Home

Super Flow 1 Dry Vacuum System Super Flow 2 Dual Dry Vacuum

image

Contents

1. ALLOW ANY PIPE IMPORTANT TO BRANCH OFF ANOTHER TO PREVENT SUCTION LOSS DO NOT ALLOW A TRAP PIPE BELOW THE CENTERLINE TO BE PLUMBED AT ANY LOCATION IN THE SYSTEM OF THE MAIN OR BRANCH LINE EXCEPT MAIN LINE RISER ASSEMBLY FIG 1 ANO PIPE SEE FIG 6 FOR CORRECT OVERHEAD VERTICAL RISER FIG 5 BRANCH LINE TAKE OFF DHP Dry Vacuum Pre Installation DHP Dry Vacuum Specifications Vacuum Line See Chart Page 4 Dansereau Health Products Inc strongly recommends Schedule 40PVC for use as the Vacuum Line However be aware some Building Codes require a metal type vac Surface Mt J Box lil uum line and require Copper as the Vacuum Line Cop B per will eventually deteriorate over years of service jy Schedule 40 PVC will not NOTE IF YOUR VACUUM Uj LINE INSTALLATION IS OUTSIDE THE SCOPE ech dae LISTED BELOW CONTACT DANSEREAU FOR SPECIAL INSTRUCTIONS Ou Operatory Termination See Vacuum Sizing Chart for Specs En BE cx 5 DWV Sanitary T Sch 40 PVC f b E e D S V Ke uet To Vacuum System Qe ma Site Requirements Environment Conditions Operating Conditions Indoor use at altitudes up to 2000M Temperature 5 to 40 Degrees C 41 to 104 F Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity to 40C Supply Voltage fluctuation of 10 of nominal voltage IEC 60601 1 Not suitable for use in the presence of
2. Pure e Operators must flush lines and then allow air from open vacuum line to run in order to ensure com plete liquid non foaming vacuum line cleaning solution has run through the system Vertical Pipes Must Tee Into Top Pop E 1 of Horizontal Overhead Pipe SJ 9 6 fo General Principles for Vacuum Lines a Slope a minimum of 1 4 in 10 feet with the low end towards the tank b Sonitory Yer If an in line low spot is unavoidable place it in a known loca Qo tion and incorporate a Clean Out ae B T Confirm All Local Building Codes prior to beginning plumbing 8 DHP Dry Vacuum Specifications Electrical Requirements LINE VOLTAGE Single phase 240v 50 60hz electricity is required for proper opera tion of the D H P Dry Vacuum System All electrical sources to the DHP Vacuum Pump MUST BE PROPERLY GROUNDED All DHP Dry Vacuum Systems are operated by a LOW VOLTAGE SWITCH or the AUTO WASH DOWN SYSTEM WILL NOT OPERATE LOW VOLTAGE A 18 8 low voltage rated wire should be run from one central loca tion to allow the DHP Dry Vacuum System to be turned on and off Plumbing Requirements WATER LINE A 1 2 cold water source is required for proper operation of the DHP Dry Vacuum System Wash Down A 1 2 shut off valve is required at end of the water source Cold water is an important requirement for the proper operation of the DHP Vacuum Pump WASTE LINE The industry standard for exhau
3. aud Pips Con Get Het FinizFed FI Finished Floor Tubing waeuurm Motor T 1 Mom P Trap Local Bullding Gedas May Require Trop Pri nmar Te Publle Wasta Draln The above DHP Super Flow Dry Vacuum System Vacuum installation elevation is a typical installation It should be noted that local building codes will supersede any recommended installation guidelines in this manual DHP Dry Vacuum Specifications Specifications Voltage 230 VAC Hz 50 60 If 208 Present Buck Booster Required Output H P 2 Current Amps 11 Free Delivery CFM 70 Vacuum In Hg 16 max 8 continuous e Weight Ibs 97 e Width inches 16 Length inches 20 Height inches 16 e Tank gallons 16 e Includes Low voltage control separator tank with automatic drain and check valve Copper NO LONGER RECOMMNDED FOR VACUUM LINES OR VENTING Vacuum Line Dry Vacuum System Number of Operatories Diameter PVC Sch 40 een tue Assembly Diameter PVC Sch 40 DHP Dry Vacuum Pre Installation Typical Errors in Plumbing Vacuum Lines BRANCH LINE TERMINATION TO TWO OPERATORIES E amp E 4 B t s d bs d gt 2 MO o P lt y V M i p pat o i Y 2 aft ev bs E e e gt THIS BRANCH LINE TERMINATION IS SHOWN CORRECTLY NEVER USE THE INCORRECT EXAMPLE SHOWN AT LEFT FOR VACUUM SYSTEMS Typical Errors in Plumbing Vacuum Lines MOST COMMON VACUUM PLUMBING ERRORS DO NOT
