CL1X4-D1B2 CC-Link/LT Remote I/O Module User`s Manual
Contents
1. 1 847 478 2100 China Mitsubishi Electric Automation China Ltd Brazil MELCO TEC Representacao Comercial e No 1386 Hongqiao Road Mitsubishi Electric Assessoria Tecnica Ltda Automation Center Changning District Av Paulista 1439 cj74 Bela Vista Sao Shanghai China Paulo CEP 01311 200 SP Brazil Tel 86 21 2322 3030 Tel 55 11 3146 2200 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German Branch 6F No 105 Wugong 3rd Road Wugu District Gothaer Strasse 8 D 40880 Ratingen Germany New Taipei City 24889 Taiwan R O C Tel 49 2102 486 0 Tel 886 2 2299 2499 UK Mitsubishi Electric Europe B V UK Branch Korea Mitsubishi Electric Automation Korea Co Ltd Travellers Lane Hatfield Hertfordshire 3F 1480 6 Gayang Dong Gangseo Gu AL10 8XB UK Seoul 157 200 Korea Tel 44 1707 27 6100 f Tel 82 2 3660 9530 Italy Mitsubishi Electric Europe B V Italian Branch Singapore Mitsubishi Electric Asia Pte Ltd Industrial Viale Colleoni 7 20864 Agrate Brianza Division Milano Italy 307 Alexandra Road Mitsubishi Electric Tel 39 039 60531 Building Singapore 159943 Spain Mitsubishi Electric Europe B V Spanish Branch Tel 65 6470 2308 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Soi Serithai 54 T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2906 3238 P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No
2. For I O wiring use crimp style terminals of the following dimensions 3 2 0 13 o 3 2 0 13 6 2 mm 0 24 or less When wiring two cables to one terminal 6 2 mm 0 24 or less When wiring one cable to one terminal Crimp style terminal Crimp style Terminal screw terminal Terminal screw Terminal Terminal e RAV1 25 3 e V1 25 3 manufactured by JST Mfg Co Ltd e 1 25 3 and TG1 25 3 manufactured by NICHIFU Co Ltd Applicable crimp Use a crimp style terminal in a status in which no force is applied on the cable 4 4 Module terminal screw Tighten the terminal screws M3 screws on the terminal block with a tightening torque of 0 42 to 0 58 N m Do not tighten terminal screws exceeding the specified torque Failure to do so may cause short circuit equipment failures or malfunctions 5 Specifications 5 1 General specifications Specification 0 to 55 C 32 to 131 F temperature Ambient storage 25 to 75 C 13 to 167 F temperature 5 to 95 RH Dew condensation shall not be considered 5 to 95 RH Dew condensation shall not be considered Ambient storage Number of times of sweep When intermittent vibration is present Ral ampitude 10to57Hz 0 075mm When continuous vibration is present and Z 10 times in Frequency Acceleration Half amplitude directions 10to57Hz _ 0 035mm _ for 80 min mpact resistance 1 perating atmosphere perating
3. 6 Outside Dimensions 50 1 97 2 4 5 0 18 mounting a m hole M4 mounting screw N 10 0 40 S Center of DIN rail ae me PW LRUN LERR 0128 E G Q O O OC0O0O0 a Me re IR 3 Vv i N 2 N J IN pebes 2 w STATION NO 15ms Oo oO nal l H o gt Oo T T T T XO i LES a ae i LINK PW l HN X2 i re iin Bm Oe N i 2 L 41 5 1 64 0 4 0 02 40 1 58 o 1 D Unit mm inches This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use e This produc
4. new setting becomes valid when the power is DC24B turned OFF once then ON again Flickering at a intermittent interval When a terminal resistor is not attached or when the module or a connection cable is affected by noise ON while the input is ON Extinguished while the input is 0123 OFF a a Input operation indicator NI J Interface Connector for CC Link LT communication line module power supply 24G DB DA 24V Terminal block Terminal block for connecting input signals and I O power for I O interface supply Set the 10 s digit of the station No using STATION NO 10 STATION NO 20 and STATION NO 40 Set the 1 s digit of the station No using STATION NO 1 STATION NO 2 STATION NO 4 and STATION NO 8 Factory default All bits are OFF Make sure to set the station No in the range from 1 to 64 If any station No outside the range from 1 to 64 is set it is regarded as an error and the L ERR LED lights Example When setting the station No to 32 set the DIP switch as follows Station No 40 20 10 8 4 2 1 a2 OFF ON ON OFF OFF ON OFF Sets the response speed ON 0 5 ms fast response type OFF 1 5 ms standard type 3 Installation The CL1X4 D1B2 can be installed to DIN rail or directly installed using mounting screws Each installation procedu
5. 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Carretera de Rubi 76 80 AC 420 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 Czech Republic Mitsubishi Electric Europe B V 0 s Czech office Avenir Business Park Radicka 751 113e 158 00 Praha5 Czech Republic Indonesia Box 5045 Indonesia Tel 420 251 551 470 f Te 62 21 663 0833 Poland Mitsubishi Electric Europe B V Polish Branch India Mitsubishi Electric India Pvt Ltd ul Krakowska 50 32 083 Balice Poland 2nd Floor Tower A amp B Cyber Greens DLF Tel 48 12 630 47 00 Cyber City DLF Phase lll Gurgaon 122002 Russia Mitsubishi Electric Europe B V Russian Haryana India Branch St Petersburg office Tel 91 124 463 0300 Piskarevsky pr 2 bld 2 lit Sch BC Australia Mitsubishi Electric Australia Pty Ltd Benua office 720 195027 348 Victoria Road PO BOX11 Rydalmere St Petersburg Russia N S W 2116 Australia Tel 7 812 633 3497 Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Specifications subject to change without notice
