Home

URC Manual Rev3e

image

Contents

1. ack to the normal operating display mode The MCC and AC In Current Limit levels will be stored in internal memory and remains the setpoint until it is changed again using this menu In the top right area of the display you can see a small battery icon which represents the charging state of the battery This state is directly linked to the charge status bar on the battery charger itself 7 URC setup When the rotary controller knob 3 is pressed for three seconds the following screen will appear Remote Control Setup By turning the rotary controller you can select the Remote Control Setup option and press the rotary controller once The following screen with URC properties will appear Return Keypress Beep Alarm Beep Backlight Brightness LOO Contrast Now you can select the property that you wish to change by turning and pressing the rotary controller accordingly A screen will appear that allows you to change the property value by turning rotary controller again The image below shows the display contrast property as an example LEO Contrast E o p The desired value can be stored by pressing the rotary controller for three seconds This way of saving a property value change would result in jumping back to the normal operating display mode again When you wish to change more than one property press the rotary controller once and you will jump back to the URC properties list again were you can select the
2. arning and caution statements before installing and using the URC 2 Installation Never connect a TBSLink connector to other network types like ethernet or to the e xpert series quick connection kit CAUTION Before removing the connection compartment panel of your device make sure to disconnect the battery and unplug all AC sources first Then leave the power switch warninc in position I for at least 10 seconds The URC must be mounted in a dry location where it is not exposed to direct sunlight The ambient air temperature of this location should be between 10 C and 50 C humidity lt 95 non condensing Never put excessive pressing force on the display window area since this could permanently damage the display For panel mounting the URC the following measurements must be taken into account 118mm 113mm cutout area 61mm 58mm Pi mounting screw hole Please follow the installation instructions of your TBS device to connect the URC correctly The URC must be connected inside the connection compartment of a TBS inverter or combi while it can be connected externally bottom panel to a TBS battery charger 3 URC Display and control overview Now that the URC is connected to the TBS device you can turn it on which will automatically activate the remote panel as well Before going into specific details the image below shows the display and control overview of the URC 1 2 BA tbs lectroni
3. cs 8 amp sisoo 24 i Eson select gt OC In Current enter menu AC Out Voltage AC Out Current universal reinote control 6 5 4 1 TBS device mode indicator With an inverter connected symbol I indicates inverter on in normal mode Symbol II indicates inverter on in ASB mode With a charger connected symbol I indicates charger on in normal mode Symbol II indicates charger on in forced float mode With a combi connected symbol I indicates combi on in normal mode Symbol II indicates combi on in charger only mode 2 TBS device type indicator Automatically shows which inverter charger or combi model is connected to the URC 3 Intelligent rotary controller knob Three way control knob which can be used to select values browse through lists and change numeric values 4 Backlight button Activates or deactivates the backlight of the LCD 5 LCD parameter field In normal operating conditions this field indicates all available parameters and it s corresponding values When this list has more than four rows you can use the rotary controller to browse through this list 6 Power button This button activates the power options menu or directly turns off the TBS device when pressed for 3 seconds 7 Alarm indicator LED Flashes red when a TBS device error has occurred The corresponding error type will be showed on the display 8 Power indicator LED Lits green when the TBS device and remote panel are on 4 Genera
4. i CD tbs electronics Universal Remote Control TBSLink for Powersine PS1000 1800 inverter series Omnicharge OC20 60 charger series Powersine Combi PSC 1600 1800 combi series CN Thank you for purchasing the TBS Electronics Universal Remote Control Please read this owner s manual for information about using the product correctly and safely Keep this owner s manual close to the device for future reference Owner s manual TBS ELECTRONICS BV De Marowijne 3 1689AR Zwaag The Netherlands http www tbs electronics com 1 Introduction Thank you for purchasing the TBS Electronics Universal Remote Control URC for controlling the following TBS devices Powersine PS1000 1800 inverter series Omnicharge OC20 60 battery charger series Powersine Combi PSC1600 1800 inverter charger combi series The URC features an advanced graphical display and a smart user interface for easy operation Using the URC you can readout all available parameters of the connected TBS device and remotely turn this product on and off The communication between the URC and the TBS device is made using the rugged industrial TBSLink protocol which supports wirelengths of up to 50 meters A TBSLink connection accepts simple CAT5 Ethernet patch cables straight wired To get optimal performance and safe operation from your URC and TBS device it must be installed and used properly Please read this manual very carefully especially the w
