Home

PanelView Component Specifications

image

Contents

1. PanelView Component C200 and C300 Keypad PanelView Component C200 Function Key and C300 Touch c Cc H d d mersa Paneve coN H H D R 3 mr V IE i ih EQ EQ EQ EQ 6 JY l A EO FO CO CO FO lt Fy Yt i i bg b _ m b Table 5 Dimensions PanelView Component C200 and C300 Height Approx Width Approx Depth Overall Mounted Depth PanelView Approx Approx Cutout Height Approx Cutout Width Approx Component a b c d mm in mm in C200 and C300 Keypad 119 mm 4 69 in 139 mm 5 47 in 55 mm 2 15 in 49 mm 1 93 in 99 0 1 0 3 90 0 04 119 0 1 0 4 69 0 04 C200 Function Key 54 mm 2 13 in 64 0 1 0 2 52 0 04 99 0 1 0 3 90 0 04 80 mm 3 15 in 116 mm 4 57 in 49 mm 1 93 in C300 Touch 57 mm 2 23 in 64 0 1 0 2 52 0 04 99 0 1 0 3 90 0 04 Figure 2 PanelView Component C600 Touch Terminals PanelView Component C600 Touch PanelView Component C1000 Touch C hamm d Aen Sradio PanelView C1000 1 N Pa i
2. mi Table 6 Dimensions PanelView Component C600 and C1000 PanelView Height Approx Width Approx Bee big ee de Cutout Height Approx Cutout Width Approx ie Sn en See ey mm in C600 Touch 154 mm 6 0 in 209 mm 8 23 in 57 mm 2 25 in 49 mm 1 93 in 135 0 1 0 5 31 0 04 189 0 1 0 7 44 0 04 C1000 Touch 250 mm 9 84 in 308 mm 12 13 in 54 mm 2 13 in 49 mm 1 93 in 231 0 1 0 9 09 0 04 289 0 1 0 11 38 0 04 Rockwell Automation Publication 2711C TD001A EN P October 2010 6 PanelView Component Specifications Accessories Tables 7 10 list the accessories for the Panel View Component terminals Table 7 Secure Digital Card Cat No Description 2711C RCSD USB to SD adapter with secure digital card SD Table 8 Antiglare Overlays Cat No aon Model Functi ae a unction Key Numeric Keypad Touch 2711C RG2F C200 C300 2711C RG2K C200 C300 2711C RG6T C600 2711C RG10T C1000 1 Three overlays are shipped with each catalog number Table 9 Power Terminal Blocks Cat No Description Quantity 2711C RJ422 RS422 485 connector with resistor 10 2711 TBDC DC power terminal block 10 Table 10 Power Supply Cat No Description Quantity
3. 2711P RSACDIN DIN rail mount AC to DC power supply 85 265V AC 47 63 Hz 1 Rockwell Automation Publication 2711C TD001A EN P October 2010 Software PanelView Component Specifications 7 The PanelView Component stands apart from other HMI devices with its on terminal programming software Eliminating the need to install software on a personal computer reduces both start up and servicing time Just connect your computer to the Panel View Component through a USB cable or Ethernet then launch the software through your web browser Both Microsoft Internet Explorer and Mozilla Firefox are supported A dashboard provides a single point of entry for accessing all terminal and design operations Take advantage of these features while connected to the terminal e Launch the design environment where navigation tabs guide you through application development e View the results of your design efforts directly on the terminal without having to download the application first e Modify terminal display and communication settings view system information and enable login security e Transfer files between Panel View Component storage and a USB flash drive SD card or computer and delete files from terminal storage e Change the start up application or language the terminal uses for configuration screens and diagnostic messages For programming without a PanelView Component an emulator for Windows XP and Vista systems is also av
4. PanelView Component Quick Start publication Provides instructions on setting up a sample 2711 08001 application on a PanelView Component terminal Industrial Automation Wiring and Grounding Provides general guidelines for installing a Guidelines publication 1770 4 1 Rockwell Automation industrial system Product Certifications website Provides declarations of conformity certificates http www ab com and other certification details You can view or download publications at http rockwellautomation com literature To order paper copies of technical documentation contact your local Rockwell Automation distributor or sales representative Rockwell Automation Publication 2711C TDO01A EN P October 2010 PanelView Component Specifications 11 Notes Rockwell Automation Publication 2711C TD001A EN P October 2010 Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment Safety Guidelines for the Application Installation and Maintenance of Solid State Controls publication SGI 1 1 available from your local Rockwell Automation sales office or online at http www rockwellautomation com literature describes some important differences between solid state equipment and hard wired electromechanical devices Because of this difference and also because of the wide variety of uses for solid state equipment all persons responsible for apply
