hh ua i i UR RH o ADA un iM tel a Lt C ME EEN EEN IND MI Abitibi 141 hi Tra Ens oo sl Tal corno mn o E i x LIILLILLIIEBE TIT A5 A AT Tm 0 mi c opas eS 8 c N C e TTE 19999992 TYPEFCSOOO CEB VE AO Picture 3 hall call control device CEB_VE1 TIIIIIII HWD AS A PEA A Picture 4 hall call control device HC VEI displaying side Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator ML inii RII Hii LIII 1A44 rs A EI IBSLEPEEE 454444445 32333333 Lr T E 14044141 LLU 1144144 HHHH ai 4144444355 ELELELE IEPREELEL inii HUD i iim pe FC3000 HC VE1 SN MINIMO JM 32332995353 1208039000 ERE EE ET fh I TA BESEN Sean in ar FEEEW J h Ii k TLL 7 ji Bis HE E DA Tm Eg mm iiiiiiid a AA MANM pe Edo r1 0505 TYPE FC3000 HC VE2 SN 5 7 Picture 7 hall call control device HC VE2 Components side Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175
18. Control System for Elevator mes 37 7 meu 1 fr Lem T d A Floor 13 me KAA DS A DT SD SS DT mes f gt a fr f mee 3 fs fi WAA 1 mem TT mes if O KAA mem iT Floor 21 Foor 1 J o d o i For 1J r r Flora o d o og d j d Foor J j d oors A A y e Porn ood o 01 d jo ors o o d 01 d j d Hom f d Jd r o Fooro OO Forst o o d 017017 ors o o d o d j d d j d Fos 0 8 y NOTE 1 There can be 64 floors at most and the setting of DIP switch increases by binary system p p m p pd a pa E p da a a E p 2 VVhen it is used for internal display board UP1 terminal is connected to door open delay button to realize the function of long time door opening action Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 4 20 HC VEI control device The installation sizes of three hall control devices are the same HC VEI use 16X16 LED dot matrix display displaying floor and running direction It can also rolling display Chinese characters HC LCD1616 use 162 16 LCD dot matrix display displaying floor and running direction It can also display rolling Chinese characters HC LCD MI High light LCD se
19. L M nin coe O mio HII 23 L1 D 14 n wu REESE e Lj mm m me ae m u nun nu Ss LL zB ESALZSAL ISAL Ll 46 imm 58 3mm e amp ulli gt Ll E dl bd RE TL IL IPICTLTL T JL l imi li ER d HUU em en L2 eu gif eant sy ganu faa m m m m mn C1 EAE mm US en Ha em nnm J1 is input terminal for power and CAN BUS J2 1s input port for key and fire signals UP is upwards button and its indicator light DOWN is downwards button and its indicator light 4 8 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 4 6 JPS II 04 Car floor display control device 5X7 and 7X11 two dot matrix modules indicating floor and running direction It can also display rolling Chinese characters to tell passengers the state of the elevator running 4 6 1 Appearance and size Size 122X66 Installation size 105X54 mm pp e U2 L1 C7 C8 zm mn m Z A E qu 54 2mm 69 5mm mm mm cs C6 HNV INY AvZ4 ESALZSAL ISAL HO LT ua a mm m m cs TYPE MD JPS 1I 04 SN c ca Beer 4 6 2 Terminal introduction J1 is input terminal for power and CAN BUS DC24V DC24V Power 24VDC 80mA 10 DC24V DC24V Power CANL CAN BUS L SVDC 80mA 10 CANH CAN BUS H 4 9 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175
20. T f vo S el sal Es Pao IH MT TT EY RED ema cor CUB Wa mpa R9 R150 FIS mja Ue R159 RED ct Cl coa CM4 c5 RM C33 C94 C95 C96 OD C l A O wm AI lt e CON3 U29 Ms u30 A D 2 LI m U2 E a E CES PE r a BATT RNB uza a ee e SEE QUIET RIGO TORTH CTF C7B _ LJ ES E Ll C TT Cn Rt LO S E EE aca El LJ LJ cha C70 CH SE ce AA L eu us BY Poe Es n LLJ II 03 L Cos mc mr COM mi csg C59 CRYSTAL n y Llesa 132 OS 23 uM Ne C35 CH CE Ci edd Cin CH Ca CAS Ci Cia Cie CAT CAB 049 Ch Cm O C52 053 CH m A ies de sl spe EEO EU la E El ED EN SS pep pee epe TE EE E SS E E A AA Ti EEES IIA EPI e RSERSIR C31 C32 LIS Sige Em Ee SAT L JE al l at 4 l l pa JL 4 1 1 C24 C25 C C27 C2 E ME AOR EHNA CA RIO C5 RM CE E3207 R33 CB R54 C3 R35 CIO RS3BCHI R37012 R3E CIS RIJ CH RAQCI RAI CIO RATOTF RAS OIG RA ACS RASCZGRAGCZI RA7U22 RABCZSRAS LJ LJ LJ E E ag ITITITITITITITITITITITITITITITITITITITITI PTC Anal LE Pa TVS 1454 TVSE nim LiL LAA E E E DA A DM E LELitLititititititits ap A 1 FF dE dE LE LE LE LE LE LE LE LE LE d LE LE LE LE LE OE Panama lana lal laMe Ma LI da LIA El Llar Els Els O EEES EEUU SER EE SER EE TE m 2 2 Introduction of terminals Available terminals are Jl J2 J3 J4 J5 J6 J7 J8 See picture above for their p
21. T coo H ji a JT ML ros nm mm FTTTTTTTT TTTTTTTTTTTTTTTI CES CWL Riza LLLELLEELIL LL GL S GL GJ Ru RY2 RYS RYS RYS RYS RY7 Ave AD Bg od d TN a as no NS NUNT E Ru iie E ne huo bu El E a Fri to AVES et Jet RIS Ed i e Hu DC24 PE CANL CANH 9 Lj lt 202mm gt 262mm Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 3 1 2 Introduction of terminal J1 terminal input terminal for switch state signal Outer circuit of the input terminal can be constantly on or off bugs calabria I Safety edges for door Input signal turning voltage T Common end of power supply of input signal J2 terminal input terminal for switch state signal Attendant upwards button attendant Rated input orientation button Attendant downwards button Cattendant DC24V 5ma orientation button Common end of power supply of input signal J3 terminal Relay output terminal LX CIE Doorcloserelayl 3A 30V DC 250VACRES J3 5 Door open relay 2 Used in double door ERE E Door close relay 2 Used in double door S ame BELL bell chime COM5 Common end of J3 8 output 372 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator J3 11 COMO Common end of J3 10 output J3 12 Output of overload buzzer J3 13 COM7 Common end of J3 12 output J4 terminal Terminal of Power and CAN BUS Termina DC24V
22. Take off the power switch after about another 10 seconds the elevator can be powered up again During auto learning floor and number of input pulses can be read form the LCD display If the auto learning fails it will quit the process and shows auto learning failed It will also show auto learning succeeds if the process is successfully completed 3 Collective control mode In automation or attendant control mode the elevator will automatically collect the car instruction and hall instruction control the car running cancel the instructions that have been served Passengers at every floor can call the elevator by pressing up or down button 4 Attendant operation mode Through switch in the operation box attendant control operation can be selected Under this mode the elevator has functions as follows A Attendant can change the running direction B Do not automatically close the door the door will close when attendant presses close button C When hall call is registered the internal call signal corresponding the elevator will be shined D cancel wrong selection If a floor has been chosen press the internal call button of this floor again then selection of this floor will be canceled 5 Firemen operation This function can be categorized to two different situations 1 Return back to fire main floor function Description as soon as the fire switch is on the elevator will cancel all call signals slow down and stop at a near
23. YASKAWA COM2 Common end of inverter output signals PULSE Input terminal of pulse signals Voltage Jumping wire to deal with of PULSE terminal must be higher than different input voltage See chart that of COMG terminal Under PULSE input terminal there is a four bits DIP switch Different state of the switch is corresponding to different pulse signal input voltage See chart below Blank represents OFF states DIP 1 DIP 2 DIP 3 DIP 4 Corresponding PG signal EE 2 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator J6 terminal relay output terminal is used for controlling inverter See the drawings for details Definiti Terminal Details Technical index COM4 Common CommonendofEN DN UP of EN DN UP Relay output EN DN Downward or activation signals 3A Upward signal 30V DC 250VACRES COMS Commonendof Vl V2 V3 J6 5 Speed out 1 EG 6 6 118544 out 2 J6T 7 e p out 3 J J6s 8 COM6 Spare terminal J6 9 MAX number of speed is 8 combination of _ r V2 and V3 J7 terminal Relay output terminal Definitio Terminal Details Technical index and note Common end of J7 2 J7 5 output between power and inverter COM7 signals between inverter and motor Common end for OPEN and CLOSE COM8 l signal CLOSE Control signal of door closing COMO At fire state output signal of the state of ele
