Home
        MODEL AWQ-105 PRO
         Contents
1.                                                                          14  Precaution before the Treatment Pee eee eee eee eee    ee eee eee                               16  Instructions For Use eee eee eee eee eee ee eee eee ee eee eee eee eee ee eee eee eee ee eee eee 16  ELECTRIC STIMULATION SETTINGS eee eee ee eee eee eee eee eee eee eee eee eee 18  Acupuncture therapy  Needles or Electrodes  Pee eee eee eee eee eee ee eee eee ree ey 20  Therapy with Electric Stimulation probe  amp                 21  Precaution After the Treatment eee eee eee eee eee eee eee eee ee eee eee        eee eee 22  Disposal of the Device ee eee eee eee eee ee eee rer eee ee eee eee eee eee eee eee eee eee eee ree 22                                                                                                           23  Trouble                                                                                                     24  Storage and Transportation eee eee eee eee    eee ere eee eee ree eee ee eee eee                   25  Environmental condition eee eee ee eee eee eee eee eee ee eee eee eee eee eee eee eee eee 25       25  Limited Warranty                                 26    AWQ 105 PRO User Manual       Contents of the    AWQ 105 PRO    Package       AWQ 105 PRO    ACUPUNCTURE STIMULATOR            5  1 pe     Search stimulation probe with handgrip electrode 1 pc   Connecting wire  4 assorted colors           4 pcs   Pin lead to duck beak clip adaptor 4 pairs   DC 1 5V C size
2.  LED lights will illuminate        15       AWQ 105 PRO User Manual       Precaution before the Treatment    INSTALLATION     Use the device in an area free from any exposure to water       Avoid storing the device in an environment of high humidity and temperature  and free  from dust or chemical contamination   Place the device on a flat and stable surface free from any inclination and vibration     Do not operate the device in an environment where flammable substances are present       Check to be sure the device is installed with new batteries  and check that all LCD  displays on the device are working properly      Connect all cables correctly      Only use accessories that are supplied with the device      Check that all output intensity knobs are turned OFF      Never operate the device with wet hands to avoid an electric shock       Avoid operating the device consecutively for more than 60 minutes in each treatment     Instructions For Use    POINT DETECTION   BASIC PRINCIPLE  and DIRECT STIMULATION    On the body surface  the electric resistance of an acupuncture point is lower than its  surrounding area  It can be readily located by means of an instrument which is sensitive to  resistance changes  When the metal probe touches a low resistance point  the loudspeaker  gives a sound signal and the digital display shows a numerical value  Its pitch rises and  digital display number increases with the lowering of the electric resistance of the skin  The  pitch will get h
3.  battery  not included in package  6 pcs   Instruction manual 1 pc     The device and its accessories are packed in a sturdy paper carton box           Optional accessories       Different types of connecting clips are available for selection        Crocodile Clip Duck Beak Clip Grasp  Clip Micro Hook Clip    AWQ 105 PRO User Manual       Technical Specifications    Output channel    5 Channels  including one channel for    APD STIM           Normal Output channels    APD STIM output channel                         Output Voltage Hi 0   22 5V 0 40V  Low 0   10V   Output Current Hi 0 45mA 0 80       Low 0 20mA   Pulse width X1  50   500 uS adj  260 US  fixed   X5  10  100 US adj    Pulse Rate X1  4 100 Hz  Adj  10 Hz  fixed   X5  5  500 Hz  Adj        APD  amp  Stim mode    Waveform  Pulse width    Pulse Rate    Mode    LED lights up in    Stim    mode  and is flashing when       Stim button    is pressed     Asymmetric Square Wave with a negative spike    50  500   5 adjustable  when in X1 position    10  100   5 adjustable  when in X5 position    1 100 Hz  adjustable  when in X1 position    5 500 Hz  adjustable  when in X5 position    Constant      pulse rate and width are adjustable from  1 100 Hz   amp  50 500 US respectively at X1  position  and from 5 500 Hz   amp  10 100   5    respectively at X5 position     Modulation   Preset Pulse Rate and width ramp up and    down for 6 seconds per one cycle  both    pulse rate  amp  width are adjustable     Burst   Preset Pulse Ra
