Home

KoiAir™ - Garden Ponds

image

Contents

1. GETTING TO KNOW YOUR KoiAir SYSTEM KoiAir 2 shown above KoiAir 1 KoiAir 2 for ponds up to 8 000 gallons for ponds 8 000 16 000 gallons O High Efficiency KA20 KA40 Compressor 17 Watts 115 Volts 35 Watts 115 Volts Includes control valves to Control Valves balance airflow between diffusers EasySet E Includes 25 of Includes 50 of Self Weighted Airline self weighted airline self weighted airline EI Wolahicd Diffuser 1 KoiAir Diffuser 2 KoiAir Diffusers INSTALLING YOUR KoiAir AERATION SYSTEM 7 Decide on a location for the KoiAir compressor It s important to 2 Connect the self weighted Find a location in your water garden to place KoiAir 2 ONLY elevate the compressor a few inches above ground level making airline to the outlet on the com the diffuser It s recommended to place the Adjust control valves sure the compressor is above the pond s water surface If power is not pressor as well as to the diffuser diffuser away from the deepest point leaving an to balance airflow between available at the pond s edge the compressor may be located at the power area for the fish to habitat If you have two diffus diffusers if desired It is not source and extra airline can be added up to 100 to reach your desired ers equally distribute them throughout the water necessary to have even airflow diffuser location NOTE It is recommended that the compres
2. Natural Clear Water Guaranteed 4 KoiAir Installation Instructions K EDA f gt O n zi by Airmax Pond e Always use parts that are supplied or approved by Airmax Ecosystems Inc Use of Lake other parts may result in poor performance and could create a hazardous situation e Always unplug the system from the outlet and refer servicing to a qualified electrician Wate r G rs ra e n under the following conditions 1 When the power cord is damaged or frayed Ae rat i o Nn Ki t 2 If the compressor is producing unusual noises or odors INSTALLATION INSTRUCTIONS MAINTENANCE SAFETY REGULAR MAINTENANCE Diaphragm Maintenance Your KoiAir compressor will need a rebuild kit KoiAir 1 Item 120926 KoiAir 2 Item 120927 every 12 36 months depending on Operating depth air quality and operating temperature If your compressor is operating but there is no air coming out of the diffusers you will generally find that it is time to replace your diaphragm See the top cover of compressor for instructions on replacing the diaphragm Membrane Stick Maintenance No maintenance required Replace membrane stick 510165 if visible damage or if system has poor performance Air Filter Cleaning Unscrew the cover on the back of the compressor and pull off the filter cover to expose the air filter Remove the air filter and brush away any dust particles Air filter is designed to last the lifetime of the compre
3. fied in the user manual e Never operate the system if unusual noises or odors are detected Disconnect the power cord from the outlet and call for service A DANGER e Read the operating instructions carefully e To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle o THIS UNIT IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND FAULT CIR CUIT INTERRUPTER e This unit has not been investigated for use in swimming pool areas e Disconnect unit from power source before handling e Repair and exchange of cable must be carried through by the supplier manufacturer WINTER OPERATIONS A DANGER Operating in freezing conditions on an ice covered water garden will cause open water areas even in freezing conditions Also the ice thickness around these open areas will be much thinner than the ice over the remainder of the pond Injury or fatality may re sult from falling through the ice Airmax strongly recommends that this danger of thin ice around the diffuser site be clearly posted at frequent intervals Owner as sumes all responsibility for operating KoiAir Aeration Systems during winter months If you choose to turn off your system for the winter do the following e Unplug the system and remove the diffuser s airline s and compressor e Store in a dry area protected from the elements such as a garage or basement climate control recommended KoiAir Installation Instructions 3
4. sor be covered garden but away from the deepest point Do not between diffusers nor will and not exposed directly to the elements This can be accomplished by exceed 4 in depth when placing your diffusers it have any effect on the life purchasing a faux rock cover Item 510330 If you decide to use your own Depths in excess of 4 will greatly reduce airflow expectancy of the compressor cover make sure it will keep water from coming in direct contact with the compressor and that there is plenty of ventilation to the diffuser and cause excess strain on the compressor reducing its life expectancy
5. ssor Replacement is not needed PRODUCT WARRANTY The KoiAir Aeration System comes with a 3 Year Limited Warranty 3 Year warranty on compressor 1 Year warranty on diaphragm This limited warranty is extended exclusively to the original purchaser and begins from the date of original purchase receipt Airstones airline and replacement diaphragms are wearable items and are not covered by this warranty Abuse or misuse of this product voids all warranty Any sign of water damage inside the unit voids all warranty For warranty claims product must be returned to the original place of purchase with original receipt C O NTE NTS REAT FOR LL SEASON Important Information 2 i ONS EA E a hoe E een 2 E i a Ene Able E en KoiAir Aeration System 3 Natural Clear Water Guaranteed grrr Installing Your KoiAir Aeration System 3 Airmax Ecosystems Inc GUARANTEED Maintenance Sale tye anes hana ie nee eee 4 Cc WWW airmaxeco com long ficial porta ee ee ee f aoe 866 4 AIRMAX arranty Information 000008 2 KoiAir Installation Instructions IMPORTANT INFORMATION e Never connect to an extension cord This may result in equipment failure e Do not allow anything to rest on the power cord e Do not place the unit where people may step on the power cord e Never override electrical or mechanical interlock devices e Never attempt maintenance functions that are not speci

Download Pdf Manuals

image

Related Search

Related Contents

manual de instalación y funcionamiento hidromasajes y bañeras de  KViewCenter Software User Manual 2012 / 04 / 20  RapidIO Physical Layer MegaCore Function User Guide  1 COMMUNE D`ETTERBEEK GEMEENTE ETTERBEEK Séance du  CZ205 manualENGV2.indd  3Garden Products in One!  Kensington CombBind C366E Binder  Magic Maps User Guide  Builders Edge 010140060010 Installation Guide  Montageanleitungen  