image

Contents

1. UPS SYSTEMS P O Box 1986 Walnut CA91788 U S A Tel 1 888 MARUSON E mail Custsrv MarusonUSA com Please visit our website www MarusonUSA com click on Warranty Registration to register your Maruson UPS products Tower Series UPS TOW 600 TOW 800US TOW 1000US Thank you for purchasing Maruson Tower Series UPS products Please read the USER S MANUAL before using the Tower Series UPS product The Tower Series UPS will protect your computer hardware from physical damage and will provide emergency battery backup power to prevent data loss in the event of power problem Save the original carton and styrofoam inserts If you require service your warranty may be voided if the Tower Series UPS Is sent back to Maruson without proper packaging The main features include e Advanced equipment amp data protection from blackouts brownouts sags AC line noise and surges e Full analytical high performance micro processor control with true RMS synchronous calculation e Intelligent battery management for battery status battery power saving amp battery replacement control e DC direct starts up capability complete diagnostic indication and control e Built in USB communication port on 800VA 1000VA only e RJ45 jack for LAN surge Protection for 800AV 1000VA Operation amp Installation The Tower Series UPS can protect your equipment from all power problems such as surge spikes blackouts brownouts
2. 5AHx1 12V 7AH x 1 12V 9AH x 1 Short Circuit Protection 32 F 104 F 0 C 40 C 0 to 95 non condensing 45 F 113 F 15 C 45 C Dimensions WxDxH inch 6 1 4 3x8 3 7 1x6x9 5 7 1x6x9 5 Specification may change without notice Troubleshooting The UPS will not UPS is not turn on Switch on the On Off switch If the power is not present please make sure your circuit breaker on the building is not accidentally turned off Reduce the amount of equipment plugged into the Battery Backup amp Surge Protection outlets of the UPS Next rest the circuit breaker by pushing it back in The Battery Backup Turn of the UPS and reduce the amp Surge Protection amount of equipment connected to outlets are overload these outlets Due to age the Removed all connected equipments battery does not hold from the UPS and charge the battery a full charge at least 8 hours Return for service or you can replace the battery by ordering one at www MarusonUSA com The Battery Backup Refer to the Indicator Table Tower amp Surge Protection UPS is making a continuous sound outlets are overload and the Overload indicator is light The UPS has The Tower UPS will turn off when the Power the UPS exhausted its battery has been depleted during the available run time failure of utility power Allow UPS to re charge before continuing using of Ensure the equipment that you want to stay powered du
3. LED light is illuminated turn on your connected equipments Indicators 1 On Off Switch This On Off switch controls the power to your equipment and performs self test to detect inverter line battery status amp LEDs NOTE Turn on the UPS Press and hold the switch in for more than one second and release after the beep is presented The UPS will be started In addition the UPS will turn on automatically when you plug the UPS into the wall outlets and utility power is present NOTE Turn off the UPS Press and hold the switch in for more than one second and release after the beep is presented The UPS will be shut down completely NOTE Perform Self testing The UPS will perform self testing for about 5 seconds when the UPS is turned on 2 Line Battery LED Green LED Indicates the UPS is providing AC power to your equipment When the LED is blinking the UPS is providing power from battery 3 Warning LED Red When in AC or DC mode the blinking LED could indicate that the battery should be replaced When the LED is always on it indicates an overload condition or UPS fault For details please see indicator Table 4 Battery Backup amp Surge Protection Outlets These outlets not only provide full time surge protection but also provide emergency battery backup power 5 Surge Protection Outlets Bypass Outlets These outlets provide full time protection from surge and spike 6 LAN Internet Surge Protect