4.  or decrease the stimulation intensity   direct  stimulation with preset waveform  frequency and pulse width will be provided by the probe  head    BUZZER ON   OFF switch   the buzzer will emit sounds  during point detection  The buzzer can be turned ON or OFF  by switching it to OFF position        ELECTRIC STIMULATION SETTINGS    This section of the instrument produces stimulating impulses  which act on acupuncture  points or through electrodes for therapeutic purpose   Operating instructions   Ensure that all batteries are inserted correctly  see the  battery information section   Turn on the device by  pressing the POWER ON OFF switch on the left side    of the unit        Insert connecting wires to corresponding output jacks     Connect the wire to acupuncture needles with the clips     18    AWQ 105 PRO User Manual       Select the appropriate mode and adjust frequency  pulse rate  and pulse width as follows     iii   iv     MODE selection switch   the desired waveform mode  CONT   continuous    MODULATE  dense disperse  and BURST  Intermittent  may be selected by  switching this switch  Each waveform mode has a corresponding LED that will  illuminate when the waveform mode is selected    The Frequency and Pulse Width of Ch1 2 and Ch3 4 can be adjusted separately   To adjust the frequency and pulse width of Ch1  amp  Ch2   Turn clockwise  increase   or anticlockwise  decrease  of the  lt Frequency Knob CH1 CH2 gt  to adjust the  frequency  and  lt Pulse Width knob Ch1 C
5.  points  The device utilizes a low intensity  low  frequency pulse multimode generator and either electrodes or alligator clips to deliver  electronic stimuli to the patient  When using the device with electrodes  the electrodes may  be placed on the skin at the treatment location  When using the device with alligator clips   the alligator clips should be connected to acupuncture needles that penetrate the skin at the    acupuncture points     AWQ 105 PRO User Manual       Safety Precautions   Warnings    Heart Patient  Adequate precautionary measures should be considered prior to  stimulating patients suspected of having heart disease  Current clinical data cannot  sufficiently rule out the possibility of adverse results for such patients    Carotid sinus   Do not stimulate over the carotid sinus nerves  especially in patients with  known sinus reflex sensitivity    Neck Stimulation   Severe spasm of the laryngeal and pharyngeal muscles may occur when  the electrodes are placed across the neck or the mouth  This may be strong enough to close  off the airway    Cardiac Pacemakers   Stimulation will inhibit the output of some demand cardiac  pacemakers and therefore  it is not recommended for patients with this type of pacemaker   Pregnancy   The safety of electrical nerve stimulation for use during pregnancy or delivery  has not been established    Other   Electrical nerve stimulation  as presently understood  is a symptomatic treatment  and as such may suppress the progress 
6. 2    10  Frequency Adjustable Turn clockwise  increase  or anticlockwise  decrease  to adjust the   knob for Ch3  amp  Ch4 frequency  pulse rate  of Ch3  amp  Ch4    11   Pulse Width Adjustable   Turn clockwise  increase  or anticlockwise  decrease  to adjust the Pulse   knob for Ch1  amp  Ch2 Width of Ch1  amp  Ch2    12  Pulse Width Adjustable  Turn clockwise  increase  or anticlockwise  decrease  to adjust the Pulse   knob for Ch3  amp  Ch4 Width of Ch3  amp  Ch4    13  Ch1 Ch2 Frequency LCD  Displays the frequency selected for Ch1  amp  Ch2   14  Ch3 Ch4 Frequency LCD  Displays the frequency selected for Ch3  amp  Ch4   15  APD LED It illuminates during point detection  and flash continuously which indicates  the probe reaches or closer to the acupuncture point    16  ISTIM LED It illuminates when Search to treat push button is depressed for immediate  stimulation    17  SEN  STIM LCD This LCD displays the detection accuracy when using the point location          feature of the device     the higher the number  the closer the probe is to the  acupuncture point  It also shows the frequency of stimulation when the  Search to treat push button is depressed for immediate stimulation on a    point right after its location is found        14       AWQ 105 PRO User Manual                                        18  Sensitivity Knob Fine tune the sensitivity of the point location feature of the device  Adjust  the sensitivity knob of the    Loc    to the appropriate position  it t
