Home

Multisensor Triple

image

Contents

1. PRODUCT WARRANTY PERIOD TABLE PRODUCT TYPE Multi sensor Triple PRODUCT WARRANTY One 1 PERIOD PS yea IMPORTANT The content of Product Type listed above is subject to change please refer to the www zipato com for latest update PERFORMANCE OF THE LIMITED PRODUCT WARRANTY If a product defect occurs ZIPATO s sole obligation shall be to repair or replace any defective Zipato Hardware Product free of charge provided it is returned to an Authorized ZIPATO Service Centre during the Limited Warranty Period Such repair or replacement will be rendered by ZIPATO at an Authorized ZIPATO Service Centre All component parts or hardware products that are replaced under this Limited Product Warranty become the property of ZIPATO The replacement part or product takes on the remaining Limited Warranty Period of the replaced part or product The replacement product need not be new or of an identical make model or part ZIPATO may in its discretion replace the defective product or any part thereof with any reconditioned equivalent or superior product in all material respects to the defective product WARRANTOR Tri plus grupa d o o Banjavciceva 11 10 000 Zagreb CROATIA TEL 385 0 1 4004 404 FAX 385 0 1 4004 405 DECLARATION OF CONFORMITY The Manufacturer Tri plus grupa d o o hereby declares that the product Zipabox Smart home controller 1 CE In accordance with the following Directive s 2006 95 EC The L
2. EUROPEAN UNION EU 868 42 MHz UNITED STATES US 908 42MHz RUSSIA RU 869 02MHz ISRAEL IS 916 02MHz AUSTRALIA AU 921 42MHz INDIA IN 865 20MHz LIMITED PRODUCT WARRANTY GENERAL TERMS Nothing in this Limited Product Warranty affects your statutory rights as a consumer The Limited Product Warranty set forth below is given by Tri plus grupa d o o Europe herein referred to as ZIPATO This Limited Product Warranty is only effective upon presentation of the proof of purchase Upon further request by ZIPATO this warranty card has to be presented too EXCEPT AS EXPRESSLY SET FORTH IN THIS LIMITED WARRANTY ZIPATO MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ZIPATO EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD TO THE EXTENT ALLOWED BY LOCAL LAW THE REMEDIES IN THIS WARRANTY STATEMENT ARE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES AGAINST ZIPATO THEY DO NOT HOWEVER AFFECT OR RESTRICT THE RIGHTS YOU HAVE AGAINST THE BUSINESS YOU BOUGHT A ZIPATO PRODUCT FROM IN NO EVENT WILL ZIPATO BE LIABLE FOR LOSS OF DATA OR FOR INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL INCLUDING LOST PROFIT OR DATA OR OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE HOWEVER NOTHING IN THIS AGREEMENT LIMIT
3. zipato everything under control MULTI SENSOR TRIPLE QUICK INSTALLATION GUIDE v1 TRADEMARKS Zipato and the Zipato logo are registered Trademarks All other product names mentioned herein may be trademarks or registered trademarks of their respective companies NOTICE Although Zipato has attempted to ensure the accuracy of the content of this manual it is possible that this document may contain technical inaccuracies typographical or other errors Zipato assumes no liability for any error in this publication and for damages whether direct indirect incidental and consequential or otherwise that may result from such error including but not limited to loss of data or profits Zipato provides this publication as is without warranty of any kind either express or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose The published information in the manual is subject to change without notice Zipato reserves the right to make changes in the product design layout and driver revisions without notification to its users This version of the Installation guide supersedes all previous versions ELECTROMAGNETIC COMPATIBILITY In proper state and when operated properly the product complies with all the requirements in respect of interference radiation according to EN 301 489 17 EN 301 489 1 and EN 300 328 The connections conducting HF signals m
