Home
PW250LC and RCA4plus - Fujitsu manual server
Contents
1. Figure 7 Connecting the RCA to PRIMEPOWER 450 U41618 J Z916 1 76 25 Remote Communication Adapter LAN Console Connecting to the PRIMEPOWER 100N Serial Ports A B Z oog TIT III IE ASSSSS8S27 CONTRA EES mo Li Eoee 635555 eea ane mn nd a vas gi wu 2e mi Serial A Use of serial port A 0 en U I Ad RCA4 i La LV Serial A B Use of serial port B U U Ss I my Adapter Ex 9pole 0 25pole O SerialB SerialA ri SerialA 0 Jo L Amm RCA4 Figure 8 Connecting to the PRIMEPOWER 100N 26 U41618 J Z916 1 76 LAN Console Remote Communication Adapter 5 2 2 Cable types The RCA4plus comes with a power cable 1 8m with an earth contact type plug and an RCA4plus console port cable The following serial cables are required for connecting the RCA4plus to the console port of the PRIMEPOWER or RM server and must be ordered separately Name Length Order Part No Power cable with rubber 1 1m D RB258 C110 connector for rack installation Power cable with rubber 2 5m D KB258 C250 connector for rack installation Port cable for PRIMEPOWER
2. The following command can be used to close an open or hanging connection like this directly via the administration access in the RCA4plus in the case of console connections set up via the RCA4plus Syntax port lt Port logout Port Port number of RCA lt TCP Port number gt 3000 for telnet and rtty connections or lt TCP Port number gt 3100 for ssh connections i e from 1 8 with RCA4plus The TCP port number referred to above is taken from the entry under TCP PORT from the output of the command showlancon n lt ConsoleName gt ConsoleName is the symbolic system name of the target system which the console connection is to be set up An error message is output if there is no connection for the specified port number Once the opened or hanging connection has been reset on the relevant port it can be re opened Caution Please note that also an active connection is aborted or reset For information on hanging connections in relation to an RCA4 or RCA please refer to the predecessor manual see the appendix Related publications 68 U41618 J Z916 1 76 LAN Console Error situations 5 8 4 2 No output in console window If output is still not possible in the console window of a connected system despite the connection being set up successfully this blockade can be lifted if appropriate from the LAN Console by entering the following command echo 021 c gt lt device gt device is derived fro
3. Width 222 3 mm Height 44 5 mm Depth 203 2 mm Weight 1 kg Table 8 Dimensions and weights 28 U41618 J Z916 1 76 LAN Console Remote Communication Adapter 5 2 3 4 Standards Product safety IEC60950 1 EN60950 1 ANSI UL 60950 1 CSA C22 2 No 60950 1 CAN CSA Electromagnetic EN 55022 class A compatibility EN 55024 EN 61000 3 3 FCC part 15 class A Table 9 Standards 5 2 3 5 Conformity tests Europe CE EU Directive 89 336 EEC EMC 73 23 EEC product safety Table 10 Conformity tests 5 2 3 6 Approvals Global IEC CB Scheme Table 11 Approvals 5 2 4 Switching on the RCA4plus gt The RCA4plus is switched on by connecting it to the power outlet QQ AA AM QQQOOQ 2 2 ONUNE LNK TRAFFIC 100MBps COMPUTERS RCA4plus SIEMENS u Figure 9 Front view of RCA4plus U41618 J Z916 1 76 29 Remote Communication Adapter LAN Console Init Restart INIT interrupts operation of the RCA and causes the RCA to restart VVith the use of INIT the RCA is reset to the default values set at the factory If you vvant to delete the current configuration press INIT for about 7 seconds The ONLINE LED first flashes slowly then more quickly to acknowledge the deletion If you also want to delete the IP address press INIT for a further 5 seconds To acknowledge the deletion ONLINE flashes even more quickly Thus the state of deliv
4. 116 U41618 J Z916 1 76 Related publications Related publications The manuals are available as online manuals see http manuals fujitsu siemens com or in printed form which must be paid and ordered separately at http FSC manualshop com 1 LAN Konsole und System Management Konsole Installieren Konfigurieren und Bedienen System Administrator s Guide Target group System administrators Content This manual describes the setting up and cabling of the LAN Console RCA4 and RM or PRIMEPOWER systems It describes the installation ofthe LAN Console software the configuration ofthe LAN Console and RCA4 the operation and diagnostic options U41584 J Z916 1 76 2 LAN Console Installation Configuration and Operation System Administrator s Guide Target group System administrators Content This manual describes the setting up and cabling of the LAN Console RCA3 and RM and PRIMEPOWER MR systems It describes the instal lation ofthe LAN Console software the configuration ofthe LAN Console and RCA3 the operation and diagnostic options U41224 J Z916 1 76 3 Reliant UNIX 5 45 Reliant UNIX Installation Installation Guide Target group System administrators Content The manual describes the re installation and updating of Reliant UNIX as well as initial installation of it when there is a new system disk U41618 J Z916 1 76 117 Related publications 4 5 6 7 Reliant UNIX 5 45
5. 5 7 4 RCA system information Information on the RCA4plus system settings can be found via the adminis tration access under the user name Admin in addition to RCA access the section RCA commands describes the main commands For system information on the RCA4 please refer to the LAN Console and System Management Console manual and for the RCA3 see the LAN Console manual in Related publications U41618 J Z916 1 76 65 Error situations LAN Console The configuration and functionality of the XSCF is described in the XSCF documentation see Related publications on page 117 An administration access towards the XSCF can be created as described in Commands on page 41 5 8 Error situations 5 8 1 No response from the RCA If the RCA4plus still cannot be accessed after booting either with ping or via the administration access the network parameters IP address MAC address must be checked The network parameters can be corrected using the Solaris system commands dhtadm and pntadm see the man pages It is also possible to delete the entire bootp configuration for the RCA4plus see page 57 and then create it again see Addressing the RCA in the network on page 48 If you cannot access the XSCF within the LAN please consult the XSCF documentation see Related publications on page 117 Among other things the reset of the console connection to the serial port is here described if the configura
6. Covers the access rights PALL USER SMON PCON BREAK E ADMIN APPLIANC Covers the access rights PALL USER SCON SMON PCON BREAK U41618 J Z916 1 76 93 RCA commands LAN Console 5 9 2 6 Serial Connections Connect The Connect command establishes a console connection from the RCA serial console port to a target system attached to another port on that RCA If the specified port is already in use you can take over the console connection in accordance with the SHARE Mode Server Share command set To use this command you must have previously issued a Server CLI Connect command to activate the connection option Access rights Port specific or ADMIN APPLIANCEADMIN Syntax CONNECT L lt RCA PortNumber gt Parameter RCA PortNumber Port numbers 1 8 The port required can be selected from the display of the available ports without specifying the port number Disconnect The Disconnect command terminates a console connection that was previously initiated with a Connect command This command can only be issued from the command interface of the RCA input Ctrl and Access rights Port specific or ADMIN APPLIANCEADMIN Syntax DISCONNECT 94 U41618 J Z916 1 76 6 Teleservice The LAN Console PW250LC is the central point of Teleservice access to the networking PRIMEPOWER and RM servers that can be reached from the PW250LC Teleservice gives you
7. screen page in the RCA setup routine see manual LAN Console U41224 J Z916 1 76 Existing configuration entries can be checked removed and changed in the way described in the section Configuring the LAN Console on page 41 54 U41618 J Z916 1 76 LAN Console Configuration 5 4 3 5 Connecting further RCAs to the LAN Console Another RCA4plus is configured in basically the same way as described for an initial configuration in the section Initial configuration of the LAN Console and RCA on page 40 First configuration entries should be created for the existing LAN Console using the new RCA as described under mklancon Create LAN Console configuration entries on page 43 The RCA is configured in keeping with the section Configuring the RCA on page 48 Finally the RCA has to be activated and configured as described under Addressing the RCA in the network on page 48 and RCA access on page 50 Another XSCF is connected by creating configuration entries for the XSCF on the LAN Console The configuration steps for the XSCF itself that enable the access to PRIMEPOWER 250 450 systems via XSCF have to be done according to XSCF documentation see Related publications on page 117 5 4 3 6 Connecting another LAN Console to the RCA To configure another LAN Console connected to an existing RCA all configu ration entries for the existing LAN Console must also be created on the additional LAN Conso
8. 76 U41618 J Z916 1 76 LAN Console RCA commands Resume You can use this command to exit the RCA command interface CLI and return to the console window of the existing connection Access rights None Syntax RESUME U41618 J Z916 1 76 77 RCA commands LAN Console 5 9 2 3 Server commands Server CLI commands These commands refer to the CLI access At least one of the possible param eters must be specified Access rights SCON or APPLIANCEADMIN Syntax SERVER CLI LTYPE lt type gt LCHAR lt character gt LCONNECT ON OFF EHISTORY HOLDJAUTO CLEARJ KEEP LTIMEOUT lt timeout gt Parameter type Terminal type to be used on CLI port The entire name of the type must be specified abbreviations are not permitted Valid types are ASCII VT100 VT220 and OFF Default ASCII character The CLI access character when pressed simultaneously with the Ctrl key during a running console connection will suspend the session and place you in the command level of the RCA CLI ASCII character in the range A to _ underscore Default d Connect ON OFF Enables or disables the ability to use the Connect command from the serial console port When enabled the console port user may use the Connect command to establish a console connection via one of the remaining ports of the RCA When disabled you cannot issue the Connect command from the serial CLI port Default ON 78 U41618 J Z916
9. 2163305364 Nodel INTEGRATED SunOS 5 8 Generic 108528 01 2163410482 Node2 INTEGRATED SunOS 5 8 Generic 108528 01 2163409787 Node3 INTEGRATED SunOS 5 6 Generic_105181 23 2163409835 5 Define the Teleservice machine for the entire cluster with the command event adm X lt SystemName PRIMESTATION gt t TELEX C telx U41618 J Z916 1 76 109 TeleCall Teleservice Adding a new machine This step must also be executed when adding a new machine to an existing cluster This completes generation of the TeleCall cluster You can initiate a test call on the machines to the Teleservice Center in Paderborn or Munich with the LOGPATH reactions calltelex M This is a test call please cancel command in order to perform a function test 110 U41618 J Z916 1 76 Glossary bootp Protocol that is used for booting a system remotely cluster A group of systems nodes interacting tightly as a system to provide fast uninterruptible computer services Console The operating controls of a computer or a data processing system that give the user direct access to a system DNS Domain Name Service MAC Media Access Control Hardware address for accessing a device Mirroring Modern hard disks are highly reliable but even so a variety of methods is used to ensure the survival of your vitally important data even if a disk failure does happen One of the simplest methods is
10. Authorized to set up console connections Two classes have been predefined in the RCA4plus to facilitate assignment of these rights APPLIANCEADMIN Covers the rights PALL USER SCON SMON PCON and BREAK ADMIN Covers the rights PALL USER SMON PCON and BREAK All the possible user specific settings with fewer access rights than APPLI ANCEADMIN and ADMIN can be included in a further class user This results in the following hierarchy with regard to access rights APPLIANCEADMIN gt ADMIN gt user The necessary access rights are also specified in the RCA commands described below U41618 J Z916 1 76 71 RCA commands LAN Console If the identity check for accessing the RCA has been disabled see the Server Security command user independent console connections can be set up via the RCA4plus With such console connections access is only possible to the associated port including the authorization to send a BREAK signal 5 9 2 List of commands il Commands and keywords are not case sensitive This appendix only lists the most important commands and options for RCA users Other commands and more detailed descriptions can be found in the help texts for the RCA 5 9 2 1 Help command The Help command outputs information on all RCA commands Access rights None Syntax HELP lt command_name gt Parameter command_name Command name Default Displays all available commands 5 9 2 2 Port
11. Solaris PRIMEPOWER ServerView Suite 2 2 System Administration within a Domain Target group System administrators Service technicians Content Bundling and administration of several computer nodes using Server View Suite and Domain Admin 122 U41618 J Z916 1 76 Related publications PRIMEPOWER publications 23 GP 7000F PRIMEPOWER Systems Safety Instructions Target group System administrators technicians Content Safety brochure in 25 languages for the GP 7000F PRIMEPOWER systems 24 PRIMEPOWER Solaris System Console Software SCS User s Guide PRIMEPOWER 2500 2000 1500 1000 800 900 Target group System administrators Content Description of the software used on the System Management Console Both the PRIMEPOWER200 and the PRIMESTATION as SMC are taken into account The manual is available on CD and is included in the scope of delivery of the SCS 25 PRIMEPOWER Solaris User s Guide PRIMEPOWER 100N 200 400 600 250 450 650 850 Target group System administrators Content User Guide for the PRIMEPOWER Midrange Systems 100N M200 M400 M600 M250 M450 M650 M850 U41618 J Z916 1 76 123 Related publications 26 27 28 29 30 PRIMEPOWER Solaris User s Guide PRIMEPOWER 2500 2000 1500 1000 800 900 Target group System administrators technicians Content User s guide for PRIMEPOWER Enterprise Systems 2500 2000 1500 1000 800 900 also contains the administrat
12. 1 76 LAN Console RCA commands History HOLD AUTO CLEAR KEEP Specifies the kind of output of data from the Port History Puffer when a console connection is set up HOLD AUTO or cleared down CLEAR KEEP HOLD Upon connection setup only the number of characters in the History Buffer of the associated port is displayed AUTO Upon connection setup both the number of characters in the History Buffer of the associated port and the characters themselves are displayed CLEAR Upon connection setup the history buffer of the associated port is cleared KEEP Upon connection setup the history buffer of the associated port is retained Default HOLD CLEAR tim out Number of timeout minutes in the range 0 90 If no data is received or transmitted for the specified time during an active console connection the session will time out A zero value indicates that no timeout check takes place This value is used for any RCA port for which no timeout value was set with the Port Set command Furthermore this value is valid for administration access to the RCA Default 15 minutes Server Flash The Server Flash command updates the RCA firmware This command is needed in order to make new developments available or to install a higher release version The RCA firmware comprises two components that can be updated 1 The boot image with the RCA start and self test routines and 2 The application image that provides the actual RCA functionali
13. 11 Install and detach mirroring Preinstallation and Installation state data base mddb01 c 2 dev dsk c0t0d0s7 dev dsk c0t2d0s7 root mirror di m d10 d10 1 1 dev dsk cOt0d0s0 d11 1 1 dev dsk cOt2d0s0 swap mirror d2 m d20 d20 1 1 dev dsk cOt0d0s1 d21 1 1 dev dsk cOt2d0s1 il Further information on the commands can be found in the man pages man command name 12 U41618 J Z916 1 76 Preinstallation and Installation Install and detach mirroring 4 4 1 Mirroring the root and swap file systems The configuration above is defined by the following commands Order and syntax options have strictly to be observed netadb a f mddbOl netainit f d10 netainit dll netainit dl netaroot dl netainit f d20 netainit d2l netainit d2 Change the entry for the swap file system in the file etc vfstab to the meta device dev md dsk a2 dev dsk cOt0d0s1 svap no change to dev md dsk d2 swap no lockfs fa At that time the system has to be rebooted reboot metattach dl dll metattach d2 d21 dumpadm d dev md dsk d2 U41618 J Z916 1 76 13 Install and detach mirroring Preinstallation and Installation 4 4 2 Detach mirroring of the root and swap file systems metadetach dl dll metaroot dev dsk c0t0d0sO metadetach d2 d21 Change the entry for the swap file system in the file etc vfstab to the device dev dsk c0t0d0s 1 dev md
14. 2m D GPRAC KB04PE16 MR 25 pin DSUB female 10m D GPRAC KB04WE16 Port cable for PRIMEPOWER 3m D GP70P KA02 250 450 10m D GP70P KA03 Port cable for RM 5m D GPRAC KBO4RE16 RJ45 to 9 pin DSUB female 15m D GPRAC RBO4ME 16 Network cable LAN for 2m 100m D GP7KB 13xx connecting to HUB or Switch xx 02 05 10 15 30 50 xx A0 for100m Network cable LAN for direct D GP7KB 14xx connection system console to Category5 UTP cable xx RCA CCU cross over cable meters xx 05 10 20 50 xx A0 for 100m Table 4 RCA cabling the port cable may also be used with PRIMEPOWER systems using the DSub adapter 9pole to 25pole that is delivered with the system Thus the cables with a length of 5m and 15m are also available for PRIMEPOWER systems U41618 J Z916 1 76 27 Remote Communication Adapter LAN Console 5 2 3 Technical specifications of the RC A4plus 5 2 3 1 Power ratings Mains voltage range 100V 250V autorange Nominal frequency 50 60 Hz Power consumption approx 22 W Rated current 0 5A Table 5 Power ratings 5 2 3 2 Environmental conditions Temperature 0 to 40 C Relative humidity 10 to 90 non condensing Table 6 Temperature Requisite intake and exhaust air clearance for ensuring sufficient ventilation Front min 100 mm Rear min 100 mm Table 7 Intake and exhaust air clearance 5 2 3 3 Dimensions and weights
15. 4 2 Generating the Telecall cluster 107 GIOSSAIy iii dE de SE DL A to d e EE ES Es a 111 Abbreviations 2 DR wR P ae dE a 113 Related publications aa 117 Index ht ms A LE LE en ES EE ea 129 U41618 J Z916 1 76 1 Preface For system administration and monitoring of the Midrange and Entry level Servers of Fujitsu Siemens Computers a LAN Console is required This task can be performed by a PRIMEPOWER based LAN Console PW250LC The server systems are connected to the PW250LC via V 24 Ethernet converters RCA4plus located close to the system max 15m away or in the system cabinets The LAN Console is placed at any suitable position in the LAN The PW250LC is based on a high performance SPARC processor Pedestal or 19 inch rack models are available The PW250LC is released for the following products PRIMEPOWER 100N 200 400 600 250 450 650 850 with Solaris RM300 400 600 with Reliant UNIX The PW250LC is supplied optionally with the operating system Solaris 8 9 or 10 The Teleservice port for all networking PRIMEPOWER or RM servers can also be managed via the PW250LC teleservice gateway which means that only one line to the Service organization is required for all networking PRIME POVVER RM servers Use of the System Management Console SMC is mandatory for system administration and monitoring of the Enterprise Servers models 900 1500 2500 800 10
