MT6000/8000iE SERIES INSTALLATION INSTRUCTION

image

Contents

1. An internal fuse will prevent damage if the polarity of the DC power is incorrect Check wiring for proper connections and try to power up again HIGH VOLTAGE An Internal fuse will prevent damage for overcurrent condition however it isn t guaranteed DC voltage sources should provide proper isolation from main AC power and similar hazards EMERGENCY STOP A Hard wired EMERGENCY STOP should be fitted in any system using HMI to com ply with ICS Safety Recommendations SUPPLY VOLTAGE CONDITION Do not power the HMI and inductive DC loads or input circuitry to the controller with the same power supply Note The 24 V dc Output from some controllers may not have enough current to power the HMI WIRE ROUTING a Power wire length should be minimized max 500 m shielded 300 m unshielded b Please use twisted pair cables for power wire and signal wire and conform to the impedance matching c If wiring is to be exposed to lightning or surges use appropriate surge suppression devices d Keep AC high energy and rapidly switching DC power wiring separated from signal wires e Add a resistor and capacitor in the parallel connection between the ungrounded DC power supply and the frame ground This provides a path for static and high frequency dissipation Typical values to use are 1M Ohm and 4 700 pF
2. INGS Launch EasyBuilder Pro software select your project file press F7 shortcut key to open the download dialog box Select Ethernet gt IP tab gt Enter your HMI IP gt Click Download to download this project file to HMI If use MT6O070iE please select USB cable please refer to EasyBuilder Pro User Manual for software operation details 7 COMMUNICATION CONNECTIONS Note 1 COM1 and COM3 RS485 2 W support MPI 187 5K please use one at one time 2 COM1 RS485 COMS3 RS485 with isolation protection N A for MT6070iE COM1 RS232 9 Pin Male D sub 12345 6789 es T Ground ce Nes COM1 3 RS485 9 Pin Female D sub 54 21 O76 jem ome rae ee RS485 a e eje o w oe e o e Je e e E o oe oe o o ower ce oo cons 8 DIP SW SETTINGS ABOG l g 3 swi swe swe swa mos Touch screen calibration mode Note Make sure that all local and national electrical standards are met when installing the unit Contact your local authorities to determine which codes apply POWER CAUTION The HMI can be powered by DC power only voltage range 24 20 Volts DC compatible with most controller DC systems The power conditioning circuitry inside the unit is accomplished by a switching power supply The peak starting current can be as high as 2 A FUSING REQUIREMENTS If the display does not come on within 5 seconds of power up remove power
3. Weg 1 INSTALLATION AND STARTUP GUIDE Read these instructions carefully before installing operating or perform maintenance in this equipment This document covers the installation of MT6000 8000iE Series HMI for the detailed specifications and operation please refer to brochure and EasyBuilder Pro user manual Install environment MT6000 8000iE Series HMI is paua GHG NEMA 4 rated indoor only The MT6000 8000iE Series has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Electrical environment 1 Make sure that the displays are installed correctly and that the operating limits are followed Avoid installing units in environments where severe mechanical vibration or shocks are present 2 Do not operate the unit in areas subject to explosion hazards due to flammable gases vapors or dusts 3 Do not install the unit where acid gas such as SO exists 4 This device should be mounted in the vertical position and for use on the flat surface enclosure 5 Conform to UL 508 ISBN 0 7629 0404 6 machi ne safety for use in Pollution Degree 2 Environment Environmental considerations MT6000 8000iE SERIES INSTALLATION INSTRUCTION 2 UNPACKING THE UNIT Unpack and check the delivery If dam
4. age is found notify the supplier 1 Installation instruction 2 sided A4 1 2 Human machine interface 1 3 Power connector 1 4 Brackets amp screws 1 pack 5 USB stick clamp amp tying strap 1 6 Fuse 1 25 A 250 V 5 20mm 1 Note Place the operator panel on a stable surface during installation Dropping it or letting it fall may cause damage 3 INSTALLATION INSTRUCTIONS Secure the operator panel in position using all the fastening holes and the provided brackets and screws A a Cutout MT8100iE 260 202 3 1 USB Stick Clamp Usage Combining the USB stick with the clamp and the tying strap can prevent USB stick from disconnecting with HMI when strong vibration is present 1 Insert the USB connector to the clamp and tie them together with the tying strap 2 Press the spring and insert the USB stick into HMI Note 1 Connect positive DC line to the terminal and the DC ground to the terminal 2 Please do not connect HMI with PLC and PC simultaneously to prevent potential difference from destroying USB ports of HMI and PC 5 SYSTEM SETTINGS When HMI is powered up and displays image click the system setting button default system pass word 111111 It is necessary to connect the HMI to your network through a RJ45 cable N A for MT6070iE Go to the Network tab you may choose to auto get DHCP IP or designate your own IP 6 EASYBUILDER PRO SOFTWARE SETT

Download Pdf Manuals

image

Related Search

Related Contents

  Phono Module  September 1960  Pyle Digital Multimeter  Resumo - Chasqueweb  ADC Read Software User Manual  自家発電装置  CVM-96 SERIES INSTRUCTION MANUAL  Programa para monitoreo a distancia y control de NPBC-V3M    

Copyright © All rights reserved.
Failed to retrieve file