Home
Bullard® Free Air® Pumps - Finishing Systems, Inc.
Contents
1. air half or full face mask respirators or four workers wearing a continuous flow supplied air hood or helmet style respirator Will also supply cool air to one worker using Bullard s Frigitron 2000 air conditioner with certain NIOSH approved Bullard hood style respirators Supplied air respirators used with this pump must be NIOSH approved to operate at 15 psig or less The air motor requires a continuous supply of 85 cfm air volume at 95 psig for optimum performance Inlet Filter Medium efficiency keeps particles larger than 25 microns out of the air supply Inlet filter can be extended up to 300 feet from the pump using V50IN and V50EX remote extension hose kits Outlet Filter Carbofine with activated carbon Weight 90 Lbs Dimensions 12 1 8 wide x 25 long x 15 high 41 5 high with air intake installed Bullard www bullard com aSullard EDP16TE AIR FLOW 16cfm at 5 psig Supplies air to three workers wearing continous flow supplied air half or full face mask repirators or two workers wearing a continuous flow supplied air hood or helmet style respirator Supplied air respirators used with this pump must be NIOSH approved to operate at 15 psig or less Operates with a totally enclosed fan cooled motor For use in oily moist or dusty conditions Inlet Filter Medium efficiency keeps particles larger thatn 25 microns out of the air supply Inlet filter can be extended up to 300 feet from the pump
2. using V50IN and V50EX remote extension hose kits Outlet Filter Carbofine with activated carbon Weight 98 Lbs Dimensions 14 wide x 28 long x 16 high EDP16HAZ Same features as EDP16TE plus Hazardous duty motor complies with National Electric Code requirements for hazardous atmospheres Thermal overload and starter contactor to be provided by the user EDP16TE EDP30 AIR FLOW 30 cfm at 10 psig Supplies air to six workers wearing contnuous flow supplied air half or full face mask repirators or four workers wearing a continuous flow supplied air hood or helmet style respirator Will also supply cool air to two workers using Bullard s Frigitron 2000 air conditionaer with certain NIOSH approved Bullard hood style respirators Supplied air respirators used with this pump must be NIOSH approved to operate at 30 psig or less Air supply hose quick disconnect pod can be extended 300 feet from pump using V60 extension hose kits Open drop proof motor drive for use in clean dry areas Inlet Filter Medium efficiency keeps particles larger than 25 microns out of the air supply Outlet Filter Carbofine with activated carbon Weight 292 lbs Dimensions 26 wide x 38 long x 32 high EDP30 AIR FLOW 50 cfm at 10 psig Supplies air to ten workers wearing continuous flow supplied air half or full face mask respirators or seven workers wearing a continuous flow supplied air hood or helm
3. 0 climate control device 26782 Remote pod EDP50 same as above R 28151 Pressure relief valve EDP30 Parts and Accessories for all Free Air Pumps 28152 Pressure relief valve EDP50 23611 Inlet filter f S16481 Quick disconnect coupler 1 2 Industrial Interchange 17101 Outlet filter cartridge Carbofine 519681 Pressure gauge 0 15 psig 17931 Cleaning Solvent 14 oz aerosol can 519683 Pressure gauge 0 30 psig V22 Quick disconnect coupler adaptor converts pump quck disconnect v60 Pod extension hose 100 foot 1 1 4 I D three per pod maximum coupler to double 3 8 female NPT V23 Quick disconnect coupler adaptor converts pump quick disconnect Parts and Accessories for Model ADP20 coupler to single 3 8 female NPT 244852 Outlet filter jar V24 Quick disconnect coupler to double 1 2 Industrial Interchange coupler 15922 Pump service kit Includes four carbon vanes 23611 inlet filter and V50IN Remote inlet air hose kit 50 feet one per pump S17101 outlet filter cartridge V50EX Remote extension hose kit 50 feet five per pump maximum 17761 Air motor service kit Includes four carbon vanes motor bearings vane springs and seal 21052 Conversion kit Includes parts and instructions to convert ADP16 or ADP3CA pumps to ADP20 09853 Pressure gauge motor 0 20 psig 16222 Pressure gauge pump 0 30 psig EDP10 EDP16TE EDP16HAZ EDP30 EDP50 Enclosure Open Drip Proof Totally Enclosed Hazardous Duty Open Drip Proof Open Drip Proof UL App
4. Bullard Free Air Pumps a Sullar d l Features and Benefits Reliable Economical Air Sources for Airline Respirators Easy to operate and easy to maintain Bullard Free Air pumps offer a low cost way to supply clean breathable air to workers in contaminated environments They are an economical air source when compressed air is not available and an inexpensive way to add breathing capacity when a compressed air source is at its maximum utilization Economical Bullard Free Air pumps are efficient and economical They are portable can be moved quickly and easily from job site to job site and they require no expensive plumbing or installation Bullard Free Air pumps are oil less so they do not produce carbon monoxide oil vapor or oil mist Since you don t need CO monitors temperature alarms airline filters or complicated calibration equipment Free Air pumps are frequently a more cost effective alternative to compressed air Easy To Use Bullard Free Air pumps are reliable and easy to use They are available in both electric and air driven models The electric models have low power requirements simply plug in set your air pressure and go to work The air driven model is ideal for both general purpose and hazardous duty use Used with optional extension hose kits the breathable air inlet can be located up to 300 feet away from the pump ADP20 Air Driven Air Flow 30 cfm at 5 psig Supplies air to six workers wearing continuous flow supplied
