1. 1 USB communication with TR 71U 72U 73U data loggers cannot be carried out using WindowsNT4 0 Weight Attached Sensors About 62g Including one AA battery TR 3100 x 1 TR 3100 x 1 Temp Humidity Sensor Temp Humidity Sensor AA alkaline Battery LR6 x 1 User s Manual Warranty x 1 USB Cable x 1 US 15C length 1 5m Software Set x 1 User s Manual Warranty x 1 TR 0106 x 2 TEP Resin coated sensors Accessories Included in package There are two types of temperature sensor for TR 71U depending on measurement range 2 Battery life depends upon the measuring environment recording interval and quality of the battery being used System Setup AA Alkaline battery LR6 x 1 Software T amp D Recorder for Windows Data Logger System T amp D Recorder for Windows ZO S Standard Temperature Sensors TR 0106 x 2 Insert Install Standard Humidity and Temperature Sensor TR 3100 4 USB Communication Cable Cc US 15C Text File Standard Humidity Connect Connect Printout and Temperature Sensor TR 3100 A Caution regarding safety To ensure safe operation carefully read instructions before using this unit TandD s TR 71U 72U 73U and TR 51S 52S have been tested for electro magnetic radiation and confirmed to comply with the requirement of RTCA DO 160E Section 21 Emission of Radio Frequency
2. TR 1106 D Stainless Protection Sensor Cable Length 2m Thermal Time Constant In the Air Approx 36 Sec In agitated water Approx 7 Sec r T TR 1 320 l 70 30 2000 mS L d of od Stainless Protection Sensor Cable Length 2m Thermal Time Constant In the Air Approx 12 Sec In agitated water Approx 2 Sec Materials Thermistor Stainless Pipe SUS316 Teflon Compaction Tube Teflon Resin FEP Shielded Possible Measurement Range 60 to 155 C Sensor Temperature Durability 70 to 180 C Water Resistant Ability Splash Resistant Measurement accuracy Average 0 5 C 40 to 80 C Average 1 0 C 60 to 40 80 to 100 C Average 2 0 C 100 to 155 C TR 71U 72U 73U TR 01 06 15 600 TPE resin shielded sensor i Cable Length 0 6m Thermal Time Constant In the Air Approx 75 Sec 5 5 TR 0306 Stainless Protection Sensor Thermal Time Constant In agitated water Approx 18 Sec 1s water resistant T R 0 5 0 6 7 293 600 Stainless Protection Sensor SE SIAN NS Cable Length 0 6m Thermal Time Constant In agitated water Approx 20 Sec is water resistant Possible Measurement Range 40 to 110 C Sensor Temperature Durability 50 to 115 C Measurement Accuracy Average 0 3 C 20 to 80 C Average 0 5 C 40 to 20 80 to 110 C ery Cable Length 0 6m E Only stainless section Only stainl
3. 15 20 30 Seconds Printing Selected Range or File for Entire Period 1 2 5 10 15 20 30 60 Minutes Total of 15 choices Graphs Tables Recording Capacity 8 000 Readings x 2 Channels 8 000 Readings x 3 Channels Compatible OS Microsoft Windows 2000 XP Vista English Recording Method Endless Loop Method Overwrite from the oldest data when recording capacity is full Microsoft Windows 98 Me English One Time Method Stop recording when recording capacity is full Microsoft Windows NT 4 0 English 1 LCD Display Measurements Ch1 only Ch2 only alternating display Measurements Ch1 only Ch2 only Ch3 only alternating display PC CPU IBM Compatible with higher than Pentium 90MHz Recording Status Battery Life Warning Recording Status Battery Life Warning USB Port 1 0 1 1 Amount of Recorded Data Unit of Measurement Amount of Recorded Data Unit of Measurement Memory More than 16MB Power AA alkaline battery LR6 Hard Disk More than 4 MB of free space Data will need more space Battery Life About 1 year 2 About 10 month 2 Monitor VGA 640 x 480 more than 256 colors Data Back up Activated when battery power is low or when switch is off About 1 year Interface USB Communication Time USB Communication Cable option RS 232C When downloading 1 unit of full data about 8 seconds USB Communication Cable When downloading 1 unit of full data about 12 seconds Dimensions H55mm x W78mm x D18mm