5. Browser support Firefox 3 0 In Emulator available ernet Explorer 7 in terminal accessed through web browser Preferred controller MicroLogix SLC and Micro80 0 controllers Input voltage DC 18 30V DC 24V DC nomina Power consumption DC 5 W max 0 21 A at 24V DC Rockwell Automation Publication 2711C TD001A EN P October 2010 Weight approx 0 19 g 0 40 Ib 0 30 kg 0 65 Ib 0 20 kg 0 43 Ib 0 30 kg 0 65 Ib Dimensions HxWxD approx 80 x 116 x 54 mm 119 x 139 x 55 mm 80 x 116 x 57 mm 119 x 139 x 55 mm 3 15 x4 54x2 13 in 4 69 x 5 47 x 2 15 in 3 15 x 4 54 x 2 23 in 4 69 x 5 47 x 2 15 in Cutout Dimensions HxWxD 65 x 100 mm 100 x 120 mm 65 x 100 mm 100 x 120 mm 2 56 x 3 94 in 3 94 x 4 72 in 2 56 x 3 94 in 3 94 x 4 72 in 4 PanelView Component Specifications PanelView Component C600 and C1000 Table 4 Technical Specifications PanelView Component C600 and C1000 Terminals Terminal Type C600 C600 C600 C1000 Attribute 2711C T6T 2711C T6C 2711C T6M 2711C T10C Display type Color transmissive TFT Color transmissive CSTN Monochrome transmissive Color transmissive TFT active active matrix LCD passive matrix LCD FSTN passive matrix matrix LCD Display size 5 7 in 10 4 in Display area WxH 115 x 86 mm 4 53 x 3 39 in 211 x 158 mm 8 31 x 6 22 in Resolution 320 x 240 640 x 480 40 000 hours life min not 50 000
6. hours life min not replaceable Backlight replaceable White LED backlight CCFL Operator input Analog touch Actuation rating 1 000 000 presses Real time clock Battery backup Battery life 5 year min at 25 C 77 F Programming port USB device port or Ethernet port Communication ports RS 232 DH 485 RS 232 DF1 RS485 Ethernet Multi vendor communication available for Modbus Modbus TCP Siemens MPI devices Memory Card USB flash drive Secure digital SD card Cat no 2711C RCSD USB to SD adapter with secure digital SD Software Web enabled software resident in terminal accessed through web browser Browser support Firefox 3 0 Internet Explorer 7 Emulator available Preferred controller MicroLogix SLC and Micro800 controllers Input voltage DC 8 30V DC 24V DC nominal Power consumption DC 0 W max 0 42 A at 24V DC 18 W max 0 75 A at 24V DC Weight approx 0 68 g 1 48 Ib 1 57 kg 3 41 Ib Dimensions HxWxD approx 54 x 209 x 57 mm 250 x 308 x 54 mm 6 0 x 8 23 x 2 25 in 9 84 x 12 13 x 2 13 in Cutout Dimensions HxWxD 36 x 190 mm 232 x 290 mm 5 35 x 7 48 in 9 13 x 11 42 in Rockwell Automation Publication 2711C TDO01A EN P October 2010 PanelView Component Specifications 5 Dimensions Dimensions are provided for the Panel View Component terminals Figure 1 PanelView Component C200 and C300 Terminals
7. shell to 8 pin mini DIN 2711 CBL PM10 RS 232 operating programming cable for connecting PanelView oe PEN 10 m 32 7 ft Component terminals to MicroLogix controllers 9 pin D shell to 8 pin mini DIN 2711P CBL EX04 Ethernet CAT5 crossover cable for use with PanelView Component C600 RJ45 to RJ45 4 3 m 14 ft and C1000 terminals 1761 NET AIC AIC advanced interface converter RS 232 RS 485 Runtime Communication Cables Tables 13 16 provide a summary of connections between PanelView Component terminals and controllers or interface modules for runtime communication Table 13 Runtime Communication Cables PanelView Component to SLC Controllers PanelView Component SLC 500 5 01 5 02 SLC 5 03 5 04 5 05 SLC 5 03 SLC 5 04 SLC 5 05 Protocol Comm Port CH1 RJ45 CHO 9 pin RS 232 CH1 RJ45 CH1 DH CH1 ENET DH 485 DF1 or DH 485 DH 485 DF1 RS 232 DF1 port 9 pin 1747 CP3 3 m 10 ft Use AIC module Use AIC module RS 232 DH 485 port 9 pin 1761 NET AIC 1747 CP3 3 m 10 ft 1761 NET AIC DH 485 to connect to Port 1 or 2 to connect to Port 1 or 2 RS 485 DH 485 port 5 pin 2711C CBL AB03 2711C CBL ABO3 NET 1585J M type cable or EtherNet IP EtherNet IP port Use 1 81 NET EN foddi 2711P CBL EXO4 with Ethernet cable 4 m 14 ft 1 The AIC module is recommended for isolation purposes when the termin 2 Fora direct connection between the terminal a
