Clack WS1TC Filter Valves User Manual

image

Contents

1. Arrow will point to Regen OPERATION if a regeneration is When the system is operating ae expected Tonight one of two displays will be shown time of day or days Regen a Time Ren Time until the next regeneration Regen E pass aA Time Regen Pressing A or V button will toggle between the two choices TO SET TIME OF DAY Accessed by pressing SET for approximately n 3 seconds In the event of a prolonged Adjust hour with A or V With 60 Hz power outage time of day flashes line frequency detection on power up indicating that it needs to be reset timekeeping is 12 hour with PM indicator m i y y With 50 Hz line frequency detection on All other information will be stored power up timekeeping is 24 hour without in memory no matter how long the PM indicator Press SET to go to the next the power outage Please complete step P 8 i P Adjust minutes with A or V the steps as shown to the right To Press SET to complete and return to normal access this mode press SET operation TO SET TIME OF REGENERATION AND DAYS BETWEEN REGENERATION Wen Set Regeneration Time Hour Set tidied a the time for regeneration to start For initial set up or to make ur e Press SET to go to the next step adjustments please complete the steps as shown m y Set Regeneration Time Minutes v Access this mode by pressing SET Rega i Press SET to go to the next step and A
2. Regen Time Min Fill Regen Time zu All times in Minutes Program CI Ca C3 C4 CS Ist Backwash Regenerate 2nd Backwash Rinse Fill PO 1 99 Pl 1 99 P2 1 99 P3 1 99 P4 3 Skipped 1 99 P7 6 Skipped Skipped 4 Skipped STEP 3SS If program PO through P6 was selected enter in the minutes of fill using A or V The allowable values vary from a low of 1 to a high of 99 If program P7 P8 or P9 was selected this Mie ril PM screen will not appear Press SET button to go to Step 4SS Note For each minute of fill 0 5 gallons men RT of water is added to the solution tank With Sodium Chloride each 0 5 gallon of water will dissolve SET A V 1 5 pounds of salt WS1TC amp WS1 25 TC Manual Regen Time Min Fill PM Regen Days To Time Regen amp TATV Regen Time Min Fill ALI PM Regen I l Days To Time E Regen AIV Return to Normal Mode i or i or Regen Time Min Fill PM Regen Days To Time Regen TA Time PM Days To Regen AIV Regen Min Fill Regen Time L Uu age ct Page 7 STEP 4SS Use A or V to switch between 1 99 Days Between Regeneration Regeneration is determined by the number of days that have passed since the last regeneration scheduled 7 Day Regeneration is scheduled for specific days of the week Press SET to go to Step 5SS STEP SSS If a differential pressure switch is installed and actuated for 2 minut
3. SET Return to Normal Mode Page 9 STEP 5I7 Sunday Regeneration To regenerate on Sunday use A or V until the arrow points to Regen If the arrow does not point to Regen a regeneration will not occur on Sunday Press SET to go to STEP 6I7 STEP 617 Monday Regeneration To regenerate on Monday use A or V until the arrow points to Regen If the arrow does not point to Regen a regeneration will not occur on Monday Press SET to go to STEP 717 STEP 717 Tuesday Regeneration To regenerate on Tuesday use A or V until the arrow points to Regen If the arrow does not point to Regen a regeneration will not occur on Tuesday Press SET to go to STEP 8I7 STEP 817 Wednesday Regeneration To regenerate on Wednesday use A or V until the arrow points to Regen If the arrow does not point to Regen a regeneration will not occur on Wednesday Press SET to go to STEP 9I7 STEP 917 Thursday Regeneration To regenerate on Thursday use A or V until the arrow points to Regen If the arrow does not point to Regen a regeneration will not occur on Thursday Press SET to go to STEP 10I7 STEP 10I7 Friday Regeneration To regenerate on Friday use A or V until the arrow points to Regen If the arrow does not point to Regen a regeneration will not occur on Friday Press SET to go to STEP 11I7 STEP 1117 Saturday Regeneration To regenerate on Saturday use A or V until the arrow points to Regen If the arrow does not point to Regen a regen