4. 1100hPa Temp Humidity Graph Temperature Humidity and Barometric Pressure Graphs for each Channel External Sensor 40 to 110 C 0 to 50 C 10 to 95 RH 0 to 50 C 10 to 95 RH Graph Display Zoom in out and scroll with mouse or keyboard Optional Sensor 60 to 155 C 1 40 to 110 C 40 to 110 C Change Channel Colors Turn ON and OFF Channel Display Measurement Accuracy Average 0 3 C 20 to 80 C 5 RH Average 0 3 C 5 RH 1 5hPa Data Display Channel Name Recording Interval Number of Readings Standard Sensor Average 0 5 C 40 to 20 80 to 110 C At 25 C 50 RH 20 to 80 C Average 0 5 C At 25 C 50 RH Highest Lowest and Average Readings Unit of Measurement AB Cursor Dates Times and Data Readings 40 to 20 Calculated Difference between Cursor A and B 80 to 110 C Number of Channels 8 Channel Simultaneous Display and Processing Measurement Resolution 0 1 C 1 RH 0 1 C 1 RH 0 1hPa Possible to process mixed data from TR 71U TR 72U and TR 73Uunits up to 4units Sensor Materials Thermistor Macromolecular Thermistor Macromolecular Macromolecular Others Data List Display Calculation Range Settings Data Maintenance Humidity Sensor Humidity Sensor Humidity Sensor Edit Recording Conditions Delete Data by Channel Barometric Pressure Re order Data by Channel Sensor File Output T amp D Common Data File Text File CSV etc Recording Interval 1 2 5 10
5. Energy RTCA DO 160E Section 21 RTCA stands for Radio Technical Commission for Aeronautics a not for profit corporation formed to advance the art and science of aviation and aviation electronic systems for the benefit of the public helps to develop standards to assure the safety and reliability of all airborne equipment http www rtca org The DO 160E published by RTCA is widely used as a standard for environmental qualification testing to show compliance with appropriate airworthiness requirements Section 21 of DO 160E concerns the Emission of Radio Frequency Energy The tests in this section are performed to determine that the device does not emit radio frequency interference in excess of the specified limits Every carry on electronic device must comply with radio frequency emission and susceptibility guidelines outlined in Section 21 of the RTCA DO 160E document whether it flies in the passenger cabin or cargo hold The DO 160E is recognized by the International Organization for Standardization ISO as a de facto for international standard ISO 7137 Web Site Colors in the photos in this catalog may be different from real product colors The specification and designs of the products in this catalog are true as of April 2009 Specifications are subject to change without notice Microsoft Windows and Excel are registered trademarks of Microsoft Corporation USA and other countries Compan
6. save to files and or print it out Moreover it is possible to connect more than one unit at the same time Wide Temperature Measuring Range 60 C to 155 C The external sensor that comes with the TR 71U can measure and record from 40 C to 110 C while optional sensors can give you a range of 60 C to 155 C There is an array of optional external sensors to meet your every need Humidity Measurement Range 10 to 95 RH The two channel external sensor that comes with the TR 72U can measure and record temperature from 0 to 50 C and humidity from 10 to 95 RH One Year Continual Use on One Battery Using our specially designed low energy consumption circuit this unit can run on one AA Alkaline battery for up to one year of continued use No need to worry about where you place it as the battery will allow you to measure and record over long periods of time no matter if the unit is in transit or in a distant place Note Battery life will depend on the recording environment recording interval communication frequency and ambient temperature The above battery life test was carried out using a brand new battery and in no way do we guarantee a battery s life Large Data Capacity 8 000 Readings x 2 Channels TR 73U 8 000 x 3 Channels Each channel can record up to 8 000 readings giving you about one year of continuous recording at a recording interval of 60 minutes Reliable Backup Function means No Data Loss We have eliminated t
7. Thermo Recorder TR 71U TR 72U TR 73U Temperature Humidity Barometric Pressure Data Logger with USB Connection d W R FOR Measuringiana Recoraing Temperature Hur a ana FeTessure y rA a N a Our compact lightweight TR 71U 72U 73U units allow you to effortlessly measure and record temperature in a range of 60 to 155 C humidity from 10 to 95 and pressure from 750 to 1100 hPa That data can then be transferred via high speed USB cable to your computer whereby our exclusive software empowers you to create colorful graphs and tables for saving or printing f Easy to Use Software makes Graph and Table Creation a Snap Thermo Recorder Data Logger USB Connection TR 71U 72U 73U Easy USB Connection Multiple Units OK Real time Monitoring and Graph Display Adjustment Function Enabled Software 1 Year Operation with only 1 AA Battery Measure and Record p Wiis oF TR 73U TR 72U f aa a ae 2 or more Measurement and Recording Channels in Each Unit TR 71U has two temperature channels and TR 72U has one temperature and one humidity channel TR 73U has a total of three channels one temperature one humidity and one barometric pressure channel The data recorded into the TR 71U TR 72U units can then be downloaded quickly via USB cable to your computer whereby with our exclusive software you can easily process the data into graphs tables