5. et style respirator Supplied air respirators used with this pump must be NIOSH approved to operate at 15 psig or less Air supply hose quick disconnect pod can be extended 300 feet from pump using V60 extension hose kits Open drip proof motor drive for use in clean dry areas Inlet Filter Medium efficiency keeps particles larger than 25 microns out of the air supply Outlet Filter Carbofine with activated carbon Weight 292 lbs Dimensions 26 wide x 38 long x 32 high EDP10 AIR FLOW 10 cfm at 5 psig Supplies air to two workers wearing continuous flow supplied air half or full face mask respirators or one worker wearing a continuous flow supplied air hood or helmet style respirator Supplied air respirators used with this pump must be NIOSH approved to operate at 15 psig or less Open drip proof motor drive for use in clean dry areas Inlet Filter Medium efficiency keeps particles larger than 25 microns out of the air supply Inlet filter can be extended up to 300 feet from the pump using V50IN and V50EX remote extension hose kits Outlet Filter Carbofine with activated carbon Weight 49 lbs Dimensions 8 wide x 16 3 long x 13 5 high Bullard Free Air Pumps User Manual Respiratory Work Systems Bullard offers six convenient airline respirator systems that can be used in a wide variety of job applications from painting and abrasive blasting to pharmaceutical and chemical manufactur
6. ing All you need for effective respiratory protection comes in one simple package a combination of dependable and durable Bullard products that provide superior service over time _ SPECSYS FAMBSYS GR50SYS A WARNING The Free Air pump WILL NOT filter out respirable dust particles smaller than 25 microns DO NOT use or store near sandblasting areas where silica particles may remain suspended in the air for long periods of time Misuse may cause silicosis or other serious or fatal lung diseases The Free Air pump WILL NOT remove carbon monoxide toxic gases or other contaminants from the incoming air it transfers to the respirator wearer The Free Air pump s air intake MUST be placed in a clean breathable location at all times The breathable air drawn into the inlet filter must meet at least the requirements for Type 1 gaseous air described in the Compressed Gas Association Commodity Specifications G 7 1 Grade D or higher as specified by Federal Law 42 CFR Part 84 Subpart J 84 142 b Supplied air respirators used with Bullard Free Air pumps MUST NOT be used in any atmosphere immediately dangerous to life or health or from which the wearer cannot escape without the use of the respirator Proper motor selection and wiring in accordance with local and national electric codes is the responsibility of the user 88VXSYS cC20SYS sy Failure to observe these warnings may result in death or serious inju
7. oner for worker cooling A ISO 9001 certified Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5176 www bullard com 2011 Bullard All rights reserved Free Air is a trademark of Bullard 4048 0311
8. roved UL Approved UL Approved UL Approved UL Approved CSA Approved CSA Approved CSA Approved CSA Approved CSA Approved Class Natl Elec Code Natl Elec Code Natl Elec Code Natl Elec Code Natl Elec Code Class B Class III Class I Group D Div 1 amp 2 Class B Class B Design N Division 1 amp 2 Class II Group F Div 1 amp 2 Design L Design L Code K Class III Division 1 amp 2 H P 3 4 11 2 11 2 5 5 Phase Single Single Three Single Single Cycles 60 60 60 60 60 Volts 115 Volts 115 Volts as shipped may be 230 460 Volts 230 Volts 230 Volts rewired for 208 230 Volt 60 H operation Amps 10 2 115 V 16 0 115 V 5 0 230 V 24 0 Amps at 230 V 24 0 Amps at 230 V 8 0 208 230V 2 5 460 V Protector Overload Americas E D Bullard Company 1898 Safety Way Cynthiana KY 41031 9303 Toll free 877 BULLARD 285 5273 Tel 859 234 6616 Fax 859 234 8987 www bullard com Manual Reset Thermal Overload equipped for 115 Volt operation Internal Thermal Overload Thermal overload and starter to be provided by user if rewired to 208 230 volts Europe Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 www bullardextrem com Thermal Overload and Starter Contractor to be provided by the user Asia Pacific Internal Thermal in motor starter Internal Thermal Overload in motor starter Compatible with Bullard s Frigitron 2000 Air Conditi
9. ry aSullard Bullard Free Air Pumps User Manual Ordering Information CATALOG CATALOG NUMBER DESCRIPTION NUMBER DESCRIPTION Complete Units Parts and Accessories for Models EDP10 EDP16 TE and EDPHAZ EDP10 Electric driven air pump 15921 Service kit EDP10 Includes four carbon vanes inlet and outlet filters EDP16TE Electric driven air pump and gasket EDP16HAZ Electric driven air pump hazardous duty motor 15922 Service kit EDP16TE and EDP16HAZ includes four carbon vanes inlet EDP30 Electric driven air pump and outlet filters and gasket EDP50 Electric driven air pump 244852 Outlet filter jar ADP20 Air driven air pump 16191 Quick disconnect coupler 1 2 Industrial Interchange EDP16TE and EDP16HAZ Respiratory Work Systems 7 7 16483 Quick disconnect coupler f1 2 Industrial Interchange EDP10 FAMBSYS EDP10 with FAMB respirator and 100 of breathing air hose GR50SYS EDP10 with GR50 respirator and 100 of breathing air hose Parts and Accessories for Models EDP30 and EDP50 SPECLSYS EDP10 with SPECL35 respirator and 100 of breathing air hose 15924 Service kit Includes four carbon vanes and bearings cc2osys EDP10 with CC2OTIC respirator and 100 of breathing air hose 26781 Remote pod EDP30 Includes six quick disconnect coupler pressure 88VXSYS ADP20 with 88VX Series respirator 50 of breathing air hose and gauge pressure relief valve and outlet filter cartridges Frigitron 200