8. 752 erenk y stanbul Tel 90 216 5698400 www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 2711C TDO01A EN P October 2010 Copyright 2010 Rockwell Automation Inc All rights reserved Printed in the U S A
9. H 485 2711 NC13 5 m 16 ft 2711 NC14 10 m 32 ft 2711 NC13 5 m 16 ft DH 485 RS 232 DH 485 port 9 pin 2711 NC14 10 m 32 ft 1585J M type cable or EtherNet IP 1 Table 16 Runtime Communication Cables PanelView Plus to Interface Modules EtherNet IP port 2711P CBL EX04 4 m 14 ft For a direct connection between the terminal and controller use the 2711P CBL EX04 crossover cable 1761 NET AIC 1761 NET AIC Port 3 DH 485 Port 2 8 pin Mini DIN 1761 CBL PM02 2 m 6 5 ft 2711 CBL PM05 5 m 16 ft 2711 CBL PM10 10 m 12 ft PanelView Plus 1761 NET AIC Protocol Comm Port Port 1 9 pin DF1 RS 232 port 9 pin 1747 CP3 3 m 10 ft DH 485 RS 232 port 9 pin 1747 CP3 3 m 10 ft 1761 CBL PMO02 2 m 6 5 ft 2711 CBL PM05 5 m 16 ft 2711 CBL PM10 10 m 12 ft Rockwell Automation Publication 2711C TD001A EN P October 2010 10 PanelView Component Specifications Additional Resources These documents contain additional information concerning related Rockwell Automation products Table 17 Additional Resources Resource Description PanelView Component Installation Instructions Provides instructions for installing a PanelView publication 2711C IN001 Component terminal PanelView Component User Manual publication Provides information on how to configure and 2711C UM001 operate the PanelView Component terminal including troubleshooting information
10. Technical Data Allen Bradley PanelView Component Specifications Catalog Numbers 2711C F2M 2711C K2M 2711C 13M 2711C K3M 2711C T6M 2711C T6C 2711C T6T 2711C T10C PanelView Component Family Topic Page PanelView Component Family Environmental Specifications Certifications Technical Specifications Dimensions Accessories Software co NI DM OY Wy N N Cables Additional Resources 10 This component level operator interface provides a control and visualization solution for low level applications using serial or Ethernet communication This device can connect directly to the PowerFlex 4 drives Preferred controllers include the Allen Bradley Micrologix SLC and Micro800 families The integrated mounting clamps of the Panel View Component provides easier panel installation and maintenance These 2 inch to 10 inch displays have built in programming software that is accessed from a web browser over a USB or Ethernet connection This means you can design your application and adjust terminal settings while viewing the results directly on the connected terminal Secured programming access unicode language switching alarm messages and history and recipe operations are other key features Rockwell Allen Bradley Rockwell Software Automation 2 PanelView Component Specifications Environmental Specifications Certifications Table 1 Environmental Specifications P
11. ailable The emulator and browser must be on the same computer Table 11 Supported Operating Systems and Browsers Operating System Browser Platform Supported Windows Vista mere a Rarer 7 Terminal and emulator Windows XP SP2 Internet Explorer 7 Terminal and emulator Firefox 3 0 Windows 2000 SP4 Internet Explorer 7 C600 and C1000 terminal Firefox 3 0 using Ethernet 1 Using Ethernet network connection only Rockwell Automation Publication 2711C TD001A EN P October 2010 8 PanelView Component Specifications Cables The table summarizes cables used by the Panel View Component terminals Table 12 Cables and Adapters Cat No Description Connectors Length 2711C CBL UU02 USB host to USB device programming cable 2 m 6 5 ft 2711C CBL AB03 RS 485 5 pin to RJ45 operating programming cable for connecting RS 485 5 pin to RJ45 PanelView Component terminals to SLC 5 01 5 02 5 03 controllers 1747 CP3 Operating programming cable for connecting PanelView Component 9 pin D shell to 9 pin D shell 3 m 10 ft erminals to SLC and MicroLogix controllers null modem cable 1761 CBL PM02 RS 232 operating programming cable for connecting PanelView 9 pin D shell to 8 pin mini DIN 2m 6 5 ft Component terminals to MicroLogix controllers 2711 CBL PM05 RS 232 operating programming cable for connecting PanelView W tans 5 m 16 4 ft Component terminals to MicroLogix controllers 3 pin D