7. MODEL AWQ 105 PRO    ACUPUNCTURE STIMULATOR   T E N S    5 channels with digital displays        INSTRUCTION MANUAL    AWQ 105 PRO User Manual       AWQ 105 PRO ACUPUNCTURE STIMULATOR   T E N S     It is a professional  brand new unit with 5 channels  It comes up with a modern design and  inherits the features of AWQ series acupunctoscope  This professional unit provides    multiple functions and features  which are essential in daily acupuncture practice     Before using this device  please read the instruction manual carefully as well as read all       Safety Precautions    and    Warnings    carefully to ensure the device is operated properly     AWQ 105 PRO User Manual       Table of Contents    Contents of the    AWQ 105 PRO    Package                                 3  Technical Specifications eee eee eee eee eee eee eee eee eee eee eee eee                   4  Wave Form Pictures eee eee eee eee eee eee eee rere eee eee eee eee eee eee eee eee eee eee eee 6  LRP LUCIO Fates deen ttn                  7  Indication and Its Intended Purpose                                                               7  Safety Precautions   Warnings                                                    8  Features  amp  Advantages  eee    eee eee reer eer ee eee rere eee eee ree eee ee eee eee          9  Battery                                                     11  Indications and Controls eee eee eee eee eee eee eee eee eee eee eee eee eee eee eee eee 12  Operation of             8      
8. and convenient connection to needles   search to treat probe for point detection  amp  electric stimulation  and optional accessories    which expand its function to a powerful T E N S device as well     Search   Stim Probe       Search to treat push button    10    AWQ 105 PRO User Manual       Battery Information    Your stimulator requires 6 pcs  1 5V battery  not included   use    C type  LR14     or its  equivalent type of battery  The batteries can be replaced by opening the battery door on the  bottom side of the device  Slide the battery door off  remove the old batteries and insert the  new batteries  Insert the batteries correctly into the battery compartment by making sure the  direction of the positive and negative poles of each battery match the illustrations inside the  battery compartment  Be sure that each battery used is a fresh new battery  Once the  batteries have been properly seated inside the battery compartment  the battery door should  be closed  Battery life expectancy is between 4 to 20 treatment hours depending on current  settings and treatment length  Many short treatments yield longer battery life than fewer  longer treatments      To avoid battery leakage  remove the battery if the device will not be used for       extended period of time      A specially designed battery compartment is used in this device to ensure easy and  proper insertion as well as securely hold the batteries in place            u ge  xT N AN  N      Special design of batte
9. charged to the customers on the basis of rates which  are available on request  Except for personal injury  no liability is held in either tort or  contract for any loss or damage  direct  consequential  or incidental arising out of the use     misuse  or inability to use this product     Serial No          located on the rear side of the device  next to the battery compartment door     Date Purchased       Customer  Please record this information    26    
10. h2 gt  to adjust the pulse width    To adjust the frequency and pulse width of Ch3  amp  Ch4   Turn clockwise  increase   or anticlockwise  decrease  of the  lt Frequency Knob CH3 CH4 gt  to adjust the  frequency  and  lt Pulse Width knob Ch3 Ch4 gt  to adjust the pulse width    Ch1 Ch2 Frequency LCD will display the frequency for Ch1  amp  Ch2 when selected   Ch3 Ch4 Frequency LCD will display the frequency for Ch3  amp  Ch4 when selected     A X1 X5 multiplier switch is provided for selecting the frequency and pulse width of the    output in normal range of frequency at 1   100 Hz   pulse width at 50 500us  or multiplies 5   i e  5   500 Hz   frequency   and 10 100 us  pulse width      The channel output intensity for all channels is adjusted by rotating the knob of Ch1   4 INT    respectively in clockwise direction  it will first turn on the output channel and then increase    the current output  or vise versa      Two ranges  High  Low  of output intensity are provided  If maximum intensity in Low range    is not sufficient  switch it to High range for stronger intensity output     Select the timer duration of treatment for 15  30 minutes or continuously by switching the    Timer switch to the selected position     19    AWQ 105 PRO User Manual       Acupuncture therapy  Needles or Electrodes     Turn all    intensity    knobs to OFF position and slide the HI LOW switch to the    Hi    or     Lo    position as required  HI  for electrode stimulation  or LOW  for needle st