4. Time Regen Power Loss Only the current time of day will need to be reset if power is lost for greater than 8 hours If power is lost while the system is regenerating the control will complete regeneration at the point of interuption once power is restored Error Message If E1 E2 E3 or E4 appears on the display contact the OEM for help This indicates that the Regen ase valve did not function properly Regen ins i e IAIV Page 12 WS1TC amp WS1 25 TC Manual Front Cover and Drive Assembly Drawing No Order No Description Quantity 1 V3175TC 01 WSITC FRONT COVER ASY 1 2 V3107 01 WS1 MOTOR ASY 1 3 V3106 01 WS1 DRIVE BRACKET amp SPRING CLIP 1 4 V3818TC WSITC PC BOARD 4 DIGIT 1 5 V3110 WS1 DRIVE REDUCING GEAR 12 X 36 3 6 V3109 WS1 DRIVE GEAR COVER 1 V3002TC WSITC DRIVE ASY d Not Shown V3186 WS1 AC ADAPTER 110V 12V 1 V3186 WS1 AC ADAPTER 110V 12V V3186EU WS1 AC ADAPTER 220 240V 12V EU Not Shown 1 V3186UK WS1 AC ADAPTER 220 240V 12V UK V3186 01 WS1 AC ADAPTER CORD ONLY Drawing number parts 2 through 6 may be purchased as a complete assembly part V3002 When replacing the battery align positives and push down to fully seat Correct Battery gt Battery replacement is Orienta E 3 volt lithium coin cell tion type 2032 WS1TC amp WS1 25 TC Manual Page 13 WSITC Drive Ca
5. times in Minutes Program CI C2 C3 C4 C5 Ist Backwash Regenerate 2nd Backwash Rinse Fill 9 s 3 3 m e ao s er Ls m s o m o v s o m e 3 semi s 19 C ou s see az 099 m 6 Sume Super 4 Skipped m o skipped skipped 6 Skipped 5 Hu Skipped Skipped s Skipped NOTE During regeneration the display will show C1 C2 etc If the cycle is skipped that cycle number will not be displayed Noryl is a trademark of Sabic Innovative Plastics IP B V Company WS1TC amp WS1 25 TC Manual Page 5 The user can initiate manual regeneration The user has the option to request the manual regeneration at the delayed regeneration time or to have the regeneration occur immediately Simultaneously press A and V to start a regeneration at the next delayed regeneration time If a regeneration is to occur today an arrow will point to REGEN For immediate regeneration simultaneously press and hold A and V for three seconds When in regeneration step through the different regeneration cycles by pressing A or V Page 6 WS1TC amp WS1 25 TC Manual OEM General Instructions The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation These procedures are e OEM System Setup e Installer Displays amp Settings either 1 99 Days Between Regeneration option or 7 Day option e User Displays
6. to go to the next step STEP 3ID Regeneration Time Minutes Set the time for regeneration to start using A or V Press SET to go to the next step STEP 4ID Days to Regen Set the number of days between regenerations The allowable range is 1 to 99 Press SET to exit Installer Displays and Settings Installer Displays amp Settings 7 Day Option STEP 117 From normal mode press SET A simultaneously for 3 seconds and release STEP 217 Regeneration Time Hour Set the time for regeneration to start using A or V Press SET to go to Step 3I7 STEP 317 Regeneration Time Minutes Set the time for regeneration to start using A or V Press SET to go to Step 4I7 STEP 417 Current Day of Week Set the current day of the week by using A or V See chart at right for date codes Press SET to go Faye a6 mw WS1TC amp WS1 25 TC Manual STEP 517 Regen Time Min Fill PM Regen Days To Time Regen co m A TEP 617 Regen Time Min Fill Regen Time Days To Regen sp v z co m A STEP 717 Regen Time Min Fill PM Regen Days To Time Regen co m A TEP 817 Regen Time Min Fill Regen Time Days To Regen f I n m a STEP 917 Regen Time Min Fill PM Regen Days To Time Regen co m a STEP 101I N Time PM Days To Regen Regen Min Fill Regen Time SET S 5 p p N Time PM Days To Regen Regen Min Fill Regen Time
