1. Hair reduction is a gradual and cumulative process Our clinical studies have shown that there is less hair growth by using me How long it takes to see visible results and how long the results last vary from person to person Periodic treatments are recommended to maintain these results Clinical studies have shown that when hair does grow back between each of the reatments there will be less of it What is the Intended Use for me A AJ m is intended for permanent reduction of unwanted hair Skin Tone m is intended for body and facial use on skin types skin colour you are born with 1 5 ly Ony DO NOT USE DO NOT USE race e o 5 Hair Colour me is intended for use on ALL hair colours Note For effective results epilator attachment is reguired for body treatment of naturally light blond red and white grey hair Epilator should not be used on the face Body Areas me is intended for use by women and men on body hair below the neck and by women on facial hair below the cheek line Note Facial treatment is different than body treatment Make sure to read the entire user guide before you get started HOMEDICS m What is Electro Optical Synergy elos Electro optical Synergy elos is the unique and patented technology that drives the me s ability to remove unwanted hair It combines two types of energy Intense Pulsed Light IPL and Radio Frequency RF to remove hair through selectively targeti
2. If system was stored in high humidity let it dry for an hour before usage go memyelos com e HOMEDICS Validate your warranty for m and receive product updates and special offers at www memyelos com CEOS Jan 2013 All rights reserved Syneron and m are trademarks of Syneron Beauty Ltd and may be registered in certain jurisdictions Publication 1212 REV 01
3. Inside the packaging of your m you will find the following me system with one cartridge and protective cap already installed Power Cord User Guide Cleaning Brush ca C Goggles Additional Accessories Sold separately Shaver Epilator Face adaptor Replacement elos cartridges o HOMEDICS m m includes the following components Base unit 2 3 1 go Cradle Control panel with power button elos energy setting buttons indicator for the percentage 76 of pulses in the cartridge shaver epilator activation button Applicator hand piece with cord Cartridge with glass treatment window and RF bars memyelos com o On the applicator and cartridge you will find 1 Light output window The light energy flashes out through the treatment window 2 RF skin contact bars The 2 RF bars must be in complete contact with the skin for the light pulses to flash 3 Cartridge The cartridge comes attached to the applicator and is preloaded with light pulses You will need to replace the cartridge when the Empty indicator light on The base unit is red 4 Cartridge activation button Press on this button to turn on the elos cartridge You will hear the fan turn on and the activation indicator will light up 5 Cooling inlet hot air is forced out of the cooling inlet in order to keep the hand piece cool while in use c o Protective cap Q HOMEDICS m
4. No light flashes from cartridge treatment window o HOMEDICS m What does it mean Control Panel Power cable is not connected No elds energy level was selected elos energy level was selected Cartridge activating button flashes to indicate that it needs to be pressed Ambient room temperature is too high Need to reset the system 1 RF skin contact bars not in contact with the skin in treatment area 2 Cartridge activation button is not pressed Connect power cable Select an elos level The applicator fan will start blowing indicating that the cartridge is active Press the cartridge activation button The applicator fan will start blowing indicating that the elos cartridge is active Move to a cooler area with a room temperature of less than 86 degrees Fahrenheit 30 degrees Celsius and restart the system Reset 1 Disconnect power cord 2 Wait until all lights are off up to 2 minutes 3 Reconnect the power cord and turn system on In order for the system to flash pulses make sure all 3 conditions are met RF skin contact bars in contact with skin cartridge activation button on elos level selected Applicator o wo All elds energy levels are blinking Cartridge activation button does not turn on no blue light My skin is red after treatment barely see any hair reduction I feel some pain and warmth when I apply the light flashes Is this nor