6. WARNING and CAUTION Procedures which may lead to a dangerous condition WARNING and cause death or serious injury if not carried out CAUTION properly Procedures which may lead to a dangerous condition and cause superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS e Configure an interlock circuit in a sequence program so that the system operates on the safety side using the communication status information in the event the data link falls into a communication problem Otherwise erroneous output and malfunction may result in accidents e Remote input and output can not be switched ON or OFF when a problem occurs in the remote I O modules Therefore build an external monitoring circuit that will monitor any input signals that could cause a serious accident CAUTION e Do not have control cables and communication cables bundled with or placed near by the main circuit and or power cables Wire those cables at least 100mm 3 94 inch away from the main circuit and or power cables It may cause malfunction due to noise interference e Use the module and the flat cable dedicated to CC L
7. altitude nstallation place ver voltage category 2 000m 6561 8 or less 2 Inside control panel Degree of contamination 2 or less 147 m s2 3 times in each of X Y and Z directions Corrosive gas shall not be present 3 5 Notes 2 3 4 5 The criterion is shown in IEC61131 2 The module cannot be used in an environment pressurized above the atmospheric pressure which can be generated around the altitude of O m If the module is used in such an environment it may fail The module can be used in any environment even outside the control panel as far as the requirements of the ambient operating temperature the ambient operating humidity etc are satisfied This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the rated voltage of 300V is 2500V This index indicates the degree of conductive generating substances in the environment in which the module is used The degree of contamination 2 indicates that contamination is caused by generation of only non conductive substances In this degree however temporary conduction may be caused by accidental condensation 5 2 Input specifications Input method Number of inputs Isolati
8. program so that the system operates on the safety side using the communication status information in the event the data link falls into a communication problem Otherwise erroneous output and malfunction may result in accidents e Remote input and output can not be switched ON or OFF when a problem occurs in the remote I O modules Therefore build an external monitoring circuit that will monitor any input signals that could cause a serious accident CAUTION e Do not have control cables and communication cables bundled with or placed near by the main circuit and or power cables Wire those cables at least 100mm 3 94 inch away from the main circuit and or power cables It may cause malfunction due to noise interference e Use the module and the flat cable dedicated to CC Link LT without applying any force on them Otherwise such cables may be broken or fail INSTALLATION PRECAUTIONS CAUTION e Use the module in an environment that meets the general specifications contained in this manual Using this module in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product e Do not directly touch the module s conductive parts Doing so could cause malfunction or trouble in the module e Tighten the module securely using DIN rail or installation screws within the specified torque range If the screws are too lose the module m
9. specified torque Failure to do so may cause short circuit equipment failures or malfunctions 5 Specifications 5 1 General specifications Specification 0 to 55 C 32 to 131 F temperature Ambient storage 25 to 75 C 13 to 167 F temperature 5 to 95 RH Dew condensation shall not be considered 5 to 95 RH Dew condensation shall not be considered Ambient storage Number of times of sweep 10to57Hz 0 075mm 10 times in and Z Half amplitude directions Toore 003mm r 80min proton aom o perating altitude 2 000m 6561 8 or less 2 nstallation place Inside control panel 3 ver voltage category II or less 4 5 Degree of contamination 2 or less When intermittent vibration is present Impact resistance 1 perating atmosphere Notes 2 3 4 5 The criterion is shown in IEC61131 2 The module cannot be used in an environment pressurized above the atmospheric pressure which can be generated around the altitude of 0 m If the module is used in such an environment it may fail The module can be used in any environment even outside the control panel as far as the requirements of the ambient operating temperature the ambient operating humidity etc are satisfied This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Cat