16. J Z916 1 76 45 Configuration LAN Console rmlancon Remove LAN Console configuration entries Syntax rmlancon lt RCA SystemName gt t lt RCA Type gt lt RCA SystemName gt lt RCA PortNumber gt n lt ConsoleName gt a t lt RCA Type t lt RCA Type gt c lt Kind of connection gt L lt RCA SystemName gt RCA SystemName All configuration entries belonging to the specified RCA are displayed and can be removed with y RCA PortNumber If a configuration entry is found for the specified TCP IP port number on the RCA4 plus or the XSCF admin or admssh is also possible which is served by the RCA it is displayed and can be removed with y n ConsoleName The configuration entry belonging to the specified symbolic system name is output and can be removed with y All configuration entries on the LAN Console for all RCA types are displayed and can be removed with y t RCA Type The permitted entries are 3 for the RCA3 4 for the RCA4 plus and 5 for the XSCF All of the configuration entries on the LAN Console of the specified RCA type which may fulfill the further conditions are displayed and removed with y c Kind of connection The permitted entries are t for telnet and s for ssh exclusively for the RCA4 plus and the XSCF Only configuration entries of the indicated kind of connection are displayed and removed If the last configurat
17. RCA administration port for telnet 50 U41618 J Z916 1 76 LAN Console Configuration admssh RCA administration port for ssh These configuration entries are referred to as administration accesses to the RCA4plus in the follovving The configuration entry lt RCA SystemNames ssh need be created only if the RCA is also to be used in ssh mode An ssh connection to the RCA is not possible in the context of initial configuration Configuring the RCA The RCA is configured from the LAN Console using the administration access mentioned above and the xscon component described in the section Operating the LAN Console on page 58 In particular the administrator password must be assigned and the port parameters must be set for this configuration When it is delivered or after a potential initialization compare Init on i page 30 the RCA is in the te net mode In this mode the RCA4plus can only be accessed over the network via telnet or rtty connections This applies to the administration access as well as to all console connections via the individual RCA ports The conversion of the RCA to ssh mode is described in section Activate ssh mode on page 53 il The RCA4plus can be administered at any time via the additional console port using a serial connection section Connections on the rear ofthe RCA4plus on page 21 Syntax xscon lt RCA AdministrationAccess gt RCA AdministrationAccess The administ
18. Reliant UNIX Operation System Administrator s Guide Target group System administrators Content Description of the administration of Reliant UNIX Reliant UNIX 5 45 Commands Target group Shell users Content This document describes the Reliant UNIX commands in alphabetic order Reliant UNIX 5 45 User s Guide Target group Users Content Overview of the Reliant UNIX 5 45 operating system and an introduction into the general basics for users Reliant UNIX 5 45 System Administrator s Reference Manual Target group System administrators Content Commands and application programs for system maintenance file formats special files for system administration of the Reliant UNIX 5 45 operating system 118 U41618 J Z916 1 76 Related publications 8 Reliant UNIX 5 45 System Administrator s Guide User s Guide Target group System administrators Content This manual provides an introduction to UNIX system administration Among other things it describes the system administrator tools UNIX system configuration and support calculation of system usage as well as aspects of system security The manual applies both for MIPS based UNIX and for Intel based UNIX 9 Reliant UNIX 5 45 Error Diagnostics and Troubleshooting User s Guide Target group System administrators Content This document provides information on event management in RM200 RM300 RM400 RM600xxx RM600E systems 10 Rel
19. Remote Communication Adapter Connecting to the PRIMEPOWER MR server Correspondingly the cables are connected to serial port A on the backplane of the PRIMEPOWER system cabinet PRIMEPOWER 650 850 SERIAL A ng jodgz SERIAL B ng jodgz J of Caf U BEN j Ne YF KB MOUSE ETHERNET Figure 4 Connecting the RCA to PRIMEPOWER rack models f necessary remove the inserted adapter before connecting the RCA U41618 J Z916 1 76 23 Remote Communication Adapter LAN Console 25pol Bu 25pol Bu LAN RCI SERIAL A SERIAL B PRIMEPOWER 200 400 600 SERIAL A B 25pol Bu 25pol Bu O RCI LAN Figure 5 Connecting the RCA to the PRIMEPOWER 200 400 600 vertically or horizontally 24 U41618 J Z916 1 76 LAN Console Remote Communication Adapter Connection to PRIMEPOWER 250 450 systems Serial port tty a for RCA XSCF LAN port Figure 6 Connecting the RCA to PRIMEPOWER 250 Serial port for RCA tty a OR de SOOOOOOSI OQ OO OO 0606 6066 0101616 OOOO HE 2 2 ET QQ ER ER OQQOQO OQQQQQOQQQQQ OQQQ Q Q OOQ OOOO OOQ 3 DOODO 04 e H XSCF LAN port
20. The port to which the user is connected if access to the CLI was requested from an active console connection baud_rate Line speed in baud 9600 19200 Default 9600 size Number of data bits per character 7 or 8 Default 8 parity Parity NONE none EVEN even ODD odd Default NONE stop_bits Number of stop bits per character 1 or 2 Default 1 flow_control Flow control U41618 J Z916 1 76 75 RCA commands LAN Console NONE No Flow Control XONXOF Software XON XOFF Flow Control RTSCTS Hardware RTS CTS Flow Control DTRDCD Hardware DTR DCD Flow Control Default NONE timeout_seconds Timeout specification in minutes from 0 to 90 If no data is sent or received during the specified time when a console connection is active the console connection is termi nated The value 0 means that no timeout check takes place Default The value for timeout set for the entire RCA applies Server CLI Timeout cli_char Character for CLI access to the RCA in the range A to _ under score or None The CLI access character when pressed simulta neously with the CTRL key during an active console connection will place you in CLI command mode If None is specified the value specified in the Char parameter of the Server CLI command will be used see Configuring the RCA on page 51 Default None Quit This command closes the active console connection Access rights None Syntax QUIT
21. an ssh or telnet connection although this was configured with mklancon l option the reason may be that the specified parameters RCA username and password are not appropriate for the settings in the RCA4plus If the password of the RCA4 changed this can be adapted on the LAN Console Syntax key_create p lanconsole3 s lt ConsoleName gt ConsoleName Symbolic system name of the target system for which the console connection was configured But if the specified RCA user is invalid in the RCA4plus you must reset the connection via rmlancon and mklancon and reconfigure the user in the RCA If a connection via the XSCF cannot be created automatically please at first check the XSCF configuration with the help of the XSCF documentation see appendix Related publications If a connection cannot be created because the password was changed this can be modified with the following command key_create p lanconsole4 s lt ConsoleName gt as with RCA4plus U41618 J Z916 1 76 67 Error situations LAN Console 5 84 Disrupted RCA LAN Console connection 5 8 4 1 LAN connection disrupted It can happen that the connection between the RCA and the LAN Console was not terminated properly This results in an open hanging connection on the RCA side The reason for this could be that the LAN connector on the LAN Console has been detached or that the connection from the RCA to the LAN has not been working for some time
22. dsk d2 swap no change to dev dsk cO0t0d0s1 swap no At that time the system has to be rebooted reboot dumpadm d dev dsk cOt0d0s1 metaclear r dl metaclear d11 metaclear r d2 metaclear d21 metadb f d cOtOd0s7 cOt2d0s7 14 U41618 J Z916 1 76 Preinstallation and Installation First booting 4 5 First booting Identification When the system boots for the first time parameters for identification like host name network time zone and root password are required Language setting When the Solaris operating system has booted and signed off amask appears prompting the user name The desired language can be chosen in the following menu Desktop Login gt Options gt Languages Once you have entered the password the CDE Common Desktop Environment is started All other parameters are set using the usual Solaris tools U41618 J Z916 1 76 15 5 LAN Console The LAN Console supports the installation configuration administration and diagnostic management of one or more connected PRIMEPOWER entry level or midrange or RM servers The serial port ttya is the default console access for all PRIMEPOWER and RM servers This access is preferable towards the graphical console mouse keyboard graphics for reasons of access security and availability in critical operation and error situations The concept of the LAN Console with one or more RCAs offers an optimal administration e
23. enabled and disabled for setting up console connections The Admin administrator is predefined in the RCA with all extensive rights comparable with the user root on Solaris systems In addition additional users can be created in the RCA with different rights see User commands on page 90 A maximum of 64 users can be administered in the RCA The user name and password must be specified when setting up a console connection where an access check is in operation in the RCA It is therefore recommended as described under Configuring the RCA on page 51 that you create a superuser for all configured console connections in the RCA This user should have exclusive rights to set up console connections for all RCA ports and be able to issue a BREAK to the target system via an open channel This user in particular cannot reconfigure the RCA and also cannot reboot the RCA because of restricted rights Administration of the RCA can be implemented both via telnet ssh access and using the components xscon see xscon call on page 58 If xscon is used the configuration entries must have been created beforehand using the mklancon script Configuration entry lt RCA SystemName gt _adm mklancon t 4 c t lt RCA SystemName gt admin lt RCA SystemName gt _adm Configuration entry lt RCA SystemName gt _ssh mklancon t 4 c s lt RCA SystemNames admssh lt RCA SystemName gt _ssh RCA SystemName System name of the RCA admin
24. must be accessible using network commands for example ping System name of the RCA The RCA system name may have to be made known to the DNS Domain Name Service The RCA must be located in the same LAN segment as the LAN Console to enable the initial configuration of the RCA e Information required about the LAN Netmask of the RCA If a gateway has been set up IP address of the gateway to the network of the RCA e Ascertain the Ethernet address MAC address of the RCA The MAC address is the hardware address that is used to access a device initially The Ethernet address MAC address is shown on a sticker attached to the RCA housing see chapter Connections on the rear of the RCA4plus on page 21 e Define the allocation of RCA ports With RCA4plus COM ports 1 8 are mapped to port numbers 3001 3016 for rtty and telnet connections and to port numbers 3101 3108 for ssh connections Allocate the RCA ports to PRIMEPOWER and RM servers Define a symbolic system name for each RCA port PRIMEPOWER and RM server allocation 40 U41618 J Z916 1 76 LAN Console Configuration 5 4 3 2 Configuring the LAN Console The LAN Console can represent up to 256 consoles on PRIMEPOWER or RM servers Of these a maximum of 63 console connections each are possible via ssh or telnet with RCA4plus RCA4 and 63 using the XSCF When configuring the LAN Console for the first time the known console accesses refe
25. network This field is only shown in advance if pabx was entered for Connection between modem and telephone network gt A further parameter required is the phone number for contacting the Teleservice center in Paderborn or Munich A symbolic name can be used here or you can also enter the number directly A symbolic name is converted by the software Ifthe number changes the assignment can be changed by the center The following symbolic names and numbers apply presently for the Teleservice centers in Paderborn or Munich Paderborn 0049 D 5 00495251829890 Munich 0049 D 2 00498936012906 The operating mode of the modem is read from the modem parameters and normally does not need to be changed gt Save the settings with SAVE Your system will now try to establish a connection to the defined Teleservice center The following screen appears during this The text on this screen is variable so the data shown below is just a snapshot 102 U41618 J Z916 1 76 Teleservice Selecting validated Teleservice modems r getting a connection via TELESERUICE examining TELESERUICE groups file get access to connection file aa CONNECT DIALOUT INIT MODEM HODEH ONLINE MODEM When the connection has been established the Teleservice center requests you to enter the required information TELESERUICE ZENTRALE PADERBORN B7201 Terminal Type Hou does this center contact your modem
26. refer helpt 25251 123456 Datatransfer with SCL ng Fili out form and save your input by pressing lt F3 gt GE SS BES Ey Ey SS a This includes gt Terminal type Here you enter the type of terminal from which you will later monitor and possibly suppress all activities that are performed on your system U41618 J Z916 1 76 103 Selecting validated Teleservice modems Teleservice Phone number of your modem This must be a number that can be reached directly from outside You only need to input the country area code because the actual number is displayed automatically The Service organization will use this number to access your system if this is necessary When you have completed the form exit this menu with the SAVE function The following screen appears At first only the first two lines appear The rest is output after a successful test this can take a while because connection establishment and the connection data are tested ERUICE ZENTRALE PADERBORN Teleservic Waiting fo n Test Montag 8 1 52 33 Uhr MET BST test vith Teleservice Center TELESERVIC PADERBORN 0 K t Press ENTER to continue Pressing ENTER takes you back to the Teleservice Administration menu Now perform the registration for the other Teleservice center You can leave the menu by selecting the EXIT function Generation and configuration ofthe Teleservice package have been completed successfully at this poin
27. the console To ensure correct key binding See VirtualBindings 3X xmbind 1X you should carry out one of the following steps beforehand gt Copy the file usr di lib bindings sun at under the name motifbind to the users home directory or add an entry with the name of the maker of the X server to xmbind alias The maker name can be ascertained with the xdpyinfo command For XVision the entry would have to be Visionware Limited sun_at gt If you are using usr dr lib bindings xmbind alias you must also set XMBINDDIR usr dt lib bindings in the profile file If you are using a private copy of xmbind alias in the home directory you must also copy usr dt lib bindings sun_at to the home directory 62 U41618 J Z916 1 76 LAN Console Switching LAN Consoles 5 6 Switching LAN Consoles The LAN Console is switched when representation of the consoles of PRIME POWER or RM servers i e console access to these systems is to be handled from another LAN Console in the future The connection to the PRIMEPOWER and RM systems involved must be established via the same RCAs from both LAN Consoles The prerequisite for this is that another LAN Console supporting the same console accesses has been configured For access to a PRIMEPOWER or RM system the port number of the RCA and on the RCA4plus and if required on the XSCF in the case of telnet or ssh connections with automatic access also the user name and password mu
28. to four simultaneous connections to each port In addition an existing connection can be taken over from a newly established connection to the same port see command Server Share on page 83 Only telnet or ssh connections may be set up to the XSCF Configuration entries for the real console connection but also entries for administration of the XSCF and for read only console connections can be created XSCF connections can be configured for the following ports in telnet mode port 23 console connection PRIMEPOWER system admin port 8010 XSCF administration access port 8011 read only console connection in ssh mode port 22 PRIMEPOWER system console connection admssh port 8810 XSCF administration access port 8811 8812 read only console connection Detailed information can be found in the XSCF documentation see Related publications on page 117 As specified in the XSCF documentation several telnet or ssh connections can be established to certain XSCF ports at the same time If such parallel connections to the RCA4plus or XSCF are also to be used from the LAN Console a corresponding number of configuration entries must be created for the same RCA4plus or XSCF port number with the mklancon command described below Because of the comparable functionality RCA4plus and RCA4 should be regarded as equivalent in the commands described below In this manual this is expresse
29. 00 2000 of the PRIMEPOWER system family The tasks of the SMC can be handled by the PW250LC Use as a LAN Console for midrange and entry level servers Up to 250 PRIMEPOWER midrange and entry level servers models 100N 200 400 600 250 450 650 850 and the RM models 300 400 600 ServerNode can be managed from a LAN Console software installation configuration OBP Powerful tools LAN Console software PRIMEPOWER ServerView Suite are available for this purpose The Remote Communication Adapter currently RCA4plus can be used as a V 24 Ethernet converter Up to 8 UNIX servers MR of Fujitsu Siemens Computers can be connected to this RCA4plus Multiple RCAs can be used on a LAN console The integrated XSCF extended System Control Facility LAN port can be used directly to administer the PRIMEPOWER models PW250 and PW450 such that no RCA is required U41618 J Z916 1 76 1 Target group Preface Use as a System Management Console SMC for enterprise servers The PVV250LC can be upgraded to a PVV250SMC and is thus suitable for use as an SMC for administering the PRIMEPOWER enterprise servers models 800 900 1000 1500 2000 2500 The System Console Software SCS installed on the SMC controls the hardware configuration and operating status of the PRIMEPOWER enterprise systems and is used for their administration partitioning with partition related console function scheduled switching on and off clock accordination via Network T