8. bly affordable Pressure Measurement Range 750 to 1100hPa The internal sensor that comes with the TR 73U can measure and record air pressure from 750 to 1100hPa Data Collector TR 57U Easy Data Collection Easy Graph Display Communication Method Via Communication cable for TR 71U 72U Communication Cable TR 6C10 Ray View Recorded Data on TR 57U LCD Graph Display Graph Display logger can be easily displayed in graph Temperature Humidity Voltage Data that has been collected from the form which enables you to view the data onsite It is easy to change of the date format and temperature unit C F settings mA 03 17 708 16 50 uo 16M ce 25 5 Standard Software T amp D Recorder for Windows Easy to use Windows compatible software allows you to control all aspects of set up for any TR 71U TR 72U TR 73U TR 57U unit as well as to print and to create text files tables and colorful graphs from the recorded data Up to 8 Channels of Data can be Processed at One Time By simply downloading the data from the main unit a colorful graph representing that data will be automatically created Up to 8 channels 4 units of data can be represented in one graph ar iia a ALA Creating Text Files You can create Text Files CSV format etc to allow you the option of processing and managing your data using Excel Lotus or any other popular spreadsheet software Opti
9. ess section TR 0206 M _ Q EE Stainless Protection Sensor Cable Length 0 6m Thermal Time Constant In the Air Approx 75 Sec TR 0406 3 op Ca a aM 5 6 d Only stainless section is water resistant Stainless Protection Sensor Cable Length 0 6m Thermal Time Constant In agitated water Approx 20 Sec T R 0 7 0 6 14 56 600 Stainless Protection Sensor j T T Cable Length 0 6m SSSA Thermal Time Constant In agitated water Approx 18 Sec Only stainless section is water resistant Materials Thermistor TPE resin shielded sensor TPE resin shielded wire M3Screw Hole Compaction Tube Stainless Pipe SUS304 Stainless Pipe SUS316 unit mm lM Product Specifications Unit Measurement Channel TR 71U 2 Channels TR 72U 2 Channels TR 73U 3 Channels li Software Specifications Software T amp D Recorder for Windows Compatible Devices TR 71U TR 72U TR 73U TR 57U Select from Temperature and Humidity Temperature Humidity Communication Recording Start Programmed Start Immediate Start Recording Stop Chl internal Ch 2 external Barometric Pressure Functions Main Unit Settings Recording Interval Recording Method Upper and Lower Limits Measurement Item Temperature Temperature Humidity Temperature Humidity Barometric Pressure Downloading of Recorded Data Internal Sensor 10 to 60 C 10 to 60 C 10 to 60 C 750 to
10. he worry of losing data due to power loss or the switch being accidentally turned off When Battery Power becomes Low When battery power becomes low a battery life warning will appear on the unit s display indicating that the battery should be changed If within a short time the battery is changed measurement and recording will not be interrupted and there will be no data loss If the battery is not changed the unit will automatically go into SLEEP mode whereby measurement and recording will stop but due to our BACK UP FUNCTION data will not be lost and will remain saved for up to one year REC DATA ENDLESS Ce CA DATA ENDLESS D ty Battery Life 2 f f C Warning Indicator iG LJ pe When the Switch is turned OFF If while recording the power switch is accidentally turned OFF data will not be lost but will be saved for up to one year from the time it was switched OFF Note Even if the unit is in sleep mode it needs battery power Hence a total loss of battery power or removal of the battery will result in the loss of data Ready to Use All in One Package Everything you need to get started main unit sensor battery software communication cable and user s manual is included in this All in One Package All you need to do is supply the computer Connect Download and Analyze j Display is a composite Easy to Read Multi Functional Display The easy to read LCD displays present temperature recording c
