1. central unit Registration switch 12V for detector Input for detector 12V for detector Input for detector QO TNC GND for detector temp sensor Output reay 16a O c Peona ra AN gt NO GND for antenna 230V N 230V AC power supply lt 230V L i ad Q LLI a Fig 1 Connection terminals of EGR 1 AMN AAN Wagy SIOM Please leave this guide with the end user ao INSTALLATION Power supply EGR 1 is to be installed into a fuse box or other electrically safe place Use either 230 VAC orange terminals or 12 V DC black terminals as power supply but not both at the same time Adjust the protection lid over the 230V terminal strips once all connections are made Antenna The radio antenna is stripped along 16 cm on one end which must stick vertically out of the fuse box Connect the central lead wire to the ANT terminal and the other one to GND cf Fig 2 Thin 16 cm long portion of the antenna cable that is to hang vertically outside of the fuse box Fig 2 Installation of antenna Temperature sensor If thermostatic regulation or temperature reading is required connect a temperature sensor to inputs T1 and GND The temperature sensor cable must not be laid out alongside 230V leads and should be kept as far away as possible from any sources of electrical interferences Thermostatic regulation and temperature reading may otherwise be perturbed The temperature sensor shoul
2. SIOM Please leave this guide with the end user EGR 1 Radio controlled relay module Installation and user manual TECHNICAL SPECIFICATIONS Manufacturer Sikom AS Norway Type Model EGR 1 300 8307V10 Power supply 230VAC 25mA or 12V DC 150mA Max load on output relay 16A resistive Room sensor 10K NTC at 25 C Operating temperature 20 C to 50 C Temperature sensing 28 C to 49 C 2 C Compatible with GSM ECO Starter EcoStarter Touch series Radio frequency 433 9 MHz Dimensions LxHxD 55x90x59 mm 3 DIN modules Weight 170g EGR 1 is designed for indoor use only PACKAGE CONTENTS e EGR 1 e Antenna e Protection lid DESCRIPTION EGR 1 is a fuse box module that offers one relay for switching electric circuits on and off EGR 1 offers 3 inputs of which 2 can be used simultaneously One input is for a temperature sensor and the 2 other are for any kind of detector fire flooding gas burglary motion detector or magnet contacts EGR 1 offers a thermostatic regulation function which is only available if a temperature sensor is connected to input T1 The user can then enter desired eco comfort temperatures into the system to obtain a programmable thermostat which can easily be toggled between eco and comfort temperatures OPERATION EGR 1 is operated either by SMS messages sent to the central unit or directly from the central unit For further information please refer to the user manual of the relevant
3. d therefore not be used as a floor sensor for floor heating installations as this would require shielded twisted pair sensors and filters Similarly whereas it is possible to extend a temperature sensor it would also induce a loss of precision of measurements Output relay The potential free relay is for controlling other appliances it supports a load of 16 A It offers thermostatic regulation and on off control NB When using a 230 VAC power supply the voltage applied at the relay must also be 230 VAC Conversely a power supply of 12V DC limits the use of the relay to extra low voltages 12V DC or less Add auxiliary relays or contactors when necessary NO Normally Open C Common NC Normally Closed Connected 7A NO C NC Fig 3 Relay contacts in the inactive state i SI OM Please leave this guide with the end user Detector inputs EGR 1 has 3 inputs but only 2 inputs may be used at the same time either S1 and S2 or T1 and S2 T1 is exclusively for a temperature sensor if needed S1 and S2 are inputs for detectors Possible combinations e Temperature sensor in Ti and detector in S2 e Detector in Si and detector in S2 Connect the detection loop of the detector to input terminals S1 or S2 and GND A resistor inside each detector tells EGR 1 about the type of the detector The recognized values are the following 10K PIR 12K Fire 15K Water 18K Magnet 22K Gas 27K other type