10. the modules DISPOSAL PRECAUTIONS CAUTION e When disposing of this product treat it as industrial waste TRANSPORTATION AND MAINTENANCE PRECAUTIONS CAUTION e During transportation avoid any impact as the module is a precision instrument Doing so could cause trouble in the module e If is necessary to check the operation of module after transportation in case of any impact damage Notification of CE marking This notification does not guarantee that an entire mechanical module produced in accordance with the contents of the notification comply with the following standards Compliance to EMC standards of the entire mechanical module should be checked by the user manufacturer Attention e This product is designed for use in industrial applications Note e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Standards with which this product complies Type Programmable Controller Open Type Equipment Remote I O module Models Products manufactured from November 1st 2002 to April 30th 2006 are compliant with EN61000 6 4 and EN61131 2 1994 A11 1996 A12 2000 after May 1st 2006 are compliant with EN61131 2 2007 Electromagnetic Compatibility Standards EMC EN61000 6 4 2001 Compliance with all relevant aspects of Electromagnetic compatibility the standard Generic standards Emission standard Radiated Emissions and Mains
11. to DC 24A terminal Connected to DC 24A terminal A AL Detection circuit Detection circuit Sensor PNP e When using a three wire type sensor when using the power supply for sensor other than 24V DC X Detection circuit COMB Replace in the figure with the used input No Notes 1 Bleeder resistor When connecting a two wire type sensor or input equipment containing a parallel resistor select a sensor or equipment whose leakage current is 1 7mA or less If the leakage current is more than 1 7mA connect a bleeder resistor obtained in the following calculation formula Circuit image Leakage current lt Unit Sensor 3 Detection circuit R Input impedance 5 6 kQ i 1 7 mA or less R Bleeder resistor 24V DC R kQ lt 1 7 mA Leakage current mA 1 7 mA x 5 6 kQ The power capacity W of the bleeder resistor R is as follows W Input voltage 2 R e If chattering is present in the external input equipment set 1 5ms e If the ON or OFF time of the input signal is less than 1 5 ms set it to 0 5 ms The ON and OFF time of the input signal are required to be 0 5 ms or more When setting 1 5 ms Set both the ON and OFF time of the input signal to 1 5 ms or more When setting 0 5 ms Set both the ON and OFF time of the input signal to 0 5 ms or more 4 3 Crimp style terminal
12. 120V or less in the rated voltage is assumed Outline of Product This product is a terminal block type input module connected to CC Link LT This product has four input points 24V DC 2 Name and Setting of Each Part and Terminal Arrangement 0123 CO00 Status Input Opetaton indicator LEDs Connector for indicator Input is ON Lit CC Link LT interface LEDs Input is OFF Extinguished i 2 4 5 Connector terminal mounting hole assignment o o oo 6000 M4 mounting MELSEG onf screw 4 24G T CL1X4 D1B2 iii 3 DB ae an an l fe 1 24v L l XO X1 X2 X3 Terminal block for I O interface Orange color Hook for installation to DIN rail DIP switch Terminal arrangement Terminal number and Signal name DC24A X0 x1 DIP switch assignment 0 5ms 402010 8 4 2 1 15ms 1 3 5 7 COMB Status indicator LED 2 4 6 8 ON COMB x2 X3 t ee R ON while the power is supplied L RUN ON while normal operation is executed ON When a communication error or DIP switch setting error occurred Flickering at a constant interval When the setting of the DIP switch was changed while the power was supplied even while the LED is flickering the operation continues The L ERR i
13. 2299 2499 UK Mitsubishi Electric Europe B V UK Branch Korea Mitsubishi Electric Automation Korea Co Ltd Travellers Lane Hatfield Hertfordshire 3F 1480 6 Gayang Dong Gangseo Gu AL10 8XB UK Seoul 157 200 Korea Tel 44 1707 27 6100 Tel 82 2 3660 9530 Italy Mitsubishi Electric Europe B V Italian Branch Singapore Mitsubishi Electric Asia Pte Ltd Industrial Viale Colleoni 7 20864 Agrate Brianza Division Milano Italy 307 Alexandra Road Mitsubishi Electric Tel 39 039 60531 Building Singapore 159943 Spain Mitsubishi Electric Europe B V Spanish Branch Tel 65 6470 2308 Carretera de Rubi 76 80 AC 420 E 08190 Thailand Mitsubishi Electric Automation Thailand Sant Cugat del Valles Barcelona Spain Co Ltd Tel 34 93 565 3131 Bang Chan Industrial Estate No 111 Soi France Mitsubishi Electric Europe B V French Branch Serithai 54 T Kannayao A Kannayao 25 Boulevard des Bouvets F 92741 Bangkok 10230 Thailand Nanterre Cedex France Tel 66 2906 3238 Tel 33 1 5568 5568 Indonesia P T Autoteknindo Sumber Makmur Czech Republic Mitsubishi Electric Europe Muara Karang Selatan Block A Utara No 1 B V o s Czech office Kav No 11 Kawasan Industri Avenir Business Park Radicka 751 113e Pergudangan Jakarta Utara 14440 P O 158 00 Praha5 Czech Republic Box 5045 Indonesia Tel 420 251 551 470 f Tel 3 62 21 663 0833 Poland Mitsubishi Electric Europe B V Polish Branch India Mitsubishi Electric India Pvt Ltd ul Krako