11. igher and the numerical value will increase as the probe moves closer to the  acupuncture point  With this instrument and method of detection  acupuncture points  located usually produce a strong sensation and reaction to electric stimulation  and will    achieve the best therapeutic results     16    AWQ 105 PRO User Manual       Ensure that all batteries are inserted correctly  see  the battery information section   Turn on the device  by pressing the POWER ON OFF switch on the left  side of the unit    Insert the Search stimulation probe with handgrip  electrode into the APD STIM socket     Adjust the sensitivity by turning the sensitivity knob   When the air humidity is wet  turn the knob  anti clockwise to decrease sensitivity  If it is too dry        turn the knob clockwise to increase sensitivity  Sensitivity knob    Touch the hand grounding pole with the probe tip  the buzzer will give a sharp sound signal   the digital display will show increasing numbers  and the    ADP    LED will flash continuously  indicating that the point location capabilities of the device are working properly     Let the patient grasp the hand pole in one hand  Search for the acupuncture point with the  probe tip on the patient   s skin in the appropriate anatomical location  When doing this  the  probe should be held in a vertical position perpendicular to the surface of skin  The pressure  and duration in touching the point with the probe should be kept constant  If too much  pressure is ap
12. imulation   Apply acupuncture needles or electrodes to patient    Insert alligator type connecting wires into 1  2  3 or 4 sockets and fasten their clips to  the acupuncture needles or electrodes  The number of channels used depends on the    number of needles or electrodes used in each treatment   CH4 CH3 SEN   STIM CH2 CH1       Set the desired mode  frequency  pulse rate   pulse width and operation time with the    switches as mentioned above     Adjust the intensity of each channel to appropriate  setting  The intensity current of each output channel  can be adjusted from 0 mA to 20 mA when the     HI LOW    switch is switch to the    LOW    range or 0 to  45 mA when the    HI LOW    switch is switch to the             position  Rotating the INTENSITY knob will increase        or decrease  the intensity     20    AWQ 105 PRO User Manual       Therapy with Electric Stimulation probe  amp  Settings       Use the Search Stimulation probe  point detector with hand pole  by placing the probe  tip onto the acupuncture point or another selected part of the skin                STI in Search to treat mode    il APD in Search mode        Search   Stim Probe    Search to treat ME a       Insert the Search stimulation probe with handgrip  electrode into the APD STIM socket  To stimulate  the acupuncture point with the probe tip  make sure  the probe tip is touching the treated point or area       e     and press the search to treat button on the probe Socket for Search   Stim   The i
13. ntensity is regulated by the STIM Channel   probe  direct stimulation with fixed waveform  frequency    and pulse width will be provided by the probe head     NOTE   The output intensity of    Stim    is in High range intensity  0 80 mA  and frequency is  fixed at 10 Hz  SEN STIM LCD will display the Hz during direct stimulation      21    AWQ 105 PRO User Manual       Precaution After the Treatment    After use  turn all output knobs to OFF position  and press the POWER SWITCH to turn off    the device     Keep the device clean and Store it in a clean and dry place     Explanation of symbols    The following symbols are used in this device        6 A A a    Read Instruction                        Year of  Part Manufacture  5 N       0197  Serial Number Authorised CE 0197 mark of conformity   Representative in The device is complied with the Essential Requirements for  the European Medical Devices according to EC Directive 93 42 EEC    Community    Disposal of the Device    Please follow the local environmental requirements when disposing of the device  or its    accessories  or packing materials     22    AWQ 105 PRO User Manual       Maintenance    Maintenance of the stimulator is limited to cleaning the stimulator battery contacts and  replacing lead wires when they become old    The stimulator operates on DC 1 5 volt x 6 pcs  Batteries  not included   When adequate  stimulation can no longer be maintained  change the batteries    Remove the old batteries and replace them 
