1.   adjust the parameters  When finished  press the  Enter kev to save    Press the  send  button to send the setting parameters of remote to the  controller  three lights flash  indicating that the controller programming is  successfully set     Press the  receive  button to confirm whether the program is set correctly     3 3 The working mode of the Load   1 Pure light control mode  When there is no sunlight  the light intensitv drops to  the start point  the controller confirmation the start signal  10 minutes after  the  controllers turn on the load and the load began to work    When there is sunshine  the start point of the light intensitv rises above  10  minutes after   the controller output signal to recognition shut off the output    thus the load will stop working    2  Testing Mode  for svstem debugging using   same pattern with the pure light  control  only cancel the judgment optical signal control output 10 minute delay   retaining all other functions  Close the load side when there is light signal    connected the load side when there no light signal   Which is much easier to  check the correctness of the system while installation and commissioning    3 Manual mode  manually open and close the output load terminals  press the     controller key  and the load terminals performing    interval Period             First Period   Second Period Third Period    sun rise        sun down    Delay 1 minute adjustable  OFF  Diagram    4  Automatic mode  When there is no sunl
2.  4 PV Cable Connection   Connect the solar panel to the controller terminals be careful of Positive and  Negative when the sun is available in the daytime the PV indicator will be  green color otherwise NOT  then you need to check the connection is correctly    or NOT     2 5 Load Cable Connection  After connected with battery and PV then connected the Load cable also be    careful of Positive and Negative if not connect correctly it is easily to burn down    the electrical appliances     2 6 Real picture of PCB Board       3 0 Work Mode Setting    The controller is programmed by infrared remote control  RC DER     Switch    Ente    Return       3 1 Key Description   Power ON OFF  Turn on and off the Remote Control  will turn off  automatically after a period of time no operation     Controller Switch  Controller manual mode  switch controller load on and off   When overload or short circuit  troubleshooting first  then press the  controller  switch   controller will return to normal state    Enter key  go to the next menu level  save with exit    Return key  to return to the previous menu without saving exit    Send key  put the written program to the controller   Only valid in the root  directory    Receive key  The parameters in the controller were readout and displayed  on the LCD screen          k  y  page up       Ma  evdown    3 2 Operating procedures brief introduction    4    Set controller models  select the desired parameter setting model    Depending on the svstem
3. 0 15V   Over voltage protection 17V  x2 24V        Working temperature    Industry grade   35  55      C       Boost charge voltage     default 14 6V  x2 24V   Only discharge condition occur         Direct charge voltage  Float charge voltage     default 14 4V  x2 24V    default 13 6V  x2 24V              charge return voltage 13 2v   x2 24V   Temperature  5mv   Lower voltage 12 0V  x2 24V        Over discharge voltage     default 11 1V  real time modified voltage by the discharge  rat  no load voltage         Over return    voltage    discharge    12 6V x2 24v          Charging mode        MPPT  Maximum Power Point Tracking          6 0 Problem and Trouble Shooting       Problem    Trouble shooting       Sunlight on solar panel  but PV charge Indicator  is not on     Check solar panel output and cable connections  are correct and connected steady       The PV charge LED  Indicator flashes fast     System over voltage protection is working   Open circuit in the battery    Check battery cable connections   Charging circuit damaged        Load LED indicator is on  but no output     Load state LED ison  and flashing fast  No  output     Load open circuit  Check cables and connections  and any other load switches     Check output for short circuit or over load  Remove  the load and switch output ON  Controller will  resume after 30 seconds        Load state LED ison  and flashing slowly  No  output     Overload has occurred  Remove sufficient load and  switch output On  Controlle
4. SDT Series   SDT SF1024 SDT SF1524     Solar Charge Controller    USER MANUAL       Beijing Remote Power Renewable Energy Technology Company  Add 3 F Huayuan Road  Haidian District  Beijing  China    www remotepowersolar com    Contents       1 0 PE Atires sities era eee l    2 0 Installation  amp  Operation           sse 2    2 1 Controller Size   2 2 Cable Information   2 3 Batterv Cable Connection  2 4 PV Cable Connection   2 5 Load Cable Connection  2 6 Real Picture of PCB Board    3 0 Work Mode Setting          Le nennennnen ne nnen 4    3 1 Mode Setup  3 2 Time Setting Table    4 0 LED Indicator    nnnnnnnnnnnennenmenzn nn    4 1 PV Indicator  4 2 Batterv Indicator  4 3 Load Indicator    5 0 SPOCHICAUOM ii ei enza savayneacxocsaneeeseeaens    6 0 Problem and Trouble Shooting           en  9    1 0 Features    Control  Micro Controller Unit utilizing dedicated software and SCM for  precise control    Charging mode  Maximum Power Point Tracking charging allows for high  efficiency boost  recovery and float charging  Temperature compensation  ensures that these parameters are adjusted for maximum battery condition  and hence  prolonged battery life    Circuit Protection  protection against overload  short circuit and reverse  connection  Built in Transient Voltage Suppression protects against lightning   Reverse current leakage through PV panel is blocked  Batteries are prevented    from over charging or discharging     Full waterproof design  the protection grade IP67 Ens