11. ondition battery life warning and unit of measurement TR 71U 72U ay ea TA ce saa Giles 7 pas NL a E an La ws Co By o1 2L ene TR 73U 2 DATA END ESS f REC pA_A_A_F_F COM K C a Ga Gan Gy rf Lal L Dals 9 Ce pa The channel number of the measurement being displayed will appear The recording condition will appear ON Recording in progress BLINKING Waiting for programmed start 3 After every 2000 readings the scale will be marked from left to right 4 This will appear when data is being sent or received ONETIME When the number of recorded readings reaches 8000 FULL will appear in the unit s LCD display and recording will automatically stop ENDLESS When the number of recorded readings reaches 8000 the oldest data reading will be overwritten and recording will continue When the battery power becomes low this will appear in the LCD display If the battery power becomes even lower SLP will appear and normal operations will stop If the 4 signal appears please change the battery as soon as possible The unit of measurement C F hPa for the display will appear Current measurements or operational messages such as FULL or SLP will appear Accurate Compact Lightweight and Affordable Our exclusive design and technology has allowed us to create a highly accurate yet compact and lightweight unit 55x78x18mm 62g that is unbelieva
12. ons Adjustment Function By setting adjustment values beforehand you can record and display the post adjusted measurement values You can choose from two adjustment methods l point and 2 point Adjustment will be carried out using an adjustment equation of Y aX b where X is the pre adjusted measurement value and Y is the post adjusted value Current Readings Monitoring Display With our exclusive software you cannot only monitor the current measurements at a set interval but can view those measurements in a continually changing graph You can simultaneously display the current measurements and corresponding graphs for the number of units you have connected Graph Table Printing Function You can print out in color or monochrome the graphs just as they appear on your screen You can also print out in table form all of the data in order of date and time TR 71U 72U 73U TR 72U 73U TR 1C30 m De E ae Note Only one cable per sensor Cannot be used with D Temperature Humidity sensor TR 3110 or TR 3100 Sensor Extension Cable Cable Length 3m TR 5C10 0 EEE Note Only one cable per sensor Cannot be used with b Temperature Humidity sensor TR 3100 75 TR 07K2 rr Wall Attachment u Included Wall Mount Screws x 2 Double Sided Adhesive a Tape x 1 Sensor Extension Cable Cable Length 1m D D Material ABS Resin TR 71U 72U Materials Vinyl Chlo
13. ride Coated Wire Materials Vinyl Chloride Coated Wire TR 3110 om Humidity and Temperature Sensor Cable Length 1m TR 3100 Humidity and Temperature Sensor Materials Temperature Humidity Sensor Polypropylene resin Vinyl Chloride Coated Wire unit mm Humidity Measurement Range 10 to 95 RH Temperature Measurement Range 0 to 50 C Sensor Durability Range 10 to 55 C Humidity Measurement Accuracy 5 RH at 25 C and 50 RH Service Life 1 year under normal conditions Operational Conditions No Dew Condensation or Water Leakage No contact with organic solvents solutions or gasses emitted from spoiled food TR 07C Serial Communication Cable Cable Length 1m Note For communication with computer 1000 i TR 6C10 n_a eee Serial Communication Cable Cable Length lm Note For communication with RTR 57U and TR 57U 1000 PT Ah Ts Optional Sensors unit mm TR 57U Data collector AAA Alkaline Note Cannot be used with TR 73U Batteries LR03 x 2 a e A Ke moe USB Cable US 15C x 1 a ie RS 232C Communication Cable TR 07C x 1 Software CD ROM and Manual x 1 TR 71U Teflon Shielded Sensor Cable Length 0 6m Thermal Time Constant In the Air Approx 15 Sec In agitated water Approx 2 Sec TR 1 220 185 30 2000
14. y names and product names are trademarks or registered trademarks of each company Teflon is a registered trademark of the Dupont Corporation and of the Mitsui Dupont Fluro chemical Corporations Lotus is a registered trademark of the Lotus Development Corporation Pentium is a registered trademark of the Intel America Corporation re nee ne TASHIKA BOER SHOKAI K K 1 12 Kaiyo cho Ashiya shi Hyogo 659 0035 JAPAN Tel 81 797 23 9035 Fax 81 797 23 2105 e mail sales tashika co jp URL www tashika co jp Product information and FAQ http www tashika co jp E Distributor 2009 04 16304370106F