5. birth marks Protect small areas of sensitive skin such as moles birthmarks etc by using a white eyeliner For larger areas of sensitive skin use a piece of cardboard or thick paper to cover the affected area and prevent exposure to the elos treatment Protect lips and the lip margin using a white eyeliner DO NOT treat tattoos or permanent makeup DO NOT treat the scalp DO NOT treat inside the nostrils or ears as these areas are delicate Avoid treating areas that contain only vellus hair very thin fine hair also called peach fuzz as this may result in undesired hair re growth In the very unlikely event that you see pigmented changes on your face please stop the treatment and consult with your doctor DO NOT use perfumed products or makeup for up to 24 hours after a treatment as this may cause slight irritation If unusual pain occurs during treatment you should stop treatment immediately o HOMEDICS m Temporary skin redness may occur up to 24 hours after treatment If the symptoms persist more than 24 hours and or you feel significant discomfort and or encounter 2 any severe side effects discontinue treatment and consult with your doctor xi How to use Step 1 Clean your skin and remove the hair on the surface of the skin You may remove the hair on your face with tweezers wox shaver etc The treatment should be performed in a broad ambient light environment Step 2 Use a white eyeliner to conc
6. of performing a skin sensitivity test Follow the treatment instructions below After the skin test wait 30 minutes and check your skin for any reaction If the skin appears normal and there is no redness or other skin reaction then you are ready to perform a full treatment to the rest of the body area Choose the elos setting that did not result in any reaction when performing a complete treatment c Treatment Step 1 Shave or remove with an epilator any visible hair in the area you want to treat For your convenience you can use the m epilator or shaver accessories to remove hair sold separately If you do so there is no need for preparations before the treatment only make sure the hair is no longer than 0 5 cm Remove the protective cap and insert the epilator or shaver cartridge instead If you do not use the designated me system shaver or epilator shave any hairs with a razor or electric shaver Shaving hair in the treatment areas should minimize the discomfort felt from the flashes Make sure that the protective cap provided is inserted The system will not work if the protective cap or epilator shaver accessory is not in place Note In order to treat blond grey red and light brown hair it is recommended to use the epilator along with the elos cartridge for better results Step 2 Clean your skin and dry it with a towel Step 3 Turn on the me system Select the Low energy level setting The device will not work
7. spots such as dark freckles birthmarks moles or warts Tattoos or dark spots may absorb too much light energy which could cause skin swelling temporary or permanent blisters or discoloration of the skin or whitening of the skin DO NOT use around the eyes on the head ears nipples genitalia or around the anus Use in these areas could cause skin swelling blisters or temporary skin discoloration or whitening of the skin memyelos com e DO NOT use if you are under the age of 18 The effects of using me in this age group 9 are unknown DO NOT use if you have any skin condition in the treatment area including acne sores psoriasis eczema burns herpes simplex wounds or a rash These conditions can make the skin more sensitive to the light treatment and could make the treatment uncomfortable or cause skin swelling blisters or infection Wait for the affected area to heal before using If you are not sure if your skin condition has healed enough to use the device then please consult with your doctor WARNINGS DO NOT open m outer cover or touch any inner parts Do not attempt to repair your device Trying to open the system may also damage the device and will void your warranty Please contact Customer Service if you have a broken or damaged device in need of repair Failure to follow these warnings can cause electrocution or electric shock DO NOT use me where it can come into contact with liquids or become wet si
8. 3 months f you have undergone any facial surgery such as face lift facial implant within the ast three months or before complete healing please consult with your doctor f you are taking any medications that cause sensitivity to the sun or have a history of any skin disorders consult with your doctor before using me on the face or any other body area Please refer to general list of Contraindications in the beginning of this User Guide WARNINGS DO NOT use above the cheek line memyelos com o DO NOT use the epilator or shaver accessories when using me on the face DO NOT expose treated areas to the sun during the entire treatment period Wait at least 2 weeks after the final treatment before you expose treated skin to the sun or tan with artificial light Even after 2 weeks make sure that the treated skin is not red from the treatment before you expose it to the sun Be sure to carefully protect the treated skin with sunscreen at least SPF 30 throughout the hair removal period Failure to follow this warning could result in skin swelling blisters temporary or permanent skin discoloration or skin whitening c DO NOT treat the eye socket or around the eye area DO NOT use for eyebrow shaping It is important to avoid accidentally treating the eyebrows as any hair loss is likely to be permanent DO NOT treat the beard area in men This might create undesirable hair removal results DO NOT treat over moles or