12. anelView Component Terminals Attribute Temperature operating 2711C F2M 2711C K2M 2711C T3M 2711C K3M 2711C T6M 2711C T6C 2711C T6T 2711C T10C 0 50 C 32 122 F Temperature storage 25 70 C 13 158 F Heat Dissipation C200 C300 16 BTU hr C600 32 BTU hr C1000 58 BTU hr Relative humidity 0 95 noncondensing Vibration 2 g at 10 500 Hz Altitude operating 2000 m 6561 ft Shock operating 15g at11ms Shock nonoperating 30 g at 11 ms Enclosure ratings NEMA UL Type 12 13 4X indoor use only IEC IP54 IP65 2711C T6M 2711C T6C Series B only NEMA UL Type 12 13 and IEC IP54 Table 2 Certifications PanelView Component Terminals Certification 2711C F2M 2711C K2M 2711C T3M 2711C K3M 2711C T6M 2711C T6C 2711C T6T 2711C T10C c UL us UL Listed Industrial Control Equipment certified for US and Canada See UL File E113724 CE European Union 89 336 EEC EMC Directive compliant with e EN 61000 6 2 Industrial Immunity e EN 61000 6 4 Industrial Emissions e EN 61131 2 Programmable Controllers C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions 1 When marked See the Product Certification link at http www ab com for Declarations of Conformity Certificates and other certification details Rockwell Automation Publication 2711C TDO01A EN P October 2010 Pa
13. ing this equipment must satisfy themselves that each intended application of this equipment is acceptable In no event will Rockwell Automation Inc be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA DU002 available at http www rockwellautomation com literature Allen Bradley PanelView Component CompactLogix ControlLogix SLC Rockwell Software PowerFlex Rockwell Automation and TechConnect are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation ate property of their respective companies Rockwell Otomasyon Ticaret A S Kar Plaza Merkezi E Blok Kat 6 34
14. nd controller use the 2711 P CBL EX04 crossover cable al and controller are not on the same power supply Rockwell Automation Publication 2711C TDO01A EN P October 2010 PanelView Component Specifications 9 Table 14 Runtime Communication Cables PanelView Component to MicroLogix Controllers Protocol DF PanelView Component Comm Port RS 232 DF1 port 9 pin MicroLogix 1400 1500LRP CH1 CH2 9 pin RS 232 DF1 or DH 485 1747 CP3 3 m 10 ft CHO 8 pin Mini DIN DF1 or DH 485 1761 CBL PMO02 2 m 6 5 ft 2711 CBL PM05 5 m 16 ft 2711 CBL PM10 10 m 12 ft 1761 CBL PMO02 2 m 6 5 ft MicroLogix 1000 1100 1200 1400 1500LSP MicroLogix 1100 1400 Ethernet DH 485 RS 232 DH 485 port 9 pin 1747 CP3 3 m 10 ft 2711 CBL PMO05 5 m 16 ft Use 1761 NET ENI module 2711 CBL PM10 10 m 12 ft 1585J M type cable or 2711P CBL EX04 4 m 14 ft 2 EtherNet IP EtherNet IP port with Ethernet cable 1 The AIC module is recommended for isolation purposes when the terminal and controller are not on same power supply 2 For a direct connection between the terminal and controller use the 2711P CBL EX04 crossover cable Table 15 Runtime Communication Cables PanelView Component to CompactLogix Controllers Protocol DF1 RS 232 DF1 port 9 pin PanelView Component Comm Port CompactLogix CHO 9 pin RS 232 DF1 or D
15. nelView Component Specifications 3 Technical Specifications Component terminals The tables in this section provide technical specifications for the PanelView PanelView Component C200 and C300 Table 3 Technical Specifications PanelView Component C200 and C300 Terminals Terminal Type Attribute Display type Display size C200 2711C F2M C200 2711C K2M Monochrome transflective STN passive matrix 2in C300 2711C T3M C300 2711C K3M Monochrome transflective FSTN passive matrix 3 in Display area WxH 49 x 14 mm 1 93 x 0 55 in 67 x 33 mm 2 64 x 1 30 in Resolution 122 x 32 128 x 64 Backlight 50 000 hours life min not replaceable 50 000 hours life min not replaceable Yellow Green LED indicator White LED indicator Operator input 4 function keys F1 F4 10 function keys F1 F10 Up down left right Enter Numeric keypad 0 9 eys Up down left right decimal Enter keys 10 function keys F1 F10 Numeric keypad 0 9 Up down left right decimal Enter keys Analog touch Real time Clock Battery No battery backup 5 year min at 25 C 77 F Programming port Communication ports USB device port RS 232 DH 485 RS 232 DF1 RS485 ulti vendor communication available for Modbus Modbus TCP Siemens MPI devices Memory Card USB flash drive Software Web enabled software residen