4. and line noise When AC power is present and the ON OFF switch is turned on the Tower Series UPS is constantly charging the battery and providing the power to the equipment from AC line directly The reliable battery can provide enough stable power to complete your work save the data and safely shut down your system in the event of a blackout The Tower Series UPS is simple to operate and install The following are the steps of installation prior to connecting the equipment to the UPS 1 Connect the Power Office UPS to grounded AC power Outlets 2 Charge the battery at least 8 hours for fully charge before you turn on the ON OFF switch The ON OFF switch does not have to be on 3 Plug your computer and monitor into the Battery Backup amp Surge Protection outlets These outlets will provide emergency battery backup power during power problems as well as surge protection from surge and spike CAUTION Do NOT plug LASER PRINTERS into any of the Battery Backup amp Surge Protection or Surge Protection outlets CAUTION Do NOT plug ACCESSORY SURGE strip into any of the Battery Back amp Surge Protection outlets Plug your peripheral equipment printer scanner fax speaker etc into the Surge Protection outlets These outlets will NOT provide battery backup power during a utility power failure 5 With your equipment turn off switch on the Power Office UPS product 6 When the On Line
5. ion Built in RJ11 RJ45 jacks protect Internet and Networks from surges Note The UPS will operate normally without this connection 7 USB Communication Port The built in USB port connects to your computer The software will shut down your computer automatically in case of power failure It prevents the possibility if damaging your files with abrupt power outage The software can also provide the information regarding the status of your utility power line 8 Circuit Breaker The button will protrude when the overload condition occurs The UPS will switch off of utility power If the button protrudes disconnect some non essential equipment and reset the circuit breaker by pushing the button inward 9 AC inlet Please plug the AC power cord into this connector Safety Instructions Once you have received the Tower Series UPS product you should remove and inspect the product for shipping damage If any damage is found please notify the carrier and your dealer You will need to keep the shipping carton and the packing foam in case the product must be returned to the factory for service SAFETY INSTRUCTIONS 1 Place the Tower Series UPS indoors in an area that has adequate airflow and is free of excessive dust Do NOT allow the UPS to be exposed to moisture rain excessive heat or direct sunlight 2 Use of the Tower Series UPS product for life support applications where failure of this equipment can reasonably be expected to cau
6. ring a failure of utility power is plugged into the Battery Backup amp Surge Protection outlets faulty further troubleshooting Recycling Information Your UPS contains Non Spill Sealed Lead Batteries On the battery you will find the battery name Please reference the chart below for recycling information Other brand s of battery please contact Maruson Technology Corp If outside the USA or Canada please contact your local authorized distributor Battery Name Recycling inside the USA Vision Battery 1 877 730 2877 First Power Battery 1 877 730 2877 BB Battery 1 800 278 8599
7. se failure to life support equipment or to significantly affect its safety or effectiveness is NOT recommended 3 Please always disconnect the input power cord from the wall outlet before replacing the battery 4 Do NOT dispose of battery in a fire The battery may explode 5 Do NOT open or mutilate the battery They contain an electrolyte that is toxic and harmful to the skin and eyes 6 Proper disposal of battery is required Please refer to your local laws regulations regarding to battery disposal 7 Use tools with insulated handles to replace the battery to avoid personal injury Due to energy hazard please remove wrist watches and jewelry such as rings when replacing battery Indication Table Green LED Red LED Alarm eros Indication AC X X oom fox a Mode Operation On ae 4 beeps 0 25 sec per 10 sec X O O Oox on fon DC Mode On Short DC Mode 4 2 DCM Blinking X beeps 0 25 C ace sec per 10 sec Operation Low Battery Blinki 1b 1 h M abnormal Specification i aa E Capacity leoovasoow _g00VA 400w __ 1000VA S00W 120V 15 20 220V 20 26 120V 12 Self test Mode Over Load 110 DC Mode Over Load 120 Input Voltage Range Output Voltage Range Outlets 6 Outlets 3 Battery Backup amp Surge Lighting Surge Protection 480 Joules Transfer Time to Battery AC 4 ms typical Battery Type Sealed and leak proof maintenance free lead acid battery Battery Specification 12V

Download Pdf Manuals

image

Related Search

Related Contents

SERVO VENTILATOR 300/300A OPERATING  TAFCO WINDOWS NU2-227V-I Installation Guide  Strumenti uten - Firmware Center  Samsung MT1099STD دليل المستخدم  自転車への気遣いは安心安全への第一歩!  Sunbeam Bedding SFH107-SFH108UM User's Manual  Flash externo TTL para Canon™  河川用ゲート設備 点検・整備・更新検討マニュアル(案)  Manual de Uso  Global Direct 28456 Instructions / Assembly  