9. Important safety information Important Safety Information Read Before Use Read all warnings and safety information in the user manual before using the m system Always follow basic safety precautions when using any electrical product m is not designed for everyone Please read this User Guide before using it Make sure you follow all the warnings Also don t use the device if it isn t right for you see Contraindications section below go When not to use m Contraindications DO NOT use if your skin is tanned or burned from being in the sun or from tanning beds or tanning creams self tanners This can cause temporary or even permanent whitening of the skin Wait 2 weeks until the sunburn or tan disappears before using the system DO NOT expose treated areas to the sun Wait at least 24 hours after treatment before you expose treated skin to the sun or tan with artificial light Even after 24 hours make sure that the treated skin is not red from the treatment before you expose it to the sun Be sure to carefully protect the treated skin with sunscreen throughout the hair removal period DO NOT use if you are pregnant trying to become pregnant conceiving or breast feeding me has not been tested on pregnant or breast feeding women DO NOT use if you have epilepsy or light induced seizures or migraines The energy flashes might cause severe headaches and migraines DO NOT use on tattoos dark brown or black
10. SS 4 el s professional hair removal system y User Guide Contents IntroductiOnis nar ctp ERREUR RR UD RUN RS S tue DF de SUE e RUP As 1 Whar isthelntended Use for mne iin E re e he Rate ques ers pes 2 What is Electro Optical Synergy elos 9 esses errem Rm e Rm mee 3 Package CONTENT soe ev ROSTER A dw e gutes e DUC ERSTE Cg Ss 4 Important safety inform fion ce eR Ree e EROR RU Ce RR 7 Possible side effects and skin reactions 0 eee ee eee eee eee YY og 10 HOW TOMUSSVOUN NMS Sytem es guava aid des R re Rn Panes eee RR Saheb andra e Pes oe gs 11 Treting Facial Mami ui Ga testes RAD YDW Re bud DDW ETRE DEERE ESA X ud 14 SIS CUA amnad ORCS i ssc wu ee TRECE 18 How To Replace Your Cartridge Shaver Epilator Face adaptor 19 Treivelingowitm your me systetfm ee eer RE ERE RE A A DYU Y ha 21 Trewblestiao es eaa e Ra RR RR RN E RARE CN CR NOAH 22 Gudranmtes amp SenviC amp au ois ete Uer oh pe ee Deos eed KS e RE 24 Manufacturer Inform CHIOM ooo ore i C egi tree NAA ERI CRRERENIE RETE 25 SPSGCINGOMOMS RES 27 Introduction Congratulations on purchasing your m system m is an innovative device that can be used in the comfort and privacy of your own home to treat unwanted hair The system offers you greater privacy and personal convenience than professionally delivered treatments The system is intended for use by adult men and women For more information about me visit us at
11. arately visit www hoMedics co uk to purchase The face adaptor has been designed to accommodate for smaller and more delicate treatment areas on the face When the face adaptor is attached to your applicator it delivers energy in single pulse mode at the desired energy level Skin types You can treat your facial hair only if your skin type the skin colour you were born with is 1 5 If your skin type is 6 DO NOT use the me on your face DO NOT USE 26008 o HOMEDICS m General information about facial hair removal The hair on the face differs from other body areas in its physiology Its growing cycles Q are different and its characteristics such as thickness colour and depth of follicle are different from body hair The face is more sensitive to hair removal due to sensitivity of nerves in some of its areas The skin on the face and neck is more likely to be exposed daily to the sun s UV radiation and therefore may be more sensitive than other parts of your body When you should not use m on the face f your facial skin is sunburned or tanned wait until the sunburn or tan fades prior to performing a test pulse on a hidden area i e under the chin Evaluate the area after 3 days to ensure no side effects have occurred and only then start treatment If you have undergone any professional facial treatment such as a chemical peel aser light radio frequency treatment or injected dermal fillers within the past