7. These procedures can be accessed in any order Details on each of the procedures are provided below and on the following pages When in operation normal user displays show the time of day or days remaining before regeneration When stepping through a procedure if no buttons are pressed within five minutes the display returns to a normal user display Any changes made prior to the five minute time out are incorporated To quickly exit Installer Displays amp Settings or OEM Setup simultaneously press SET V Any changes made prior to the exit are incorporated To reinitialize the control valve check to make sure the valve is in the User Display Then simultaneously press SET V or unplug power source plug 4 pin connector on the circuit board wait 3 seconds and plug back in STEP 1SS OEM System Setup w A ill STEP 1SS From normal mode press SET A buttons simultaneously for 3 seconds and release Then press SET A simultaneously for 3 seconds and release co m IL w STEP 2SS STEP 2SS Choose the desired program by pressing A or V Prior to selecting a program verify the correct valve body main piston regenerant piston and stack are being used and that the injector om or injector plug s are in the correct locations See Valve Body Compliance Table in the WS1 and Regen WS1 25 Drawings and Service Manual EA IV Press SET button to go to Step 3SS Regeneration Cycles and Times for Different Programs
8. Water Specialist 1 Control Valve Series Model WS1TC 1 25 Control Valve Series Model WS1 25TC Operation and Instruction Manual for OEM Only Please Note This operation and instruction manual is for the training of the OEM and for the OEM to use to train their customers This document is not to be used as the complete system manual MANUAL REGENERATION Arrow will point to Regen if a NOTE For softeners if brine tank does not regeneration is expected Tonight contain salt fill with salt and wait at least 2 hours before regeneration ue If you need to initiate a manual regeneration Min Fal PM legen l Days To either immediately or tonight at the ume Regen preprogrammed time typically 2 a m complete the following steps For Immediate Regeneration Press and hold A and Y simultaneously until valve motor starts typically 3 seconds For Regeneration Tonight Press and release A and W simultaneously notice that arrow points to Regen If the display shows E1 E2 E3 or E4 for error call a service technician To shut off water to the system please position arrow handles as shown in the bypass operation diagram below If your valve doesn t look like the diagram below contact your service technician for instructions on how to shut off water NORMAL OPERATION BYPASS OPERATION Treated Supply Water Supply Water Supply Water Water Exits Enters Enters
9. butor Tube Opening Identification Spacer Color Black Grey Plug 1 5 WS1 25 with 32mm Distributor Tube Opening Identification Spacer Color Black 1 5 Grey Plug Grey Ring 15 Grey Distributor O ring Retainer Page 16 WS1TC amp WS1 25 TC Manual Form No V3115TC 04 12 7 2010
10. e products currently on the market Control valve installation is made easy because the distributor tube can be cut 4 above to 4 below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distributor baskets The AC adapter comes with a 15 foot power cord and is designed for use with the control valve The AC adapter is for dry location use only The control valve maintains timekeeping for up to 8 hours if the power goes out and the battery is not depleted After 8 hours the only item that needs to be reset is the time of day valve status and programming are permanently stored in the nonvolatile memory If a power loss lasts less than 8 hours and the time flashes on and off the time of day should be reset and the non rechargeable battery should be replaced Table 1 shows the time for the backwash regenerative and rinse cycles for the ten available programming options Six different programs are available for a softener one for a regenerative filter and three programs for backwash only filters When the control valve is used as a Softener one or two backwashes occur and refill always occurs after the rinse cycle PO through P5 Regenerative Filter one backwash occurs and refill always occurs after the rinse cycle P6 Backwashing Filter one backwash occurs P7 through P9 Table 1 Regeneration Cycles and Times for Different Programs All