4. Dansereau Health Products Inc Super Flow 10 Dry Vacuum System Owner s Manual Manufactured at 1581 Commerce Street Corona 92880 USA Phone 800 423 5657 International Phone 951 549 1400 Fax 951 549 1411 Website WWW DHPDENTAL COM E MAIL Harry dhpdental com Dansereau Dental Super Flow 10 Dry Vacuum Table of Contents Section 1 Vacuum Pump Section 2 Pre installation Guide Section 3 Unpacking Section 4 Installation Section 5 Maintenance Section 6 Trouble Shooting Guide DHP Dry Vacuum Pump Dansereau Health Products has been producing dental equipment for over 45 years The information contained in this manual is a compilation of facts collected over those 45 years The Super Flow Vacuum System is a Dry Evacuation System with a Tank Wash Down System to keep the Storage Tank clean The Super Flow Vacuum System is available in 230 volt 50 60 Hz electricity only Less than 230volt electricity will require a Boost Transformer World Wide Toll Free Access DHP has instituted a toll free telephone service in the United States Canada and Mexico Our Tele Fax line 951 549 1411 is available 24 hours a day Toll Free Phone U S A and Puerto Rico 1 800 423 5657 Canada 1 800 423 5657 Mexico 095 800 423 5657 E Mail Address Parts DHPDENTAL COM For Customer Service Questions Customer Service DHP customer service in house technicians have a minimum of 10 years experience in the manufa
5. a flammable anesthetics mixture with air or with oxygen or nitrous oxide Class 1 Installation Category Ordinary equipment IPXO Does not protect against ingress of water Unit is suitable for continuous operation T DHP Dry Vacuum Pre Installation OVERHEAD PLUMBING Overhead plumbing for dental vacuum lines are not recommended Our experience in the long term there can be issues with quality of vacuum However if it is required based upon existing conditions in a dental office economic considerations or construction limitations you will need to be exact in following the rules listed below Incorrect installation of overhead vacuum piping will ensure low quality or non existent vacuum pressure Plumbing Rules for Overhead Piping e Keep the vertical lift height as short as possible e he vertical pipe must tee into the top of the horizontal line e Run the vertical line in 1 2 pipe e Run the horizontal overhead line in 1 1 2 or preferably 2 size pipe For more than 5 Operatories consult with Dansereau e Nitrous oxide scavengers must run in a separate vertical pipe and tee into the top of the horizontal line in a separate location from the wet vertical pipe Pump Sizing Rules for Overhead Piping e Dry Vacuum System is only recommended Vacuum System e Consult with Dansereau on Overhead Piping Line Size Operator Rules for Overhead Piping e Operators must use Non Foaming Vacuum Line Cleansers Recommended Bio
6. cturing installation and maintenance of the DHP vacuum pump Approved Testing Laboratories City of Los Angeles Building and Safety 7BD ETL Testing Laboratories File Number ETL LISTING TBD Canadian Standards Association File Number CSA LISTING TBD DHP Vacuum Pump Pre installation Guide Location The DHP Super Flow Vacuum System should be installed in a well ventilated area The DHP Super Flow Vacuum System is air cooled and without proper air circulation the lifespan of the vacuum pump could be shortened significantly The sound level of the vacuum pump when in operation is very quiet and can be placed within a dental facility The ambient temperature in the dental office equipment room should never ex ceed 40 degrees Fahrenheit minimum and 100 degrees Fahrenheit maximum The dental office equipment room will require a minimum 5 air changes per hour which can be met with a 50 CFM vent fan in a 5 x 5 x 9 room However if an Air Condition ing Supply and Return is available it is HIGHLY RECOMMENDED to ensure heat controls in the Utility Room NOTE THE SUPERFLOW DRY VAC CAN BE INSTALLED SIDE BY SIDE OR STACKED Super Flow 10 Ory Vacuum System dacuurm oth c nccnemenic iir mn oC ee T IH VENTING er wou RITER FRO eC eed caked Giraut Central Pang Low voltage Li ts tha Cantr l Paral Must hava 1 Gap Tem tu Habras ard af Tank asta mperature and Floor Sink CATCH Frama vacum Pumqg kotar WI Zak akata