4. bracket attached it is recommended to place the Multi Sensor Triple in the middle of the wall see Good sensor positioning 1 8 meter Q Good sensor positioning Bad sensor positioning poor area coverage make your home smart SUPPORTING COMMAND CLASSES BASIC TYPE BASIC_TYPE_ROUTING_SLAVE GENERIC TYPE GENERIC_TYPE_SENSOR_BINARY SPECIFIC TYPE SPECIFIC_TYPE_NOT_USED LISTENING FALSE Z Wave Lib 4 51 lowe CLASS 0x30 COMMAND_CLASS_SENSOR_BINARY CLASS 0x31 COMMAND_CLASS_SENSOR_MULTILEVEL CLASS 0x60 COMMAND_CLASS_MULTI_CHANNEL_V2 CLASS 0x70 COMMAND_CLASS_CONFIGURATION CLASS 0x71 COMMAND_CLASS_ALARM CLASS 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC CLASS 0x80 COMMAND_CLASS_BATTERY CLASS 0x84 COMMAND_CLASS_WAKE_UP CLASS 0x85 COMMAND_CLASS_ASSOCIATION CLASS 0x86 COMMAND_CLASS_VERSION CLASS 0xEF COMMAND_CLASS_MARK CLASS 0x20 COMMAND_CLASS_BASIC NOT LISTENING ROUTING SLAVE This Z Wave product will be used as routing slave Slave nodes are nodes in a Z Wave network that receive commands and perform actions based on the command This device will always be in sleep mode because it works on batteries In sleep mode the device is not active listening the device will wake up according to the wakeup command class INCLUDE INITIATOR The include initiator is used when Primary and Inclusion Controllers include nodes into the network When both the include initiator h
5. FF can be any value except for 0x55 or OxAA When the value of configuration value is requested 2 possible values can be returned CONFIGURATION_REPORT PARAMETER 0x01 VALUE 0X55 Device doesn t have all his configuration settings anymore Even when a configuration parameter is changed back to the default value VALUE OXAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed ALWAYS AWAKE MODE The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET PARAMETER 0x05 SIZE 0x01 can t be different from 1 VALUE 0x03 mode 3 The always awake mode can be deactivated by CONFIGURATION_SET PARAMETER 0x05 SIZE 0x01 can t be different from 1 VALUE Any value except 3 Asecond option to deactivate mode 3 is 1 Remove batteries 2 Wait ca 10 seconds 3 Replace batteries NOTE in always awake mode the batteries will be drain very fast we do not recommend to use this mode TROUBLESHOOTING FREQUENTLY ASKED QUESTIONS Q I can t have my Multi Sensor Triple included into my Z Wave network what am doing wrong A 1 Is the controller ready to include any device into the Z Wave network If the controller is not in Include or exclude mode the Multi Sensor Triple can not be included or excluded 1 The Multi Sensor Triple is already i
6. S ZIPATO S LIABILITY TO YOU I IN THE EVENT OF DEATH OR PERSONAL INJURY TO THE EXTENT RESULTING FROM ZIPATO S NEGLIGENCE OR II TO THE EXTENT RESULTING FROM ANY FRAUDULENT MISREPRESENTATION ON THE PART OF ZIPATO OR IlI TO THE EXTENT ARISING UNDER PART 1 OF THE CONSUMER PROTECTION ACT 1987 OF THE UNITED KINGDOM SOME STATES OR COUNTRIES DO NOT ALLOW 1 A DISCLAIMER OF IMPLIED WARRANTIES 2 A LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR 3 LIMITATION OF INCIDENTAL OR make your home smart CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS IN SUCH STATES OR COUNTRIES SOME EXCLUSIONS OR LIMITATIONS OF THIS LIMITED WARRANTY MAY NOT APPLY TO YOU THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT MAY VARY FROM STATE TO STATE OR FROM COUNTRY TO COUNTRY YOU ARE ADVISED TO CONSULT APPLICABLE STATE OR COUNTRY LAWS FOR A FULL DETERMINATION OF YOUR RIGHTS This Limited Product Warranty applies to ZIPATO branded hardware products collectively referred to as ZIPATO Hardware Products sold by ZIPATO Europe its European subsidiaries affiliates authorized resellers or country distributors collectively referred to as ZIPATO Resellers with this Limited Product Warranty The term ZIPATO Hardware Product is limited to the hardware components and all its internal components including firmware The term ZIPATO Hardware Product DOES NOT include any software
7. applications or programs GEOGRAPHICAL SCOPE OF THE LIMITED PRODUCT WARRANTY This Limited Product Warranty is applicable to Hardware Products sold by Zipato Resellers in all countries listed at the beginning of this document under the heading Countries in which this ZIPATO Limited Product Warranty applies The Limited Product Warranty will be honored in any country where ZIPATO or its authorized service providers offer warranty service subject to the terms and conditions set forth in this Limited Product Warranty However warranty service availability and response times may vary from country to country and may also be subject to registration requirements LIMITATION OF PRODUCT WARRANTY ZIPATO warrants that the products described below under normal use are free from material defects in materials and workmanship during the Limited Product Warranty Period set forth below Limited Product Warranty Period if the product is used and serviced in accordance with the user manual and other documentation provided to the purchaser at the time of purchase or as amended from time to time ZIPATO does not warrant that the products will operate uninterrupted or error free or that all deficiencies errors defects or non conformities will be corrected This warranty shall not apply to problems resulting from a unauthorized alterations or attachments b negligence abuse or misuse including failure to operate the product in accorda