11. ed Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as a manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a manual regeneration at the preset delayed regeneration time simultaneously press A and Time Min Fill PM Regen Days To Time Regen An arrow will point to the word Regen if a regeneration is expected tonight V and release The arrow will point to the word Regen if a regeneration is expected tonight To Regen a cancel the regeneration simultaneously press A and WV and release een Time To initiate a manual regeneration immediately simultaneously press A and W for three seconds The system will begin to regenerate immediately The request cannot be cancelled a AIV Note For softeners if brine tank does not contain salt fill with salt and wait at least two hours before regenerating WS1TC amp WS1 25 TC Manual Page 11 Set Time of Da PA V STEP 1U Press SET Regen Time STEP 2U Current time Adjust hour with A or V With 60 Hz line frequency detection on Fia PRU to power up timekeeping is 12 hour with PM indicator With 50 Hz line frequency detection on ue ae power up timekeeping is 24 hour without the PM indicator Press SET to go to Step 3U Tu STEP 3U Adjust minutes with A or V Press SET to exit Set Time of Day wu aid aoe i
12. eration will not occur on Saturday Press SET to exit Installer Displays amp Settings NOTE If all arrows are turned off in d1 d7 the program will default to d7 WS1TC amp WS1 25 TC Manual Time Days To Regen Time Days To Regen Page 10 User Displays General Operation Min Fil 7 Regen Time When the system is operating one of two displays will be shown Pressing A or V will alternate between the displays One of the displays is always the current time of day The second display is the SEF days remaining until the next regeneration If the days remaining is equal to one a regeneration will occur at the next preset regeneration time The user can scroll between displays as desired Regen a If the system has called for a regeneration that will occur at the preset time of regeneration the arrow en will point to Regen dme Regeneration Mode Typically a system is set to regenerate at a time of low water usage An example of a time with low water usage is when a household is asleep If there is a demand for water when the system is regenerating untreated water will be used Regen When the system begins to regenerate the display will change to the Regeneration Cycle Display to indicate the current regen cycle step and time remaining An arrow will also point to Regen The system will run through the steps automatically and will reset itself to provide treated water when the regeneration is complet
13. es a regeneration will occur immediately if no arrow points at Regen Time or a regeneration will occur at the delayed regeneration hour if an arrow points at Regen Time Use A or V to switch between the two choices If a differential switch is not installed the settings in this display are ignored Press SET to exit OEM system setup NOTE A regeneration will be initiated or scheduled after the control has received a signal for two minutes to the DP Input Item A A Differential pressure switch connection B Motor wire connection C AC adapter wire connection Page 8 co m U ES PE 3 E J TEP 2ID Regen Time Min Fill Regen Time Days To Regen c m E lt pe E Dn dzEZ 3254 u LED amp e3 90 0 34 o TEP 3ID Regen Time Min Fill PM Regen Days To Time Regen Return to Normal Mode DM s S p p N co mMm u TEP 217 Regen Time Min Fill Regen Time Days To Regen v ceo m 4 TEP 317 Regen Time Min Fill Regen Time Days To Regen a n co Im 4 STEP 417 Time PM Days To Regen Regen Min Fill Regen Time co m 4 WS1TC amp WS1 25 TC Manual Installer Displays amp Settings 1 99 Days Between Regeneration Option STEP 1ID From normal mode press SET A buttons simultaneously for 3 seconds and release STEP 2ID Regeneration Time Hour Set the time for regeneration to start using A or V Press SET