14. EC onf screw 4 24G T CL1X4 D1B2 iii 3 DB ae an an l 1 24v LL u XO LINK PW X1 x2 Terminal block for I O interface Orange color Hook for installation to DIN rail Terminal arrangement Terminal number and Signal name 1 3 5 7 DC24A XO X1 COMB 2 4 6 8 ON DC24B COMB x2 x3 1 ae DIP switch DIP switch assignment 0 5ms 402010 8 4 2 1 15ms ON while the power is supplied L RUN ON while normal operation is executed ON When a communication error or DIP switch setting error occurred Flickering at a constant interval ae When the setting of the DIP switch was changed Status indicator while the power was supplied even while the LED LED is flickering the operation continues The L ERR new setting becomes valid when the power is turned OFF once then ON again Flickering at a intermittent interval When a terminal resistor is not attached or when the module or a connection cable is affected by noise ON while the input is ON Extinguished while the input is 0123 OFF a a Input operation indicator N D Interface Connector for CC Link LT communication line module power supply 24G DB DA 24V Terminal block Terminal block for connecting input signals and I O power for I O interface supply S
15. MITSUBISHI W ELECTRIC Side B JAPANESE ENGLISH CL1X4 D1B2 CC Link LT Remote I O Module Please read this manual thoroughly before starting to use the product and handle the product properly Users Manual MODEL CL1X4 D1B2 MANUAL Number JY997D04101G April 2015 CCink LT SAFETY PRECAUTIONS Read these precautions before using Please read this manual carefully and pay special attention to safely in order to handle this product properly Also pay careful attention to safely and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the user s manual of the CPU module to use for a description of the PLC system safety precautions These SAFETY PRECAUTIONS classify the safety precautions into two categories WARNING and CAUTION Procedures which may lead to a dangerous condition WARNING and cause death or serious injury if not carried out CAUTION properly Procedures which may lead to a dangerous condition and cause superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS e Configure an interlock circuit in a sequence
16. Noise durability 500Vp p Noise width 1us Cycle 25 to 60 Hz by noise simulator Withstand voltage 500V AC for 1 min Isolation resistance Protection class 10 MQ or more between primary area external DC terminal and secondary area internal circuit by 500V DC megger IP2X O part connection method Connection with terminal block DIN rail installation mounted by screws of type Module installation method M4 x 0 7mm 0 03 x 16mm 0 63 or larger Can be installed in six directions 0 06 kg 0 13 Ibs 6 Outside Dimensions 50 1 97 2 4 5 0 18 mounting a hole M4 mounting screw N j 10 0 40 2 Center of DIN rail i 2 A PW LRUN LERR 01 2 3 4 v Oo OO 0 p OO00O0 A Tv T MASE o w i CL1X4 D1B2 Vv a m y g al rmo 4020101842 t 05ms N fo a IN station nol tans 2a i oO 5 H A o _ O LINK PW al EN E Hh i LJ A L 41 5 1 64 0 4 0 02 J 40 1 58 o 1 5 lt a t9 T y Unit mm inches This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent l
17. ay drop from its installation position short circuit or malfunction If the screws are too tight the screws may be damaged which may cause the module to drop from its installation position or short circuit e Install the module on a flat surface If the mounting surface has concave and or convex an excessive force may be applied on the module and nonconformity may be caused WIRING PRECAUTIONS WARNING e Perform installation and wiring after disconnecting the power supply at all phases externally If the power is not disconnected at all phases an electric shock or product damage may result CAUTION e Terminal screws which are not to be used must be tightened always Otherwise there will be a danger of short circuit against the bare solderless terminals e Perform correct wiring for the module according to the product s rated voltage and terminal arrangement Connecting to a power supply different from rating or miss wiring may cause fire product failure or malfunction e Fix terminal screws securely within the regulated torque Loose terminal screws may cause fire and or malfunction If the terminal screws are too tight it may cause short circuit equipment failures or erroneous operation due to damage of the screws e Make sure foreign objects do not get inside the module such as dirt and wire chips It may cause fire product failure or malfunction e Attach a warning label hazard symbol 417 IEC 5036 conc