30. 16 1 76 Preface Summary of contents The chapter LAN Console from page 17 explains how to install the RCA4plus cable it and start it up It goes on to describe how to install the software on the LAN Console from the Control DVD and how to operate the LAN Console and RCA The chapter also tells you how to replace a PW250LC in the event of an error and provides support for troubleshooting and diagnostics The section RCA commands from page 70 contains an overview of the commands for the RCA4plus which are relevant for LAN Console functionality The appendix on page 95 tells you how to install and operate Teleservice and Telecall You will find other helpful information in the reference chapters Glossary from page 111 Related publications from page 117 and Index at the end of the manual Please follow all instructions in the order they appear in this manual You will avoid problems by doing so and get along faster Always pay attention to the device specific information that is supplied with the various devices U41618 J Z916 1 76 3 Notational conventions Preface 1 3 Notational conventions The follovving notational conventions are used in this manual Monospace This indicates system output e g text on a CRT or LCD screen cathode ray tube liquid crystal display Bold This indicates user inputs in examples monospace font Italics This indicates commands file names menu na
31. A with a console port Monitoring and operating of PRIMEPOWER 250 450 systems using the LAN Console therefore can be done via direct connection of the XSCF to the LAN For administration purposes the XSCF also is directly accessible via LAN The available commands and the XSCF port numbers to be used can be looked up in the XSCF documentation see information below Alternatively the console connection of a PRIMEPOWER 250 450 system can be done by an RCA via serial interface see figure 5 and figure 6 on page 25 The following applies to the complete manual all information on the XSCF especially on configuration connection establishment and amount on XSCF commands must be looked up in the XSCF documen tation i e the eXtended System Control Facility User s Guide available on the ESF Enhanced Support Facility CD the HCP Hardware Control Program CD and the User s Manual PRIMEPOWER 250 450 see Related publications on page 117 RCA4plus does not support SIDATA The RCA4plus does not support SIDATA and must therefore be installed by our Service organization The safety aspects of this process are described in the chapter Safety notes on page 5 il Distinguishing between RCA4plus and previous variants The designation RCA refers to all existing RCA types However this manual deals primarily with the functionality of the currently available RCA4plus U41618 J Z916 1 76 19 Remote Communication Adapter LAN
32. A in this initial configu ration Speed 9600 baud Word size 8 bits Parity None Stop bits 1 Flow control XON XOFF Automatic connection setup No Syntax port all set baud 9600 size 8 parity none stop 1 flow xon timeout 0 52 U41618 J Z916 1 76 LAN Console Configuration The line speed must be set to a speed of 19200 baud for every relevant port when connecting RM systems to the RCA This can be done even retrospectively with the PORT command see Port commands on page 72 Additionally for all the RCA the automatic session timeout must be switched off Syntax server cli timeout 0 If required the preset netmask can also be modified or a gateway address can be entered using the command Server Set on page 82 This terminates RCA configuration If the RCA was initialized see Init on page 30 or the command Server Init on page 80 all the parameters shown here must be set again Activate ssh mode If ssh connections are to be set up to the consoles of attached target systems via an RCA4plus the RCA must be switched to ssh mode To do this the logon via the administration access of the RCA is required see Configuring the RCA on page 51 ssh mode is activated by the following command see also RCA commands on page 70 Syntax server security encrypt ssh Here the authentication method for the RCA is created After the switchover to ssh mode de
33. AN Console 31 Configuration a opot ww ana po DEA pe gan a EE 35 Connection between LAN Console and RCA 36 Configuring the connected servers 36 Configuring the PRIMEPOWER systems 36 U41618 J Z916 1 76 Contents 5 4 2 2 5 4 3 5 4 3 1 5 4 3 2 5 4 3 3 5 4 3 4 5 4 3 5 5 4 3 6 5 4 3 7 5 5 5 6 5 6 1 5 6 2 5 7 5 7 1 5 7 2 5 7 3 5 7 4 Configuring the RM systems 38 Configuring the LAN Console and RCA 38 Initial configuration of the LAN Console and RCA 40 Configuring the LAN Console 41 Configuring the RCA saaa aaa LL LL 48 New RCA ports aoaaa aaa LL LL 54 Connecting further RCAs to the LAN Console 55 Connecting another LAN Console to the RCA 55 Modifying the LAN Console and RCA 55 Operating the LAN Console 58 Switching LAN Consoles Qu LL LL LL LL 63 Planned switches LL LL LL LL 63 Switching because of problems 63 Diagri stics Le ge 2 Ir se des Ba hee Ga ete Bat eG 64 Log tilas 3 2 ed ED EP RE Die a es BRE Ee RS 64 Status information for the monitors 65 Configuration entries for the LAN Console 65 RCA system informatio
34. CA type RCAS from 3001 3006 U41618 J Z916 1 76 43 Configuration LAN Console ssh connection RCA4 16 ports from 3101 3116 or admssh RCA4plus RCA4 8 8 ports from 3101 3108 or admssh XSCF 22 8811 8812 or admssh telnet connection or rtty connection for RCA4 plus if c option is missing RCA4 16 ports from 3001 3016 or admin RCA4plus RCA4 8 8 ports from 3001 3008 or admin XSCF 23 8011 or admin ConsoleName The symbolic system name that is going to be used This name must not yet exist It has a maximum length of 14 characters and consists of alphanumeric characters except and only The input of RCA system name should always be done in a uniform way i e always either with or without a domain suffix e g utopia not utopia xxx xxx de in order to avoid ambiguities with the rmlancon and showlancon commands If an ssh or telnet connection with option is configured for the RCA4 plus the automatic logon to the RCA4 plus is implemented with the specified RCA user name and password during the connection setup with xscon If no option was entered the user name and password are inquired from the RCA4 plus when a telnet connection is set up and the password of the RCA user Admin when an ssh connection is set up If the option is specified during the configuration of an ssh connection the automatic logon to the XSCF is made using the specified XSCF user name es
35. Console Basic descriptions in particular of the configuration and establishment of console connections still apply for the previous variants If a distinction needs to be made between the current RCA4plus and its predecessors the earlier versions are referred to as RCA3 and RCA4 or RCA4 8 RCA4 16 Detailed information on the previous versions is provided in the manual LAN Console and System Management Console see Related publications in the appendix The RCA4plus can be ordered quoting the following number RCA4plus Rack installation kit D GPRAC RCA4P D GPRAC ZB22E A3C40071339 Table 3 RCA4plus order numbers You will find the order numbers for the cables you need in the section Cable types on page 27 The RCA4plus requires the LAN Console software from Control DVD version 02 2005 No RCA4plus and XSCF connection to an Intel based LAN Console The RCA4plus or XSCF cannot be operated on the old Intel based LAN Console 20 U41618 J Z916 1 76 LAN Console Remote Communication Adapter 5 2 1 Connections on the rear of the RCA4plus LAN cables and the port cable are not included in the package and have to be ordered separately For the order numbers refer to the section Cable types on page 27 1 3 T a le A 7 N i Q LAN 4 2 Figure 2 Connections on the rear of the device 1 Serial port connectors 1 8 10 100BaseT Ethernet port RCA4p
36. For the lanconsole3 and lanconsole4 monitor no further degree of detail of infor mation can be set in the log file 64 U41618 J Z916 1 76 LAN Console Diagnostics 5 7 2 Status information for the monitors The system uses the sacadm and pmadm tools to manage the monitors lanconsole lanconsolel and lanconsole3 or lanconsole4 These tools allow the state of the monitors to be viewed and the monitors themselves to be manipulated see the manpages for sacadm and pmadm 5 7 3 Configuration entries for the LAN Console When a configuration entry is created for the LAN Console with mklancon entries are generated in the monitor specific files etc saf lanconsole _pmtab etc saf lanconsolel pmtab or etc saf lanconsole3 pmtab or etc saflanconsole4 _pmtab depending on the type of the RCA Under the specified console name the _pmtab file contains information about the device used the system name and port number of the RCA as well as monitor specific details of the type of connection This information on the configuration entries can be displayed with the showlancon command or the system tool pmadm Syntax pmadm 1 p lanconsole lanconsolel lanconsole3 lanconsole4 The mklancon configuration command also modifies the system files etc uucp Devices and etc uucp Systems A record is appended to these files for every configuration entry In turn the rmlancon tool removes such entries from the Systems and Devices files
37. MEPOWER 250 450 Hardware Control Program HCP CD Target group System administrators technicians Content May contain the updated XSCF User s Guide The CD ROM is readable on PCs and Solaris systems U41618 J Z916 1 76 127 Index Index opt SMAW SMAWxsco misc setup tpl template file 48 opt SMAW SMAWxsco sbin mklancon 41 var saf lanconsole log 64 vat saf lanconsolet log 64 vat saf lanconsole3 log 64 vat saf lanconsole4 log 64 10 100 BaseT 21 100MBps 30 17 monitor 9 21 monitor 9 2 way mirror 11 2 way mirroring 11 A abort 63 adapter 35 administration access 51 application manager 59 authentication method 84 automatic access RCA4 67 B board debug monitor 58 boot remote 7 bootp 48 57 initial configuration 40 request 40 break 59 C cable 21 console connection 27 order numbers 22 cabling 21 console 27 PRIMEPOWER 100N and RCA 26 PRIMEPOWER and RCA 23 RM 22 CCU 2 CDE 15 CLI 59 CLI port 94 command line interface 59 common desktop environment 15 configuration commands 43 LAN Console 35 RCA 35 RM 38 connect 94 RCA 94 connecting toLAN 22 to PRIMEPOWER 22 to RM system 22 connection cable 22 clearing down 59 disrupted 68 hanging 68 connector console port 21 console 7 console connection 42 RCA 59 RCA4 59 reset 66 Console Connection Unit 2 console connections 35 console input 35 console name 41 68 69 console output 35 console port 21 78 connector 21 RCA 51 Contr
38. PW250LC and RCA4plus Installation Configuration and Administration Edition October 2005 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Fax forms for sending us your comments are included in the back of the manual There you will also find the addresses of the relevant User Documentation Department Certified documentation according DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2005 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers This manual is printed on paper treated with chlorine free bleach Contents On 5 2 1 1 Preface is amp thse d E ld at ts were a ee 1 Target group 2 000000 LL Le 2 Summary of contents 2 222 2 Eon nen 2 Notational conventions 2 2 2222 LL LL LL LL LL 4 Safety notes ide cd a dee en a me ne es due eh 5 Functiona
39. U41618 J Z916 1 76 87 RCA commands LAN Console After initial configuration of ssh the ssh key is output in MD5 hash and in bubble babble under Fingerprint Show User The Show User command shows configuration data and information on the monitor in relation to existing console connections for one or all users defined in the RCA Access rights SMON or ADMIN APPLIANCEADMIN Syntax SHOW USER lt username gt ALL Parameters username User name ALL Information is displayed for all users Default Users currently logged on The Show User All command shows minimum information e g the user names and the relevant access rights for all defined users The Show User lt username gt command on the other hand displays more extensive information 88 U41618 J Z916 1 76 LAN Console RCA commands Field Content User User name Level Class of access rights If the user was assigned individual access rights the class APPLIANCEADMIN is displayed for the SCON access right the class ADMIN for the USER or PCON rights and otherwise the class user Access User s access rights Last Login System time when the user last logged on to the system Port Port number if a connection is active via the administration access CLI is shown here Username User name Duration Duration of current console connection Socket Telnet socket number of RCA From Socket IP address of LAN Consol
40. amed Fujitsu Technology So lutions This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions Contact and support addresses will now be offered by Fujitsu Technology So lutions and have the format ts fujitsu com The Internet pages of Fujitsu Technology Solutions are available at http ts fujitsu com and the user documentation at hrrp manuals ts fujitsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochtergesellschaft von Fujitsu tr gt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor l ngerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion Bitte beachten Sie dass alle Firmenbez ge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions bergegangen sind Kontakt und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form ts fujitsu com Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http de ts fujitsu com und unter http manuals ts fujitsu com fin
41. ash boot app hostip lt Address TFIP Server gt image lt Name of Image gt Removing a LAN Console gt Remove all configuration entries for example using rmlancon a The option of reconfiguration using the bootp service is canceled for each RCA4plus as follows pntadm D lt IP RCA gt lt DHCP table gt IP RCA IP address of the RCA DHCP table DHCP table in the form X X X 0 X decimal value 0 lt X lt 255 which designates the table generated with the pntadm command see Addressing the RCA in the network on page 48 dhtadm D m lt RCA gt RCA Unambiguous designation of the RCA in the DHCP configuration e g the RCA system name IP LAN Console IP address of the LAN Console gt Uninstall all software packages of the LAN Console software product Removing an RCA For every connected LAN Console remove all configuration entries for this RCA see section Diagnostics on page 64 gt For the RCA4plus also cancel support by the bootp service see above If required the removed RCA4plus can be returned to the state it was in when delivered see Switching on the RCA4plus on page 29 U41618 J Z916 1 76 57 Operating the LAN Console LAN Console 5 5 Operating the LAN Console The LAN Console can represent the consoles on PRIMEPOWER or RM servers All commands are available on each LAN Console including the following console diagnostic tools IKDB Internal Kernel Debugger BDM B
42. atic access 67 disrupted connection 68 monitor 45 not responding 66 RCA4 16 19 RCA4 8 19 75 RCA4plus 35 reinstallation 9 10 remote boot 7 Remote Communication Adapter 1 Reset 30 restart RCA 30 resume 59 RF interference 5 RJ45 27 RM configuration 38 connecting to RCA 27 port cable 27 RM600 1 rmlancon 46 65 rtty 36 40 43 59 65 rtty monitor 64 S sacadm monitors 65 safety notes 5 SCL 97 scope of delivery 9 11 PW250SMC 10 SCS 2 secure communication layer 97 secure shell see ssh 36 serial cable 96 serial ports 22 service communication 1 service organization communication 1 short circuit 6 showlancon 47 65 SIDATA 2 19 SMAWrins 31 SMAWrity 31 58 SMAWsmon 31 SMAWtelx 31 106 SMAWitssv 33 SMAWxsco 31 40 58 SMC 2 SMC see System Management Console software LAN Console 31 versions 31 software installation teleservice 96 Solaris 9 58 common desktop environment 59 Solaris8 9 SPARC processor 1 ssh 31 36 37 40 43 44 53 59 60 70 87 112 state of delivery 30 SUNVTS 9 system console 7 cabling 27 132 U41618 J Z916 1 76 Index console 1 System Console Software 2 10 system management CD see Control CD DVD 31 System Management Console 1 2 7 10 hard disk partitioning 10 T TCP IP RCA 19 teleadm 107 telecall installation 106 Telecall Gateway 1 Teleservice 1 9 teleservice reinstallation 96 software installation 96 telnet 31 36 40 43 44 51 59 60 70 template fil
43. between modem and telephone network pabx Dialing method td Guard tone none Idle state modem mode 289 Country of installation DE German d A Modem information of modem at Teleservice channel e A Parameter for registration OLR and autom defect reporting ADR f A Registration at Teleservice Center OLR g A Administer connections to Teleservice Centers h A Test Connection to a Teleservice Center i A Shou state of Teleservice Channel Fill out form and save your input by pressing lt F3 gt HELP MCHOICES README E CANCEL a EXIT gt Set the channel speed to 38400 U41618 J Z916 1 76 99 Selecting validated Teleservice modems Teleservice There are two options for connecting the modem to the telephone network Enter pabx if the modem is operated via a PABX Enter pstn if the modem is connected directly to the public telephone network gt For the dialing method you can enter td if the modem is going to operate with tone dialing or pd for pulse dialing The Guard tone and Idle state modem mode items are taken from the parameter descriptions for your modem and normally do not need to be changed Choose the country of installation with the function CHOICES gt Exit the menu by choosing SAVE The screen is then refreshed and the following messages are displayed example f Working l Modem installation is running please wait Actual firmware revision xxxxx Approved firmware revisi
44. ced Support Facility U41618 J Z916 1 76 113 Abbreviations FCC FE FSC HCP IEC IEEE IRDB LAN MAC MR NFS NTP OBP Federal Communications Commission Fast Ethernet Fujitsu Siemens Computers Hardware Control Program International Electronics Commission Institute of Electrical and Electronic Engineers Internal Kernel Debugger Internet Protocol Local Area Network Media Access Control Midrange Network File System Network Time Protocol Open Boot Prom Program 114 U41618 J Z916 1 76 Abbreviations PCI Peripheral Component Interconnect PTF Programme Temporary Fix PW PRIMEPOWER PW250LC PRIMEPOWER250 based LAN Console PW250SMC PRIMEPOWER250 based System Management Console RCA Remote Communication Adapter RMS Reliant Monitor Services RTS Request To Send RTTY Remote TeleType SCF System Control Facility SCL Secure Communication Layer scs System Console Software SMC System Management Console SPARC Scalable Processor Architecture U41618 J Z916 1 76 115 Abbreviations SSH Secure Shell SunVTS Sun Validation Test Suite TCP IP Transmission Control Protocol Internet Protocol TFT Thin Film Transistor UL Underwriters Laboratories Incorporated USB Universal Serial Bus VGA Video Graphic Adapter VTS see SUNVTS WSA Web based System Administration XSCF eXtended System Control Facility
45. commands Port Break The Port Break command sends a BREAK signal within an existing console connection via the associated serial line to the connected target system Access rights BREAK and ADMIN or APPLIANCEADMIN Syntax PORT BREAK 72 U41618 J Z916 1 76 LAN Console RCA commands Port History This command switches to history mode of the respective port for an existing console connection This can be identified by the prompt PORT HISTORY gt The content of the history buffer can now be displayed and searched through Access rights None Syntax PORT HISTORY Parameters The following commands are valid in history mode Help command Shows additional information on the commands in history mode command One of the commands explained below in history mode Bottom Shows the end of the history buffer Clear Deletes the history buffer Draw Shows the current page of the history buffer again Next Shows the next page Prev Shows the previous page Quit Returns to normal RCA command mode Resume Exits the port history mode of the command mode CLI and returns to the console window of the existing connection Search u d i string to find Search for a specified string in the history buffer string to find Character string being sought ifthe character string being sought contains blanks it must be enclosed in quotes U41618 J Z916 1 76 73 RCA commands LAN Consol
