1. Cable clamp 1 Turn off the GOT 2 Remove two extension unit covers of the GOT 3 Connect the extension interface relay board to the extend I F 2 on the GOT Remove the connector cover from the board 4 Fit the multimedia unit in the GOT case Remove the connector cover 5 Tighten four mounting screws with a torque of 0 36 to 0 48 Nem to fix the unit 6 Tighten two board fixing screws with a torque of 0 36 to 0 48 Nem to fix the board 7 For mounting any extension unit on the multimedia unit remove the connector cover and the stickers For mounting no extension unit on the multimedia unit cover over four mounting screws with the accessory stickers to avoid static electricity Keep the connector cover fixed Keep all the stickers fixed Connector cover Accessory sticker Sticker Accessory sticker Point Precautions for connecting sound I O devices Do not connect or disconnect the cables of the sound I O sections during sound input or output Do not connect devices other than sound I O devices to the sound I O sections of the multimedia unit Removing multimedia unit Remove the board fixing screws and then remove the multimedia unit by tilting A PULL so that the connector is not damaged Refer to 6 Cable clamp 1 Removing cable clamp band The cable clamp band can be removed after the cables are fixed Press the tab of the cable clamp upwa
2. cause a failure or malfunctions of the unit CAUTION When installing a CF card into this unit insert it into the card slot of this unit until the CF card eject button pops out Failure to do so may cause a malfunction due to poor contact Before inserting or removing a CF card into from this unit turn the CF card access switch off Failure to do so may corrupt data on the CF card When removing a CF card from the GOT support it by hand as it may pop out Failure to do so may cause the CF card to drop from the unit resulting in a damage or failure DISPOSAL PRECAUTIONS CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User s Manual for the GOT used as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Manuals The following shows manuals relevant to this product Detailed Manual Manual number Manual name Model code GT16 User s Manual Hardware SH 080928ENG Sold separately 1D7MD3 GT16 User s Manual Basic Utility SH 080929ENG Sold separately 1D7MD4 GOT1000 Series Connection Manual Microcomputer MODBUS Products Peripherals for GT
3. Works3 Sold separately SH 080871ENG 1D7MC5 GT Designer3 Version1 Screen Design Manual SH 080867ENG Functions Sold separately 1D7MC1 Relevant Manuals For relevant manuals refer to the PDF manuals stored in the CD ROM for the drawing software used 2008 MITSUBISHI ELECTRIC CORPORATION Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi GOT EMC and Low Voltage Directives compliant into other machinery or equipment refer to EMC AND LOW VOLTAGE DIRECTIVES of the General Description included with the GOT used The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on the rating plate of the GOT Compliance with the Radio Waves Act South Korea This product complies with the Radio Waves Act South Korea Note the following when using the product in South Korea o JIE ASS AS AMMARSIIEAM BOA CE NSA 0 SS FOYSH Uber AAAS ASMA ASHE AS SAO z SUC The product is for business use Class A and meets the electromagnetic compatibility requirements The seller and the user must note the above point and use the product in a place except for home Packing List After unpacking the box check that the following products are included Product Quantity Multimedia unit Mounting screw set 4 screws 4 GT16M MMR stickers Extension
4. file ome A 9 MPEG 4 Part 2 SP LV4 Resolution maximum frame rate BNC connector 3 5 stereo mini jack straight type 3 5 stereo mini jack straight type VGA 15fps QVGA 30fps 3 3VDC 0 51A 5 0VDC 0 27A Weight 0 28kg 0 611b 1 Compatible with PAL and CCIR formats only Internal current consumption 3 PART NAMES AND EXTERNAL DIMENSIONS 3 1 Multimedia Unit 3 11 GOT main unit 133 5 24 Im O QO f i 10 128 5 04 98 3 86 i Bg A iJ o 38 1 50 J3 4 g gS 11 8 7 24 0 94 1 x Dimensions of X when qp mounted the GOT EA Meco 8 x Dimensions Pq og SOT of X Fg Ng 45 33 5 1 32 12 1 32 0 1 26 ba 10 4 _ 35 0 1 38 e 8 4 37 0 1 46 Unit mm inch 32 1 26 46 1 81 86 3 39 111 4 37 Description Connector for video 1 Connector for connecting a coaxial cable input 2 Interface connector Connector connected to the GOT 3 Extension connector Connector for connecting an extension unit 4 CF card interface Interface for inserting a CF card CF card access Switch for enabling or disab
5. interface relay board Cable clamp for sound I O 1 OVERVIEW This user s manual describes GT16 multimedia unit hereinafter referred to as the multimedia unit The following functions are available by mounting the multimedia unit on the GT16 M The GOT displays a video image taken by a video camera or the GOT stores the video image as a video file in a CF card and plays the file When an error occurs a video image taken 120 seconds before and after the error up to 240 seconds can be stored as a video file in a CF card With the Ethernet connection the GOT sends a video file to the personal computer using the FTP server function Personal computer CF card in the GOT GoT C CF card in the i multimedia unit Video fle Video Video camera K amp S Ethernet image Xe GT16M MMR 1 To store video files in the personal computer the FTP server function of the GOT and the multimedia interaction tool are required 2 Power on the GOT simultaneously with the video camera 3 Depending on the video camera type noise from the power supply cable of the video camera may cause malfunction of the GOT or a programmable controller In this case attach the following line filter to the power supply line of the video camera Recommended line filter TDK ZHC2203 11 or equivalent products To use the multimedia unit set the communication settings For the settings and system con