18. e so that the clearance of 1 to 2mm 0 04 to 0 08 is assured for each module Abplicable screw M4 x 0 7mm 0 03 x 16mm 0 63 or more PP Tightening torque range 0 78 to 1 08 N m 4 Wiring 4 1 External wiring The input terminals of the CL1X4 D1B2 can be wired as positive common or negative common depending on the used sensor Positive common Connector for CC Link LT interface BIDB CL1X4 D1B2 Isolation aie DC DC External power supply of the input part 24V DC Interface terminal block for I O Positive common T 1 DC24A i 2 DC24B COMB Negative common External power supply of the input part 24V DC DC24A DC24B Interface terminal block for I O Negative common 4 2 Connection to sensor Positive common NPN e When using a two wire type sensor When using a three wire type sensor Connected to DC 24A terminal Connected to DC 24A terminal uN Bleeder resistor 1 9 X x Detection Detection circuit circuit Sensor NPN ove COME e When using a three wire type sensor when using the power supply for sensor other than 24V DC Detection circuit COMB Negative common PNP e When using a two wire type sensor When using a three wire type sensor Connected
19. egory II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the rated voltage of 300V is 2500V This index indicates the degree of conductive generating substances in the environment in which the module is used The degree of contamination 2 indicates that contamination is caused by generation of only non conductive substances In this degree however temporary conduction may be caused by accidental condensation 5 2 Input specifications Input method Number of inputs Isolation method Rated input voltage Rated input current Operating voltage range pero FA Approx 4 mA 20 4 to 28 8V DC 24V DC 15 to 20 Ripple ratio Within 5 Max simultaneous ON input points N voltage ON current FF voltage OFF current Input resistance Common wiring method 100 at 24V DC 19 V or more 3 mA or more 11 V orless 1 7 mA or less 5 6 kQ 0 5ms 1 5 ms or less at 24V DC oo Selected by DIP switch default value OFF 1 5ms 0 5ms 1 5 ms or less at 24V DC Selected by DIP switch default value OFF 1 5ms 4 points 1 common 2 points terminal block two wire type ON OFF 5 3 Performance specifications Specification 20 4 to 28 8V DC 24V DC 15 to 20 Ripple ratio Within 5 consumption Max allowable momentary power PS1 1ms failure period Voltage umber of stations 4 8 or 16 point mode 1 station occupied
20. erning the electric shock to the location STARTING AND MAINTENANCE PRECAUTIONS WARNING e Do not touch the terminals when the power is ON It may cause an electric shock or malfunction e Perform cleaning the module or retightening of terminal screws after turning OFF the all external power supply for sure Failure to do so may cause failure or malfunction of the modules CAUTION e Do not disassemble or modify the module Doing so may cause failure malfunction injury or fire e The module case is made of resin do not drop it or subject it to strong shock A module damage may result e Make sure to switch all phases of the external power supply OFF before installing or removing the module to from the panel Failure to do so may cause failure or malfunction of the modules DISPOSAL PRECAUTIONS CAUTION e When disposing of this product treat it as industrial waste TRANSPORTATION AND MAINTENANCE PRECAUTIONS CAUTION e During transportation avoid any impact as the module is a precision instrument Doing so could cause trouble in the module e If is necessary to check the operation of module after transportation in case of any impact damage Notification of CE marking This notification does not guarantee that an entire mechanical module produced in accordance with the contents of the notification comply with the following standards Compliance to EMC standards of the entire mechanical module s
21. et the 10 s digit of the station No using STATION NO 10 STATION NO 20 and STATION NO 40 Set the 1 s digit of the station No using STATION NO 1 STATION NO 2 STATION NO 4 and STATION NO 8 Factory default All bits are OFF Make sure to set the station No in the range from 1 to 64 If any station No outside the range from 1 to 64 is set it is regarded as an error and the L ERR LED lights Example When setting the station No to 32 set the DIP switch as follows Station No 40 20 10 8 4 2 1_ Sets the response speed ON 0 5 ms fast response type OFF 1 5 ms standard type 3 Installation The CL1X4 D1B2 can be installed to DIN rail or directly installed using mounting screws Each installation procedure is described below 3 1 Installation to DIN rail Align the upper DIN rail installation groove in the module with the DIN rail 1 and press the module in that status 2 When removing the module pull the hook downward for installation to DIN rail 3 then remove the module 4 DIN rail mounting screw pitch When installing the module to the DIN rail tighten the mounting screws at the pitch of 200mm 7 87 or less Installation Removal Applicable DIN rail TH35 7 5Fe and TH35 7 5Al 3 2 Direct installation Screw tighten the module by attaching M4 screws to the upper and lower mounting holes two holes in all provided in the module Install the modul