12. ccur either at the time of treatment or after If there is no improvement within 24 hours consult your doctor Unusual pain occurs Stop treatment and consult your doctor o HOMEDICS m How to use your me system 1 Clean the cartridge light output window with a non alcohol based wet wipe or soft tissue This is done in order to remove hairs and dust from the treatment window Connect the power cable into the me system Place the me system on a table or area near an electrical wall outlet Move any other cords away from the me system so they don t get tangled with the cords from the me base unit or applicator Make sure the applicator is placed in its cradle before turning on the me Press the power button to turn the system on Wait until the indicator next to the power button turns green Now the system is ready for use Set the desired energy level Low Medium or High The cartridge is pre loaded with pulses for your use 10076 The cartridge indicator shows the percentage of pulses remaining as you use the system When the cartridge is left with 576 only the Empty indicator starts blinking When the indicator shows empty 076 replace the cartridge see instructions on page 19 q9 memyelos com e Skin Sensitivity Test Before using the system for the first time choose a small area close to the area you intend to treat for the purpose
13. eal areas that should not be treated such as the edges of your lips vermillion boarder and facial moles Step 3 Remove the protective cap and connect the face adaptor The face adaptor will emit only single pulses with the desired energy level If you do not have a face adaptor you can treat using the standard applicator Step 4 Turn on your me device Step 5 Select the LOW elos level on the base unit The device will not work if you do not select an elos setting Step 6 Put on the provided eye goggles or sunglasses Eye protection is recommended as treating near your eyes may cause temporary discomfort Step 7 Press the cartridge activation button on the applicator upper part and apply a single test pulse on a non conspicuous hidden area of your face or neck Lift the applicator once a single pulse is emitted Look at the area to see if it appears normal If you observe any unusual skin reaction do not proceed and stop your treatment immediately Step 8 Hold the applicator and gently position it on the area you want to treat Apply a single elos pulse on the area you want to treat If you feel comfortable you may change the elos level from low to med or high Step 9 Reposition the applicator on the next area to be treated Repeat Step 8 until you have covered the entire facial area 5 to 10 times Wait at least 10 seconds before you treat over the same spot We recommend treating the face every 1 2 weeks If you feel that the ha
14. egulatory standards that the system is designed to comply with c Do Not use in wet environment Class equipment Degree of protection against electric type BF applied part WEEE Waste Electrical and Electronic Equipment CE Mark Follow operating instructions This device comply with Part 15 of the FCC Federal Communications Commission Rules CSA Mark for USA and Canada Degree of protection against ingress water ordinary This device is not suitable for use in the presence of flammable anesthetic mixture with air or with Oxygen or Nitrous Oxide o HOMEDICS m Specif cations Light spectrum 550 1200 nm Max Optical 4J cm2 RF Wave frequency 6 78 MHz Max Radiofrequency power 5 Watts Conducted RF 5J cm2 Applicable Standards Safety Standards EN 60335 1 2002 A1 2004 A2 2009 EN 60335 2 8 EN 60335 2 23 2003 EN 60335 2 27 2003 EN 60825 9 IEC 60601 1 3rd edition IEC 60601 1 2nd edition IEC 60601 1 11 EMC Standards EN 61000 6 1 2007 EN 61000 6 3 2007 Electrical Rating 100 240 VAC 50 60 Hz Dimensions and weight 20 5 x 15 x 9 cm IW xLxH 1 17 Kg Acceptable Environmental Conditions Storage and transportation Temperature 109C 559C 509F 1319F Humidity 90 at 55 C 1319F Pressure 700 1060nPa Operation Temperature 10 C 30 C 50F 86 F Relative Humidity up to 80 at 37 C 99 F Altitude up to 3900 m 13 000 ft Note The system will not operate above 30 C 86 F
15. f any skin reactions developed Only if no skin reactions developed and the skin looks normal you may use me DO NOT use m on any area where you may want your hair to grow back DO NOT use the system above 86 F 30 C If the system heats up it may not work properly and may cause injury memyelos com e Possible side effects and skin reactions c Use of me could result in possible side effects These reactions are rare and should resolve within a short time However every cosmetic treatment may involve some degree of risk Possible rare reactions are described in the table below with the recommended action The reaction Recommended action Colour or textural changes to the skin that may be permanent May occur either at the time of treatment or after If there is no improvement within 24 hours consult your doctor Redness of the skin May occur either at the time of treatment or after If there is no improvement within 24 hours consult your doctor Itching of the treated area Cool the area with cold compresses but not with ice or ice packs If the itching continues consult with your doctor Acne outbreak If there is no improvement within 24 hours consult your doctor Blistering or burning of the skin Permanent scarring or loss of skin tissue and depressions Cool the area immediately with cool cold compresses but not with ice or ice packs Contact your doctor May o