6. or malfunctions CAUTION Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit Not doing so can cause a fire failure or malfunction Make sure to securely connect the cable to the connector of unit Incorrect connection may cause malfunctions STARTUP AND MAINTENANCE PRECAUTIONS lt gt DANGER Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit Do not disassemble or modify the unit and the CF card Doing so can cause a failure malfunction injury or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure CAUTION Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the unit Doing so can cause unit or cable damage or a malfunction due to a cable contact fault Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may
7. DING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require ap tion to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan June 2011
8. Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M 1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 2MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUIL
9. MITSUBISHI GT16 Multimedia Unit User s Manual GT16M MMR Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT16M MMR U MODEL CODE 1D7M87 IB NA 0800432 E 1106 MEE GRAPHIC OPERATION TERMINAL GOTio900 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals intro duced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as DANGER and CAUTION ere ee ee ee ee ee ee ee ee ee eA I R I Indicates that incorrect handling may cause hazardous I O DANGER conditions resulting in death or severe injury I l I l Indicates that incorrect handling may cause hazardous I A CAUTION conditions resulting in medium or slight personal injury I or physical damage I a ey er Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are important to per sonal safety Please save this manual to make it accessible when required and always forward it to the end user DESIGN PRECAUTIONS CAUTIO
10. N Do not bunch the control wires or communication cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100mm 3 94 inches otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction CAUTION Use this unit in the environment that satisfies the general specifications described in the User s Manual for the GOT used Not doing so can cause an electric shock fire malfunction or product damage or deterioration Do not drop the unit or subject it to string shock Aunit damage may result When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage WIRING PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage
11. figurations refer to GOT1000 Series Connection Manual Microcomputer MODBUS Products Peripherals for GT Works3 For the multimedia function refer to GT Designer3 Version1 Screen Design Manual Functions 2 SPECIFICATIONS The following shows the performance specifications of the multimedia unit The general specifications of the multimedia unit are the same as those of the GOT For the general specifications of the GOT refer to the User s Manual for the GOT used Tem Specifications Input Color NTSC format PAL format interlaced format format Monochrome EIA format CCIR format interlaced format Number of channels T channel Video input Video input signal Vp p 75 Q composite signal section Display size dot paa Connector for external connection Applicable wire size 75 Q shielded coaxial cable al shield cable Number of channels T channel Sound input Sound input signal 1 Vrms section Connector for external connection Number of channels T channel Sound output Sound output signal 1 Vrms Rated load 10k Q section Connector for external connection CF Card I F Slot Compact flash Slot TYPE1 1 channel section Mode True IDE mode Number of channels T channel Ethernet I F Connector for external RJ 45 jack section connection Data transfer method TOBASE 1 100BASE TX File format 3GP MP4 Video coding decodin Video
12. human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system el Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 South Africa Circuit Breaker
13. ling access to the CF card 5 itch ON CF card accessed his OFF CF card not accessed 6 CF card access LED LED lamp lit when the CF card is accessed Terminal for connecting the cable of the sound input 7 Sound input terminal device Sound output Terminal for connecting the cable of the sound output 8 terminal device 9 Ethernet interface Connector for Ethernet communication 10 Board fixing screw Screw for fixing the extension interface relay board 11 Mounting screw Screw for fixing the multimedia unit 12 Rating plate 3 2 Extension Interface Relay Board o 2 e 2 a 64 2 52 I TL im E sal ies Unit mm inch 4 INSTALLATION PROCEDURE 4 1 Cable Connection 1 Connect the cables of the sound I O devices to the multimedia unit 2 Attach the cable clamp to the unit Position the cable clamp band outside and insert the cable clamp to section A shown in the following figure until it clicks For the band inserting direction refer to the arrow The cable clamp is the RST 1NB manufactured by TAKEUCHI INDUSTRY CO LTD 3 Put the cables of the sound I O devices through the looped cable clamp band and pull the band to fix the cables Cable of the external I O device ZA 4 2 Unit Installation The installation procedure for the multimedia unit is explained using the GT1685
14. rd using a screwdriver and others and pull out the band 2 Removing cables from multimedia unit The cables of the sound I O devices can be removed from the unit even if the cables are fixed with the cable clamp Remove the cables by pressing the cable clamp from both directions arrow A 5 CF CARD INSTALLATION REMOVAL PROCEDURE 5 1 Installation 1 Open the CF card cover and turn off the CF card access switch of the unit 2 Insert a CF card into the CF card interface with the front side facing up 3 Turn on the CF card access switch 5 2 Removal 1 Open the CF card cover Turn off the CF card access switch and check that the CF card access LED turns off When the CF card access LED is off the CF card can be removed even while the GOT power is on 2 Press the CF card eject button to pop out the CF card and remove the card Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties ZA For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to