22. for Industrial environment EN61 131 2 1994 A11 1996 A12 2000 Programmable controllers Equipment requirements and tests Terminal Voltage Emissions Compliance with all relevant aspects of the standard RF Immunity Fast transients ESD and Damped oscillatory wave Electromagnetic Compatibility Standards EMC EN61131 2 2007 Programmable controllers Equipment requirements and tests Compliance with all relevant aspects of the standard Radiated Emissions Conducted Emissions Radiated electromagnetic field Fast transient burst Electrostatic discharge High energy surge Voltage drops and interruptions Conducted RF and Power frequency magnetic field For more details please contact the local Mitsubishi Electric sales site e Notes for compliance to EMC regulation It is necessary to install the CL1 series module in a shielded metal control panel e Use this product in Zone A as defined in EN61131 2 1 1 Zone defined in EN61131 2 Separation defined in EN61131 2 for EMC LVD regulation decided depending on condition in industrial setting Zone C Factory mains which is isolated from public mains by dedicated transformers Zone B Dedicated power distribution which is protected by secondary surge protection 300V or less in the rated voltage is assumed Zone A Local power distribution which is isolated from dedicated power distribution by AC DC converters isolation transformers etc
23. hould be checked by the user manufacturer Attention e This product is designed for use in industrial applications Note e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Standards with which this product complies Type Programmable Controller Open Type Equipment Remote I O module Models Products manufactured from November 1st 2002 to April 30th 2006 are compliant with EN61000 6 4 and EN61131 2 1994 A11 1996 A12 2000 after May 1st 2006 are compliant with EN61131 2 2007 Electromagnetic Compatibility Standards EMC EN61000 6 4 2001 Electromagnetic compatibility Compliance with all relevant aspects of the standard Generic standards Emission standard Radiated Emissions and Mains for Industrial environment EN61 131 2 1994 A11 1996 A12 2000 Programmable controllers Equipment requirements and tests Terminal Voltage Emissions Compliance with all relevant aspects of the standard RF Immunity Fast transients ESD and Damped oscillatory wave Electromagnetic Compatibility Standards EMC Compliance with all relevant aspects of the standard Radiated Emissions Conducted Emissions Radiated electromagnetic field Fast transient burst Electrostatic discharge High energy surge Voltage drops and interruptions Conducted RF and Power frequency magnetic field For more details please contact the local Mitsubishi Electric
24. icenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system i a L Ua a a EEE Country Region Sales office Tel Country Region Sales office Tel USA Mitsubishi Electric Automation Inc South Africa CBI Electric 500 Corporate Woods Parkway Vernon Private Bag 2016 ZA 1600 Isando South Africa Hills IL 60061 USA Tel 27 11 977 0770 Tel
25. ink LT without applying any force on them Otherwise such cables may be broken or fail INSTALLATION PRECAUTIONS CAUTION e Use the module in an environment that meets the general specifications contained in this manual Using this module in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product e Do not directly touch the module s conductive parts Doing so could cause malfunction or trouble in the module e Tighten the module securely using DIN rail or installation screws within the specified torque range If the screws are too lose the module may drop from its installation position short circuit or malfunction If the screws are too tight the screws may be damaged which may cause the module to drop from its installation position or short circuit e Install the module on a flat surface If the mounting surface has concave and or convex an excessive force may be applied on the module and nonconformity may be caused WIRING PRECAUTIONS WARNING e Perform installation and wiring after disconnecting the power supply at all phases externally If the power is not disconnected at all phases an electric shock or product damage may result CAUTION e Terminal screws which are not to be used must be tightened always Otherwise there will be a danger of short circuit against the bare solderless termi