24. ack Its function corresponds to the tips at the right down corner of the interface The LCD display and the positions of the keys are as follows ai aoe PO A aoe is EB DE 6 1 Structure of the menu 6 1 1 Main page of the menu After the main board is powered up it will show the company name and after 3 seconds it will enter menu main page FC3000_501 Press the UP and DOWN keys to show the content running status of the elevator load the action of signal input port etc FC3000 S01 Single elevator Auto 2 00m S Stop 1 floor V Menu N 000006 times At the main page of the menu press ENTER key into the password interface 6 1 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator FC3000S main board has 2 passwords 1 Password for entering the menu users cannot change the password 00000000 2 Password for changing the parameters this password is required to input when changing the parameters of the elevator EEES The input password 1s not shown and the correct password should be entered at the corresponding position 6 1 2 Different levels of menu Main menu Name of mena 3 Cmwipumar OOOO 3 swm 4 Twemame s mem 6 Setlandingfloor Co mew SSS s eres compensan 9 cwm 9 Bwrpemdd un gaw 12 Frio memory teaming 8 um we EN SS I OO O s mm 6 1 2 1
25. ame with the set for frequency division ration of the inverter Deceleration ratio deceleration ratio of traction machine X traction ratio 2 Before floor memory learning carry out an upwards inspection run Please check the running speed shown on LCD to confirm if it is the same with the running speed for setting If they are different please check the basic parameters And then check the PG signals to the main board The floor memory learning can only be started when the set speed at inspection run is the same with that shown on main board LCD 3 Position of forcing slowdown switches When the speed segments the elevator running at are over 2 two forcing switch are needed at the terminal floors They are defined as below LSI Upwards low speed forcing slowdown switch corresponding to the slowdown distance at low running speed LS2 Upwards high speed forcing slowdown switch corresponding to the slowdown distance at highest running speed LS3 Downwards low speed forcing slowdown switch corresponding to the slowdown distance at low running speed LS4 _ Downwards high speed forcing slowdown switch corresponding to the slowdown distance at highest running speed Before the learning there is no need to care about the position of the forcing switches Only make sure that when the elevator is at door zone of the bottom floor LS3 and door zone signals should both be ON when the elevator is at door zone of the top floor LS1 and door zone si
26. ase 4 del T4 0 65s arrives at leveling and the speed segments output ela 4 is cancelled the system will make BC1 release 5 In the time set by this parameter after BC releases direction and activation is cancelled This time VF stop delay T5 0 30s should be adjusted according to brake electrical system release time to prevent the elevator from sliding back CAE delay cancel MC2 output After the door is open standard time for the elevator delay 1 to remain the state of door opening Door close After the door is open the time for the elevator to nu ene reopen at FL the time set by this parameter after the door PS the door is still not closed it will reopen In the time set by this parameter after the door closes the door lock is connected and the door is 10 Forced door effectively closes but the door closing signal is still close time effective When the door operator system display bouncing back action after it closes extend this time It is used when there is a lot of cargo coming in and ii Door open T1 300s out Ms this det open extension POE and the extension door will automatically close after the time set by this parameter The door can be closed manually The door 1s closed When the elevator waits for this Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator returning to period of time it will automatically return to the set main floor main fl
27. ccurs Trouble 27 Door closing failure of door B Door operator2 closes the door After the preset time for door closing there is no door closing limit switch signal and no door lock signal Then the main board regards that door operator2 closing failure occurs Trouble 28 Not defined yet Trouble 29 Not defined yet Trouble 30 Slowdown failure While running at the speed segment if the elevator gets to levelling position of scheduled floor after deceleration but the main board has not got the speed conformity signal CV Same Then the main board would report this failure Trouble 31 Door zone failure at leveling When the elevator runs normally and gets to the door zone of scheduled landing floor it does not receive door zone signal Then this failure would be reported If there is door zone signal after the elevator stops the elevator can start again normally and then if the elevator stops and still there is no door zone signal it can also restart but at inspection speed to find the door zone If it cannot find door zone after running for two floors the elevator would stop Possible causes too low input port voltage the position of light block board is not right or the photo electronic device of door zone fails 726 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 7 3 Other common failures and brief analysis 1 Inspection operation can t be carried out May be the w
28. closing limit switch signal and no door lock signal Then the main board regards that door operator closing failure occurs Trouble 20 Short connection of car door lock During the process of door opening and after the door is fully open the car door lock does not break The car door lock is regarded as blocked and the failure is marked out The elevator is forbidden from restarting Possible causes Car door is short connected Insulation resistance value of car door lock is too low may cause this failure too Trouble 21 short connection of hall door lock At the door zone while the system is opening the door after the door is fully open and it s time to the preset time during door open process the car door lock breaks but the hall door lock is still connected Then the system regards the hall door lock of local floor is screened It would report this failure and forbid the elevator from restarting again Possible causes are Hall door is short connected or the insulation resistance of hall door lock is too low 7 4 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Trouble 22 poor connection of car door lock During the process of door closing after the door is fully closed there is no car door lock signal Then the car door lock is regarded as with poor connection and the failure is marked out After the door is open again if the door lock signal works normally main board will
29. d and indicator light of the DZ port of the main board is on 32 DIR In this circumstance DZ input should be set as H Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 6 1 2 6 Setting landing floor Floor B8 Landing floorcan only be set after floor memory learning The floors that permits elevator landing are set as ON Floor 2 ON The floors that does not permits elevator landing are set as OFF IE ES 6 1 2 7 Floor Ways of displaying at floors Setting options are 0 1 2 3 4 5 6 7 8 9 A B MA C D E F GAL M P S Tand nothing 6 1 2 8 Leveling compensation Floor B8 upwards Leveling accuracy can be adjusted through menu to get an very exact Floor B8 leveling accuracy downwards Positive and negative of data When the car is higher than the floor the data is positive when the Floorl upwards mm car is lower it is negative Running upwards to floor 1 the elevator is 3mm lower than the BEEN floor Running downwards to floor 1 it is 38mm higher than the floor Then set the parameter like this Set floor 1 upwards 3mm Floor 1 downwards 38mm After this setting the elevator can level correctly If the measurement is inaccurate or the settings of inverter have Floor64 upwards been changed then the leveling of elevator is inaccurate again It can Floor64 be adjusted in this way downwards If running upwards to floor 1 the e
30. e planning drawings for detailed information of the connection of the terminals Section 4 Hall call control device HC_VE1 HC VE2 HC_VE3 HC_LCD1616 HC LCD MI With DC 24V power supply onboard DC5V JR X tJ switch power hall call control device is installed at every floor to collect call signals of each floor and display the running direction and the floor at which the elevator is running at The hall call board at main floor can also collect signals of elevator lock and fire 4 1 Floor setting There is an 8 digit DIP Switch on the hall call board See picture below for setting the function of the call board ON Cwi AAA AAN 12345678 DIP 8 only used for setting the displaying direction of HC VEI dot matrix When DIP is OFF display normally and when DIP 8 is ON the display will be turn around 90 degree The setting of DIP 7 DIP 1 are listed below Blank represents OFF and 1 represents ON Below settings are for external control board mme wewe 1 Umme rom 1 3 1 mme wem 1 3 sme eru 1 1 Lame mer 1 Dame wegen 1 1 Came ero 1 a Dmme mere 1 1 ror 1 LL me SS mes l o Ber o i Her f f pr po 1 O pp poo po pp T1 Her pp poo po 17T31 71 Fors J Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor
31. e separated Twisted pair wire must be used as communication line Distance between twisted pair wire should be 20mm to 30mm If condition allows it would be better to use thetwisted pair wire and the screen layer should be connected to earth If the heavy current wire are parallel laid with the weak current wire commonly seen in cable accompanying the elevator please make sure that the heavy current wire is laid at one side and weak current wire is at the other side and they are separated by earthed line All above these wiring rules must be specified clearly in the plan drawings The usage of every line must be indicated clearly The casing of control cabinet earth end of inverter casing of motor and the cabinet of the car should be connected to earth Hall call box should be connected to earth too or signals transmission may be impaired Wiring should be conducted by qualified professional to avoid electrical shock accidents or damages of the control device Before wiring please make sure that the power is completely switched off to avoid getting electrical shock and damaging the control device When energizing please don t touch any place with electricity to avoid damaging control device or getting electrical shock Please notice the different volt level of different terminals and do not mix them or the control device might be damaged Please fix the terminal bolt with suitable torque or failure might occur Thewire con
32. ere is watch dog protection function on the main control board When CPU fails or the program is functioning abnormally WDT circuit will force the main control device CPU to reset to former status 43 Remember position of elevator after power off If the power cuts off when the elevator is running or standing the main board will save current position and floor of the car When it is powered up again the elevator will use these saved information to avoid errs 44 Count the times of elevator trip The main board can record trip times of the elevator This record will not be lost when the power is off The times of tripshow at the LCD of main board and in the main interface menu 45 Anti block function of the buttons 5 5 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator If any UP or DOWN button of external call board selection buttons or door open close button in the car is blocked the system will identify this problem and the pertinent button will be inactive until it works normally again 46 Suitable for double door system Satisfy the demand for double door elevator control meeting the requirements of elevator door system in Hong Kong 47 Conveniently set the door opening or closing method For double door system door opening and closing method can be set respectively at each floor through menu of main board 48 Display at each floor can be set freely Display of floo
33. est floor without opening the door Then it will go back to fire main floor immediately and open the door This is the most basic fire function which is supported by all version of software 2 Fire service function Description after the fireman switch has been on and the elevator comes back to fire mainfloor it will run in firemen operation mode in this mode the elevator will not answer hall call and only answer one internal instruction at a time The operation of elevator door is as below when the elevator is not at fire main floor the door will not 5 1 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator open when it stops press the door opening button and the door will open If you release the button when the door is not fully open the door will automatically close at once The door will stay at opening status when it is fully open The door also should be closed manually Press the closing button the door will close when it is not fully closed and the closing button is released it will open again Attention This function is effective only when the option of Fire activation in the menu is yes Attention Fire mode s requirements for elevator are very strict for example the fireproofing quality of the door If the elevator is not Fire elevator do not activate this function Our company is not responsible for any of the results caused by this action 6 Special ser
34. f elevator to finish one trip exceeds what is required door zone signals have no changes then main board stops the elevator directly and forbids restarting Trouble 15 Safety circuit breaks during running While the elevator is running if the safety circuit breaks this failure will be reported After the safety circuit recovers the failure is eliminated and the elevator will run normally Trouble 16 door opening limit switch failure of door A While the door operator is closing elevator door and there is door lock signal after the door has been closed If at this time there is still door opening limit switch signal then the main board regards a door opening limit switch failure occurs at door A Trouble 17 door closing limit switch failure of door A While the door operatorl is opening elevator door there is no door lock signal after the process has been completed If at this time there is still Closing door limit switch signal then the main board regards door operator door closing limit switch failure occurs Trouble 18 Door opening failure of door A Door operator opens the door After the time that timer is preset for door opening there is still door closing limit switch signal the door lock has not been break and the door is still not full open A door operator1 opening failure occurs Trouble 19 Door closing failure of door A Door operatorl closes the door After the time timer preset for door closing there is no door
35. gment display steadily displaying floor and running direction 4 2 1 Appearance and size Size 180X70 Installation size 170X60 mm ma a J2 mS bh Flas rh EJ 60mm 7Omm UPI 5 M re on JC de Ed ri up i Ed f uP T1 4 2 2 Terminal introduction EEE Se AAA 5 8 24 CANLC ANH y gt L CL J1 Terminal Input terminal of power and CAN BUS DC24V DC24V Power 24VDC 80mA 10 DC24V DC24V Power CANL CAN BUSL SVDC 80mA 10 CANH CAN BUSH 4 3 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator J2 1s input port for keys and fire switch signals UPI is A door upwards button and its indicator light DWI is A door downwards button and its indicator light UP2 is B door upwards button and its indicator light DW32 is B door downwards button and its indicator light Under normal circumstance UP2 and DVV2 are not used Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 4 4 FC3000S Microprocessor Control System for Elevator 4 3 HC VE2 hall call control device 5X7 and 7X11 two dot matrix modules indicating floor and running direction It can also display rolling Chinese characters to tell the passengers the state of the elevator running 4 3 1 Appearance and size Size 180X52 Installation size 170X42 mm 4 3 2 Terminal introduction Ur aE EE Y YU gt Fr p Ss tZ4V CANLCANH
36. gnals are both be ON The elevator can only finish the learning under this circumstance start floor memory learning of elevator Adjust the slowdown distance the sense of comfort during starting and stopping and the running speed etc If PG failure occurs during the adjustment failure 09 please adjust the running speed 1 2 3 4 in the basic parameter to twice the value of the highest speed If the failure still exists please check PG signal 6 After finishing work mentioned above please pay attention to the work listed below a Position of forcing switches Position of LS1 and LS3 the distance between these two switches and the terminal leveling position should be the same with or a bit larger than the slowdown distance 1 in the menu Position of LS2 and LS4 the distance between these two switches and the terminal leveling position should be the same with or a bit larger than the slowdown distance corresponding to the highest running speed For example if speed segments in the basic parameter are set as 3 then the distance from these two switches to the terminal leveling position should be the same or a bit larger than the slowdown distance3 3 1 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 7 Problems requiring special attention Floor memory learning should be carried out again every time after the adjustment of forcing slowdown switches 8 After finishing t