14. ocal    authorized dealer or to the manufacturer as listed in this manual for repair or service           Problem Solution  Indicator lights up but device      Check control settings  are they set to values prescribed as  does not function properly  desired     IL  Check if frequency control is turned on  not too low  or at zero  setting    II  Are needles or electrodes firmly fixed and in proper position    IV  Check connecting wire  Make sure all alligator clips are firmly  connected to the needles or electrodes    V  Replace connecting wire with another to insure the wire is not    broken        Low battery lamp illuminates  Replace batteries with new ones              No indicators light up  Replace batteries with new ones        1  Battery replacement   Batteries should be replaced whenever sufficient stimulation  cannot be maintained    2  Care of Device   The stimulator and connecting wires should be kept clean  The  stimulator should not be immersed in any liquid  Avoiding rough use will help prevent    premature failure     24          AWQ 105 PRO User Manual       Storage and Transportation    Store the device in a dry location free from dust and contamination where the temperature  remains fairly constant and within the range of 10     to 50  C  50  F to 122  F      Do not drop  mishandle  or expose to temperature or humidity extremes  lt outside the range  of 10  C to 50  C  50  F to 122  F   15 95  RH non condensing gt   Do not use if the device    malfunctions o
15. of pain which would otherwise serve as a protective  influence on the outcome of a disease process  The potential for physical and or  psychological dependence upon nerve stimulation as a means of relieving pain has not yet  been determined    It has been noted that some patients find the sensation of electrical stimulation extremely  unpleasant and should probably be excluded from further use of the stimulator    Do not apply electrical nerve stimulation when pain syndromes are undiagnosed until  etiology is established    Do not apply electrical nerve stimulation current transcerebrally    Electrical nerve stimulation devices should be used only under the continued supervision of  a physician  Electronic monitoring equipment  such as EKG monitors and EKG alarms  may  not operate properly when electrical nerve stimulation is in use    Avoid use in post operative recovery rooms when a heart monitor is on     Keep out of reach of children     AWQ 105 PRO User Manual       Features  amp  Advantages                                        i     5 outputs  including an output exclusively for the use of search stimulation probe for point  detection and immediate stimulation    Frequency and Pulse Width are adjustable  amp  separated into two groups  Group 1 for Ch  1 amp 2   and Group 2 for Ch 3  amp  4   Instead of one Frequency        one Pulse Width for all  channels   2 large LCD  each measures 15X30 mm  for displaying precise frequency of each group   and one LCD  15x30 mm  fo
16. plied to the skin  the electrical resistance measured by the device effectively  becomes lower and the device will behave as though an acupuncture point was found   When the probe touches an acupuncture point the buzzer will buzz  the LED of the    ADP     will flash continuously at the same time   the digital display will show a higher number and a  very light electric stimulus may be felt by the patient  Since an acupuncture point is very  small  it should be located with patience and care     If the electrical resistance of the general surface of the skin is low  or when the skin is wet or  sweating  which would lower the skin resistance  the buzzer would give a sound signal on    17    AWQ 105 PRO User Manual       the skin surface wherever the probe touches  When this happens  dry the skin with a towel   maneuver the probe with lighter pressure  and readjust the sensitivity setting to a lower level  so that the point to be located can be discriminated from the surrounding areas of the skin   There is no definite standard for the adjusting the sensitivity of the device and how much  pressure to apply to the skin surface  the appropriate sensitivity will be found through    experience     WARNING   Never use the probe on open cuts or wounds     If the located point is to be stimulated by the probe tip  make sure the probe tip is touching  the located point  and press the search to treat button on the probe  adjusting the intensity  setting of STIM INT Channel will increase
17. r has been damaged in any manner     There is generally no restricted    shelf life    of the device     Environmental condition                            Temperature Humidity Pressure  10  C to 40  C 30 75  RH  During Use   700 1060 hPa   50  F to 104  F  non condensing  10  C to 50  C 15 95  RH  Storage 700 1060 hPa   50  F to 122  F  non condensing    10  C to 50  C 15 95  RH  Transportation    700 1060          50  F to 122    non condensing  Cleaning    DO NOT IMMERSE THE STIMULATOR IN ANY CLEANING SOLUTION     The stimulator should be periodically wiped clean using a damp cloth and a solution of mild    soap and water  Use of other cleaning solutions may damage the housing     The wires should be wiped clean with a cloth dampened with a mild soap solution and then    wiped dry        AWQ 105 PRO User Manual       Limited Warranty    This warranty is in lieu of any other warranty expressed or implied    This AWQ 105 PRO ACUPUNCTURE STIMULATOR   T E N S  is warranted to the initial  purchase      purchases     and to no other person against any defects in material and  workmanship for a period of one year from the date of purchase  If the stimulator is found to  be defective within the warranty period  it will be repaired or replaced if returned prepaid to  an authorized service center  This warranty does not cover damage caused by rental   misuse  negligence  accident  abuse  alteration  or modification of the device  Repairs after  the warranty period will be made and 