46. computer system with the Reliant UNIX 5 45 operating system 16 Reliant Monitor Services Configuration and Administration of RMS Reliant UNIX and Solaris System Administrator s Guide Target group System administrators Content This document describes the functionality configuration and adminis tration of the Reliant Monitor Services RMS 17 Reliant UNIX 5 45 High Availability System Administrator s Guide Target group System administrators Content Description of the hardware and software failover components in the RM system family 18 PRIMECLUSTER Reliant Monitor Services System Administrator s Guide Target group System administrators Content Description of configuration and administration of RMS on Solaris systems U41618 J Z916 1 76 121 Related publications 19 SIEMENS Parallel Server SPS Installation Configuration and Administration Reliant UNIX Administration Guide Target group System administrators Content This document describes software installation for the Reliant UNIX SPS and administration of a cluster that uses these features 20 RM SR2000 Systems Safety Instructions Target group System administrators technicians Content Safety instructions in 12 languages for RM systems 21 Rackvarianten Rack Variants Safety Instructions Target group System administrators engineers Content Safety instructions in 25 languages for rack systems 22 Reliant UNIX
47. console lanconsolel and lanconsole3 are activated internally in the system see command mklancon Create LAN Console configuration entries on page 43 These monitors are started and stopped via sac Service Access Control This stores status information in the var saf _log log file The monitors are identified in this log file by port monitor lt lanconsole gt port monitor lt lanconsolel gt port monitor lt lanconsole3 gt or port monitor lt lanconsole4 gt Monitor specific details i e information on the connections between the LAN Console and the RCA are stored in the var saf lanconsole log var saf lanconsolel log var saf lanconsole3 log or var saf lanconsoled log file The degree of detail of this information for the monitors lanconsole and lanconsoleldepends on the current trace level set Trace level 0 is enabled by default To set a different trace level a maximum of six levels are possible at present this must be done separately for every individual monitor using the following command rttyadm T lt eve gt lanconsole lanconsolel Error situations are logged in the basic level trace level 0 The other trace levels record additional information on the establishment and clearing down of connections and other activities on the monitor including time outs and control of access to the RCA The extended trace mode level gt 0 should only be used briefly so that the log file does not become too big
48. d by the type designation RCA4 plus 42 U41618 J Z916 1 76 LAN Console Configuration Only the term RCA4 is used in the syntax and arguments of the commands For the commands you must take into account that the RCA4plus corresponds to RCA4 8 as regards the port number range mklancon Create LAN Console configuration entries Syntax mklancon t lt RCA Type gt c lt Kind of Connection gt 1 lt RCA SystemName gt lt RCA PortNumber gt lt ConsoleName gt The command arguments determine the RCA port for which a configuration entry is to be generated t RCA Type The permitted values are 3 for the RCA3 4 for the RCA4 plus and 5 for the XSCF c Kind of Connection Console connections can be set up via ssh or telnet exclusively for the RCA4 plus and XSCF Valid entries are for ssh s for telnet t If the c option is missing the connection for RCA4 plus 1 4 is set up via rtty and for XCSF via telnet For ssh or telnet connections to the RCA RCA4 plus or XSCF the RCA user name with the associated password used for logging on to the RCA must be input during processing The default for the RCA user name is Admin RCA SystemName The system name of the required RCA RCA PortNumber A unique TCP IP port number which is served by the RCA The port number of the RCA4 plus and the XSCF is dependent on the kind of connection The port number must be in the following valid range for the R
49. d to the questions prompted during the installation with yes 6 4 1 3 Software installation on the PRIMEPOWER gt Install the Logging 3 0 software package SMAWlog3 SMAWlog3M SMAV daps component of FCS Basic Extensions from the current FSC Control DVD CD SYS MGMT SPARC gt Install the SMAWtelx Teleservice Cluster Distribution software package component of Domain Admin from the current FSC Control DVD CD SYS MGMT SPARC on all cluster nodes partitions and the SMC gt Respond to the questions prompted during the installation with yes 6 4 1 4 Software installation on the RM gt Install the SItelx software package using the pkgadd command or from the CD SYS MI via the sysadm user interface Answer the questions during installation as follows 106 U41618 J Z916 1 76 Teleservice TeleCall R You want to use DOMAIN TELESERVICE DISTRIBUTION immediately Standard n Ly n y L serect node to collect for TELESERVICE lt PW250LC SystemName gt L 6 4 2 Generating the Telecall cluster Before continuing with generation of the TeleCall cluster make sure that the SMAWtelx or SItelx software package has been installed on all machines involved and that the PW250LC has a fully functional Teleservice connection to a Siemens IT Service Teleservice center in Paderborn or Munich gt test this if you need to via the Teleservice menu submenu Simple TELESERVICE Administration
50. den Sie die Benutzerdokumentation Copyright Fujitsu Technology Solutions 2009
51. dicated kind of connection are displayed Finally the current state of the associated lanconsole lanconsolel lanconsole3 or lanconsole4 monitors is displayed e g NOTRUNNING If the a option is specified the states of all monitors are displayed assuming configuration entries exist for the associated RCA types for information on the monitors see section Status information for the monitors on page 65 U41618 J Z916 1 76 47 Configuration LAN Console 5 4 3 3 Configuring the RCA il This section is irrelevant for console connections via the XSCF To be configured successfully the RCA RCA4plus must be known and also accessible in the LAN and all serial console connections V 24 lines from the RCA to the required PRIMEPOWER or RM servers must be implemented Since the RCA does not have a keyboard or display of its own it is configured from the LAN Console For this purpose the RCA s network data is transferred to it using bootp mimicry which means that the RCA can be addressed after its initial boot i e after being powered on from the LAN Console The RCA is configured in the following stages The RCA is addressed in the network The configuration data is set in the RCA Initial configuration of the RCA4plus is different from that of the previous versions Initial configuration of the RCA4 and RCAS is described in the manual LAN Console and System Management Console Addressing the RCA in th
52. e PRIMEPOWER and RM servers can also be booted and installed remotely via LAN The PW250LC can be used as a cluster console with high availability appli cations using PRIMEPOWER and RM servers For this purpose hardware and software components may be required which are not part of the PW250LC s basic configuration The console handles the monitoring function via the network and the function of the system console for the PRIMEPOWER or RM servers connected to it Upgrading the hardware RAM and DAT drive and the System Console Software SCS enables the PW250LC to be upgraded to a PW250SMC for use also as an SMC for the PRIMEPOWER enterprise servers Connection to Teleservice A PW250SMC for administering the PRIMEPOWER enterprise servers can if the LAN Console software is used also be used as a LAN Console for administering the Midrange Systems U41618 J Z916 1 76 7 4 Preinstallation and Installation The PVV250LC is delivered vvith preinstalled operating system and predefined hard disk partitioning In terms of the disk partitioning it can therefore operate as LAN Console and as an SMC If a reinstallation is required nevertheless guidelines regarding pre installation and hard disk partitioning should be referenced This will save you the task of repartitioning if the system is upgraded to an SMC 4 1 Scope of delivery of the PW250LC The PW250LC product consists of the system unit with power supp
53. e u up The search direction up is the default setting d down The search direction down i ignore Search is performed without consideration of upper or lowercase Top Shows the top of the history buffer Port Logout You can use this command to terminate a connection assigned to an RCA port Access rights USER and ADMIN or APPLIANCEADMIN Syntax PORT lt RCA PortNumber gt LOGOUT Parameters RCA PortNumber Port numbers 1 8 If there is an opened console connection on the specified port this is closed without further prompting after a message has been issued to this effect in the associated console window If multiple active console connections exist for the port all these connections are closed Port Set You can use the Port Set command to change the settings of the RCA ports At least one of the possible parameters must be specified The changes generally come into effect the next time a connection is set up via this port Access rights PCON or SCON and ADMIN or APPLIANCEADMIN Syntax PORT lt RCA PortNumber gt ALL SET LBAUD lt baud_rate gt LSIZE lt size gt 74 U41618 J Z916 1 76 LAN Console RCA commands LPARITY lt parity gt LSTOP lt stop_bits gt LFLOW lt fTow_control gt LTIMEOUT lt time out gt LCHAR lt c 7_char gt Parameters RCA PortNumber Valid port numbers 1 8 or CON Where ALL is selected the changes affect all RCA ports Default
54. e opt SMAW SMAWxsco misc setup tpl 48 terminal emulation xterm 61 terminal type setting 37 trace level error situations 64 traffic 30 U unpacking 11 V V 24 1 27 RCA 19 versions software 31 VV web based system administration 7 starting 34 Webstart wizard 31 X XSCF 1 17 19 35 36 37 38 43 112 127 administration 66 configuration 47 console connection 56 manuals 19 monitor 45 port number 46 ssh 36 63 telnet 60 63 xscon 7 51 58 61 70 mklancon 59 xterm 61 XVision 62 U41618 J Z916 1 76 133 DE a imants Br cre RN Te Es Rat a ae ee ee Se tats ee eee Fujitsu Siemens Computers GmbH User Documentation 33094 Paderborn Germany Fax 0 700 372 00001 email manuals fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by Comments on PW250LC LAN Console and RCA4plus U41618 J Z916 1 76 DE a imants Br cre RN Te Es Rat a ae ee ee Se tats ee eee Fujitsu Siemens Computers GmbH User Documentation 33094 Paderborn Germany Fax 0 700 372 00001 email manuals fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by Comments on PW250LC LAN Console and RCA4plus U41618 J Z916 1 76 ie FUJITSU Information on this document On April 1 2009 Fujitsu became the sole owner of Fujitsu Siemens Compu ters This new subsidiary of Fujitsu has been ren
55. e switched off using its own ON OFF button Lay cables in such a way that there is no danger of people tripping over them and damaging them Do not connect or disconnect communication cables during a thunderstorm Make sure that no liquids penetrate the interior of the device risk of electric shock short circuit In cases of emergency e g damage to the housing controls or power cable or penetration of liquid turn the device off immediately remove the mains plug and notify your sales office or our Service organization This device may only be repaired by authorized personnel Unauthorized opening of the housing and inadequate repairs may pose a considerable danger for users electric shock risk of ignition U41618 J Z916 1 76 3 Functionality The PVV250LC can be used as a LAN Console to administer Solaris UNIX midrange and entry level servers of Fujitsu Siemens Computers It offers the following properties ltcan be used for installation configuration administration and diagnostics management of one or more connected PRIMEPOWER and RM servers All functions of a character oriented display including IKDB Internal Kernel Debugger and BDM Board Debug Monitor or OBP Open Boot Prom Monitor and the rebooting of a system can be carried out from the PW250LC The xscon tool is used to select and represent one or more consoles of PRIMEPOWER and RM servers Support for PRIMEPOWER ServerView Suit
56. e Internet under http serviceportal sbs de technics technics swserv reliant teleserv teleserv_en htm U41618 J Z916 1 76 95 Installation and generation Teleservice 6 1 Installation and generation Hardware installation The following hardware is needed for Teleservice Ahigh speed modem A serial cable An adapter A telephone cable A power supply unit A power supply cable The modem is connected via a serial connection cable to the free ttyb port on the PW250LC The system should be turned off when connecting the modem Please refer to the documentation for the modem for information on installation and operation Use the Western lt gt TAE cable for the modem telephone connection The Western connector is inserted in the modem and the TAE connector in the telephone connection socket Note that the TAE connector will only fit in a TAE socket that has an N interface A telephone is normally connected to an F interface and is coded differently There are also TAE sockets to which a telephone and a modem can be connected In this case the modem is connected on the left and the telephone in the middle The modem has a low voltage on one side Before connecting the power supply unit to the modem make sure the low voltage switch is off Finally plug the power supply unit into a normal 230 V mains socket and turn the low voltage switch on again Software installation The Teleservice package is pr
57. e administered system If the console of a PRIMEPOWER 250 450 is not connected via Port A but via the XSCF re configuration for this console access has to be done according to the XSCF documentation see PRIMEPOWER publications on page 123 Here the XSCF configuration is done using the Machine Administration Menu provided by ESF The essential configuration steps for telnet and ssh connections are configure network settings for the XSCF create an XSCF user with root rights If necessary create a user Admin according to the RCA see also the section mklancon Create LAN Console configuration entries on page 43 ssh activate console access via LAN If a PW250LC with ssh is to access the XSCF or the RCA4 it must support ssh This can be implemented using OpenSSH of the Control DVD for Solaris 8 or using the ssh which is available by default for Solaris 9 and Solaris 10 In addition further XSCF settings have to be made for ssh connections using ESF commands see ssh administration in the XSCF User s Guide appendix Related publications on page 117 If a secure console connection is to be used via ssh also the connections to the XSCF and to the additionally available read only console only should also be configurable via an ssh connection for security reasons see ssh administration in the XSCF User s Guide appendix Related publications on page 117 U41618 J Z916 1 76 37 Configuratio
58. e is given the default name tmp XSCON_ lt ConsoleName gt The log file will be created and stored on the system on which xscon was started If the SMAWtssv package has also been installed you can choose from a menu whether or not you want to use Teleservice A console window is opened for each connection Ifthe connection to the RCA cannot be established within 10 seconds an error message is output and the console window is closed If connections via ports 9 16 were configured for an RCA4plus the following error message is output in the opened console window Connect failed CAN T ACCESS DEVICE and the console window is closed When you execute xscon ConsoleName the connection to the selected system is set up directly xscon only supports the xterm terminal emulation To be able to operate display dependent applications on a PRIMEPOWER or RM server console the TERM environment variable must be set appropriately U41618 J Z916 1 76 61 Operating the LAN Console LAN Console TERM xterm Resources You can use the normal resources to configure the emulation windows that are to be started The instance name of these emulation windows is xscon and their class name is XTerm Example Entry in Xdefaults to configure the font on the console terminal xscon font lucidasanstypewriter 14 The xscon command can also be started under an X terminal emulation e g XVision from a terminal that is not connected directly to
59. e network The RCA is made accessible in the LAN by means of bootp mimicry To permit this the LAN Console must be made available as a bootp server for the RCA to be configured This is done by using the Solaris system commands dhcpconfig dhtadm and pntadm see also the manpages If no dhcp or bootp service has yet been configured on the LAN Console the following steps must be performed Initial configuration of the dhcp service dhcpconfig D r SUNWfiles p var dhcp generates the var dhcp folder the global DHCP table var dhcp SUNWyiles1_dhcptab and the configuration file etc inet dhcpsvc conf and starts the dhcp service Configuration of the bootp service under dhcp The following line is added to the dhcp configuration file etc inet dhcpsvc conf 48 U41618 J Z916 1 76 LAN Console Configuration BOOTP_COMPAT manua 1 You use the following command to create the DHCP table for the LAN segment to which the LAN Console and the RCA belong pntadm C lt IP LAN Console gt IP LAN Console IP address of the LAN Console A table with the logical name X X X 0 is generated X decimal value 0 lt X lt 255 i e the file war dhep SUNWfilesIX_X_X_0 The name is derived from the netmask for the LAN segment in accordance with the entry etc inet netmasks on the LAN Console The bootp configuration must now be performed for the RCA to be configured Execute the following commands for further RCAs which a
60. e of the PRIMEPOWER or RM system is possible with ssh Secure Shell An ssh connection is also possible for PRIMEPOWER 250 450 systems via the XSCF Version 2 of the ssh protocol SSH2 is supported telnet unencrypted kind of connection between LAN Console and RCA4 or XSCF Console connections via ssh or telnet can be configured only for RCA4plus XSCF and RCA4 If console connections via the RCA4 are set up via rtty i e not via ssh or telnet for security reasons the RCA must be connected in the private LAN 5 4 2 Configuring the connected servers 5 4 2 1 Configuring the PRIMEPOWER systems A V 24 cable is used to make the connection at the serial port to the required port on the RCA in accordance with the description in the section Serial port for connecting the console on page 22 the Cable types on page 27 and the definition in mklancon Create LAN Console configuration entries on page 43 36 U41618 J Z916 1 76 LAN Console Configuration The line speed for the RCA ports is set by default to 9600 baud see PORT commands in the section RCA commands The terminal type needs to be set for the console login for all PRIMEPOWER systems gt Inthe erc inittab file set the terminal type xterm in the entry for the console login usr lib saf ttymon g d dev console T xterm l console Configuring the PRIMEPOWER 250 450 server i Not the PW250LC itself is meant here but th