5. l URC functionality As explained above when the TBS device is switched on using it s main power switch the URC will start up as well showing a green power LED and the following startup screen for a few seconds Universal Remote Control B M2011 TES Electronics BY This screen will be followed by the normal operating display mode where all available parameters of the inverter charger or combi will be showed H FS1800 24 H FSCi600 i2 60 im OC In Voltage Charge Stage Battery voltage 14 30 OC Out Voltage Battery Current 40 A OC Out Current Battery Temp 2 0 C OC Out Current Charge Stage Absorption DC In Current AC Out Voltage AC Out Current Q 3 You can browse through the list of available parameters by turning the rotary controller knob 3 clockwise or counter clockwise When the ambient light conditions are poor the backlight button 4 can be pressed to activate the display backlight Use the same button to deactivate the backlight again When the TBS device shuts down automatically caused by tripping an error mode the alarm LED 7 starts flashing and the display will show the corresponding error type This error message will automatically disappear again when the error has been solved To turn off the TBS device or to put it into a different operating mode you can press the power button 6 once This will show the inverter charger or combi power options menu Switch to Standby mode Switch to Forced fl
6. n the battery charger itself 6 Combi only URC functionality When the URC is connected to a combi device it is possible to dynamically reduce the Maximum Charging Current MCC and set the AC input current limit level Reducing the MCC is ideal in situations where the user wishes to temporarily reduce the chargers AC power consumption for example when limited AC source power is available To activate the MCC menu press the rotary controller knob 3 once which will show the following screen H FSC1600 12 60 E wos Moas Charge Current 45 Al By turning the rotary controller knob 3 the preferred charge current can be set in percentage of maximum rated charge current or just in Amps When the rotary controller knob 3 is pressed once again the AC In Current Limit level screen appears H FScC1600 12 60 i AC In Current Limit By turning the rotary controller knob 3 the preferred AC input current limit level can be set in Amps When this input current level is exceeded the combi immediately reduces the charge current automatically in order to keep the AC input current below this predefined level When this input current level remains being exceeded even when the charge current has been reduced to zero the Power Boost feature will be activated see Powersine Combi combi manual for further information When the desired AC In Current Limit level is selected press the rotary controller knob 3 once to jump b
7. next property to change When all desired URC properties are changed select and press Return in the URC property list screen which will save all changed values and jump back to the normal operating display mode If no buttons are touched for 90 seconds when operating in a setup screen the URC will automatically jump back to the normal operating display again without saving any changed property values 8 Technical specifications Parameter Universal Remote Control TBSLink Databus type TBSLink point to point Connection cable type UTP straight wired patch cable RJ45 8 RJ45 8 Nominal operating voltages 12VDC or 24VDC Power consumption BL on 12mA 47mA Operating temperature range 10C to 50 C Storage temperature range 20C to 65 C Enclosure body size Ixhxw 130 x 70 x 36 mm Needed panel cutout Ixh 113 x 61mm Maximum mounting depth 30 mm Protection class IP30 Total weight 140 grams Housing material ABS Note the given specifications are subject to change without notice URC Manual Rev3e Printed in The Netherlands
8. oat Switch to Standby mode Switch to Charger only Switch to Standby mode Switch to ASB mode By turning the rotary controller knob you can choose your preferred option This option can be executed by pushing the rotary controller knob or pressing the power button Option Return will escape from this screen and jumps to the normal operating screen again Changing to a different TBS device operating mode will also change the mode indicator 1 from I to II or vice versa If an inverter was already running in ASB mode before entering the power options menu the Switch to ASB mode option is replaced by Switch to normal mode If a charger was already running in Forced float mode before entering the power options menu the Switch to Forced float mode option is replaced by Switch to normal mode If a combi was already running in Charger only mode before entering the power options menu the Switch to Charger only option is replaced by Switch to normal mode The choice of operating mode on the URC will always override the position of the main power switch on the inverter You can also switch directly to TBS device standby mode in the normal operating screen by pressing the power button 6 for three seconds The TBS device and URC can be activated again by pressing the power button 6 once Note In standby or sleep mode the device still draws a very small current from the battery in order to be able to de
9. tect a power button press on the remote panel When you are leaving the device off for an extended amount of time it is advised to turn off the device using the local main power switch This way the device will draw zero current from the batteries 5 Charger only URC functionality When the URC is connected to a battery charger it is possible to dynamically reduce the Maximum Charging Current MCC This feature is ideal in situations where the user wishes to temporarily reduce the chargers AC power consumption for example when limited AC source power is available To activate the MCC menu press the rotary controller knob 3 once which will show the following screen H Oc 12 60 a ATi Moas Charge Current 3 Wee 45 Al Now it s possible to turn the rotary controller knob 3 clockwise or counter clockwise to adjust to the preferred charge current level The charge current level is represented as percentage of maximum rated charge current and in actual Amps between brackets The minimum MCC level is 10 When the desired MCC level is selected press the rotary controller knob 3 once to jump back to the normal operating display mode The MCC level will be stored in internal memory and remains the setpoint until it is changed again using the MCC menu In the top right area of the display you can see a small battery icon which represents the charging state of the battery This state is directly linked to the charge status bar o

Download Pdf Manuals

image

Related Search

Related Contents

User Manual  Philips BDP7700 User Guide Manual  Téléviseur LED    USER MANUAL CommRadio CR-1a Communications Receiver  LBG PROTOCOLS - Clean Your Lymph System, Light Beam Generator  Toque Blanche GAS BOILING PANS  (PDFファイルが開きます)新モデル発表会 2011春  Delta RP1001 Installation Guide  Samsung MR89 دليل المستخدم  