18. r showing sensitivity during acup point detection  This LCD  also displays the frequency  fixed at 10 Hz  during direct stimulation by the  search stimulation probe   3 different Mode  Cont  continuous   Modulate and Burst    High  amp  Low output levels for selection    X1 and X5  multiplier  of pulse rate and width for adjustments   Timer selection for different period of treatment session  Continuous  15 minutes and 30  minutes   Buzzer ON OFF  for sound control during point detection     Music for timer alert and error warning     The Search   Stim Probe includes a Search to treat push button selector  which when    depressed allows immediate stimulation on a point right after its location is found        Search to treat push butt  n                  in Search to treat mode    il APD in Search mode    AWQ 105 PRO User Manual       Improved design of accessories  CE marked plug connecting wires  4 assorted colors   with pin leads so that each can be fitted to alligator clip adaptors or different types of  needle connectors such as Grasping clips  duck beak clips  micro hook clips or crocodile    clips  A large range of optional accessories is available     ii  Optional accessories       Fa      Se N Pa                  N                                                        2      N 4 N                   NG 7   f  0087                    A                    Crocodile Clip Duck Beak Clip Grasp Clip Micro Hook Clip       iii  Alligator clip wires which provide very sturdy 
19. ry compartment for easy and proper insertion of batteries     11    AWQ 105 PRO User Manual       Indications and Controls    AWQ 105 PRO    30 MIN       12    AWQ 105 PRO User Manual       AWQ 105 PRO  Peat    Tha Pet ef                                  190 whe                                           99 em ine                                              21       AWQ 105 PRO User Manual       Operation of Controls                                                             No   Descriptions Functions   1 Model Name AWQ 105 PRO   2 Power ON OFF switch Turns the power ON or OFF    3 BUZZER ON OFF switch  Turns the buzzer sound during point detection ON or OFF    4 HI   LOW switch For selection of HI range or LOW range output intensity    5 ERROR LED When turn ON the unit  if all channels setting do not reset to OFF output   Red LED lights up  amp  music sounds  The unit resumes work after reset all  channels to OFF position    6 LOW BATTERY LED When the battery voltage drops to under 7 volts  this LED will illuminate  indicating that new batteries need to be installed    7 Mode selection switch To select different modes of waveform  CONT   continuous   MODULATE   dense disperse  and BURST  Intermittent     8 Mode indication LED The selected waveform mode LED will illuminate indicating which  waveform is currently active    9 Frequency Adjustable Turn clockwise  increase  or anticlockwise  decrease  to adjust the   knob for Ch1  amp  Ch2 frequency  pulse rate  of Ch1  amp  Ch
20. set pulse rate and width  ON  3 seconds   OFF  3 seconds     Pulse Width range at different Pulse Rate settings              x1 x5  Pulse Rate 1 100 Hz 5 500 Hz  Pulse Width 50 500 US 10 100 uS                AWQ 105 PRO User Manual       Introduction    AWQ 105 PRO ACUPUNCTURE STIMULATOR            5  is a professional  brand new unit  with 5 channels  It comes up with a modern design and inherits the features of AWQ series  acupunctoscope  This professional unit provides multiple functions and features  built in with  5 outputs channels  and with separated groups for adjusting frequency and pulse width  The  acupuncture point detection is with sensitivity control and the Search  Stim Probe includes a  Search to treat push button selector  which when depressed allows immediate stimulation    on a point right after its location is found     2 large LCD  each measures 15X30 mm  for displaying precise frequency of each group   and one LCD  15x30 mm  for showing sensitivity during acup point detection and the  frequency during direct stimulation  It provides 3 different Mode  Cont  continuous      Modulate and Burst  and a High Low selection of output     Lastly  a timer is equipped for selection of different period of treatment session  and a    Buzzer ON OFF control  for shutting down the sound during point detection     Indication and Its Intended Purpose    The AWQ 105 PRO ACUPUNCTURE STIMULATOR   T E N S  is intended to use in  applying electronic stimulation to acupuncture