61. e with socket number in brackets U41618 J Z916 1 76 89 RCA commands LAN Console 5 9 2 5 User commands User Add The User Add command creates a new user entry in the RCA In addition to a password every user is assigned specific access rights to the RCA commands As soon as this command has been terminated successfully the new user can access the RCA in the framework of his her defined access rights A maximum of 64 users can be administered in the RCA Access rights USER or ADMIN APPLIANCEADMIN Syntax USER ADD lt username gt LPASSWORD lt passwora gt J LACCESS lt access gt Parameters username User name comprising 3 16 alphanumeric characters case sensitive password User password comprising 3 16 alphanumeric characters case sensitive access Access rights or classes for RCA command groups Several access rights can be assigned at the same time though these must be separated by commas The valid values are 90 U41618 J Z916 1 76 LAN Console RCA commands P lt n gt Authorized to set up console connections for the specified port number n P lt x y gt Authorized to set up console connections for the specified port numbers in the range x to y PALL Authorized to set up console connections for all ports USER Authorized to create and delete users as well as to change user data PCON Authorized to modify the port settings SCON A
62. einstalled at the factory To reinstall the package first install the Teleservice SMAV tssv package from the FSC Control DVD with the pkgadd command 96 U41618 J Z916 1 76 Teleservice Generating the softvvare 6 2 Generating the software The screens depicted in this section show a sample configuration Since some screens depend on the parameters that have been input the generation process may involve some different screen texts or different screens Logging in gt Log in under a user ID with root privileges and issue the teleadm command from the shell You will see the following start screen ARNUNG ELESERVICE SCL Secure Communication ayer ist noch nicht installiert enn Sie Ihre Kommunikationsverbin ungen abhoersicher betreiben wollen ollten Sie obige Software instal lieren Wenn Sie sich bei einer TELE ERYICE Zentrale registrieren lassen ollen und die Verbindung mit SCL ge ahren werden soll muessen Sie es stzt tun Sie duerfen es jedoch nur un wenn strenge Kryptographie in Ihrem Land erlaubt ist itte fortfahren mit Eingabe von WARNING TELESERVICE SCL Secure Communication Layer is not installed currently If you don t want your connection to be monitored you should install the software mentioned above IT you want register yourself at a TELESERYICE center and this connection will use SCL you have to install SCL nou You are only allowed to install SCL ir strong cryptography i
63. em also includes infor mation on operating the SMC U41618 J Z916 1 76 125 Related publications 36 37 PRIMEPOWER Solaris 2000 User s Guide Target group System administrators Content User Guide for the PRIMEPOWER 2000 system PRIMEPOWER Solaris 900 1500 2500 User s Guide Target group System administrators Content User Guide for the PRIMEPOWER 900 1500 2500 system Online Literature on PRIMEPOWER 38 39 PRIMEPOWER Solaris System Console Software SCS User s Guide PRIMEPOWER 2500 2000 1500 1000 800 900 Target group System administrators Content Description of the software used on the System Management Console PRIMEPOWER Solaris Installation Guide System Console Software Target group System administrators Content Special notes on using System Console Software on Fujitsu Siemens equipment 126 U41618 J Z916 1 76 Related publications 40 PRIMEPOWER Solaris PRIMEPOWER 900 1500 2500 Hardware Control Program HCP CD PVV900 COLME HCP PW1500 COLOE HCP PW2500 COLLE HCP PW650 COLMM HCP Target group System administrators technicians 41 PRIMEPOWER Solaris Enhanced Support Facility ESF Manuals amp Patches for Solaris Operating Environment Target group System administrators technicians Content Contains the XSCF User s Guide among other things The CD ROM is readable on PCs and Solaris systems 42 PRIMEPOWER Solaris PRI
64. emName gt adm in telnet mode or lt RCA SystemName gt admssh in ssh mode Access can also be enabled if required using the telnet or ssh command Syntax telnet lt RCA SystemName gt or ssh Admin lt RCA SystemName gt RCA SystemName The system name of the desired RCA In telnet mode afterwards the desired user name in general Admin and associated password or in ssh mode only the password for Admin should be entered Furthermore the RCA command interface can also be accessed within an opened console connection i e from the console window via the CLI access sequence This is the sequence CTRL and as described in the section Configuring the RCA This type of access is particularly essential for sending a BREAK and for displaying the history of the characters received 70 U41618 J Z916 1 76 LAN Console RCA commands 5 9 1 Access rights Certain user dependent rights are necessary in order to execute RCA commands in other words to configure and administer the RCA The typical Admin user has access rights for all RCA commands Each individual user can be assigned several of the rights listed below see the section User commands PCON Authorized to modify port settings of the RCA SCON Authorized to configure the RCA SMON Authorized to display RCA status information USER Authorized to create and delete users as well as to change user data BREAK Authorized to send a BREAK signal
65. ents and reactions are described in event and reaction definitions You can display and edit these definitions using the event management functions under PRIMEPOWER ServerView Suite gt Diagnose The events are stored under SLOGPATH filters and the reactions are stored under LOGPATH reactions For more information about error management with TeleCall refer to the manual Error Diagnostics and Troubleshooting The following software packages allow you to configure a TeleCall cluster for computers that can be reached from the PW250LC SMAWtelx Domain Teleservice Distribution for Solaris SItelx Domain Teleservice Distribution for Reliant UNIX U41618 J Z916 1 76 105 TeleCall Teleservice 6 4 1 Installing Telecall 6 4 1 1 Preparations gt Draw up a list of the node names of all machines that are to belong to the TeleCall cluster Check whether all machines in the above mentioned list can be accessed from the PW250LC for example using ping lt NodeName gt 6 4 1 2 Software installation on the PW250LC gt Install the Logging 3 0 software package SMAWlog3 SMAWlog3M SMAV daps component of FCS Basic Extensions from the current FSC Control DVD CD SYS MGMT SPARC The software package is then installed automatically gt Install the SMAWtelx Teleservice Cluster Distribution software package component of Domain Admin from the current FSC Control DVD CD SYS MGMT SPARC gt Respon
66. erv reliant telecall telecall_en htm or by calling your Service hotline 0180 5 2202 in Germany and quoting the keyword TeleCall Contact person Here you enter the name s of one or more of your employees who can be contacted about the system if a connection cannot be established some time Their phone and fax numbers are also helpful gt Additional information can be entered under Remark Once you have filled in the form save the settings with the SAVE option Window 2 appears Install Teleservice channel The registration must be done for both Teleservice centers Munich Paderborn Choose f for regis tration and confirm the initial registration for Index 0 U41618 J Z916 1 76 101 Selecting validated Teleservice modems Teleservice b in J Install and administe First Time Registration C Remote operating with log Files tabase store database m Ay nel co pe ru da Telephone number f Hodem mode goo reparting ADR i l Fill out form and save your input by pressing lt F3 gt HE Ess ee na PB CANCEL BICMO MENUM EXIT Parameters are entered in this window which can be used to contact the TELESERVICE center in Munich or Paderborn Enter far under Telephone number if the Teleservice center does not lie in your local telephone network The parameter near may apply for you if you are in the Munich or Paderborn local public
67. ery is re established Before the use of INIT it is recommended to note the MAC address to be able to reconfigure the system Reset Interrupts operation of the RCA and reboots it while retaining the set values 100MBps lights up if the RCA is connected to a 100 MBps LAN TRAFFIC lights up when there is data traffic LINK LED lights up if the RCA detects that it is connected to a network ONLINE LED lights up does not flash if the self test and the initialization phase of the RCA are run through successfully If the ONLINE LED flashes for approx 1 minute after it is switched on an error has occurred in the self test or during initialization POWER LED lights up if the RCA is connected to the power supply system 30 U41618 J Z916 1 76 LAN Console Installing software packages on the LAN Console 5 3 Installing software packages on the LAN Console The LAN Console software needs no more than 10 MBytes of storage space The LAN Console software is stored on the Control DVD The following packages are relevant for the LAN Console Package SMAWrtty communication SMAWxsco console mapping SMAWrins remote installation server SMAWtelx Telecall gate SMAWsmon Secure Device Monitor The LAN Console supports the connection setup via ssh secure shell and telnet During installation of software you may be instructed to install the required ssh Select PRIMEPOWER ServerView Su
68. es must be generated using the mklancon command Access rights SCON or APPLIANCEADMIN Syntax SERVER SHARE DISABLE AUTO QUERY Parameter DISABLE No shared connections to a port are possible AUTO Depending on the user rights simultaneous shared connections to a port are possible These are implemented without the agreement of the user of the connection that is already active QUERY Depending on the user rights simultaneous shared connections to a port are possible These are implemented without the agreement of the user of the connection that is already active Depending on the users access rights all options enable an existing connection to be replaced by one that has been newly set up Default QUERY U41618 J Z916 1 76 83 RCA commands LAN Console Server SSH The Server SSH command enables or disables ssh mode of the RCA If you enable ssh mode for the first time RCA authentication method is generated At another session the specified authentication method is used by default But it is also possible to generate a new authentication method This procedure may require some minutes When you enable ssh all console connections will be terminated If connections to the RCA were activated using the Server Security telnet command both ssh and telnet connections to the RCA are possible after the ENABLE option is used Access rights SCON or APPLIANCEADMIN Syntax SERVER SSH ENABLE DISABLE Paramete
69. eservice connection This is 0 on many PABXs The fields are not filled in for direct connections to the public telephone network Save these settings by choosing SAVE 98 U41618 J Z916 1 76 Teleservice Selecting validated Teleservice modems 6 3 Selecting validated Teleservice modems If you are connecting a different modem the CHOICES function will show you a list of all validated modems and you can choose the right one If there are several entries for one modem type choose the one with the highest suffix Select ENTER to exit the next screen 1 5 Robotics S Robotics 56K Message Modem S Robotics 56K Voice Faxmodem j om U S Robotics COURIER I modem ALTOS AM14400F ALTOS AML44 0TF BELGACOM U3232B T1 CPU Delta 14 4 Fax CPU Pico T Plus Fax belg p cpu delt epu pieo f eres icli crea mOC BX CREATIX LC 144 UF CREATIX SG 2834 DATABOX AX 2424c Dr Neuhaus FURY 19 2 TI Dr Neuhaus SMARTY 14 4 TI EEH Elink 323 DIGITAL ANALOG ISDN EEH Elink 324 ANALOG analog ae i ing AER i eeh elint Move cursor to desired menu item and select it by pressing lt F3 gt U E p EOADME PR CaNceL ENT gt When window 2 Install Teleservice channel is opened again choose option b Install Modem for Teleservice channel Teleservice modem mt S634zba 4 Device name of Teleservice Channel dev term b TTY Baud Rate 38400 Connection
70. fast access to the Service organization and gives Service fast selective access to your system where necessary The following is needed for Teleservice High speed modem with the necessary cabling and installation instructions A mains power supply 230V A telephone connection TAE near the system The Teleservice software provided on the FSC Control DVD Since multiple PRIMEPOWER or RM servers can be administrated from the PW250LC fewer modems are required The modem is not included with the PW250LC product The software comes with detailed information that you can find under gt y A Information in the administration interface There is also a HELP function for every menu item A CHOICES function is available when there are several options You can order manuals for the Teleservice software from your sales partner Preparatory work for Teleservice Some preliminary work is needed before getting Teleservice started but any user with some technical skill can do this with the aid of these instruc tions and the online help Contact the technician responsible for installing your system if you do not want to do this preliminary work yourself If you encounter a generation or registration problem in the course of instal lation call your SIEMENS IT Service hotline and report your Teleservice problem in Germany the number for the Siemens IT Service hotline is 0180 5 2202 You can find out more about Teleservice on th
71. iant UNIX 5 45 Network Administration Description Target group System administrators Content Description of the configuration and administration of networks 11 Reliant UNIX 5 45 Networking Reference Manual Reference Manual Target group System administrators programmers Content Quick reference for commands functions utilities and system files which are required for working with networked computers U41618 J Z916 1 76 119 Related publications 12 13 14 Reliant UNIX 5 45 RM600 E Operating Instructions Target group System administrators Content This document provides information on the multi user RM600E computer system running under Reliant UNIX 5 45 Reliant UNIX 5 45 RM600 E40 E42 E80 CS42 Operating Instructions Target group System administrators Content This document provides information on the models E40 E42 E80 and CS42 on the multi user RM600 computer system running under Reliant UNIX 5 45 Reliant UNIX 5 45 RM600 E45 E85 CS45 FC45 Operating Manual Target group System administrators Content This document provides information on the models E45 E85 CS45 FC45 on the multi user RM600 computer system running under Reliant UNIX 5 45 120 U41618 J Z916 1 76 Related publications 15 Reliant UNIX 5 45 RM ServerNode Operating Manual Target group System administrators Content Description startup and operation of the RM ServerNode multiprocessor
72. ime Protocol NTP email messaging to the system administrator in case of error Depending on its main memory configuration the SMC can be used for multiple enterprise servers in parallel Details of the PW250SMC hardware and on handling the System Console Software SCS functionality are provided in the documentation see PRIME POWER publications in Related publications 1 1 Target group This manual is targeted at system administrators Knowledge of Solaris and if possible Reliant UNIX systems is required If any problems occur with the PW250LC the connected systems or the RCA4plus during system operation please contact your local Service organization LAN Console and RCA4plus are not SIDATA compatible The PW250LC and RCA4plus do not support SIDATA i e they must be installed and started up by a technician System administrators are given instructions on installing and configuring them 1 2 Summary of contents Safety notes It is essential to read the chapter Safety notes from page 5 before starting to work with the PW250LC This chapter contains essential infor mation for proper installation and handling of this device This manual describes how to install the PW250LC and the RCA4plus and explains how to configure and operate the PW250LC as a LAN Console The chapter Preinstallation and Installation from page 9 tells you everything about preinstallation and hard disk partitioning of the PW250LC 2 U41618 J Z9
73. ion entry for one of the monitors lanconsole lanconsolel lanconsole3 or lanconsole4 is deleted this monitor is closed 46 U41618 J Z916 1 76 LAN Console Configuration showlancon Show the specified configuration entries Syntax showlancon lt RCA SystemName gt t lt RCA Type gt lt RCA SystemName gt lt RCA PortNumber gt n lt ConsoleName gt a t lt RCA Type gt t lt RCA Type gt c lt Kind of Connection gt L lt RCA SystemName gt The command arguments determine which configuration entries are to be displayed RCA SystemName All configuration entries belonging to the specified RCA are displayed RCA PortNumber If a configuration entry is found for the specified TCP IP port number on the RCA4 plus or the XSCF admin or admssh is also possible which is served by the specified RCA it is displayed n ConsoleName The configuration entry belonging to the specified symbolic system name is output a All configuration entries of all RCA types on the LAN Console are displayed t RCA Type The permitted values are 3 for the RCA 4 for the RCA4 plus and 5 for the XSCF All of the configuration entries on the LAN Console of the specified RCA type which may fulfill the further conditions are displayed c Kind of connection The permitted entries are t for telnet and s for ssh exclusively for the RCA4 plus and XSCF Only configuration entries of the in
74. ion of an SMC PRIMEPOWER Solaris Model 200 Installation Instructions Target group Technicians Content Installation instructions for the PRIMEPOWER M200 system PRIMEPOWER Solaris Model 400 Installation Instructions Target group Technicians Content Installation instructions for the PRIMEPOWER M400 system PRIMEPOWER Solaris Model 600 Installation Instructions Target group Technicians Content Installation instructions for the PRIMEPOWER M600 system PRIMEPOWER Solaris Model 200 Maintenance Manual Target group Technicians Content Service Manual for the PRIMEPOWER M200 system 124 U41618 J Z916 1 76 Related publications 31 PRIMEPOWER Solaris Model 400 Maintenance Manual Target group Technicians Content Service Manual for the PRIMEPOWER M400 system 32 PRIMEPOWER Solaris Model 600 Maintenance Manual Target group Technicians Content Service Manual for the PRIMEPOWER M600 system 33 PRIMEPOWER Solaris 850 650 User s Guide Target group System administrators Content User Guide for the PRIMEPOWER 850 650 rack systems 34 PRIMEPOWER Solaris 250 450 User s Guide Target group System administrators Content User Guide for the PRIMEPOWER 250 450 system Also contains infor mation on XCSF 35 PRIMEPOWER Solaris 800 1000 User s Guide Target group System administrators Content User Guide for the PRIMEPOWER 800 1000 syst