37. h acts before the door is fully closed or the circuit is different e Disconnection or break of door closing signal line between main control device and door operator device f Disconnection of power of door operator no power for door operator device g Failure of door operator itself h Over loading of elevator 9 Elevator can only run upwards but not downwards Possible causes are Switch of upper limit is OFF or the circuit of upper limit switch breaks 10 Elevator can run only downwards not upwards Possible causes are Switch of down limit 1s off or the circuit of down limit switch breaks Possible causes listed in this chapter are common failures In an actual situation a careful check up and consideration are needed before a judgment is made 1 1 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Section 8 Warnings at adjustment Problems that need special attention during elevator adjustment including the sequence of adjustment action At the initial stage of installation before inspection running first set the effective status of each input port at the input settings of the menu and set the required basic parameters at the basic parameters Pay special attention to the setting of these two parameters Frequency division ratio if the PG signal of the main board comes from the frequency division port of inverter then the value should be the s
38. ha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 1 3 Structure of the elevator control system Inverter Traction machine Door lock and safety circuit 80 120V AC Feedback of elevator speed Remote DC24V Power monitor 2 Community METS HEFHHFF FFF MM NE A SUN ATA x monitor CAN BUS Well signal and function Parallel and input group control CAN BUS communication Hall call at every line Cfour core twisted pair floor shielded cable Hall call at every floor ETETETT Lu TETE j A oo CEA A m i Car expand Control of door board operator and illumination i Elevator lock Status broadcaster switch In the picture CAN BUS is used in the communication between main board and hall call or car community monitor and parallel and group control 1 8 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Section 2 Main control device 2 1 Appearance Appearance and size of main control device MB VEI Size 215X155 terminals not included Installation size 205 X 145 mm anims mes e mens a Ma 8 lei lei lel a8 Mal TES z zg ERE DRE e RT E Le 2 CARRE 18058 088 De ER Rig R83 RIB RIBS J Www TITI nm 3 HMM E d LHH L FL PLI Else A lea tia EI men rl RN FUP nm HIE LLL UIC RY16 RYU Rv12 RYI5 RYT4 LI LL I LLI H icr xw EEEE El E EE
39. he work of to 7 run the elevator at every speed from low to high It is recommended to run the elevator several times at each speed Then check the running speed in the basic parameter and you may discover that speed value include but not limit to VI V2 V3 V4 corresponding to elevator running speed have been changed Main board gains these values of constant speed by the through running the elevator at different running speed Compare these values to the constant speed value shown on the main board to see whether they are the same or not If not follow these procedures a Startthe floor memory learning process again b Adjust the values to the actual running speed Running speed in the basic parameter will affect the PG failure judgment 9 Special attention Each time after changing the running speed and slowdown distance it is recommended to adjust the position of forcing slowdown switches and start floor memory learning again If only the running speed has been changed the slowdown distance has not been changed there is no need to adjust the position of forcing slowdown switches But it is recommended to start floor memory learning again if you don t want to carry out the Floor memory learning then you should adjust setting of the running speed in the basic parameter menu to the corresponding elevator running speed If the discrepancy is too large the system may report PG failure Please see failure09 PG failure for more informat
40. hen the elevator arrives at floor 1 open B door When the elevator arrives at floor 2 open A door first After A EE EN door is closed then open B door LL When the elevator arrives at floor 3 door A and B open and close simultaneously Floor 64 6 1 2 11 Failure records 003 Failure records No 001 Failure 30 2006 03 26 11 36 When a failure occurs the control system will automatically inspect and judge the type of failure and save the information with the time the failure occurs for later inquiry by maintenance personnel It can save 100 records of failure at most Press UP or DOWN to turn over the pages of records of failure history Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 6 1 2 12 Floor memory learning Floor memory learning Start floor memory learning Start Back At this interface Press ENTER Start the elevator begins floor memory learning automatically The interface changes to as follows 6 8 Floor memory learning Learning Floor2 Pulse 00037252 End While floor memory learning the elevator will be sent back to the lowest floor first Then it will run to the top floor The learning process will end automatically The elevator runs at inspection speed during the learning process If failure occurs during the learning press ENTER to end the process There will be corresponding tips if the learning succeeds
41. ible substance nearby to avoid the danger of fire The machine cabinet that install equipment shall meet relative standards Never install the system at any place where there might be water splash Never drop screws spacer plates or other metal objects into the control device Do not put the cover plate or face plate under any pressure to avoid the possibility of damaging the controller control device Absorbing circuit must be added to all inductive load Absorbing circuit must be added to the coil side of all inductive load such as replay contactor brake coil etc Use RC for absorption for ac type the resistance is 100 2 4W and capacitance is 0 1uF Use reverse parallel connection diode for absorbing DC type DC brake circuit with comparatively larger current can use commute bridge rectifier to replace diode Earth connection of screened wire of rotating encoder is very important Make sure that screened wire is used and one of the ends is earthed Some encoder with poor anti jamming ability will affect the sense of comfort and cause noise of the motor or even render the elevator unable to work normally As to well cable and traveling cable please pay attention to that the heavy current wire including power supply for door operator safety circuit door feedback circuit illumination circuit etc and weak current wire including communication line DCOV DC 24V terminal landing forced deceleration switch terminal limits switch etc ar
42. ing position during well floor memory learning and it does not receive door zone signals the main board will regard a door zone signals failure occurs It will report the failure If it can receive door zone signal again the failure will be eliminated Possible cause too low input voltage the position of light block board is not right or the door photo electronic device fails 1 3 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Trouble 11 Break of safety circuit while stopping When the elevator is stopping if the safety circuit breaks the elevator will report this failure After the safety circuit recovers and the failure is eliminated the elevator can run normally again Trouble 12 Not defined yet Trouble 13 I O terminal failure When two signals are effective at the same time which is impossible in normal situation for example upper or lower limits signals received at the same time or upper and lower emergency slowdown signals received at the same time then the main board will regard that a failure occurs at the IO terminal It will mark the failure out stop the elevator and forbid restarting After the failure is eliminated the elevator will continue to run normally again Possible cause Outer switch fails wrong setting of control device parameters too low about input voltage Trouble 14 Overtime running When the elevator is running normally if the time o