7. ill ensure you that your Super Flow Dry Vacuum system will give you years of op eration A Particulate Matter Filter Inspe Monthly for Moisture This is a key indicator that liquid foam is be Sucked Up from the Separator Tank into the Turbine This will also restrict air flow causing the motor to overheat and prematurely fail If you have moisture or liquid in this filter contact Dansereau immediately How to Inspect the Filter 1 Turn off Vacuum System 2 Wearing Gloves and Mask lift the retain brackets 3 Lift Top of Filter and Inspect B Separator Tank Waste Line should be inspected to ensure waste if flowing after the Dry Vac uum system is turned off When Vacuum System is turned off flow of waste from Separator Tank is immediate Visual inspection is adequate C Wash Down System inspection The Super Flow has an integrated Wash Down System on timer Approximately 5 Min utes after shut down of the Vacuum System Wash Down will commence for approximate 1 minute 1 Gallon of Water is used to rinse the inside of the Sepa rator Tank If you experience more that approximately 1 minute or excessive water during the wash down cy cle contact Dansereau immediately 11 Dansereau Super Flow 10 Installation 1 Electrical installation must be performed by an licensed Electrician 2 Low Voltage Controls must be installed to properly operate the wash down system 3 Dry Vacuum Motor must be properly grou
8. l assembled It will arrive ready to install with no product assembly required 2 Set the Super Flow 10 into the Utility Room making sure there is ade quate air flow and clearances around the system Noting this Is an air cooled system and good air flow is imperative In some cases we have seen dentists have an air conditioning duct run into the Utility Room Operatory Intake F Low Voltage Control Wires Do not cross will result in failure of low voltage transformer Vacuum Waste Line to drain waste into public waste receptacle Floor Sink is recommended Wash Down Water Source Blue Hose Not in Picture Wash Down System is not required for opera tion but will eliminate tank cleaning maintenance Turbine Exhaust Vent Electrical Power Source Line Not In Picture 240V required opecial Note Do not adjust the CFM on the Vacuum System unless you consult directly with the Dansereau as over adjusting the CFM may cause particulate matter to be drawn into the Vacuum Motor A Particulate Matter Filter is in place to prohibit the introduction of matter from the Storage Tank into the Vacuum Motor but over adjusting the CFM will strain the Particulate Master Filter and cause motor damage 10 Dansereau Super Flow 10 Maintenance The Super Flow 10 Dry Vacuum system is virtually a maintenance free vacuum sys tem A few items to inspect during operation and proper vacuum line maintenance w
9. nded 20 MDL 5 AMP 24V FUSE FUSE HOLDER TOGGLE SWITCH REMOTE SWITCH OFF WASH DOWN T1247K T2 3K9 4 MIN 30 SEC ANE FAN 230V TRANSFORMER a T Af FLUID CONTROL SOLENOID 24 VAC FLOAT MOTOR 220V LINE OUT PUT IN PUT SWITCH 12 Dansereau Super Flow 10 Maintenance Maintenance The Super Flow 10 Dry Vacuum System requires no maintenance or service However as this is a mechanical device we recommend monthly inspections of the system Look for a situation that appears abnormal moisture and noise etc NON FOAMING VACUUM LINE CLEANSERS MUST BE USED DO NOT USE BLEACH TO CLEAN VACUUM LINES IT WILL DAMAGE THE STAINLESS STEEL TANK Dansereau