75. ion set up to the RCA 86 U41618 J Z916 1 76 LAN Console RCA commands Show Server CLI This command shows the settings for RCA command mode CLI Access rights SMON or ADMIN APPLIANCEADMIN Syntax SHOW SERVER CLI The following information is important in the context of the functionality of the LAN Console Field Content CLI Port NONE This port is used exclusively for console connections in the framework of LAN Console functionality see Configuring the RCA on page 48 Access Control character for invoking CLI mode from an active Character console connection see Configuring the RCA on page 48 History Specifies whether the content of the history buffer of a port should be displayed AUTO or not HOLD at connection setup or whether the buffer content should be retained KEEP or cleared CLEAR at connection setup see Server commands on page 78 Server CLI Displays the timeout time set see Server CLI Timeout commands Show Server Security The Show Server Security command displays the current information relating to user authentication and data encryption see also Server Security on page 81 and Server SSH on page 84 Access rights SMON or ADMIN APPLIANCEADMIN Syntax SHON SERVER SECURITY If the RCA is working in ssh mode the output of Encryption displays the value SSH In telnet mode the output None is displayed here
76. ite either at shell level or at desktop level Starting at shell level You start the user interface in write mode by entering the following at command level opt SMAW bin wsa lt hostname gt The welcome screen then appears and you proceed as described there language setting root password If you only want to invoke the user interface in read mode enter the following opt SMAW bin wsa read only lt hostname gt A dialog box then appears and you proceed as described there user name root password language setting etc Starting at desktop level You will find the PRIMEPOWER ServerView Suite application on the desktop in the Workspace Menu under Applications gt Application Manager gt System_Admin gt WebSysAdmin 34 U41618 J Z916 1 76 LAN Console Configuration 5 4 Configuration In order to be able to configure the system the LAN Console must have been connected to the RCA via the LAN and the RCA must have been connected to one or more PRIMEPOWER or RM servers via a serial port see figure 2 on page 21 Alternatively the LAN Console can also be connected to the XSCF of a PRIMEPOWER250 or 450 system via LAN From the LAN Console the system administrator manages both the RCA or the XSCF and the console connections of the attached PRIMEPOWER or RM servers il Distinguishing between available RCA types This manual deals primarily with the configuration of the current RCA4plus described in
77. ite if the LAN Console is to be integrated in the ServerView cluster Installation procedure Insert the Control DVD The required packages are installed using the Webstart wizard The File Manager window opens automatically showing the contents of the DVD U41618 J Z916 1 76 31 Installing software packages on the LAN Console LAN Console File Selected View El Es E go up documents EE Mo products README_de htm README en html Ri Installer Figure 10 File Manager window for the Control DVD gt Double click Installer and click the Next button until you see the following mask Select the type of installation you want for each product No Default Custom Product Install Install Install FSC Basic Extensions PRIMEPOWER ServerView Suite ARMTech Domain Admin EMANATE Masteragent LAN Console II SPARC ESCoD TD52 DDDDDDLL Sake rene ene ne lt Back Next gt Figure 11 Installation mask for the Control DVD gt Choose the product LAN Console Il SPARC Default Install The following packages are installed in the opt SMAW directory 32 U41618 J Z916 1 76 LAN Console Installing software packages on the LAN Console SMAWrtty SMAWrins SMAWtelx SMAWxsco SMAWsmon If you want to use the LAN Console to administer several systems simulta neously in one or more domains you should also install the licensed Domain Admin 2 1
78. le with the same parameter settings You can check the necessary information about existing configuration entries with the showlancon command The entries on the new LAN Console are again created with mklancon see the section Configuring the LAN Console on page 41 5 4 3 7 Modifying the LAN Console and RCA The following sections outline the approach to modifying a configuration entry on the LAN Console and the RCA4plus The steps for removing a LAN Console or RCA configuration are also outlined Modifying the configuration entry for an RCA port Remove the configuration entry with rmlancon and use mklancon to create the modified configuration entry If an ssh or telnet console connection with automatic access to the RCA4plus or the XSCF option was configured with mklancon compare section mklancon Create LAN Console configuration entries on page 43 the entered password can be changed if required U41618 J Z916 1 76 55 Configuration LAN Console Syntax Rey create p lanconsole3 lanconsole4 s lt ConsoleName gt ConsoleName is the symbolic system name of the target system vvhich the console connection vvas configured for The relevant monitor option p for console connections via RCA4plus is lanconsole3 and for connections via XSCF lanconsole4 The relevant monitor can also be found out by entering the command showlancon n lt ConsoleName gt Accordingly for an ssh or telnet connectio
79. lity 2 22 22 0m nn 7 Preinstallation and Installation 9 Scope of delivery of the PW250LC 9 Preinstallation of the PW250LC 9 Use a3 5MG 2 geni aa ae ga te ee Egea nn dl 10 Hard disk partitioning 2 22 220m 10 Unpacking and checking the delivery unit 11 Install and detach mirroring Q Qu nn 11 Mirroring the root and swap filesystems 13 Detach mirroring of the root and swap filesystems 14 First Dooi 3 sus a ete we ee eee ea EE 15 LAN Console Ce 17 Architecture 24 405 ie da aR dos ea de dosi km 17 Remote Communication Adapter 19 Connections on the rear of the RCA4plus 21 LAN connection LL LL 21 RCA4plus CONSOLE PORT Qu 21 Serial port for connecting the console 22 Cable types lt i eni En Eraser Ed d Els Boe DE da dE ol 27 Technical specifications of the RCA4plus 28 Power ratings oaoa LL LL 28 Environmental conditions 28 Dimensions and weights 2 2 nn 28 Standards 2 2 244 pa ch au ms ma den anne pe de 8 29 Conformity tests o oo LL Le 29 Approvals i aoe mi meer Em a a de A AS 29 Switching on the RCA4plus Qu LL LL 29 Installing software packages on the L
80. lus CONSOLE PORT Bo Ou D Power supply Caution The power supply should be easily accessible 5 2 1 1 LAN connection The RCA4plus has a 10 100BaseT Ethernet port see figure 2 for connection to the LAN 5 2 1 2 RCA4plus CONSOLE PORT For administration and configuration of the RCA4plus also the RCA4plus CONSOLE PORT may be used The settings are the same as for the RCA ports see Configuring the RCA on page 51 U41618 J Z916 1 76 21 Remote Communication Adapter LAN Console 5 2 1 3 Serial port for connecting the console The RCA4plus has 8 serial port connectors and can thus connect up to 8 servers Transmission rate 50 Baud to 115 2 Kbit s Once you have positioned the RCA in a suitable location or installed it in the rack gt connect the RCA to the LAN connect the ports to the server system using the appropriate cable as shown in the next diagrams Cables must not prevent the rear door from closing Always make sure when connecting cables that the rear door of the system cabinet can be closed again effortlessly Secure the connector by tightening its screws Connecting to the RM server Figure 3 Connecting the RCA to the backplane of the device in this case an RM 600 E45 model gt Connect the cable to the connector which is at the top of the basic HIOS or EHIOS basic controller 9 pin 22 U41618 J Z916 1 76 LAN Console
81. ly cable the Solaris Media Kit the CDs for the Enhanced Support Facility ESF and patches PTF CD plus the Control DVD with the LAN Console software 4 2 Preinstallation of the PW250LC The PW250LC is preinstalled as follows Component Preinstallation Operating system Solaris 8 9 or 10 Entire distribution plus OEM Support 64 bit incl Disk Suite SUNVTS ESF Patches Current PTF CD and or Recommended Patch Cluster RS Cluster Teleservice V4 0 Language German English is installed automatically as well Table 1 Preinstallation of PW250LC U41618 J Z916 1 76 9 Preinstallation of the PVV250LC Preinstallation and Installation 4 2 1 Use as SMC To enable the PW250LC also to operate as an SMC the System Console Software SCS must be used in addition to the required hardware configu ration Installation must be performed as described in the Installation Guide System Console Software see Online Literature on PRIMEPOVVER on page 126 and in particular the ESF software must be deinstalled beforehand 4 2 2 Hard disk partitioning The following hard disk partitioning is predefined Partition Folder Hard disk partitioning 0 root overlap swap 64 MByte 1 swap 4096 MByte 2 overlap Entire disk 3 4 5 6 32 MByte as metadevice 7 32 MByte as metadevice Table 2 Hard disk partitioning With this hard disk parti
82. m the entry under DEVICE from the output of the command showlancon n lt ConsoleName gt ConsoleName is the symbolic system name of the target system If there is still no output in the console window the following command should be executed on the connected system e g using the rlogin command echo 021 c gt dev console 5 8 5 Invalid administrator password for RCA4plus An RCA4plus can only be configured by the user Admin If the valid password is not known for this user the RCA4plus must be initialized section Switching on the RCA4plus on page 29 and then re configured section Configuring the RCA on page 48 U41618 J Z916 1 76 69 RCA commands LAN Console 5 9 RCA commands This section describes only the properties of the RCA4plus Functionality and configuration of the XSCF are described in the XSCF documentation see Related publications on page 117 Accessing the RCA command interface The commands for configuring and administering the RCA4plus can be executed in the Command Line Interface CLI of the RCA4plus The RCA works either in telnet mode for console connections via telnet and rtty or in ssh mode for console connections via ssh The CLI is accessed from the LAN Console using the xscon command Syntax xscon lt RCA Administration Access gt RCA AdministrationAccess Administration access to the RCA4plus created using mkrca generally referred to as lt RCA Syst
83. menu item Test Connection to a Teleservice Center TELESERVICE CENTER PADERBORN MUNICH Note that this function can only be used in conjunction with the support center that is responsible for you see the introduction to the section TeleCall The TeleCall cluster now has to be generated on the PW250LC 1 Log in to the PW250LC under a user ID with root privileges and start the teleadm command from the shell You will see the following start screen U41618 J Z916 1 76 107 TeleCall Teleservice TELESERUICE administration A Connect to Center Information Service CIS A Operate Teleservice session A Common adjustments A Install Teleservice channel A Install and administer Teleservice center C A A com Ta ho an Remote operating with SINIX TE Analyze log files Manage database Aj Insta M A Install modem for Teleservice channel A Reinstall modem and automatic repair A Modem information of modem at Teleservice channel Parameter for registration OLR and autom defect reporting ADR f A Registration at Teleservice Center ULR g A Administer connections to Teleservice Centers h i u foe A Test Connection to a Teleservice Center Show state of Teleservice Channel Move cursor to desired menu item and select it by pressing lt F3 gt LES a I a ON CANCEL SE EXIT gt Enter the identification number of the PW250LC in wind
84. mes and inputs in continuous text Bold This indicates emphasis in the text Key This indicates keys or key combinations in continuous text i This indicates additional information and tips Title This indicates information which if not heeded may jeopardize your health the functioning of your system or the security of your data gt This indicates a step that you have to perform gt This indicates the last possible solution to a problem or the last step in a flow chart e This character and the one below Symbolizes itemized lists 4 U41618 J Z916 1 76 2 Safety notes This section gives advice on safety that you have to heed when using your PW250LC and the RCA Further safety information you will find in the PW250 450 User s manual The devices comply with the relevant safety regulations for information technology equipment including electrical machines for use in office environ ments Please contact your local sales office or our Service organization if you are in doubt about whether the device can be installed in the environment you envisage Please also observe the safety instructions for GP 7000F PRIMEPOWER Systems see Related publications provided with every device Radio Frequency Interference Statement RCA e The following notice is for EU users only This is a product that meets European standard EN55022 e The following notice is for USA users only This equipment has been tested and found to co
85. mirroring which basically involves keeping two copies of all data saved to the hard disk In this way even if one copy is lost the other will remain ensuring that no data is lost NIS Network Information Service Central administration of configuration information in a network For instance IP addresses security details mail Ethernet interface configurations and other network services can be administered or provided centrally OBP OpenBoot PROM OpenBoot PROM software SIDATA System installation done by the user Solaris UNIX operating system by SUN U41618 J Z916 1 76 111 Glossary SSH Secure Shell Provides encryption mechanisms for network services XSCF Extended System Control Facility The System Control Facility is a dedicated set up on the systemboard of the PRIMEPOWER 250 450 with an independent CPU the service processor XSCF guarantees a unique monitoring of the system and controls the status of fans power supply and other system components and peripherals 112 U41618 J Z916 1 76 Abbreviations BDM Board Debug Monitor BIOS Basic Input Output System CCU Console Connection Unit CLI Command Line Interface CPU Central Processing Unit CSA Canadian Securities Administrators CTS Clear to Send DHCP Dynamic Host Configuration Protocol DNS Domain Name Service DTR Data Terminal Ready signal EMC Electromagnetic Compatibility EN European Norm ESF Enhan
86. mmand was called for precisely one port and a console connection is set up for this port at this time U41618 J Z916 1 76 85 RCA commands LAN Console Show Server The Show Server command displays configuration and statistics information for the RCA on the monitor Access rights SMON or ADMIN APPLIANCEADMIN Syntax SHOW SERVER The output of the Show Server command is explained below Field Content Server IP address of RCA Mask Subnet mask Gateway IP address of gateway system if specified Up Time Time day hours minutes and seconds since the last RCA reboot MAC Ethernet MAC address S N Serial number of RCA Port Port number if a connection is active via the adminis tration access CLI is shown here Username User name see User Add command Duration Duration of current console connection Socket Telnet socket number of RCA 23 3001 3016 From Socket IP address of LAN Console with socket number in brackets IP Input and IP network statistics Output Packets Delivered Discarded Fragments TCP Network statistics In Segs Out Segs Errors Retrans UDP Network statistics In Out Errors No port BOOT Version date and time of Boot Image APP Version date and time of Application Image Share Mode Disable Auto or Query see Server Share command Information on these fields is displayed for every connect
87. mply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference Safety notes e Only transport the device in its original packaging or in other suitable packaging which will protect it against impact and jolts e Condensation may occur when the device is brought in from the cold to its site of installation Wait until the device has reached a stable temperature and is absolutely dry before putting it into operation e Heed the ambient conditions described in the Environmental condi tions on page 28 and for the RCA4plus in the Technical specifica tions of the RCA4plus on page 28 as well as the specifications of the PW250LC see PW250 450 User s Guide or the data sheet before installing the device and putting it into operation e This device features a safety tested power cable and may only be connected to a grounded socket U41618 J Z916 1 76 5 Safety notes Make sure that the socket on the device or the mains socket on the housing installation are readily accessible The ON OFF button does not isolate the device from the mains voltage completely To do this you have to remove all plugs from the mains socket In the case of system units that do not have a main switch the ON OFF button does not disconnect the monitor socket from the mains supply A monitor connected to this socket must always b
88. n Qu LL Le 65 Error situations 2222 22m nn nn 66 No response from the RCA 66 Failure to establish a connection 66 Failure in automatic access to the RCA 67 Disrupted RCA LAN Console connection 68 LAN connection disrupted 68 No output in console window nn 69 Invalid administrator password for RCA4plus 69 RCA commands 2a p aoset i a LL LL 70 Access Tige 2 4 0 Ars dd en do ds 71 List of commands a aoa a LL 72 Help command LL LL 72 Port commands 2 2 22 En nn 72 Server commands Qu LL LL LL 78 Show commands aoao LL LL 84 User commands aoaaa LL LL 90 Serial Connections Qu LL Le 94 TeleserviCe e cer EL EI A Soe da 95 Installation and generation 96 Generating the software m nn 97 Selecting validated Teleservice modems 99 TeleCall dake eR ER ee E ee deia si 105 Installing Telecall on on 106 Preparations Qu LL LL 106 Software installation on the PVV250LC 106 U41618 J Z916 1 76 Contents 6 4 1 3 Software installation on the PRIMEPOVVER 106 6 4 1 4 Software installation on the RM 106 6
89. n LAN Console 5 4 2 2 Configuring the RM systems The line speed of the respective RCA ports must be set to 19 200 baud for connecting RM systems to the RCA RCA4 see Port commands on page 72 5 4 3 Configuring the LAN Console and RCA This section describes the initial setup of the LAN Console i e the definition of console accesses to PRIMEPOWER and RM servers and initial configuration of the RCA For an existing LAN Console setup it also describes the addition of further console connections configuration of an additional RCA and connection of another LAN Console to an RCA that has already been configured Furthermore it briefly deals with possible changes to the configuration of the LAN Console and RCA Only the root user can carry out the configuration steps The dialog language is English Error situations relating to the configuration are described in the section Diagnostics on page 64 This chapter does not contain the requested configuration procedures which admit the access to the console of PRIMEPOWER 250 450 systems via the XSCF see also Configuring the PRIMEPOWER 250 450 server and XSCF documentation in the appendix Related publications on page 117 It is however presupposed that the XSCF is known in the LAN i e it is accessible from the console The following sections Initial configuration of the LAN Console and RCA and Configuring the RCA are of no significance for the c