21. te and width  lt ON gt  3 seconds      lt OFF gt  3 seconds  both pulse rate  amp     width are adjustable        AWQ 105 PRO User Manual       Timer  Display  Low battery lamp    Power supply    DC Power Jack  Output socket  Error LED    Weight  Size    Accessories    Cont   15 min  30 min   3 LCD  each measure 15x30 mm   The LED lights when voltage drops to 7V   C type  LR 14  batteries x 6 pcs Or   DC 9V 500mA adaptor  optional     Use correct adaptor comply with standard and spec    6 3mm x 2mm centre pin    1 5mm diameter socket    Red LED lights up  amp  music sounds when turn ON  the unit without reset all previous channels setting to  zero output  The unit resumes work after reset all  channels to zero position    726g  main unit only    255 x 175 x 75  mm   main unit only   Search stimulation probe with handgrip electrode  Connecting wire  4 assorted colors           4 pcs   Pin lead to duck beak clip adaptor 4 pairs     Instruction manual 1 pc     AWQ 105 PRO User Manual       Wave Form Pictures    FC  A  CONTINUOUS       Pulse Rate   FC   Continuous Frequency    Pulse Width range at different Pulse Rate settings             x1 x5  Pulse Rate 1 100 Hz 5 500 Hz  Pulse Width 50 500 uS 10 100   5                             Preset pulse rate and width ramp up and down for 6 seconds per one cycle     Pulse Width range at different Pulse Rate settings                          X1 x5  Pulse Rate 1 100 Hz 5 500 Hz  Pulse Width 50 500 uS 10 100 uS  C  BURST       J Hb    Pre
22. urns with  increasing sensitivity  during location of acupuncture point    19  Timer switch Select the timer duration for 15  30 minutes or continuously    20  Search Stimulation probe  This jack is used for attaching the search stim probe to the device    insertion jack  socket    21  Output jacks  socket  For insertion of output connecting wires    22  Output Intensity control  Rotating the knob clockwise will first turn      the output channel and then  knob increase the current output   or vise versa    23    1 X5 switch X1 X5 multiplier switch   to select the frequency and pulse width of the   output in normal range of frequency at 1   100 Hz   pulse width at 50 500     S  or multiplies 5         5   500 Hz   frequency   and 10 100 yw S  pulse  width    24  Battery compartment door The battery compartment door can be removed to expose the battery  compartment  The device uses 6 pcs  of 1 5 V    C    type  LR14 batteries    25  DC 9V Input This input can be used to plug in an external 9V 500mA input source    26  Output Intensity control  Output Intensity control knob is applied only at    APD  amp  STIM mode     when  knob for search   stim operating stimulation at    APD  amp  STIM mode     rotating the knob clockwise  probe turns on the output channel and then increase the current output intensity    or vise versa  of the search   stim probe   27  Output Intensity LED When turning clockwise output intensity knob at    ON    position  output       Lights       intensity
23. with new batteries    The device will provide sufficient levels of stimulation only if the batteries are properly  installed    To avoid battery leakage  remove the batteries if the device will not be used for an extended    period of time     To ensure the device works properly  please check the device on a periodic basis with the                      following   PARTICULARS DESCRIPTIONS PROCEDURES  Appearance    check for broken or damaged parts  By visual inspection  Il  check all LCD displays  make sure all digits are legible   Operation I  check all LEDs light when device is turned on  By operating the      check that the buzzer sounds  device  Ill  check that the device functions properly   Accessories    check for broken      damaged parts of all accessories By visual inspection  including the search stim probe   Il  check all connecting wires for any broken or damaged  parts   Safely   Turn on one of the intensity knobs  press POWER By operating the  precaution SWITCH ON so an error occurs  Verify that the device  device  resets to normal operation when turn OFF all intensity  knobs  no error light  no music to be function                 23    AWQ 105 PRO User Manual       Trouble Shooting    If your device appears to be functioning improperly  check the procedures shown below to    determine what may be wrong     If none of these measures correct the problem  the device should be serviced   Do not attempt to repair the device by yourself  Return the device to your l
    