recommends Bio Pure Dental Line Cleaner Call 800 423 5657 for Special Dansereau pricing Twice Monthly check the In Line Particulate Matter filter for moisture or particulate matter If moisture or particulate matter is present contact Dansereau immediately NEVER ADJUST THE PRESSURE RELIEF VALVE Once a Month Inspect the Pressure Relief Valve for Dust and Particulate Matter Trouble Shooting Motor making loud winding sound A Turn off motor immediately and contact Dansereau 800 423 5657 Motor not turning on A Check the fuse at the Electrical Panel in the dental facility B Check the Fuse on the Super Flow Dry Vacuum C Check the connections on the low voltage control panel D Contact Dansereau immediately 800 423 5657 Introduction of any fo
10. re contact Dansereau Immediately Replace the filter ad justments will need to be made of to the dry vacuum system to ensure no premature failure occurs Dansereau s warranty does not imply or express any conse quential damages will be covered under this warranty Labor and shipping costs will be borne by the user 14
11. reign matter into the vacuum motor will damage the integrity of the motor and may void the warranty We have installed a par ticulate matter filter to prohibit the foreign matter passing through to the vacuum motor However if you are using Air Abrasion you must have an In Line Filter Failure to use the appropriate filter will void your warranty 13 Dansereau Super Flow 10 Maintenance Warranty 1 Year Solenoid Valve Internal Relay and Tank Sensor Electronic components are covered by 1 year Shipping labor and installation costs are borne by the user 3 Years Turbine Motor The turbine motor is covered for 3 years under normal use conditions If there is excessive heat foreign matter is introduced into the turbine foaming line cleansers bleach or bleach like products are used the warranty is voided Shipping labor and installation costs are borne by the user 5 Years Stainless Steel Tank Stainless Steel Tank and Structure are covered by a 5 year warranty Bleach and Bleach like prod ucts that are used to clean the vacuum lines will void the war ranty opecial note Air abrasion and particulate matter used in air abra sion will damage the dry vacuum system If they are being used an inline filter must be used to eliminate the possibility of dam age Do not use Foaming Vacuum Line Cleaners Bleach or Bleach like products with our Dry Vacuum System Periodically check the Dry Vacuum Filter for moisture if you find moistu
12. sting the Dry Vacuum waste into a floor sink Local Building Codes will require a 1 air gap from the exhaust of the Dry Vacuum Waste Outlet into the floor sink SPECIAL NOTE The Dry Vacuum Motor will require a 2 Inch Vent from the Exhaust of the Motor thru the roof to outdoors It is required that the first 8 feet minimum of the vent pipe from the Dry Vacuum Motor be of metal consistency No Plastic Recom mended Galvanized The exhaust of the Dry Vacuum Motor can be hot over constant usage After the first 8 feet of metal vent pipe you may use a Schedule 80 ABS pro vided there are not bends or angles in the line straight exhaust Vacuum Line The industry standard is a 1 5 schedule 40 PVC line reduced to a 1 schedule 40 PVC line at the operatory Schedule 40 PVC is the only Manufacturer Recommended product for Dental Vacuum Lines Vacuum Pump Specifications Total Horsepower 2 Electrical 240V Buck Boost Transformer may be required if only 208V is present Maximum Users High Volume Evacuation HVE 4 High Volume Evacuation amp Saliva Ejectors 2 HVE amp 4 SE Tank Dimensions Height 36 Inches Depth 21 Inches Width 21 Inches Motor Dimensions Height 19 Inches Depth 24 Inches Width 24 Inches Weight Tank 45lbs Motor 110lbs UNDER NO CONDITIONS SHOULD CONTINUOUS RUN SINKS OR DENTAL CUSPIDORS BE INSTALLED ON A VACUUM LINE Dansereau Super Flow 10 Installation 1 The Super Flow 10 ships ful