43. ion 10 Why the distance between forcing slowdown switches and the terminal leveling position should be the same with or a bit larger than the corresponding slowdown distance in the menu The slowdown distance set in the menu is the distance required for the elevator to slow down normally at each speed after adjustment The consistence of the forcing slowdown distance with corresponding slowdown distance ensures that in the circumstance of floors mix up caused by various reason or wrong well signal the elevator would decelerate normally and stop at the door zone at the terminal floors If the forcing slowdown distance is smaller than the set slowdown distance in the menu then it may bump into the top or bottom if the elevator runs abnormally If the forcing slowdown distance is much larger than the slowdown distance in the menu then it may take too much time for the elevator to get to the terminal floors because the slowdown distance 1s too long 8 2 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175
44. iring is wrong or the input setting at the menu is not consistent with the outer switches that are actually used 2 Fast run can t be carried out after floor memory learning Possible causes a floor memory learning has not been carried out strictly according to the steps introduced in previous chapters b Door zone switch failure Maybe the door zone switch failed to act wrong wiring or the setting of high or low level effective for door zone signal switch option in the menu is wrong c PG failure The main board has not received pulse signal Causes may be poor connection of pulse signal creended wire break of signal wire or damage of PG 3 Communication failure No display or no call or command can be registered Possible causes may be a Inappropriate connection of four communication lines or one of them breaks b Terminal resistance is poorly connected Make sure that in the circumstance of power off resistance between CANH and CANL should be from 60 to 70 Q and its value is steady c Incorrectly or reverse connection of the four lines 24V 24V CANH CANL Make sure that in the circumstance of power on no matter in the control cabinet operation box or calling box the voltage between 24V and 24V should be around 24V Voltage between CANH and CANL should be between 40 05 V 0 2V 4 Once in a while serial communication breaks or fails and the floor display is abnormal Possible causes are a _ The earth connec
45. is floor can decide the direction of the elevator when it has no direction When the elevator stops at a certain floor without direction External call of this floor can decide the direction of the elevator 18 Farthest call decide the direction of the elevator The elevator answers the farthest external call slows down and stops Then the running direction of the elevator 1s consistent with the direction of external call until the door close even there is no other instructions Before the door closes the direction of elevator is determined by the farthest external call The time from the elevator stopping to the door is closed is called pre direction time 19 Cancel wrong call signal in the car In attendant fire or special mode if passenger presses some button to register and then find that it is not the target floor he wants to go he can press the same button again and the selection will be canceled Attention If internal call signals elimination in the control parameter is selected as YES this function will be also activated in the automatic run mode 20 Automatically cancel signals in the car when changing running direction When the elevator is changing direction at the terminal floors it will cancel all call instructions in the car 21 Direct running for full loading In automation mode when overload the elevator will answer internal calls only ignoring external calls 22 Attendant button for direct running without a
46. iscrepancy of leveling within 100 mm occurs at certain floor it can be remedied by setting leveling compensation through the menu to ensure a precise leveling For example a building of five floors if discrepancy of going up 5 floor is 3 50mm i e the car is 50mm higher and the discrepancy of going down 5 floor is 30mmdi e the car is 30mm lower then in the menu up compensation value for 5 floor is set as 50mm 5 floor down compensation value is set as 30mm 27 Set service floor freely Through LCD operator you can set which floors to stop and which floors to pass by freely 28 Floor display of elevator running status Indicator in the car or hall will display running status of the elevator such as inspection fire failure or special mode etc 29 rolling display of running direction in Chinese characters or dot matrix Dot matrix display is used both in the car and hall Its characteristics are plenty of characters and symbols vivid display and elegant style of font 30 Record failure history The system can record 100 failures code that occurred recently including time and failure code 31 Verify floor position signal automatically Every time the elevator gets to terminal landing floor the system will automatically verify signals of floor position 32 Fire emergency return travel When fire switch 1s on the elevator will cancel all internal or external instructions and go back to fire main floor directly 33 Fi
47. levator is 2mm higher than the floor and running downwards it is 5mm lower than the floor Then add this measurement valve to the number set before then the result is the number to be set Set Floor 1 upwards 3 2 1mm Floor 1 downwards 38 5 33mm Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 6 1 2 9 Call setting Status and Floor Note setting Floor B8 If there is internal choice and hall call signal for correspondence floor then it will display ON otherwise display OFF When the floor where the cursor is pointing to shows OFF press ENTER key and it will change to ON Then main board call answering signal will be activated and the elevator will answer the signal This method is called main board call Use of main board call During the adjustment and testing Set the elevator as exclusive usage through the control parameters in the main board menu Call the elevator through the main board and the elevator won t have Floor 64 to open the door when it stops By this way adjustment and testing process can be performed more efficiently since there 1s less disturbance 6 1 2 10 Door open method Door open Floor Note method FloorB8 B8 A Door open method can be set independently at each floor A For example the setting at the left Florl B When the elevator arrives at floor B8 open A door W
48. n function and can be connected to LCD display in the car Wiring plan OPI CLI OP2 CL2 Al A2 A3 A4 AS A6 A7 AS A9 AIO All AI2 N N O AR N Jo Wiring plan 3 2 CEB VEI Extension board in the car Car Control device can control 12 floors without extension board Car Internal instruction can be added by extension board if the floors is more than 12 One extension board can add 8 internal choices to the control panel and 7 extension boards can be connected to control panel in the car at most The signals of extended internal choices are ordinarily added according to the sequence of extension board 3 2 1 Appearance and size Size 97mmX58mm Installation size 87mmX48mm 374 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator TYPE FC3000 CEB VET SN ME E ed liri eee ees lirl eee iri Er 12 ere mb ar Cl C C3 C4 C5 8 C7 CB ve se ESTE FESUR LI LI L O O L LI LI Di D2 Dj 0 05 Deo 0704 IE SHE DESTRA ENEE EA S EE S NES PED DE Dus ND E LOL JL IL IL dl Ri R2 R5 R4 R5 R6 R7 R8 C9R9 R1OR11 R17 CON2 OUT O O Si gt TWTT LI LLLI R13 R14 R15 R16 C22 09 H R22R23R24 R25 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 3 2 2 Terminal introduction a J1 J8 is corresponding to internal call signals in 8 floors Please se