5. ight  the light intensitv drops start  point  the controller light control 10 minutes delav start the load  then  the load  start to work  When the load work to the set time load will be off automaticallv   the model has dual time function at this time  the first period after dark   the  load start to work till to the set time  Continue for some time   when the  controller comes into the second period   the load will work till reaches the    second set time period  or the light off when the batterv voltage is high load   5                                   Setting  Chose the controller mode SDT SF  SDTL SF  Parameter Setting  Name Default Adjustable Step   Unit Note  parameter Range  First period 9 00 00 09 00 00 10 h  Second period 0 00 00 09 00 00 10 h  Manual Auto light  Working moge control Test  Optical delay 10 1 60 1 min  Light control 5 3 5 10 04 V  voltage    Gel lead  Battery type Lead acid s  i  fe  iet  i                        You can set any voltage point below when you choose battery type    custom                                     Over voltage 17 15 18 1 y  protection   Pverdischarge 11 1 10 5 13 01   v  voltage point   Over discharge   return voltage 12 6 11 14 0 1 V  point   Piper charging 13 6 13 15 01   Vv  voltage   Boost cnarginig 14 6 13 15 01 l V  voltage          4 0 Displav and LED Indicator          4 1 PV Indicator    ae Sending port  Receiving Port  Load indicator  yellow   On   Load On    ee                                  Red  Over discharge 
6. protection    Infrared data transmission  Infrared data receiver     Off   Load Off   Slow flash Overload  Flash  Short    Battery indicator  yellow orange green     Orange  battery under voltage  Green  battery voltage is normal    e Slow flash   reaches the charge limit voltage    Batterv indicator light  green   Bright   light battery voltage  Dark   the battery voltage is low light             Color Indication Working State  Green On Solid PV is charging Battery  Green Flash Fast Battery Over Voltage refer to Trouble shooting        4 2 Battery Indicator                Color Indication Working State  Green On Solid Battery is Normal  Green Flash Battery is full  Yellow On Solid Battery is under voltage  Red On Solid Battery is over discharge and turn off Load       4 3 Load Indicator                   Color Indication Working State  Yellow On Solid Load is ON  Red Flash slow Over Load          5 0 Specification                         Model SDT1024SF SDT1524SF  Rated charging current 10A 15A   Rated load current 10A 15A   Svstem voltage 24V 12V automaticallv    Max input voltage of PV   100V   Max input power of PV 130W 12V 260W 24V   Energy conversion   MAX 98    efficiency       Overload Short current    1 25 rated load current 60sec  1 5 rated loads current 5sec   over load protection action  23 Rated load current short          protection circuit protection action   No load current  lt 30 mA   Charging circuit voltage    lt 0 26V   drop   Load circuit voltage drop    
7. r will resume in 30  seconds           System state LED  flashing RED with No  output        Battery is over discharged and load disconnected   Theload will be reconnected when battery  charged again        POWER    reeMOTe    THH       www remotepowersolar com       Email support repowersolar com    Add 3 F  HuaYuan Road HaiDian District Beijing  10088 China    Tel  86 10 82670382    Fax  86 10 82257376       
8. ure that the products  can be used under rugged environment     LED indication  Indicating LED   s  monitor battery charging levels as well as  battery state  LED monitoring of load conditions such as over load and short  circuit as well as load on off  are also provided    Infrared Remote Control  Use the infrared programmer can change many  work parameters like the load light control  time control and the charging  voltage etc  it make the product has more extensive applicability   Battery  can apply to lead acid battery and gel battery  and it also can be set  by user through the custom option   High efficiency  MPPT charge function can accurately track the maximum    power point more than 99      2 0 Installation  amp  Operation    Attention  Connect battery first be care of Positive    and Negative       2 1 Controller Size    Mount the controller in a suitable place   Controller Dimensions  109x114x23 2mm    Installation size   54x105mm    109 23 2                                                    2 2 Cable Information  There are 6 cables 3 red and 3 black  on the controller  3 red cables are    Positive PV Battery and Load   and the black cables are Negative     2 3 Batterv Cable Connection  Connect batterv Positive and Negative to the controller first to power on  the controller Make sure correct polaritv of terminals    The controller has protection of reverse polaritv so even not connect    correctiv for positive and negative the controller will not be burned     2
    