16. f you don t have a new cartridge make sure you place The protective cap in place of the used cartridge to protect the system inner parts b Please follow the regulations where you live for disposal of electric systems when recycling or disposing of your base unit hand piece or disposable cartridge WEEE Directive This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer Ba RR where the product was purchased They can take this product for c Error environmental safe recycling c 5 o HOMEDICS m Traveling with your m system The me system is designed with universal voltage That means that you can use the system all over the world You will need to use an adaptor for the plug since electric wall outlets vary by country Make sure that me system does not get wet while traveling go Do Not use it in a wet environment memyelos com o a o Troubleshooting Indicator No lights are on All elos energy level lights are blinking Cartridge activation button is blinking Error light is blinking in red cartridge buttons blink as well Error light is blinking
17. if you do not select an elos setting If there is little or no discomfort or reaction except for slight redness then raise the energy level to the Medium or High setting Step 4 If you also use the designated shaver epilator press the epilator shaver activation button on the control panel once to run the epilator mechanism at low speed If desired press it again to run the epilator at high speed The shaver cartridge operates only at Speed level 1 o HOMEDICS m Step 5 Gently remove the applicator from the base go Step 6 Press the cartridge activation button located on the upper part of the applicator The indicator light will turn white and you will hear the fan inside the applicator Step 7 Gently place the applicator on your skin so that the two RF skin contact bars are in complete contact with the skin Note The applicator will not work unless both RF skin contact bars are touching the skin Step 8 After every flash move the applicator to the next neighboring spot over the skin by gliding in one continuous slow motion Avoid overlap between adjacent pulses Note The applicator will automatically turn itself off if no pulses have been emitted for one continuous minute To turn the applicator back on press the activation button located on the upper part of the applicator DO NOT hold the applicator window still over one spot on the skin and flash multiple light pulses on the skin Doing so causes too much heat
18. ir is too noticeable you can treat every 2 days Note Always start with LOW elos level If you feel comfortable you may increase the elos level for better results memyelos com Q oO ann A WwW 10 Cleaning and storage j 2 Place the applicator in its cradle on the base unit Turn off the system by pressing the power button on the base unit Gently rinse your skin with warm water Gently apply moisturising cream to your skin Unplug the electric cable from the electrical outlet Clean the cartridge light output window with a non alcoholic based wet wipe or soft tissue If you have used the designated me epilator or shaver Remove the shaver or epilator from the applicator and place the protective cap instead Use the supplied cleaning brush to clean the accessories It is recommended to use a soft tissue or a non alcoholic wet wipes for cleaning If you have used the designated me face adaptor Remove the face adaptor from the applicator and place the protective cap instead Clean the outside surface using ONLY a dry soft cloth or a non alcoholic based wet wipe Clean the outside surface of the me system using ONLY a dry soft cloth or a non alcoholic based wet wipe Store the system in a cool and dry place AWAY from the reach of children o HOMEDICS m How To Replace Your Cartridge Shaver Epilator Face adaptor Replacing your cartridge 2 o 1 Make