26. nals e Perform correct wiring for the module according to the product s rated voltage and terminal arrangement Connecting to a power supply different from rating or miss wiring may cause fire product failure or malfunction e Fix terminal screws securely within the regulated torque Loose terminal screws may cause fire and or malfunction If the terminal screws are too tight it may cause short circuit equipment failures or erroneous operation due to damage of the screws e Make sure foreign objects do not get inside the module such as dirt and wire chips It may cause fire product failure or malfunction e Attach a warning label hazard symbol 417 IEC 5036 concerning the electric shock to the location STARTING AND MAINTENANCE PRECAUTIONS WARNING e Do not touch the terminals when the power is ON It may cause an electric shock or malfunction e Perform cleaning the module or retightening of terminal screws after turning OFF the all external power supply for sure Failure to do so may cause failure or malfunction of the modules CAUTION e Do not disassemble or modify the module Doing so may cause failure malfunction injury or fire e The module case is made of resin do not drop it or subject it to strong shock A module damage may result e Make sure to switch all phases of the external power supply OFF before installing or removing the module to from the panel Failure to do so may cause failure or malfunction of
27. of the input part 24V DC DC24A DC24B Interface terminal block for I O Negative common 4 2 Connection to sensor Positive common NPN e When using a two wire type sensor When using a three wire type sensor Connected to DC 24A terminal Connected to DC 24A terminal A Bleeder resistor 1 2 ee 2 x Detection Detection circuit circuit Sensor NPN COME GOMe e When using a three wire type sensor when using the power supply for sensor other than 24V DC Detection circuit Negative common PNP e When using a two wire type sensor When using a three wire type sensor Connected to DC 24A terminal Connected to DC 24A terminal AN A Bleeder resistor 1 x x Detection circuit Detection circuit Sensor PNP COMB COMB e When using a three wire type sensor when using the power supply for sensor other than 24V DC Detection circuit COMB Replace in the figure with the used input No Notes 1 Bleeder resistor When connecting a two wire type sensor or input equipment containing a parallel resistor select a sensor or equipment whose leakage current is 1 7mA or less If the leakage current is more than 1 7mA connect a bleeder resistor obtained in the following calculation formula Circuit image Leakage current Uni
28. on method Rated input voltage Rated input current Operating voltage range oprox mA Approx 4 mA 20 4 to 28 8V DC 24V DC 15 to 20 Ripple ratio Within 5 Max simultaneous ON input points o N voltage ON current 19 V or more 3 mA or more 100 at 24V DC OFF voltage OFF current 11 V or less 1 7 mA or less Input resistance Common wiring method 5 6 KQ 0 5ms 1 5 ms or less at 24V DC Selected by DIP switch default value OFF 1 5ms 0 5ms 1 5 ms or less at 24V DC Selected by DIP switch default value OFF 1 5ms 4 points 1 common 2 points terminal block two wire type 5 3 Performance specifications Specification Voltage 20 4 to 28 8V DC 24V DC 15 to 20 g Ripple ratio Within 5 40mA when all points are ON consumption Max allowable momentary power PS1 1ms failure period number of Stallone 4 8 or 16 point mode 1 station occupied Noise durability 500Vp p Noise width 1us Cycle 25 to 60 Hz by noise simulator Withstand voltage 500V AC for 1 min Isolation resistance Protection class 10 MQ or more between primary area external DC terminal and secondary area internal circuit by 500V DC megger IP2X I O part connection method Connection with terminal block DIN rail installation mounted by screws of type Module installation method M4 x 0 7mm 0 03 x 16mm 0 63 or larger Can be installed in six directions 0 06 kg 0 13 Ibs
29. re is described below 3 1 Installation to DIN rail Align the upper DIN rail installation groove in the module with the DIN rail 1 and press the module in that status 2 When removing the module pull the hook downward for installation to DIN rail 3 then remove the module 4 DIN rail mounting screw pitch When installing the module to the DIN rail tighten the mounting screws at the pitch of 200mm 7 87 or less Installation Removal Applicable DIN rail TH35 7 5Fe and TH35 7 5Al 3 2 Direct installation Screw tighten the module by attaching M4 screws to the upper and lower mounting holes two holes in all provided in the module Install the module so that the clearance of 1 to 2mm 0 04 to 0 08 is assured for each module Abplicable screw M4 x 0 7mm 0 03 x 16mm 0 63 or more PP Tightening torque range 0 78 to 1 08 N m 4 Wiring 4 1 External wiring The input terminals of the CL1X4 D1B2 can be wired as positive common or negative common depending on the used sensor Positive common Connector for CC Link LT interface BIDB CL1X4 D1B2 Isolation O DC External power supply of the input part 24V DC Interface terminal block for I O Positive common 1 DC24A DC24B _ _ 3 xo_ 6X2 8 X3_ Negative common External power supply