8. ave been activated simultaneously the new node will be included to the network if the node was not included previously EXCLUDE INITIATOR The exclude initiator is used by Primary Controllers to exclude nodes from the network When the exclude initiator and a slave initiator are activated simultaneously it will result in the slave being excluded from the network and reset to Node ID zero Even if the slave was not part of the network it will still be reset by this action Z WAVE COMPATIBILITY Because this is a Z Wave device it means it can co operate with other Z Wave devices of other manufacturers It can co exist in a Z Wave network existing with product from other manufacturers HOPS amp RETRIES The Z Wave range has a range of up to 30 meters in line of sight This signal is not limited to the 30 meter range due to routing the Z Wave message to other nodes in the network This way the range of the Z Wave network can be expanded to 150 meters indoors limit of 4 hops CLASS 0X20 COMMAND_CLASS_BASIC When a movement is detected a basic set frame with value 255 is sent to the associated nodes If the configured time is done with no movement is detected a basic set frame with value 0 is sent to the associated nodes This is the controlling role of the basic command class The supporting role of the basic command class is mapped to the sensor binary command class CLASS 0X30 COMMAND_CLASS_SENSOR_ BINARY The Sensor Bi
9. eported after a get but will be handled in SW as mode 2 PARAM2 3 not used 5 The temperature offset DESCRIPTION A offset for the temperature DEFAULT 0x00 SIZE 2 bytes PARAM1 2 A signed integer to determine the offset off the temperature PARAM3 4 not used if a size is other then given size the frame is ignored totally so configuration values are not changed CLASS 0X31 COMMAND_CLASS_SENSOR_ MULTILEVEL Sensor_multilevel_get The Sensor Multilevel Command Class is used to get a report from the Multi Sensor Triple The returned value is the measured temperatue inside the housing with 2 decimals CLASS 0X60 COMMAND_CLASS_MULTI_ CHANNEL_V2 Request temperature CHANNEL 1 NOTE The returned value is the measured temperature offset inside the housing with 2 decimals Request light lux CHANNEL 2 NOTE The returned value is the measured LDR resistance in CLASS 0X85 COMMAND_CLASS_ASSOCIATION The Association Command Class is used to associate other devices with the Multi Sensor Triple The devices that are associated can be controlled on application level The Multi Sensor Triple can be associated into a grouping If so the Multi Sensor Triple can cont rol another Z Wave device Number of groupings 1 Maximum supported nodes per group 5 Because only one group is supported grouping identifier is ignored in all cases CLASS 0X84 COMMAND_CLASS_WAKE_UP The Wake Up Command Class is used a
10. f the Multi Sensor Triple indication mode Tamper pressed released 5 After 3 seconds startup routine begins indication mode Ready for learn mode 6 After 5 more seconds 8 seconds in total mounting is completed indication mode Mounting successful 7 the Multi Sensor Triple has to start up for 10 seconds 8 After 10 seconds the Multi Sensor Triple is ready for detection INCLUDE OR EXCLUDE IN Z WAVE NETWORK 1 Make sure your Z Wave controller is in the right operation mode include or exclude 2 When the Multi Sensor Triple is mounted remove it from the back cover as explained in step one of the Mounting instructions 3 Press and hold the tamper for 4 seconds indication mode Ready for learn mode Now release the tamper switch to start the inclusion or exclusion process indication mode Learn in progress 4 The product will start NWI automatically after unsuccessful normal inclusion INDICATION MODES The indicator light gives various statuses of the device as follows 1 Ready for learn mode indicator light blinks every second 2 Learn in progress add indicator light 2 times every second 3 Learn in progress remove indicator light 3 times every second 4 Learn mode success indicator light is on for one second 5 6 7 Learn mode failed indicator light blinks 8 times rapidly Tamper pressed released indicator light blinks 3 times rapidly Mounting successful indicator light is o