4. s 33K generic burglary Such a resistor is built into all detectors sold by Sikom For other detectors mount a suitable resistor in series with the detector if the detector is of type NC Normally Connected and mount the resistor in parallel with the detector if it is of type NO Normally Open REGISTRATION WITH THE CENTRAL UNIT 1 Go to the setup then the device registration screen If needed please refer to the registration procedure in the user manual of the central unit Press then the SW button of EGR 1 for at least 5 seconds On the screen of the central unit enter the name to be given to the device The message Registration OK will then be shown on the display of the central unit as well as the 2 digit registration number assigned to this EGR 1 module Please write down this number for the end user as it is required for remote control PE IMPORTANT INFORMATION REGARDING FROST PROTECTION The thermostatic regulation offered by Sikom devices may be used to maintain a base eco temperature in your premises but must not be taken as an infallible frost protection Indeed any electronic equipment is vulnerable to power surges and other perturbations that may come from the electricity network e g due to lightning In such an event if the electronics is damaged it may no longer ensure the thermostatic regulation and hence the frost protection Therefore if frost protection is a critical requirement
5. such as around water pipes it is recommended to add a security mechanism These are some alternatives e Use an additional heating system with its own thermostat to ensure frost protection in critical premises e Install a protection against power surges and other perturbations from the electricity network e Set up a bimetal thermostat in parallel with your Sikom unit Sikom and its representatives will not assume liability for any damage due to frost AMAN ANY Waay SIOM Please leave this guide with the end user _ COMPLIANCE WITH INTERNATIONAL REGULATIONS This equipment complies with the European R amp TTE directive Further information may be obtained by contacting either www EcoStarter com or the manufacturer Sikom AS www sikom no Neptunveien 6 7650 Verdal Norway WARRANTY Sikom A S products are covered by a two years warranty against any faults due to material flaws or manufacturing errors which limit or render useless certain functions described for the product The warranty requires the customer to present the original bill with date of purchase and type of equipment clearly readable What is covered by the warranty During the warranty period Sikom A S reserves the right to repair the product or to replace defective parts with functionally equivalent parts If after several attempts Sikom A S is unable to correct the problem and the product does not work as described in the manual Sikom may elect
6. to refund the purchase price or to replace the product with a functionally equivalent one All replaced parts and products become the property of Sikom A S What is not covered by the warranty Indirect damage to life health property revenue and environment caused by circuits and appliances connected to the units install and use this product responsibly Costs related to re installing transporting and dismantling units recycling may be governed by special rules see the relevant chapter Damages caused by use outside of the operating conditions specified in the manual Malfunctions caused by transport damages Any unauthorized repair modification or disassembly Use of non original parts External factors such as lightning power supply issues mobile network issues flood damage or fire Units with modified removed or unreadable serial number Sikom assumes no responsibility for any errors that may appear in this manual Information contained herein is subject to change without notice RECYCLING INFORMATION Waste Electrical and Electronic Equipment WEEE Symbol The WEEE Waste Electrical and Electronic Equipment symbol indicates that this product must not be disposed of along with other household waste It is the customer s responsibility to dispose of the product properly by taking it to a designated site for recycling To locate a recycling disposal site near you contact your local city recycling program your regular
7. waste disposal service or the agent from whom you purchased this product For Switzerland this product includes in its purchase price a contribution the advanced recycling fee to the SWICO Recycling Warranty which means that used equipment can be handed in free of charge for recycling Collection sites are listed at http www swicorecycling ch
Download Pdf Manuals
Related Search
Related Contents
Sonic Alert 6021 Clock User Manual User Manual 2013 Scheme: struttura del programma e campo di azione Victor Technology 1776 calculator MS-13-214 - Swagelok Samsung 244T Priručnik za korisnike manuale 50x AVTech Faça o do Manual do Medidor de Dureza de Grãos GRS-358 (PDF 8.54 MB) NASCAR NDE 4720V User's Manual Copyright © All rights reserved.