19. mal Cartridge slot is empty Need to reset the system The skin may become red as a result of the treatment This redness generally clears up within 24 hours Make sure to follow the protocol suggested and to use the treatment duration time suggested You may feel warmth tingling or itching It is expected that this pain and warmth will be up to moderate Insert cartridge protective cap or cartridge Reset Disconnect power cord Wait until all lights are off up to 2 minutes Reconnect the power cord and turn on system If the redness persists more than 24 hours after a treatment stop using m and contact your doctor or Customer Support Actual results will vary from person to person depending on the body area being treated and whether the instructions were followed correctly Contact Customer Support for help If the pain is severe intense or the pain persists for more than 24 hours after a treatment stop using m and contact your doctor or Customer Support memyelos com o Guarantee amp Service HoMedics Inc guarantees this product from defect in material and workmanship for a period of 2 years from the date of purchase except as noted below 1 This HoMedics product guarantee does not cover damage caused by misuse or abuse accident the attachment of any unauthorised accessory alteration to the product or any other conditions whatsoever that are beyond the control
20. ng the hair follicle in a safe yet effective manner Invented by Dr Shimon Eckhouse elos technology was exclusively available to doctors through professional hair removal devices however it is now available to consumers directly through the me device go How does Electro Optical Synergy elos Work elos technology selectively delivers heat from IPL and RF energy to the hair follicle affecting the source of where your hair grows The hair follicle is destroyed thereby removing and reducing the amount of hair you re left with in the treated area elos technology can even be used safely and effectively on most skin types Hair Growth Cycle Every hair in our body goes through a complete growth cycle from an active to resting phase Light based treatments work best on hairs in their active phase How long each cycle lasts varies from person to person and between the different parts of the body Other factors such as genetics metabolism and age also influence the duration of each growth stage What to expect from your treatment You will need to treat the areas of unwanted hair multiple times in order to target hair in the active cycle After a hair follicle is treated it can take one to two weeks for the hair to fall out During this time it may look like hair is still growing but really the hair is being pushed out You may or may not see these hair stubs pushed out from the skin memyelos com eo Package Content
21. nk bath shower This can cause electric shock If the system is dropped into liquid unplug it immediately Do Not remove the system from the liquid until unplugged Do Not use the system again and contact Customer Service DO NOT hold the applicator window still over one spot on the skin and flash multiple light pulses on the skin Doing so causes too much heat to build up and may result in skin swelling blisters or temporary or permanent changes in the colour of your skin After each flash move the treatment window to a neighboring skin spot Wait for at least 10 seconds before returning to a previously treated skin spot DO NOT use me if any parts show signs of damage This may result in injury DO NOT cover any ventilation slots during use as they help to keep the device cool during operation Covering the ventilation slots could result in the device overheating KEEP OUT OF REACH OF CHILDREN me is a powerful device and should not be used by anyone under the age of 18 o HOMEDICS m DO NOT leave me unattended around children as the cords represent a choking hazard Children should be supervised to ensure that they do not play with the appliance q9 DO NOT use if your skin is sensitive to light This condition could make the light treatment uncomfortable or cause skin swelling blisters or infection In order to determine if you can use me perform a test on a small patch of skin Then wait 30 minutes to see i
22. ns without notice to improve performance reliability or manufacturability Information furnished by Syneron Medical Ltd and HoMedics Group Ltd is believed to be accurate and reliable However Syneron Medical Ltd and HoMedics Group Ltd make no representation with respect thereof and assumes no responsibility for its use No license is granted by its implication or otherwise under any patent or patent rights of Syneron Medical Ltd Syneron Medical Ltd has patents pending patent applications trademarks copyrights or other intellectual property rights covering the me product q9 The purchase of the m and the furnishing of this document does not give any license to these patents trademarks copyrights or other intellectual property rights except as expressly provided in any official written document from Syneron Medical Ltd Be sure to read all instructions carefully before starting treatment Copyright 2012 HoMedics Group Ltd All rights reserved For UK plug If the plug on this appliance is damaged it can be replaced with a BS 1363 plug fitted with a 3A BS 1362 fuse Only use a 3 amp fuse with this appliance Care must be taken when changing the plug If in doubt contact a qualified electrician memyelos com o Labels And Symbols The nameplate label is adhered to the bottom of your me system It displays the manufacturer s name amp address the system s part amp serial numbers electrical requirements and r