30. sales site e Notes for compliance to EMC regulation It is necessary to install the CL1 series module in a shielded metal control panel e Use this product in Zone A as defined in EN61131 2 1 Zone defined in EN61131 2 Separation defined in EN61131 2 for EMC LVD regulation decided depending on condition in industrial setting Zone C Factory mains which is isolated from public mains by dedicated transformers Zone B Dedicated power distribution which is protected by secondary surge protection 300V or less in the rated voltage is assumed EN61131 2 2007 Programmable controllers Equipment requirements and tests Zone A Local power distribution which is isolated from dedicated power distribution by AC DC converters isolation transformers etc 120V or less in the rated voltage is assumed 1 Outline of Product This product is a terminal block type input module connected to CC Link LT This product has four input points 24V DC 2 Name and Setting of Each Part and Terminal Arrangement 0123 CO00 Status Input operation indicator LEDs Connector for indicator Input is ON Lit CC Link LT interface LEDs Input is OFF Extinguished 2 2 04 5 Connector terminal a hole PW LRUN LERR viza A gn assignment o 0 00 0000 i M4 mounting MELS
31. t Input impedance 5 6 kQ i 1 7 mA or less Detection circuit R Bleeder resistor R kQ lt 1 7 mA Leakage current mA 1 7 mA x 5 6 kQ The power capacity W of the bleeder resistor R is as follows W Input voltage 2 R e If chattering is present in the external input equipment set 1 5ms e f the ON or OFF time of the input signal is less than 1 5 ms set it to 0 5 ms The ON and OFF time of the input signal are required to be 0 5 ms or more When setting 1 5 ms Set both the ON and OFF time of the input signal to 1 5 ms or more When setting 0 5 ms Set both the ON and OFF time of the input signal to 0 5 ms or more 4 3 Crimp style terminal For I O wiring use crimp style terminals of the following dimensions 3 2 0 13 3 2 0 13 6 2 mm 0 24 or less When wiring two cables to one terminal 6 2 mm 0 24 or less When wiring one cable to one terminal Crimp style terminal Crimp style l Terminal screw terminal Terminal screw Terminal Terminal e RAV1 25 3 e V1 25 3 manufactured by JST Mfg Co Ltd e 1 25 3 and TG1 25 3 manufactured by NICHIFU Co Ltd Applicable crimp Use a crimp style terminal in a status in which no force is applied on the cable 4 4 Module terminal screw Tighten the terminal screws M3 screws on the terminal block with a tightening torque of 0 42 to 0 58 N m Do not tighten terminal screws exceeding the
32. t has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel South Africa CBI Electric Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 977 0770 Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 USA Tel 1 847 478 2100 China Mitsubishi Electric Automation China Ltd Brazil MELCO TEC Representacao Comercial e No 1386 Hongqiao Road Mitsubishi Electric Assessoria Tecnica Ltda Automation Center Changning District Av Paulista 1439 cj74 Bela Vista Sao Shanghai China Paulo CEP 01311 200 SP Brazil Tel 86 21 2322 3030 Tel 55 11 3146 2200 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German Branch 6F No 105 Wugong 3rd Road Wugu District Gothaer Strasse 8 D 40880 Ratingen Germany New Taipei City 24889 Taiwan R O C Tel 49 2102 486 0 Tel 886 2
33. wska 50 32 083 Balice Poland 2nd Floor Tower A amp B Cyber Greens DLF Tel 48 12 630 47 00 Cyber City DLF Phase lll Gurgaon 122002 Russia Mitsubishi Electric Europe B V Russian Haryana India Branch St Petersburg office Tel 91 124 463 0300 Piskarevsky pr 2 bld 2 lit Sch BC Australia Mitsubishi Electric Australia Pty Ltd Benua office 720 195027 St Petersburg Russia Tel 7 812 633 3497 348 Victoria Road PO BOX11 Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Specifications subject to change without notice MITSUBISHI W ELECTRIC Side B JAPANESE ENGLISH CL1X4 D1B2 CC Link LT Remote I O Module Please read this manual thoroughly before starting to use the product and handle the product properly Users Manual MODEL CL1X4 D1B2 MANUAL Number JY997D04101G April 2015 CCink LT SAFETY PRECAUTIONS Read these precautions before using Please read this manual carefully and pay special attention to safely in order to handle this product properly Also pay careful attention to safely and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the user s manual of the CPU module to use for a description of the PLC system safety precautions These SAFETY PRECAUTIONS classify the safety precautions into two categories