11. illage radio lec trique subi m me si le brouillage est susceptible d en comprom ettre le fonctionnement NOTE Changes or modifications not expressly approved by Zipato for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DISPOSING AND RECYCLING YOUR PRODUCT A This symbol on the product or packaging means that according to local laws and regulations this product sh
12. n for 1 second TECHNICAL MANUAL CAUTION This device is using a radio signal that passes through walls windows and doors The range is strongly influenced by local conditions such as large metal objects house wiring concrete furniture refrigerators microwaves and similar items On average the indoor range is approximately 30 meters www zipato com Do not expose this product to excessive heat or moisture Prevent long term exposure to direct sunlight Do not attempt to repair this product If the product is damaged or if you are in doubt about the proper operation take the product back to the place of purchase Do not clean the product with any liquid TECHNICAL DETAILS NORMAL OPERATING VOLTAGE 2x AA 1 5V batteries From 2 3 to 4 0V do not use rechargeable batteries Up to 30m in line of sight 2 5 C from 55 C to 130 C MOTION SENSOR RANGE Max 10 meters under a 110 angle STORAGE TEMPERATURE 5 C to 65 C WIRELESS RANGE TEMPERATURE SENSOR ACCURACY STORAGE HUMIDITY 10 to 70 OPERATING TEMPERATURE 0 C to 50 C OPERATING HUMIDITY 30 to 80 DETAILED INSTRUCTION We advise the Multi Sensor Triple to be mounted between 1 8m and 2 4m from the ground flat on the wall and not facing down With an optional bracket the direction the Multi Sensor Triple is points at can be changed up down and left right The Multi Sensor Triple detects movement up to 10 meters Without
13. nary Command Class can be used to check if motion is detected value 0 means that there is no motion detected and therefore a associated node is off value 255 means that a associated node is on CLASS 0X80 COMMAND_CLASS_BATTERY This class is used to request and report battery levels for a given device www zipato com everything under control MULTI SENSOR TRIPLE QUICK INSTALLATION GUIDE v1 When battery level is lower then 20 the Multi Sensor Triple will send a battery warning value 255 after every wake up notification A battery get will report the actual value even if below 20 CLASS 0X86 COMMAND_CLASS_VERSION This Command Class is used to obtain information about the Multi Sensor Triple The Z Wave library type the Z Wave protocol version and the application version will be reported CLASS 0X72 COMMAND_CLASS_ MANUFACTURER_SPECIFIC This will report information about the manufacturer This product will contain the manufacturer ID of Wintop Manufacturer ID of Wintop is 97 the ID of this product is 80 CLASS 0X70 COMMAND_CLASS_CONFIGURATION CONFIGURE PARAMETERS 0 Not used 1 Set to default DESCRIPTION Set all config values to default values factory settings Read more in chapter configuration Reset SIZE 1 byte PARAM1 if OxFF then set to default PARAM2 3 4 not used 2 Mode timeout DESCRIPTION The time used in mode 2 to turn the sensor off This Time will start runni
14. nce with specifications or interface requirements c improper handling d failure of goods or services not obtained from ZIPATO or not subject to a then effective ZIPATO warranty or maintenance agreement e improper use or storage or f fire water acts of God or other catastrophic events This warranty shall also not apply to any particular product if any ZIPATO serial number has been removed or defaced in any way ZIPATO IS NOT RESPONSIBLE FOR DAMAGE THAT OCCURS AS A RESULT OF YOUR FAILURE TO FOLLOW THE INSTRUCTIONS FOR THE ZIPATO HARDWARE PRODUCT LIMITED PRODUCT WARRANTY PERIOD The Limited Product Warranty Period starts on the date of purchase from ZIPATO Your dated sales or delivery receipt showing the date of purchase of the product is your proof of the purchase date You may be required to provide proof of purchase as a condition of receiving warranty service You are entitled to warranty service according to the terms and conditions of this document if a repair to your ZIPATO branded hardware is required within the Limited Product Warranty Period Other than in respect of products for domestic use in particular those listed in the first and last boxes in the table below this Limited Product Warranty extends only to the original end user purchaser of this ZIPATO Hardware Product and is not transferable to anyone who obtains ownership of the ZIPATO Hardware Product from the original end user purchaser www zipato com