90. n active access check If the console connection is set up via rtty RCA username and password must be entered If the console connection is set up via telnet and ssh username and password depend on the configuration arguments of the console connection If mklancon was executed without option at a telnet session any RCA username with password may be entered At an ssh connection the input of a user password for the user Admin is mandatory If the console connection was set up with automatic access to the RCA4plus with option for mklancon this data is unnecessary for telnet and ssh The logon takes place with the RCA username and password specified during configuration Press the CtriJand key in the opened console window to access the command interface CLI Command Line Interface of the RCA4plus settings see Configuring the RCA on page 48 By now entering the command port history the input buffer can be exported A hardware break break can be sent to a PRIMEPOWER MR system via the command port break from the CLI For this the abort sequence on the target system must be set to enable This corresponds to the default setting of the target system but can also be set with the help of the command kbd a enable or by modification of the file etc default kbd After execution of the port break command you get to the OBP of the target system on entering the CLI command resume see section below Li
91. n the automatic logging on to the RCA4plus or the XSCF can be prevented by deleting the associated password command arguments see above Syntax key_create r p lanconsole3 lanconsole4 s lt ConsoleName gt Modifying the RCA4plus configuration Changes can be made to the RCA4plus configuration using the xscon command xscon lt RCA AdministrationAccess gt RCA AdministrationAccess The administration access lt RCA SystemName gt _adm or lt RCA SystemName gt _ssh recommended under RCA access if the RCA4plus is running in ssh mode The user name Admin must be used to log on to the RCA4plus The main commands for configuring the RCA4plus are listed in the section RCA commands The RCA command HELP provides an initial overview If you are using the LAN Console on an RM system the line speed for the connected RCA port should be set to 19200 baud in the RCA setup see Port commands RCA4plus firmware updates New firmware versions for the RCA4plus are available under http service fujitsu siemens com service console RCA4plus For each firmware version additional installation information is also provided here and must be observed at any rate 56 U41618 J Z916 1 76 LAN Console Configuration The firmware is updated via an TFTP server Solaris system The update is executed via the administration access to the RCA see above using the following command see Server commands on page 78 server fl
92. o the OBP using the XSCF commands available there the availability of the commands depends on the actual version of HCP see also the XSCF documentation appendix Related publications on page 117 Furthermore for telnet as well as for ssh connections a software break can be executed per Alternate Break Character Sequence CTRL B in the running operating system The connection is cleared down using the string The RCA4plus can be administered with xscon using the configuration entry lt RCA SystemName gt _adm or in ssh mode with lt RCA SystemName gt _ssh and the RCA commands 60 U41618 J Z916 1 76 LAN Console Operating the LAN Console xscon mapping consoles Prerequisites for using xscon il xscon can be called by root only The XSCF must have been configured according to the XSCF documentation see Related publications on page 117 You can obtain an exact description of the xscon command by displaying its manual page man xscon Syntax xscon lt ConsoleNamel gt L lt ConsoleName2 gt L 1 Calling xscon without parameters causes a user interface to be displayed which shows the available PRIMEPOWER and RM servers for selection The admin istration accesses created for the configured RCA4plus and RCA4 are also displayed You make the selection via Establish Connections The logging mode option allows you to decide whether the console output is to be logged The log fil
93. oard Debug Monitor and OBP Monitor PRIMEPOWER or RM servers can also be rebooted from the LAN Console xscon call Access to the PRIMEPOWER and RM servers is provided by xscon SMAWxsco package the necessary connection is selected and established internally via ssh telnet or rtty SMAWsmon package SMAWrtty package Connection setup is supported using all RCA types RCA4plus XSCF and RCA4 RCA3 To establish the connection data is required which is defined when the LAN Console is configured Please select the machines to which a connection is to be established akkord6adm aller ems leine Logging Mode enable disable Teleservice Operating enable disable Establish connections Terminate Help Figure 14 xscon mask 58 U41618 J Z916 1 76 LAN Console Operating the LAN Console On the basis of configuration entries for the LAN Console xscon enables one or more PRIMEPOWER and RM servers to be selected that are to be represented on the LAN Console The names of the selectable systems are the console names that were specified in the mklancon script when the configuration entries were created The xscon user interface can also be chosen via the Solaris Common Desktop Environment where there is a corresponding entry in the Application Manager The connection is established in the same way as for cu 1 Connection via RCA4plus By default the connection is set up via an RCA4plus with a
94. ol DVD 96 U41618 J Z916 1 76 129 Index Control CD DVD 31 32 Cross over 27 D detach mirroring 14 dhcp 48 dhcpconfig 48 dhtadm 48 diagnostics monitor 64 dimensions 28 direct connection 27 disconnect 94 disk mirroring 11 disk partitoning 10 disruption 68 distance building 1 DNS 40 domain name service 40 E error situations trace level 64 Ethernet 21 ethernet address RCA 40 Ethernet connection 21 Ethernet port 21 exhaust air clearance 28 extended system control facility 112 G gateway address 66 H hard didsk partitioning 10 hard disk partitioning 10 high speed modem 96 l important information 5 Init 30 initializing RCA 30 input buffer 59 installer 31 installing LAN console 31 telecall 106 intel based LAN console 20 internal kernel debugger 58 IP address 66 LAN Console 40 RCA 40 IP address RCA deleting 30 K key binding 62 L LAN Console configuration 35 disrupted connection 68 intel based 20 IP address 40 remove configuration entries 46 show configuration entries 47 software 20 31 lanconsole 47 lanconsole1 47 lanconsole3 47 lanconsole4 45 47 language setting 9 15 33 line speed 37 56 hardware RCA port 38 56 RCA 19 Link LED 30 hardware address 66 log hardware break 59 logging mode 61 help command logfile 64 RCA 72 94 Logging 3 0 106 130 U41618 J Z916 1 76 Index M MAC address 66 RCA 40 Machine Administration Menu 37 man pages 12 mapping cons
95. oles 61 Midrange Servers system administration 1 mirroring 11 13 14 mixed operation PRIMEPOWER and RM systems 2 mklancon 43 65 xscon 59 mkrca 48 monitor diagnostics 64 lanconsole 45 lanconsole1 45 lanconsole3 45 lanconsole4 45 RCA3 45 RCA4 45 XSCF 45 monitors 47 Multiport Console Connection Unit 2 N network cable 27 node_adm 108 O OBP monitor 58 Online LED 30 order numbers cable 22 P packaging 11 partitioning 10 password 54 63 RCA 50 59 patches Solaris 9 PATH 33 pmadm monitors 65 pntadm 48 port break command 59 port history 59 port number 75 RCA 41 65 ports 35 power LED 30 PRIMEPOWER 1 100N 200 400 600 650 850 1 connecting to RCA 22 27 connection cable 22 Enterprise Server 10 models 800 1000 2000 10 models 800 900 1000 1500 2000 2500 2 port cable 27 PRIMEPOWER250 17 PRIMEPOWER250 450 35 37 PRIMEPOWER450 17 prom monitor 58 PW250LC 1 R RCA authentication check 50 authentication method 84 configuration 35 connect 94 connecting to PRIMEPOWER 22 console port 51 delete configuration 30 delete IP address 30 firmware update 56 help command 72 94 initializing 30 IP address 40 network cable 27 password 50 59 port number 65 rear view 19 restart 30 U41618 J Z916 1 76 131 Index RJ45 27 user name 50 RCA configuration deleting 30 RCA port line speed 56 RCA1 3 36 RCA3 19 35 configuration 54 monitor 45 system information 65 RCA4 19 35 75 autom
96. on XXXXX Done Press ENTER to continue gt Confirm this prompt with the lt ENTER gt key This completes installation of your modem Now you can continue with administration of the TELESERVICE channel gt In window 2 first choose option b Parameter for registration OLR and autom defect reporting ADR customername contact person 81234 56798 991 Mail address Sad Pa U NO e A Show state of Teleseruice Channel form and save your input by pressing lt F3 gt HELP CHOICES a PB CANCEL BCHO MENT EXIT 100 U41618 J Z916 1 76 Teleservice Selecting validated Teleservice modems Input is required for registration vvhich vvill be prompted at this point you must fill in these fields including Phone Fax gt Enter the ident number of the computer If technically feasible this will be already displayed This number is unique and identifies you for all subse quent Teleservice activities The ident number can be found on the nameplate on your system unit Company abbrev Enter a short name for the company and if there is sufficient space the location where you are based The Automatic Defect Reporting ADR no and Administrator s mail address blank are preassigned default values for the TeleCall function You will find further information on the topic of TeleCall on the Internet under http serviceportal sbs de technics technics sws
97. onfiguration of console access via the XSCF 38 U41618 J Z916 1 76 LAN Console Configuration Configuring the LAN console Create configuration entry lt mklancon Configuration entry no Delete correct rr configuration entry showlancon rmlancon yes Next yes configuration entry2 no Configuring the RCA Make the RCA addressable in the network Switch on RCA Configure RCA xscon Figure 12 Configuring the LAN console and the RCA U41618 J Z916 1 76 39 Configuration LAN Console 5 4 3 1 Initial configuration of the LAN Console and RCA If console connections via the RCA are not set up via ssh or telnet see mklancon Create LAN Console configuration entries on page 43 the RCA for security reasons has to be connected in the private LAN The initial configuration of the LAN Console and RCA takes place in two steps The first step is to define the console accesses to the PRIMEPOWER and RM servers for the LAN Console In addition the RCA is made known in the network from the LAN Console and then configured Before a LAN Console and RCA are configured for the first time certain precau tions must be taken and the required information must be made available e The network administrator must define the following in the LAN IP address of the RCA and the LAN Console The LAN Console
98. ow 3 Parameter for registration OLR and autom defect reporting ADR This number is unique and identifies you for all subsequent Teleservice activities You will find the identification number on the nameplate on your system unit Change the Automatic Defect Reporting ADR field to yes with the Choices function and enter the connection index for the Teleservice center in Paderborn or Munich in the to center field Enter your customer information in the other fields Mandatory fields All fields including Phone Fax are mandatory gt Save the Parameter for registration OLR and autom defect reporting ADR window with SAVE 2 Use the node_adm command to make the Telecall cluster aware of the PW250LC node adm A n lt SystemName PW250LC gt C telx Password for lt SystemName gt lt Password for root gt 3 Use the node adm command to add all other machines to the Telecall cluster node adm A n lt SystemName gt C telx Password for lt SystemName gt lt Password for root gt 4 Check the state of the machines in the TeleCall cluster using the command node adm LI C telx 108 U41618 J Z916 1 76 Teleservice TeleCall All machines must be in the INTEGRATED state Example kkkkkkkkkkkkkkkkk CLUSTER NAME tel x kkkkkkkkkkkkkkkkkkkkkkkkkkkkk NODE STATE SYSTEM VERSION IDENT NAME PW250LC INTEGRATED SunOS 5 7 Generic 106541 14
99. pecially for the admssh port XSCF login is made directly If no l option is specified the password of the XSCF user Admin is asked for in an ssh connection For telnet connections configured via XSCF the option need not be specified The setup of the telnet connection leads directly to the console window or the XSCF login For the setup of telnet connections via the XSCF only the existence of an XSCF user with root rights is required If a port number in the range of 3009 3016 or 3109 3116 is specified for the RCA4 plus you will be notified that a configuration entry for an RCA4 with 16 ports will be generated 44 U41618 J Z916 1 76 LAN Console Configuration If the port number admin Or admssh is entered for the RCA4 plus or the XSCF a configuration entry is created for administering the RCA4 plus XSCF see also Configuring the RCA on page 48 and documentation on the XSCF appendix Related publications To execute the command for an RCA3 a password has to be assigned for the specified RCA port The following are created when a configuration entry is generated for an RCA type for the first time the monitor lanconsole for the RCA3 the monitor lanconsolel for the RCA4 plus without specification of the kind of connection without c option the monitor lanconsole3 for ssh or telnet connections to the RCA4 plus c option s t and the monitor lanconsole4 for the XSCF U41618
100. product see PRIMEPOWER ServerView Suite 2 2 manual Teleservice 4 0 SMAWissv is already preinstalled The SMAWxsco package requires the following packages which have already been installed SUNWbnur Networking UUCP Utilities Root SUNWbnuu Networking UUCP Utilities User SUNWdhcsr BOOTP DHCP Server Services Root SUNWdhcsu BOOTP DHCP Server Services User With respect to the functionality of the components in the individual packages itis assumed that the path usr openwin bin is contained in the PATH environment variable This path must be set for root Language settings In accordance with the preinstallation of the PW250LC setting as under Preinstallation of the PW250LC on page 9 German is supported as the standard language Especially the output of the mask texts of xscon is in German see Operating the LAN Console on page 58 If additional languages have been installed and another language setting is to be used e g en GB ISO8859 1 the following adaptation has to be made to get the output of xscon in English owner root cd usr lib locale en_GB 1S08859 1 LC_MESSAGES 1n s opt SMAW SMAWxsco locale en_US xscon pwd xscon xscon does not support other languages than German and English U41618 J Z916 1 76 33 Installing software packages on the LAN Console LAN Console Starting PRIMEPOWER ServerView Suite You can start PRIMEPOWER ServerView Su
101. ration access to the RCA created using mklancon is referred to in general as lt RCA SystemName gt _adm The RCA can also be administered if necessary using telnet Syntax telnet lt RCA SystemName gt RCA SystemName The system name of the required RCA U41618 J Z916 1 76 51 Configuration LAN Console Once the connection has been set up the user name Admin must be specified for initial access the password has not been assigned at this point i e lt RETURNS gt should be pressed The password for the Admin user must then be reassigned This concludes the initial configuration of the RCA the connection to the RCA is not yet terminated however The user named under RCA access on page 50 is now created for the console connections Syntax user add lt User gt password lt Password gt access pall break User Freely assignable user name see User commands on page 90 Password Password for this user in plain text see User commands on page 90 When aconnection is being set up it is possible to branch to the Command Line Interface CLI of the RCA For example this allows a BREAK to be issued to the target system As an example the CLI access sequence is defined in a uniform way as CTRL for all ports of the RCA with the following command see Server CLI commands Syntax port all set char none server cli char The same values are predefined for all ports of the RC
102. re to be configured in the same LAN segment dhtadm A m lt RCA gt d BootSrvA lt IP LAN Console gt RCA Unique designation of the RCA in the DHCP configuration e g the system name of the RCA IP LAN Console IP address of the LAN Console Now enter the following command pntadm A lt IP RCA gt f BOOTP i O1 lt MAC RCA gt m lt RCA gt lt DHCP table gt IP RCA IP address of the RCA MAC RCA MAC address of the RCA only upper case letters permitted Together with the prefix 01 this forms a character string for the i option RCA Designation of the RCA which must be the same as that used in the dhtadm command DHCP table DHCP table in the form X X X 0 X decimal value 0 lt X lt 255 desig nates the table generated with the aforementioned pntadm command The bootp configuration is then activated by restarting the dhcp service etc init d dhcp stop etc init d dhcp start U41618 J Z916 1 76 49 Configuration LAN Console The RCA can thus be accessed from the LAN Console e g telnet Or ping when it is switched on for the first time and has executed its boot phase RCA access You will find an overview of all available RCA commands in the section RCA commands on page 70 By default an authentication check is performed for accessing the RCA4plus i e the user name and password must first be entered correctly before the RCA can be used This authentication check can be
103. rred to as configuration entries can be defined for the PRIME POWER or RM servers This can be done with the aid of the mklancon script by specifying the type of RCA RCA Type the type of connection ssh telnet rtty the system name of the RCA RCA SystemName the RCA port number to be used RCA PortNumber the console name ConsoleName The console name is the logical address of the PRIMEPOWER or RM server that is to be administered It is advisable to use the system name of the PRIMEPOWER or RM server as the console name The showlancon script checks the configuration entries that are created Configuration entries can be removed with the aid of rmlancon If parameters need to be changed for a configuration entry this entry has to be deleted and recreated with the new data Commands For each of these commands there is a description that you can look up with man command name U41618 J Z916 1 76 41 Configuration LAN Console telnet and ssh connections The RCA not the XSCF can operate either in telnet mode for console connections via telnet and rtty or in ssh mode for console connections via ssh Basically console connections can be implemented simultaneously via the RCA4plus using both telnet and ssh see RCA commands The section Activate ssh mode on page 53 describes only the configuration in which either telnet or ssh connections are possible exclusively The RCA4plus permits up
104. rs ENABLE Enables ssh session access to the RCA DISABLE Disables ssh session access to the RCA 5 9 2 4 Show commands Show Port You can use the Show Port command to display configuration and status infor mation for the RCA ports Access rights SMON or ADMIN APPLIANCEADMIN Syntax SHOW PORT lt RCA PortNumber gt ALL Parameters RCA PortNumber Port numbers 1 8 or CON CONSOLE PORT ALL Shows the information for all ports including the console port CON 84 U41618 J Z916 1 76 LAN Console RCA commands Default Own port if the CLI was activated from an existing console connection Some of information output by the Show Port command is explained below Field Content Port Port number Serial Port Settings Port settings see Port Set command TX Bytes Number of bytes transferred RX Bytes Number of bytes received Errors Number of TX RX parity framing errors User User name for active authentication check see Server Security User Add commands Level Affiliation of the user to a class of access rights when a user identification is active see User Add and User Set commands Access User access rights when a user identification is active see User Add and User Set commands Last Login System time entry for last user login or connection setup Duration Duration of current console connection indicates fields that are only shown if the co