23. of HoMedics This guarantee is effective only if the product is purchased and operated in the UK EU A product that requires modification or adaptation to enable it to operate in any country other than the country for which it was designed manufactured approved and or authorised or repair of products damaged by these modifications is not covered under this guarantee HoMedics shall not be responsible for any type of incidental consequential or special damages To obtain guarantee service on your product return the product post paid to your local service centre along with your dated sales receipt as proof of purchase Please refer to HoMedics Service Centre information leaflet for details of your local service centre Upon receipt HoMedics will repair or replace as appropriate your product and return it to you post paid Guarantee is solely through HoMedics Service Centre Service of this product by anyone other than the HoMedics Service Centre voids the guarantee This guarantee does not affect your statutory rights Customer service contact HoMedics Group Ltd Somerhill Business Park Five Oak Green Road Tonbridge Kent TN11 OGP UK tel 0203 302 0623 email meservice homedics co uk 24 HOMEDICS m Manufacturer Information me is manufactured by Syneron Medical Ltd and is distributed in the UK and Ireland by HoMedics Group Ltd Syneron Medical Ltd reserves the right to make changes to its products or specificatio
24. sure that the m system is turned off and the cable is unplugged from the electrical wall outlet 2 Remove the old cartridge from the applicator by gently pulling the cartridge out 2 Dispose of the old cartridge safely according to page 20 3 Take the new cartridge out of its protective container Try to avoid touching the glass Fingerprints or oils from your skin l interfere with light passing through the glass and this will reduce the treatment success C 4 Slide the new cartridge gently into the applicator until you feel it clicks into place 5 Place the applicator on the cradle of the base unit before turning on the me system 6 Turn on the me system A new cartridge will show 10076 on the control panel Make sure that the indicator on the applicator is not blinking memyelos com Q Replacing your designated m shaver epilator or face adaptor 1 Make sure that the me system is turned off and the cable is unplugged from the electrical wall outlet S Exe Or 2 Remove the protective cap from the applicator by gently sn pulling it out 3 Take the shaver epilator or face adaptor out of its 1 protective container Slide it gently into the applicator until you feel it clicks into place c 4 Place the applicator on the cradle of the base unit before turning on the me system 5 Turn on the me system Your me is ready for use Disposal of Cartridge a I
25. to build up and may result in skin swelling blisters or temporary or permanent changes in the colour of your skin After each flash move the treatment window to a different skin spot Wait for at least 10 seconds before returning to a previously treated skin spot Step 9 Repeat Step 8 until you have covered the entire area 3 to 4 times Depending on the body part the treatment time will vary 10 min 2 min 5 min 6 min 12 min Tips When using the system on difficult to treat areas e g underarm apply the applicator in 2 directions left right and up down for full coverage You can treat all body areas during the same treatment session memyelos com o Guidelines for treatments c It is normal to still see hairs after the first few treatments For best results the treatments have to be performed once a week for the first 7 weeks Performing additional monthly maintenance treatments after the first 7 treatments will help your hair removal results last longer TOP UP TREATMENT AS REQUIRED LL mii LLL LL LUI LUI oor pg we Regt RAT Cean PPS Treating Facial Hair Removing unwanted hair from the face is very different from removing unwanted hair from other parts of the body Please be sure to read this section thoroughly before starting to remove facial hair with your m When treating facial hair it is recommended to use the face adaptor but if is also possible to treat without The face adaptor can be purchased sep