49. n terminal Electricity index J4 1 GND Ground of Power 5VDC S0mA 10 CANIL CANI BUS L CANIH CANI BUSH CAN2L CAN2 BUSL GND Input signal turning voltage DC18 5V ar GNb Gromd orPower Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 2 5d FC3000S Microprocessor Control System for Elevator CANI is used to connect modules in the well CAN2 is used for parallel and group control main board in this system supports group control function Single elevator mode is a special mode for group control CANG is used for remote monitor and community monitor There are 3 jumper terminals JC1 JC2 JC3 above J4 terminal corresponding to CANI CAN2 CAN3 communication ports respectively They are jumping terminals for CAN BUS terminal resistance 120 Q When the terminal is the farthest end of CAN BUS short connect this jumping terminal and the resistance 1s conducted CAN BUS only add resistance to the farthest two ends Therefore resistance between CANH CANL shall be about 609 J5 terminal Feedback signals and input pulse signals terminals of inverter Termin Definitio Details Technical index a n FAULT Output signal of inverter failure Output signal of conformability of I J52 V SAME Rated input DC24V 5mA speed of inverter l l Maximum input DC48V 10mA Output signal of inverter running or l l J5 3 RUN Input signal turning voltage brake DC18 5V READY Zero speed signal for
50. nected to impulse port should be screened or failure might occur Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Operation control device Notice Installation must be conducted by qualified professional personnel to avoid any accident or damaging the control device Do not operate the control device with wet hands or the control device it might be damaged and electric shock might occur Plugging in or out the plug in parts of the control device should be performed when the power supply is switched off to avoid damaging the control device or getting hurts The work of changing parts should be performed by professionals and bits of wire or metal objects are forbidden to be left in the machine to avoid the possibilities of damaging the control device getting electrical shock or fire Parameter setting must be changed if the control device has been changed The resistance between CANH and CANL shall be around 609 after all the wiring has been finished or the elevator might not be able to work steadily Environment requirements Notice Ambient 0 40 C temperature Relative 5 95 No fog Humidity No direct sunlight dust erosive gas oil fog steam and drops of water etc Environment Avoid salty environments No dramatic temperature drop which might cause fog Less than 1000 meters Mos Vibration range Less than 3mm 2 9HZ 9 8m s 9 20HZ 2 m s
51. nswering hall call In attendant mode before the elevator slows down if direct run button has been pressed then during this trip it will answer internal calls only ignoring external calls 23 Bell chime During the slowdown and leveling process the bell chime on the top or bottom of the car will ring to remind the passengers inside or those waiting outside that the elevator is leveling 24 Automatically switch off illumination and fans during waiting If there is no instructions in a certain period of time set by menu illumination and fans will be switched off As soon as the elevator receives instruction they will be switched on and put to use need to add relay Attention time can be set through the 13th option illumination off delay in the car in time parameter menu 973 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC30008 Microprocessor Control System for Elevator 25 Automatically return to main floor In automation mode when the function of automatically return to main landing is effective the elevator will return to landing floor if there is no demand or external call registration in a certain period of time set by menu Attention this function is activated when the 4th option of the control parameter menu automatically return to main floor is set as YES Attention the time is set by the 12th option of time parameter menu time of returning to main floor 26 Adjustment of leveling accuracy If d
52. nt of door lock j door opening limit switch failure of door B Report the failure without stop running Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Methods to deal with it 7 1 door closing limit switch failure of door B Report the failure without stop running Door opening failure of door B Restore Restore after normal door opening normal door Restore after normal door opening Door closing failure of door B Restore after normal door closing Se failure at EXE Report the failure without stop Restore after door zone is normal position 7 2 Detailed introduction of Trouble Here we explain the possible course of each failure There maybe one or multiple reasons for a single failure Now we explain possible reasons that may result in the failure but the real reasons causing the failures should be determined by inspection personnel basing on analysis of the situation on site Trouble_00 Main contactor operates failure Two seconds after main board sending out the demanding signal for main contactor to operate if it has not received feedback signals indicating that main contactor operates then the system regards failure of main contactor operate occurs and it will record the failure cancel all output control demand and stop the elevators Possible causes coil circuit of main contactor or feedback circuit breaks input voltage is too low main contac
53. oor mE The door 1s closed When the elevator waits for this Illumination j T13 150s period of time the illumination in the car will be delay in car l switched off Maximum ES MU HYN running time This is the period of time during which inverter is without electricity after the safety circuit breaks and I the inverter fails Some inverter cannot restore VF restoring effectively if the time without electricity is too short ime This time is the time the system keeps the elevator wait after the inverter is powered on to give the inverter enough time to be powered up After BC2 and BC1 operates when the time set by this parameter is due and feedback signal BR FB of BC2 release brake contactor opening is effective the system will delay make BC2 release and the resistance of brake circuit will be short connected After BCI releases this delay is activated When it is due the main board will judge whether the action of Brake contactor releasing is completed Brake contactor o If BR FB is effective it means brake contactor fails release delay E The system will report failure This time should be adjusted according to the mechanical delay of brake contactor release Time schedule of output signals mi ik S Be e MG UP EN DN V1 V2 V3 BU1 BG T1 T4 li T3 T2 116 T6 T17 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 6 5 FC3000S Microprocessor Control System for
54. or fails Pulse is the data got from the lowest floor After the learning ends the data is all the pulse data got from bottom floor to the top floor 6 1 2 13 Language There are Chinese and English menu Use this option to select the language Chinese or English 6 1 2 14 About the system 6 1 2 15 System time Through this setting the system time can be adjusted System time will be utilized while recording failures When the system is powered off the system clock is maintained by batteries If the batteries voltage 1s low the time will be incorrect So please change the batteries in time The standard life span of battery is two years The battery has certain shelf life Our warranty of battery is one year after leaving the factory 6 9 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Section 7 Common failures and methods to deal with them FC3000S system is able to automatically judge whether the system failed or not If there is a failure it will automatically record and save the failure code for latter reference by maintenance personnel Understanding the meaning of these failures and knowing how to deal with them is very helpful for adjustment on site FC3000S system will record 100 failures that occur recently If the records are full then new records will replace old ones Note when a failure occurs the code of failure will show at main menu for the convenience of checking
55. ositions require that from left to right terminals are numbered in sequence For example Jl terminal from left to right they are J1 1 J1 2 J1 5 and the rest are numbered in the same Way J1 terminal Power input terminal Lu e Cp Esa Power a Input voltage DC24V 17 5 Earth connecting J1 3 PG terminal LO 0 Pei Power input 2 1 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator J2 J3 terminal Input terminals of switch signals Outer circuit of the input terminal can be constantly on or off Common signal end of input J2 1 COMI I I I terminal of switch signals Feedback signals of main J2 2 MC FB I control device Rated input voltage Feedback signals of brake a AU J2 bC FD Maximum input voltage contactor DC48V 10mA Inspection signal l When input signal of INSI and INS2 are When input signals are simultaneously Up forcing slowdown switch 1 effective when they should not be report J2 11 ILS signal Nearest toterminal failure 13 landing Up forcing slowdown switch 2 J3 1 ALS signal Down forcing slowdown switch 1 13 2 3LS Nearest toterminal landing Down forcing slowdown switch 2 J3 3 4LS signal Load signal can be connected to main board or control board in car But if corresponding setting in the menu is L the terminal that is not in use neue be short connected to common em J4 Terminal CAN BUS communicatio
