Home
Manual
Contents
1. 5 Surge EN61000 4 6 CS EN61000 4 8 EN61000 4 1 1 Safety CE EN60950 1 de IEC60068 2 32 Free fall sein IEC60068 2 27 Shock 9 IEC60068 2 6 Vibration MTBF 668 306 hrs Warranty 5 years Optional
2. Rail reverse the step 1 3 Insert the top of DIN Rail into the track 4 Then lightly push the button of DIN Rail into the track 5 Check the DIN Rail is tightly on the track 6 To remove the industrial switch from the track reverse the steps above Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail Place the wall mount plate on the top amp bottom side of the industrial switch Use the screws to screw the wall mount plate on the industrial switch Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall To remove the wall mount plate reverse the steps above Hardware Installation In this paragraph we will describe how to install the 4 port 10 100TX 2 port 100FX Industrial Switch and the installation points for the attention Data collect server Human Management Interface Enterprise Switch Industrial Switch Industrial Switch Industrial Switch Field Management Programmable Distribute 1 0 i logic controller co em l i Device Server l Field Automatic device Field Automatic device Field Automatic device 15 Installation Steps 1 Unpack the Industrial switch packing 2 Check the DIN Rail is screwed on the Industrial switch If the DIN Rail is not screwed on the Industria
3. I MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling See figures as below for straight through and crossover cable schematic m RJ 45 Pin Assignments Pin Number Assignment 1 TX 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD O Wy N Transmit Data minus TD Receive Data minus RD m Fiber Port Swi tch Router or PG 3 TD 3 RD 6 TD gt 6 RD 1 RD I TD 2 RD 2 TD Straight Through Cable Schematic Switch 3 TD 6 TDs 3 TD 6 TD 1 RD 1 RD 2 RD 2 RD Cross Over Cable Schemat
4. Lantech IES 0204FT 4 port 10 100TX 2 port 100FX Industrial Switch User Manual Rev 1 01 21 Jan 2008 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures m Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver m Connect the equipment into an outlet on a circuit different from that to which the receiver is connected m Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Content FOG Wang gasser ii CE Mark Warning wiccsctecsc3centenssdla
5. ble mounting DIN rail Wall Mounting 4 x 10 100TX 2 x 100FX Industrial Switch can operate in the range of temperature between 20 60 C E model 40 75 C Packing List m 1x 4 port 10 100TX 2 port 100FX Industrial Switch m 1x User manual m 2x Wall Mounting Bracket and Screws Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input Hardware Description In this paragraph we will introduce the Industrial switch s hardware spec port cabling information and wiring installation Front Panel The Front Panel of the 4 port10 100TX 2 port 100FX Industrial Switch is shown as follows Front Panel of the 4 port 10 100TX 2 port 100FX Industrial Switch Top View The top panel of the 4 port 10 100TX 2 port 100FX Industrial Switch is equipped one terminal block connector of two power inputs ra e T a V2 VZ Vit Vi Top Panel of the 4 port 10 100TX 2 port 100FX Industrial Switch Wiring the Power Inputs Please follow the steps below to insert the power wire V2 V2 Vi Vi 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector 2 To tighten the wire clamp screws for preventing the wires to loose Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows belo
6. cally selected and a crossover cable is not required All Ethernet ports have memory buffers that support the store and forward mechanism This assures that data is properly transmitted Dual Power Input To reduce the risk of power failure the 4 10 100TX 2 100FX Industrial Switch provides 9 56 Vpc dual power inputs If there is power failure 4 10 100TX 2 100FX Industrial Switch will automatically switch to the secondary power input Flexible Mounting 4 10 100TX 2 100FX Industrial Switch is extremely compact and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment Operating Temperature The operating temperature of the 4 10 100TX 2 100FX Industrial Switch is between 20 60 C E model 40 75 C you can use the 4 10 100TX 2 100FX Industrial Switch in some of the harshest industrial environments that exist Easy Troubleshooting LED indicators make troubleshooting quick and easy Each 10 100 Base TX port has 2 LEDs that display the link status transmission speed and collision status Also the three power indicators P1 P2 and Fault help you diagnose immediately Features Provides 4 x 10 100TX 2 x 100FX Mbps Ethernet ports TX ports support full half duplex flow control Supports MDI MDI X auto crossover Embedded with a switch controller supports auto negotiation Supports store amp forward transmission Supports redundant 9 56 Vpc power input Provides flexi
7. for Single mode Goanesiors or Multi mode type fiber cable Multi Mode power budget Min 9dB MAX 19dB Single Mode power budget Min 19dB MAX 260B 10Base T 2 pair UTP STP Cat 3 4 5 cable Network Cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m Multi mode 50 125um 62 5 125um Single mode 9 125um Optical Cable Available distance 2km Multi mode 30km Single mode Wavelength 1310nm Multi mode Single mode Protocol CSMA CD DIP Switch DIP Switch 1 Enable Disable Power Fault alarm DIP Switch 2 Enable Disable Power Fault alarm Per port Link Activity Green Full duplex Collision LED Amber Per unit Power 1 Green Power 2 Green Fault Amber Reserve polarity Present protection Overload current Present protection 9 56VDC 12 36 VAC Redundant power with Power Supply polarity reverse protect function and removable terminal block Power 7 Watts Consumption operating 5 95 Non condensing Humidity Operating 20 C 60 C 4 F 140 F Standard model Temperature 40 C 75 C 40 F 167 F E model Sels 40 C 85 C 40 F 185 F emperature Case Metal case IP 30 Dimension 26 1mm W x 94 9mm D x 144 3mm H Weight 382 g Installation DIN Rail and Wall Mount Design FCC Part 15 CISPR EN55022 class A EN61000 4 2 ESD EN61000 4 3 RS PU EN EN61000 4 4 EFT EN61000 4
8. hielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Q Category 3 4 or 5 cable for 10Mbps connections or 100Q Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet m Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions m F the power indicator does not light on when the power cord is plugged in you may have a problem with power cord Then check for loose power connections power losses or surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance m If the LED indicators are normal with the correctly connected cables and the packets still cannot transmit please check your system s Ethernet devices configuration or status Technical Specification The technical specifications of the Industrial Switch are listed as follows Hardware Specification IEEE Standards IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX and 100Base FX Fast Ethernet IEEE802 3x Flow Control Transfer Rate 14 880pps for Ethernet port 148 800pps for Fast Ethernet port Mac Address 2K MAC address table 10 100TX 4 x RJ 45 with auto MDI MDI X function 100M fiber 2 x SC type connector
9. ic Switch The fiber port of SC type connector can work in multi mode 2Km or single mode 30Km When you connect the fiber port to another one please follow the figure below to connect accordingly Wrong connection will cause the port cannot work normally Multi Mode power budget Min 9dB MAX 190dB Single Mode power budget Min 19dB MAX 26dB SC Connector Cable Wiring SC to SC Tx A A Rx Tx Be B Rx This is a Class 1 Laser LED product Don t stare into R the Laser LED Beam Cabling m Using four twisted pair Category 5 cabling for RJ 45 port connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long 10 m Fiber segment using single mode connector type must use 9 125um single mode fiber cable User can connect two devices in the distance up to 30 Kilometers m Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable User can connect two devices up to 2Km distances 11 Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Side DIN Rail 1 Use the screws to screw on the DIN Rail on the industrial switch 2 Toremove the DIN
10. l switch Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch How to wire the power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of Category 5 cables into the Industrial switch Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex switch PC or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning 7 When all connections are all set and LED lights all show in normal the installation is complete Troubles shooting m Verify that you are using the right power cord adapter Please don t use the power adapter output higher than the power input of this switch or it will burn this switch down m Select the proper UTP STP cable to construct your network Please check that you are using the right cable Use uns
11. nstectedteocecteseiacc ii OV EI EN enasna a 1 pg oe 81010 SE EN 1 FANGES Ne 3 PACO LS see 4 Safety PrECAUOM sassy cae ioacaaedanneeucteomaanawtmaneetends 4 Hardware DeSCTIDtiON ccccseeeeeeseeeeeseeeeeeaees 5 FOM PA are eee 5 TOD VIEW asss Ieas 6 Wiring the Power Inputs ccceseceeseeseeeeeeeeees 6 Wiring the Fault Alarm Contact srnnrrrnnnnnnnnnnnn 7 LED MACIOS sa 7 DIP SWIC ee 8 PONG eaa E AE ase eetaee eee 8 CANA RE EE EE EN 10 Mounting Installation eerrnnrrnrnnrrornnnnnnnnnnnen 12 DIN Rail Mounting wiscesteiteicvons doecesseialedece doveamnesadaes 12 Wall Mount Plate Mounting 0c ceceseeeeee ees 14 Hardware Installation rrronrrrnnrernnrrrrnnrennnre 15 Installation SIGS sinka a 16 Troubles SNOOTING ccccccseeeeeeeeeeeeeeeeeaeeeeees 17 Technical Specification ccccceeeeceeeeeeeeeees 18 Overview Introduction The 4 10 100TX 2 100FX Industrial Switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications High Speed Transmissions The 4 10 100TX 2 100FX Industrial Switch provides you with Fiber port for your fiber optic cable to make a long distance connection The 4 10 100TX 2 100FX Industrial Switch includes a switch controller that can automatically sense transmission speeds 10 100 Mbps The RJ 45 interface can also be auto detected so MDI or MDI X is automati
12. w Inserting the wires it will detect the fault status which the power is failure or port link failure for managed model and form an open circuit Note The wire gauge for the terminal block should be in the range between 12 24 AWG LED Indicators There are few LEDs display the power status and network status located on the front panel of the Industrial switch each of them has its own specific meaning as the table below LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive Fault Red Di Power input 1 and 2 are both active or no power input Link Active Green On Connected to network 1 5 for 1 x 100FX Flashing Networking is active 1 6 for 2 x 100FX Off Not connected to network On Ethernet port full duplex Duplex Collision Flashing Collision of packets occurs Orange 1 4 bit Ethernet port half duplex or not connect to network DIP switch The DIP Switch is used to configure power alarm The default value of DIP switch is OFF DIP Status Description ON Enable Power 1 Alarm OFF Disable Power 1 Alarm 9 ON Enable Power 2 Alarm OFF Disable Power 2 Alarm Ports RJ 45 ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T or 100Base TX devices connections Auto MD
Download Pdf Manuals