15. ncluded in a Z Wave network Exclude the Multi Sensor Triple and Try to include it again make your home smart Q Why doesn t the Multi Sensor Triple detect any movement A 1 The Multi Sensor Triple isn t included in a Z Wave network Include it and try it again 2 The batteries are almost empty try putting new ones in Q The temperature report of the Multi Sensor Triple is incorrect A 1 The Multi Sensor Triple is placed directly in the sun which makes the temperature in the housing of the Multi Sensor Triple hotter than elsewhere in the room 2 The calibration is not the same as your other temperature sensor it is possible to do a re calibration of the temperature sensor with Vera or other gateway Q I have configured a value but when request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during configuration If the wrong size is used the frame is ignored totally Q I have configured a new value and when request it the correct value is returned but the behavior is still the same A Some configuration parameters have limits of what they can do go to the documentation about configuration to check if the value of the configured parameter is out off limit Q When mount the Multi Sensor Triple it performs its standard mounting routine but after 8 seco
16. nds the indicator light doesn t go on for 1 second but blinks 6 times A blinking 6 times can mean 1 Multi Sensor Triple is not included 2 Multi Sensor Triple is not associated 3 Multi Sensor Triple can t reached his destination If all three options are corrected Multi Sensor Triple is will operate correctly and can be mounted again Q When I exclude the Multi Sensor Triple the configuration times ar e reset back to default A That is correct when the Multi Sensor Triple is excluded all configurations including wake up timings are reset back to default You will need to configure the device again after included into the controller By forcing the tamper switch a wake up message broadcast will be send to easily change the configuration TECHNICAL SUPPORT Having trouble installing your new product Zipato s website contains the latest user documentation and software updates for Zipato products and services www zipato com CALL SUPPORT 385 0 1 4004 404 Mon Fri 9 00am 05 00pm CET www zipato com everything under control MULTI SENSOR TRIPLE QUICK INSTALLATION GUIDE v1 MODELS AND FREQUENCIES MODELS EUROPEAN UNION EU version UNITED STATES US version RUSSIA RU version ISRAEL IS version AUSTRALIA AU version INDIA IN version wt ms3in1 eu wt ms3in1 us wt ms3in1 ru wt ms3in1 is wt ms3in1 au wt ms3in1 in FREQUENCIES
17. ng as soon as detection is seen DEFAULT VALUE 0x0384 900 sec 15 min SIZE 2 bytes integer PARAM1 the most significant byte of the integer PARAM2 the least significant byte of the integer PARAM3 4 not used 3 Switch off time DESCRIPTION The switch off time will start running as soon as mode timeout is done Motion sensor is turned on and when movement is detected again the mode timeout cfg param 1 will start running all over again When switch off time is done a basic off message is sent to the associated node DEFAULT VALUE 0x0A8C 2700 sec 45 min SIZE 2 bytes integer PARAM1 the most significant byte of the integer PARAM1 the least significant byte of the integer PARAM3 4 not used 4 Sensitivity DESCRIPTION the sensitivity of the motion circuit DEFAULT 0x50 80 SIZE 1 byte PARAM1 Sensitivity value between 0 and 127 values above 127 will be reported as the set value but will be handled in SW as 127 0 is least sensitive and 127 is most sensitive PARAM2 3 4 not used make your home smart 5 The mode DESCRIPTION The mode that is entered after detection DEFAULT 0x02 SIZE 1 byte PARAM1 mode 1 2 or 3 MODE 1 no detection possible Battery save mode MODE 2 normal operation mode send on after detection and off after given time no detection MODE 3 Z Wave chip is always on to request e g version or manufacturer id If mode is 0 or higher then 3 that value will be r