56. ossible cause Connection of door lock is not good false connection of door lock circuit or door vane scraps door lock etc Trouble 08 inspection signal circuit failure According to standard 14 1 2 3 and 14 1 2 1 1 b elevator inspection operation can be carried out by the methods of safety circuit Safety circuit is based on redundant design with at lest two return circuits are used disregarding the possibility of simultaneous failure of these two circuits When the first failure occurs the main board should stop the elevator So two lines of examination signal are connected to the main board When they are inconsistent it means something is wrong in either circuit Then the main board will mark this failure and stops the elevator Possible cause one of the two lines of inspection signals is broken or the connection is not good input voltage is too low or one of the two inspection loops of the control device is damaged Trouble 09 PG failure After the elevator starts normally if during the running there is no pulse signals received then it is regarded that PG failure occurs The elevator would run at inspection speed instead and slowdown and stop at door zone It is forbidden to run again Possible cause feedback line of pulse signal is broken or the connection is not good or the dial switch of main board is set at the wrong position Trouble 10 Door zone failure When The elevator is in fast running and if it is at the level
57. remen operation Exclusive status for firemen This function is for fire elevator only Activation of this function is forbidden if the elevator is not special fire elevator 34 Anti troublemaking when light loading When the elevator is light loading and there are more than three internal calls have been registered it will cancel all internal instructions Attention to activate this function set the 5th option of the control parameter menu anti troublemaking as YES 0 4 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 35 Elevator overtravel protection If the elevator can t slow down normally and cannot stop after it arrives at the predeterminec floor then the elevator will jog to the next floor and stop 36 Speed monitor at terminal landings At the terminal landing floor the system will automatically control the speed to avoid rushing the roof or bumping to the pit 37 Inspection and protection of the main contactor and brake contactor The system will inspect whether the main contactor and brake contactor is functioning reliably If the status of the contacting point and coil is different it will stop all the function of the car until the main board is powered up again and repositioned 38 Protection against failure of inverter When system detects failure of inverter it will take action to protect against it The elevator will stop running and at the same
58. rouble 05 Inverter starting failure Main board has sent out signals to inverter however it does not receives RUN feedback signals from inverter Then it regards the inverter starting failure occurs and it will stop the elevator and try to start again If the elevator would not start again 8 times continuously it will stop running Possible causes RUN signal failure of inverter too low about input voltage or break of the controlling line from main board to inverter Trouble 06 Speed lost during running The elevator is running at a certain speed however through calculation based on basic parameters and PG feedback pulse the main board figures out that the speed is comparatively slow So it regards a failure of speed lost occurs and identify the failure The elevator would then run at inspection speed and the main board will slow the elevator down until it stops at the door zone and forbid it from restarting Possible causes break of pulse signal line from inverter to main board wrong wiring of feedback port of pulse signal motor does not work or inappropriate setting of basic parameters too fast of the start or stop speed Trouble 07 Scraping door lock during running If the elevator scrapes door lock during running the main board will notice it and stop the elevator After the door lock circuit is closed again the failure will be eliminate The elevator will work normally again but the failure records will remember the failure P
59. rs can be set at will through menu For example display content at each floor can be set freely and conveniently It can run through 4 13 and 18 floor without indicating the floor Underground floor can be shown as B1 B2 49 High light LCD display panel in the car Optional gt Optional high light LCD display panel in the car enhancing the appearance of the whole elevator 50 Voice announcement at arrival Optional Car control board can be connected with a voice announcer at arrival optional If the system is equipped with this function voice announcer will announce the arriving floor every time when it is leveling Every time before the door closes voice announcer will announce the direction it is going etc 976 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator Section 6 Parameter setting FC3000S elevator control system provides mighty and convenient setting parameters function Through LCD display module and 6 keys users can easily set parameters concerning elevator running carry out floor memory learning check the failure history record etc The system adopts hierarchy menu The LCD display is 128X64 dot matrix which can display Chinese character English and numbers The six keys are UP DOWN LEFT RIGHT ENTER RETURN ENTER is a key with multiple function Its function corresponds to the tips at the left down corner of the interface RETURN is the key for going b
60. s button and its indicator light DN is downwards button and its indicator light 4 6 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 4 4 2 2 J3 terminal When DIP switch DIP 5 DIP 7 are ON and the rest are OFF J3 terminal is input terminal for BCD code which is used in paralleled elevators Co rd Du Ce Lr Fa HA PF RS FE E EG mnanaa Jz LLIT Te m E J3 UP_L Upwards indicator light output port of OC door J3 DN L Downwards indicator light output port of OC door J3 DC24V J3 12 Fire signal input port J3 11 Maintenance Inspection signal input port J3 10 Downwards signal input port J3 9 Upwards signal input port J3 57 J3 8 input port for tens digit display J3 1 J3 4 input port for units digit display 13 8 13 77 13 6 13 5 Display 334 33 2 13 2 13 1 Display NOTE 1 represents connection to DC 24V blank represents opening outer circuit Signal voltage range of input port DC12 30V Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 4 5 JPS II Hall callcontrol device 5X7 and 7X11 two dot LED matrix modules indicating floor and running direction It can also display rolling Chinese characters to tell passengers the state of the elevator running 4 5 1 Appearance and size Size 168X58 Installation size 160X46 mm 168 0mm 160 0mm n TYPE MD JPS II 01 SN Pa O
61. time the main board will try to reset inverter If the inverter has been reset and works normally again then the elevator will continue to run normally 39 Group control mode Group control means centralized control of several elevators The system is capable of group controlling for 2 to 8 elevators In the group control system several elevators work coordinately to answer the hall call in the fastest speed and most efficient method reducing the time passengers wait and the energyspend 40 Lock the elevator In automation operation mode if the elevator lock switch is off then the elevator will cancel all hall calling instructions It will still work normally and only execute demands in the car until there is no demand anymore Then it will go back to main floor After the door open the illumination electric fans will be switch off The door opening light will turn on 10 seconds of detention latter the door will shut automatically and the elevator stops running then turn off illumination and fans in the car after delaying time to light off Only after the elevator lock switch is reset will the elevator start to work normally again 41 LCD screen shows status speed direction and floor of elevator LCD operation board displays the status speed direction and floor of the elevator Moreover through LCD operation board you can set parameters and checks the record of failures etc 42 Watch dog protection of the main machine Th