105. s legally per mitted in your country Please enter key ohne SCL weitermachen und diese Meldung in Zukunft unterdruscken Administration verlassen ohne SCL weitermachen ws continue without SCL and do not display this message next time 2 exit administration else continue without SCL The Teleservice SCL is subject to optional contractual agreements You should contact your sales partner if you would like to use it The relevant service must first be set up so that the modem can be installed From the first menu in the first window choose option d Install Teleservice channel and in the next menu option a Install Modify service at Teleservice channel The physical properties are entered in the third window The device name of the Teleservice channel should be already displayed If you want to use a different port you have to change this setting here For the standard modem that is currently delivered enter rob 56kfm 1 If you are using a different modem note the validated Teleservice modems in the next section Enter the call number under which your modem can be reached from your local telephone network Enter the number without the area code U41618 J Z916 1 76 97 Generating the softvvare Teleservice gt If the modem is connected to a private automatic branch exchange PABX enter the exchange code outside line code that you dial to make a local or long distance call on the Tel
106. scribed above the RCA4plus can only be reached via ssh connections This applies both for the administration access see above and for all console connections via the individual ports of the RCA The only exception is the serial access via the console port If switchover to ssh mode takes place using the server ssh enable command see page 84 the RCA4plus can be reached via ssh and telnet connec tions U41618 J Z916 1 76 53 Configuration LAN Console 5 4 3 4 New RCA ports New ports on the LAN console Configuration entry for sport number RCA gt mklancon Configuration entry ne Delete correct gt configuration entry showlancon yes rmlancon Another yes configuration entry Figure 13 New RCA ports Further configuration entries for an existing LAN Console are created by means of the mklancon script as shown in the figure Configuring the LAN console and the RCA on page 39 and mklancon Create LAN Console configuration entries on page 43 If the newly created configuration entries relate to RM system connections the speed should be set to 19200 baud for the relevant port in the RCA4plus If configuration entries are to be created for the RCA3 a password has to be assigned for the specified port for each new entry in mklancon This password has to be notified to the RCA by entering it under the appropriate port number on the Ports
107. se Syntax USER SET lt username gt LPASSWORD lt password gt LACCESS L J lt access gt Parameters username User name password User password comprising 3 16 alphanumeric characters case sensitive The input of the new password is displayed on the screen For security clear your screen display after issuing this command 92 U41618 J Z916 1 76 LAN Console RCA commands access Access rights or classes for RCA command groups Several access rights can be defined vvith a single command call The individual definitions must be separated by commas ACCESS lt access gt Reassigns the user s access rights ACCESS lt access gt Extends the user s existing access rights by the specified rights ACCESS lt access gt Restricts a user s existing access rights by the specified rights The valid values are P lt n gt Authorized to set up console connections for the specified port number n P lt x y gt Authorized to set up console connections for the specified port numbers in the range x to y PALL Authorized to set up console connections for all ports USER Authorized to create and delete users as well as to change user data SCON Authorized to configure the RCA PCON Authorized to modify the port settings SMON Authorized to show RCA status information BREAK Authorized to send a BREAK signal ADMIN
108. specially in clusters of several servers single point of administration or if remote administration is required 5 1 Architecture The LAN Console architecture is based on the following components e PW250LC with Solaris e LAN Console software e One or more RCAs to which the LAN Console is connected via the LAN TCP IP or e The XSCF of one or more PRIMEPOWER 250 450 systems including the XSCF connection via LAN to the LAN Console e RCA4plus XSCF RCA4 and RCA3 may be operated in parallel on a LAN Console U41618 J Z916 1 76 17 Architecture LAN Console PRIMEPOWER RM Systems en 250 450 Systems y with XSCF V 24 Remote Communication Adapter RCA Ethernet TCP IP LAN Console Figure 1 LAN Console architecture 18 U41618 J Z916 1 76 LAN Console Remote Communication Adapter 5 2 Remote Communication Adapter A Remote Communication Adapter is needed to connect the LAN Console to the PRIMEPOWER entry level midrange or RM servers so that it can monitor and operate these systems The existing V 24 based serial console interfacing concept for the PRIMEPOWER RM has been retained The RCA current device designation RCA4plus is available as a standalone model with 8 ports One or two devices can be installed side by side in the rack in one height unit using an optional rack installation kit In principle the XSCF of aPRIMEPOWER 250 450 can be regarded as an RC
109. st be identical 5 6 1 Planned switches In this scenario the activities of a LAN Console are planned to be taken over by another LAN Console for organizational reasons i e the two underlying LAN Consoles are fully functional So that console accesses to the same PRIMEPOWER and RM servers can take place from the other LAN Console all active connections involving the current LAN Console must be terminated This can be done with the string The connections to the required PRIMEPOWER and RM servers can then be established from the new LAN Console 5 6 2 Switching because of problems In this scenario console accesses to the PRIMEPOWER and RM servers must take place from another LAN Console because of problems with the current LAN Console If it was impossible to terminate console accesses from the original LAN Console properly these connections may still be open on the RCA side The section Disrupted RCA LAN Console connection on page 68 provides infor mation on resetting such connections U41618 J Z916 1 76 63 Diagnostics LAN Console 5 7 Diagnostics This section provides information on the diagnostic options in the LAN Console product It describes logging properties of the monitors and the internal impact of creating configuration entries It goes on to describe diagnostic options and error situations involving the RCA 5 7 1 Log files When the LAN Console is configured the monitors lan
110. st of commands U41618 J Z916 1 76 59 Operating the LAN Console LAN Console A software break can still be triggered for all connections rtty telnet ssh in the executable system using anAlternate Break Character Sequence CTRL B To permit this the abort sequence on the target system must have been set to alternate beforehand This can be done using the command kbd a alternate or by modifying the etc default kbd file Connection via XSCF only PRIMEPOWER250 450 With console connections via XSCF the input of username and password is not required for telnet connections If mklancon was executed without option for ssh connections input of the password for the XSCF user Admin is mandatory during the setup of the connection If the ssh connection was set up with automatic access to the XSCF with l option for mklancon input of the password is not required Logon is executed with the XSCF username and password specified during configuration If the connection is set up via telnet a hardware break break in the operating system can be executed from the te net command interface using send brk leading it to the OBP For this the abort sequence on the target system must be set to enable see above Connection via RCA4plus There is no equivalent option for ssh connections By creating an additional connection directly to the XSCF XSCF administration access the operating system can be led t
111. t 104 U41618 J Z916 1 76 Teleservice TeleCall 6 4 TeleCall The PW250LC is the central point of Teleservice access to the networking systems that can be reached from the PW250LC It therefore makes sense to send TeleCall messages via it too and not via a local Teleservice connection for every machine The Telecall service is available with the Logging V3 0 software package on the Solaris for PRIMEPOWER or Reliant UNIX for RM server platforms TeleCall enables a specific response to internal events and allows a message to be sent automatically to the support center The TeleCall service can only be used in conjunction with the support center that is responsible for you If you are interested in using TeleCall for your PRIMEPOWER RM servers it is essential you get in touch with your contact person at Service before activating it or call your hotline telephone number 0180 5 2202 in Germany and inquire about a TeleCall connection or call up the following page on the Internet http serviceportal sbs de technics technics swserv reliant telecall telecall_en htm One of the components of Logging V3 0 is event management Event management is an instrument that defines events on the basis of error messages and the frequency with which they occur and initiates reactions according to these events An event occurs when the number of times that an error is reported within a certain period reaches the defined threshold value The ev
112. t at the end of the boot process When you have invoked the Server Reboot command you have to confirm the Reboot command in order to actually start the boot process This means you also have the possibility at this time to terminate the command Access rights SCON or APPLIANCEADMIN Syntax SERVER REBOOT Server Security This command allows you to enable and disable the authentication check performed when setting up console connections The connection type to the RCA telnet or ssh can still be selected You have to confirm the change before it becomes effective If this change is rejected the change does not apply The authentication check for administration access cannot be disabled When the connection type ssh to the RCA is activated for the first time the RCA authentication method is generated When it is activated again the existing authentication method is used by default However it is also possible to generate a new method This process can take a few minutes Access rights SCON Syntax SERVER SECURITY AUTHENTICATION lt auth_mode gt ENCRYPT lt conns gt Parameters auth_mode LOCAL The authentication check is performed for the users defined in the RCA U41618 J Z916 1 76 81 RCA commands LAN Console NONE No authentication check is performed This setting is not possible for ssh connections to the RCA Default LOCAL conns SSH Activates ssh connections to the RCA NONE Activates
113. telnet connections to the RCA If one of the parameters is specified the TCA is accessible only via the connection type selected If both parameters are specified separated by a comma both ssh and telnet connections to the RCA are possible Default NONE Server Set You can use the Server Set command to change the RCA address parameters These changes only become effective the next time the RCA is rebooted Access rights SCON or APPLIANCEADMIN Syntax SERVER SET IP lt 7p_address gt MASK lt subnet_mask gt LGATEWAY lt gateway_ip_address gt Parameter ip_address IP address of the RCA subnet_mask Subnet mask for the network in which the RCA is available gateway_ip_address IP address of the gateway in the RCA subnet if a gateway is set up 82 U41618 J Z916 1 76 LAN Console RCA commands Server Share The Server Share command enables the configuration of multiple simultaneous connection setups to a console which is assigned to an RCA port The RCA permits up to 16 shared console connections with a maximum of 4 parallel connections per port Depending on the Server Share option selected and the users access rights APPLIANCEADMIN ADMIN user it is possible to access the assigned console via shared connections in read or write mode or to take over an active console connection To set up multiple connections to one and the same port of the RCA a corre sponding number of configuration entri
114. the section Remote Communication Adapter Because of the comparable functionality of RCA4plus and RCA4 the type designation RCA4 is also used for RCA4plus in particular for config uring console connections see Configuring the LAN Console and RCA In terms of the possible number of console connections the RCA4plus is the same as RCA4 8 If it is necessary to make a distinction between the current RCA and previous versions the current RCA is referred to as RCA4plus and the previous versions as RCA4 8 16 or RCA3 i Distinguishing between RCA and XSCF Within this manual the XSCF of the PRIMEPOWER 250 450 systems functionally is equated with an RCA that enables a console connection and a read only console connection Therefore in the following only the terminus RCA is used if no special distinction between RCA and XSCF is necessary All available RCA types including XSCF can be operated from the LAN Console in mixed mode U41618 J Z916 1 76 35 Configuration LAN Console 5 4 1 Connection between LAN Console and RCA Between LAN Console and RCA different kinds of encrypted and unencrypted connections are possible rtty Unencrypted connection type between LAN Console and RCA in the private LAN This connection also enables access to the predecessor types RCA1 3 This connection type is not possible via the XSCF ssh A secure i e encrypted connection to the RCA and therefore to the connected consol
115. tion commands should not be available under ESF 5 8 2 Failure to establish a connection The establishment of a connection between the LAN Console and the RCA is rejected if xscon was not called by the root user If a connection cannot be set up to a target system for example the target system is not responding or the console window of another system is opened the configuration entries created with mklancon in relation to RCA name and port number should be checked see mklancon Create LAN Console configu ration entries on page 43 A possible cause could also be incorrectly connected V 24 cables for example a mix up of cables between the RCA and target system when upgrading or replacing the RCA If this is the case the connections can be set up again using rmlancon and mklancon 66 U41618 J Z916 1 76 LAN Console Error situations If the RCA RCA4plus or XSCF is running in ssh mode and the RCA authenti cation method was modified see RCA commands Server Security and Server SSH or the XSCF documentation in Related publications on page 117 further ssh connections to the RCA are rejected by the ssh running on the LAN Console because of the modified RCA authentication method Further ssh console connections are only allowed after the former RCA authentication method in the file ssh known_hosts has been deleted 5 8 3 Failure in automatic access to the RCA If the automatic access to the RCA4plus fails for
116. tioning the system can be used as a LAN Console or after corresponding upgrading as an SMC on the PRIMEPOWER Enterprise Servers If you wish to partition the hard disk differently the required size of the root file system must be ascertained in accordance with the documents SCS Release Notes and SCS Installation Guide see Online Liter ature on PRIMEPOWER for the SCS version used 10 U41618 J Z916 1 76 Preinstallation and Installation Unpacking and checking the delivery unit 4 3 Unpacking and checking the delivery unit You should keep the original device packaging in case the device has to be transported gt Unpack all the parts gt Check the package contents for visible transport damage gt Check that the delivery matches the details on the delivery note If you discover transport damage or inconsistencies between the packaging unit and the delivery note inform your local sales office immediately 4 4 Install and detach mirroring A 2 way mirror can be set up for the swap and root file systems This ensures that both disks of the PW250LC are in use It is presumed that both hard disks are partitioned identically 4copies of the state database 2 per disk one 2 way mirror for the root file system one 2 way mirror for the swap file system The extension of the file etc lvm md tab below contains the configuration entries for mirroring the root and swap file systems U41618 J Z916 1 76
117. ty When the Server Flash command is called you will be asked whether a reboot should be performed for the RCA This ensures that the firmware is actually updated U41618 J Z916 1 76 79 RCA commands LAN Console Access rights SCON or APPLIANCEADMIN Syntax SERVER FLASH BOOT APP HOSTIP lt tftp_address gt IMAGE lt host_filename gt img Parameters BOOT Updates the Boot Image APP Updates the Application Image tftp_address Specifies the IP address ofthe TFTP server A Solaris system should be used as the TFTP server for example the PW250LC host_filename Specifies in connection with the ending img the name of the file on the TFTP server that contains the desired image The image being loaded must be stored on the TFTP server in the tftpboot folder Server Init This command permits initialization i e resetting of the factory set RCA defaults Access rights SCON or APPLIANCEADMIN Syntax SERVER INIT CONFIG ALL Parameter CONFIG Initialization of the RCA except for the IP address netmask and gatevvay ALL Complete initialization of the RCA including network settings 80 U41618 J Z916 1 76 LAN Console RCA commands Server Reboot This command performs a boot for the RCA Operation of the RCA is disrupted in the process and all active console connections including this one are termi nated All previous changes made that require the RCA to be restarted come into effec
118. uthorized to configure the RCA SMON Authorized to show RCA status information BREAK Authorized to send a BREAK signal ADMIN Covers the access rights PALL USER SMON PCON BREAK APPLIANC Covers the access rights PALL USER SCON E ADMIN SMON PCON BREAK Default PALL SMON User Delete The User Delete command deletes a user entry in the RCA No further connec tions can then be set up to the RCA with this user name There is no message and also no automatic logout Access rights USER or ADMIN APPLIANCEADMIN Syntax USER DEL lt username gt Parameters username User name that is to be deleted U41618 J Z916 1 76 91 RCA commands LAN Console User Logout The User Logout command can be used to terminate all existing connections to the RCA for the specified user A suitable message is output first in each associated console window If no connection is set up for the user to the RCA an error message is issued Access rights USER or ADMIN APPLIANCEADMIN Syntax USER LOGOUT lt username gt Parameters username Name of user to be logged out Users of the class ADMIN cannot log out users of the class APPLIANCEADMIN User Set You can use the User Set command to change the access rights of a user relating to the RCA commands or to change the user password Access rights None to change your own password USER or ADMIN APPLIANCEADMIN to change anything el