18. ould be not be disposed of in the household waste but sent for recycling Please take it to a collection point designated by your local authorities once it has reached the end of its life some will accept products for free By recycling the product and its packaging in this manner you help to conserve the environment and protect human health ZIPATO AND THE ENVIRONMENT At Zipato we understand and are committed to reducing any impact our operations and products may have on the environment To minimize this impact Zipato designs and builds its products to be as environmentally friendly as possible by using recyclable low toxic materials in both products and packaging COPYRIGHT 2012 Tri plus grupa d o o All Rights Reserved No part of this manual may be reproduced or transmitted in any form without the expressed written permission of Tri plus grupa d o 0 www zipato com
19. ow Voltage Directive 89 336 EEC The Electromagnetic Compatibility Directive and 1999 5 EC R amp TT EC Directive is in conformity with the e applicable requirements of the following documents EN 61326 EN 61000 3 3 EN 61000 4 4 EN 61000 4 11 IEC EN 55011 EN 61000 6 2 EN 61000 4 5 EN 301 489 1 3 EN 300 220 2 EN 61000 4 2 EN 61000 4 6 AS NZS IEC 60335 2 97 EN 61000 3 2 EN 61000 4 3 EN 61000 4 8 EN 60335 1 hereby declare that the equipment named above has been designed to comply with the relevant sections of the above referenced specifications The unit complies with all applicable Essential Requirements of the Directives Person responsible for this declaration Dean Janacek Certification Manager 01 09 2012 Changes or modifications not expressly approved Tri plus grupa d o o for compliance could void the user s authority to operate the equipment Ke THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES make your home smart Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brou
20. t battery operated devices This class allows the Multi Sensor Triple to wake up occasionally to notify others devices that the Multi Sensor Triple is ready to receive commands After receiving the commands the Multi Sensor Triple will go into sleep mode again The wake up interval can be set using the WAKE_UP_INTERVAL_SET command The default value is 0x1C20 7200 sec 2 hour The default node is OxFF 255 broadcast It is possible to send a wake up notification on user interaction To do this press and hold the tamper switch for 8 seconds When the wake up time is set to 0 a wake up notification is never send periodically only on user interaction CLASS 0X71 COMMAND_CLASS_ALARM This command class is used to identify the state of the tamper alarm www zipato com The device will send an unsolicited report to the controller if the status is changed the value 0x00 will indicate that the tamper is placed correctly on the wall The value OxFF will indicate a tamper alarm There is 1 alarm type 3 Tamper switch Every other alarm type that is requested will be ignored by application CONFIGURATION RESET The Multi Sensor Triple Supports a configuration reset function CONFIGURATION RESET MEANS All configuration values are defaulted Wake up interval is defaulted This function can be activated by sending a configuration set frame CONFIGURATION_SET PARAMETER 0x01 SIZE 0x01 can t be different from 1 VALUE Ox
21. ust neither be manipulated nor damaged TAKE CARE OF YOUR SAFETY Display extreme caution when using ladders or steps please follow manufacturer s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required INTRODUCTION TECHNICAL SPECS NORMAL OPERATING V J 2x AA 1 5V batteries Up to 30m in line of sight TEMPERATURE SENSOR 2 5 C ACCU from 55 Cto 130 C TION SENSOR RANG Max 10 meters under a 110 angle BASIC OPERATIONS The Multi Sensor Triple can detect movement measure light intensity and temperature The Multi Sensor Triple can trigger a security system MOUNTING 1 Use a flat screwdriver at the inlets on the sides to gently unlock the back cover 2 Use the designated holes on the back cover to screw mount the make your home smart Movement sensor Light and temperature sensor Indicator LED Tamper Switch Multi Sensor Triple For optimal use mount the Multi Sensor Triple between 1 8 m and 2 4m above ground A rotating bracket is available to adjust the direction the Multi Sensor Triple is pointing to 3 Place two AA 1 5V batteries into the device 4 Mount the Multi Sensor Triple onto the back cover and be sure to close it on all sides and that the tamper gets through the back cover o

Download Pdf Manuals

image