62. tion of the whole system is abnormal also check the earth connection of the power b Wiring of communication is not separated with high voltage power line 5 Sudden stop during running Possible causes are a During running the door vane touches hall door lock switch and activate the switch b During running the steel rope is too long after stretching and it hit safety circuit switch of the compensation chain pit such as buffer switch and activate the safety circuit switch 6 Speed lost during running Possible causes are a Screened line is not used as wiring of encoder The signals of encoder are interfered by electromagnetic wave b Metalnetof screened line of encoder is connected with earth line of motor appropriate method is connecting metal net of screenedline with earth line of control device signal Never connect it to the protecting earth line c The quality of the encoder is poor or it is damaged 1 6 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC30008 Microprocessor Control System for Elevator 7 At some floors calling signals can be registered but no elevator answers them Possible cause is settings of DIP switch of floor control device are wrong 8 The door of elevator won t close Possible causes are a Switch or the circuit of switch of safety edges of door fails b External call or internal choice buttons are blocked c Door opening button are blocked d door closing limit switc
63. tor is blocked and cannot operate feedback point of main contactor 1s fiercely interfered or the connection is not good Trouble 01 Main contactor releases failure Two seconds after main board sending out the demand of main contactor release if there is still no feedback signals indicating that main contactor releases then the system regards a failure of main contactor release occur and it will record the failure and stop the elevators Possible causes short connection of circuit of main contactor loop or feedback loop input voltage is too low main contactor is blocked and would not release feedback point of main contactor is fiercely interfered or the connection is not good Trouble 02 Brake contactor operates failure While the elevator is running BC FB does not become ON in scheduled time then this failure will be reported Trouble 03 Brake contactor releases failure While the elevator is running BC FB does not become OFF in scheduled time then this failure will be reported Trouble 04 Inverter failure When the control device receives failure signals from inverter this failure will be reported Phe system will stop the elevators and forbid restarting Main board will cut off the power of inverter and try to restore it If there is still failure after 3 times then the system will forbid restarting Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator T
64. trol device 262X87 Installation size 87X 110 142 mm 110mm gt 142mm ol Lup Dnw man DIR ser DDL cou T sco COM es oe cur des cu Cy secun ODL COLI SED OL FL uF MAN DIR SPE ODL2 COL SED J Ere duu dada Do dll TOU UU On E INO R23 R24 R25 R26 R27 R28 R23 R50 01 02 03 04 05 D6 D7 DB R51 R32 R35 R34 R35 R36 R37 R38 DS DIO DM O12 DIS DIA O15 D16 E E S gt CONI m em S BE ES mue EWE EDR ET L LE LLL 1 pil O O O O E jy qp p a 1 O O O O E LI cc TTTTTTTTYTTTTTIT TTTTYTTTYTTTTTT E FE EE E ETE TET FE TE EE MEE IE 1 e MAMA A LELLLEELEEELITLUU ou LIL IL IL IE TE IE IL I LIL IL TE IE IHE IE IE I e R40 CS RAV CB R42 C7 R43 CH R44 Cd R45C10 R40 ON RAF Ole RAR CTS R49 CT REGCIS RET CO REP CT PSS CTB R54 CR ROBOT aA m PH ous EIN Dui pus DEA en cod po C 030 C3 C32 C33 CM CIS C ce ES al a AE ET EEES UES hota Hrn HH z mmr mT mirii m E ui 1 Bi LI E A u23 22332 S888 uz4 u2 aan u 33 87 E 38 8339992999595 BSZsgS282992892 882 8 E Swi SE IL iau orem CLUSEI aren CLOSD BELL o Daci BUZZER S Ei A ds l EJ LLLIL Ll 2 gal EHE UL ES Es oe Mg x HE LA d 223 a a Rm E y 62 C63 0604 BES 5 8 T UH ezg are NE a merh C u27 ya di aY Uu Los dX mus Yl 1R120052 AMWYN PES 3 3 i vee H 1 R127 R1 RIZ cag RI At R137 LA R141 R14 Rid RA
65. ublemaking j elevator is ON or OFF Fire function Decide whether the fire function running is ON or OFF activation Internal call signal Decide whether the function internal call signal elimination elimination after double clicks is ON or OFF Set the ID number of each elevator must be different when Group elevators ID control MonitorlD ID Main board elevator C to elevator key signal of external call board It will activations be lost after power off 6 3 Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator 6 1 2 3 Slowdown distance menu Slowdown distance 1 Slowdown distance corresponding to running speed 1 Slowdown distance 2 Slowdown distance corresponding to running speed 2 3 Slowdown distance 3 Slowdown distance corresponding to running speed 3 Slowdown distance 4 Slowdown distance corresponding to running speed 4 6 1 2 4 Time parameter menu When there is vibration during door closing set this MC2 operate X 1 del TI 0 00s time parameter to avoid the vibration of MC2 ela 7 contactor The time starts from MC2 operates When RUN BC operate E I I 2 del T2 signal is effective main board will make BC1 to ela operate The time starts from MC2 operates When time is Speed output 3 del T3 up main board will send signal of speed segment to ela l inverter In the time set by this parameter after the elevator BC rele
66. vator when it returns to the fire J7 10 FIRE_R I main floor and open the door J7 11 COMIO Spare terminal Zhuhai Alpha E amp M Co Ltd TEL 86 0756 3326175 FC3000S Microprocessor Control System for Elevator J8 terminal High voltage input signal port Definitio Terminal Details Technical index SAFTY Input port for examination signals of AC or DC 110V 10 1 5mA safety circuit Input signal turning voltage 65V C DOOR Input port for examination signals of Internal inspection resistance 51K 9 car door lock See picture below Input port for examination signals of J8 3 H_COOR hall door lock Input port for examination signal of POWER pc 3 supply COM11 Common Common ends Door lock switch 51K Insulation resistance V K C T 2 4 COMI1 Wiring figure of outer circuit of J8 terminal Special warnings for J8 terminal Do not connect this terminal to AC220V Power or the circuit may be damaged According to relative standards Insulation resistance of control circuit shall not be less than 0 25M 9 The system requirement Insulation resistance of safety and door lock circuit shall not be less than 0 1M 2 When insulation resistance 1s 0 25M 9 after the door lock breaks the voltage of examination input terminal and COM11 is 51 51 250 110 18V When insulation resistance 1s 0 1M 9 after the door lock breaks the voltage of examination input terminal and COMI1 is 51 51 100 110 37V
67. vice mode In this mode the elevator will not answer hall call and the door will not close automatically Only one car internal instruction is answered Other operation methods for special service run are similar to attendant operation 7 Jog to the nearest floor after failure When the elevator gets back to normal status after a failure and the failure is not a safety one it will jog slowly to the nearest floor if there is a car or hall call Attention After the elevator adjustment has been finished do adjust the elevator inspection running speed to 0 3m s otherwise the elevator may not be able to find the door zone because of too fast speed 8 Automatically open door when landing In automation or attendant mode after the elevator slows down and the car stops at a floor it will open the door automatically if it is 1n the door zone 9 Open door when car instruction button of this floor is pressed When the elevator stops in the door zone of certain floor it will open the door when the car instruction button of this floor 1s pressed 10 Door open responding to hall call of the local floor When hall call button of local floor has been pressed and the elevator has no running direction or the running direction is the same with that of hall call the elevator is not full loaded door will open automatically if the elevator is at the door zone and in a stop state If the button will not be released door remains open 11 Close the