14. for approximately 3 seconds The number of days between regenerations may need to be varied based on usage and water Press SET to complete and return to conditions This step will not appear if normal operation the 7 day clock option is selected Accessed by pressing SET and A simultaneously for about 3 seconds Set number of Days between regeneration cycles Table of Contents Control Valve Function and Cycles of Operation nitet e RR ERE e eth e E ei ip eats OEM General Programming Instructions essent nennen enr EE a a Ia aa iiias entree aesa asana OEM System Setup oU POE REGE d RES ERR De eda ete diei Installer Displays Settiligs i ror tert eret re ette e et e HU HIR REESE RER EHE EXE E LEE HT MOS aR EES User Displays Seltings 15 ono eet ae eai liae acte ge vine std Sc PR er gebe evene Drawings and Part Numbers Front Coyer and Drive Assembly 4 i i oia ip ect be ibi be ote ede ii eig e cles pesa dibdn eon WSITC Drive Cap Pistons and Spacer Stack cec tinere trente cie tenaci ie rasta aei WSL2STC Drive Cap Pistons and Spacer Stack 2 t ette rtr rt rre i eei bidon WS1 amp WS1 25 Identification Figure occ itinere ect teta i a ri de ee aeta cie FOR INFORMATION COMMON TO ALL 1 amp 1 25 CONTROL VALVES REFER TO THE WS1 amp WS1 25 DRAWINGS AND SERVICE MANUAL Page 4 WS1TC amp WS1 25 TC Manual Control Valve Function and Cycles of Operation This glass fi
15. lled Noryl or equivalent fully automatic control valve is designed as the primary control center to direct and regulate all cycles of a downflow regeneration water softener or filter The time clock control valve can be set to perform downflow regeneration or simply backwash The time clock control valve has two calendar options for regeneration frequency 1 An option where the user can choose the number of days 1 99 between each regeneration and 2 A seven day option where the user can choose which day s of the week a regeneration should occur The control valve is compatible with a variety of regenerants and resin cleaners The control valve is capable of routing the flow of water in the necessary paths to regenerate or backwash water treatment systems The injector regulates the flow of brine or other regenerants The control valve regulates the flow rates for backwashing rinsing and the replenishing of treated water into a regenerant tank when applicable The control valve uses no traditional fasteners e g screws instead clips threaded caps and nuts and snap type latches are used Caps and nuts only need to be firmly hand tightened because radial seals are used Tools required to service the valve include one small blade screw driver one large blade screw driver pliers and a pair of hands A plastic wrench is available which eliminates the need for screwdrivers and pliers Disassembly for servicing takes much less time than comparabl
16. p Assembly Downflow Piston Regenerant Piston and Spacer Stack Assembly V3005 WS Spacer Stack Assembly V3004 Drive Cap ASY s ws oms O O varos oxmszisiDisibwertu m Not Shown 1 V3001 02 WS1 Mixing Valve Body ASY Note The regenerant piston is not used in backwash only applications Black Plug Page 14 WS1TC amp WS1 25 TC Manual WS1 25TC Drive Cap Assembly Downflow Piston Regenerant Piston and Spacer Stack Assembly dus ves Somes O OOOO U y E Po O ring 219 Distributor Tube Opening 1 32 V3357 O ring 218 Distributor Tube Opening 32mm V3020 WS1 25 Body ASY Downflow Distributor Tube Opening 1 32 V3020 01 WS1 25 Mixing Valve Body Downflow ASY Distributor Tube Opening 1 32 Not Shown V3020 02 WS1 25 Body ASY Downflow Distributor Tube Opening 32mm V3020 03 WS1 25 Mixing Valve Body Downflow ASY Distributor Tube Opening 32mm Note The regenerant piston is not used in backwash only applications N Grey Plug on all WS1 25 bodies Se Grey Ring Grey Distributor O ring retainer Only for valves that have a 32mm Distributor Tube Opening WS1TC amp WS1 25 TC Manual Page 15 WS1 amp WS1 25 Identification Figure WS1 with 1 050 Distributor Tube Opening Identification Spacer Color Grey Black Plug x 1 25 v Note The WS1 downflow piston is a solid amber color WS1 25 with 1 32 Distri

Download Pdf Manuals

image

Related Search

Related Contents

DuckBill DuckBill DuckBill  UTL260 - SupplyHouse.com  オキシリンク-フォグ    KWORLD HDMI 321 - Laserelectronic    SRS 20/II - Greiner Bio  IRSS1611 Steam Iron User Manual IRSS1611 Steam Iron User  Eglo 200386A Instructions / Assembly  Gigaset S810/S810A  

Copyright © All rights reserved.
Failed to retrieve file