         Contents
1.      During lens exchange  the IR detector is exposed  Avoid all contact with the detector  Do not  touch  clean or blow air on the detector  Replacement of the lens must be done in a clean  dry  area  Do not leave the IR detector exposed more than needed for performing the replacement      Do not use pneumatic system pressurized air to remove dust from the Therm App device   Pressurized air contains oil mist intended to lubricate pneumatic tools  this type of a  pressurized air could damage the detector and lens      Power the Therm App device with 5V DC connected through the micro USB connector only  by  connecting it to a smartphone or other USB host connector  Using any other type of power  source may damage the Therm App device    m Use only the USB OTG cables provided with the Therm App device  Using any other types of  cables could damage the equipment      A label tamper is attached to one of the screws on the back of the Therm App device   Removing this label or the S N label voids the warranty      For more information  FAQ  and updated device compatibility views  please visit the Therm   App website  http   www therm app com     Document  UM TAH68AQ 1100_ A Page 4 of 23    Safety and Caution Notes Therm App Operation Manual      As with most electronic products  Therm App device must be disposed in an environmentally  friendly way  and in accordance with existing regulations for electronic waste  Please contact  our support team at http   www therm app com for more
2.     Check this checkbox If you use your dropbox  account for transferring Therm App TH outputs to the Therm App TH   s PC  analysis and reporting software     Note  marking all check boxes will create more copies of the images and will  allow for accessing the outputs and checking images on the devices    gallery  apps  exporting to the reporting and analysis PC software  and to DropBox   but will consume more memory space     Document  UM TAH68AQ 1100_ A Page 19 of 23    Application Operation Therm App Operation Manual    Bad Pixel Repair    During extensive operation of the thermal sensor  or due to mechanical  shocks  some of the pixels may need repair  Bad pixels are observed as  pixels that are darker or brighter than their surroundings  To eliminate these   pad pixels  press    Run Bad Pixel Repair     gt  Start and follow the on screen aan PIXELS REPAIR  instructions        Run Bad Pixel Repair    Detect and repair bad pixels   Perform ONLY when bad pixels are observed     Restore factory settings    Document  UM TAH68AQ 1100_A Page 20 of 23    Application Operation Therm App Operation Manual    Specifications  Resolution 384 x 288 pixels   gt 110 000 pixels    Accuracy   2  C or 2    25  C  whichever is higher  Sensitivity NETD  lt  0 10  C  Scene Temperature range 0     200   C  NUC calibration Shutterless  Calibration Routine Est  2 years  Hardware  Imager 384 x 288 microbolometer  LWIR 7 5  14um  Optics 6 8mm lens  55   x 41     Focus Range 0 6m to Infinity  Frame 
3.    mApPP     l I  more to see     Therm App TH for Thermography    High Resolution    Mobile Thermal Imaging Tool       Operation Manual    Quick Start Guide Therm App Operation Manual    Copyright    2014 Therm App  All rights reserved     Thema ADDO    more to see   Visit Therm App   website  www therm app com      Si  eG   219 S10    0    eee ee ee eee ee ee 3  oalety and CaUUON NOES sesa TR 4  FP OGUC TID SSC TIT OIA a rascsoen esta nasemascivaeieaan sein xm cmasoneameaen emeumacmaia eknemennsenamanasiaementnunraanadtis 6  Android Device Minimum Requirements               ccccccceseeeeseeeeeeeeeseeeeeeeesaeeeeneeeeas 7  Opening the Therm App BOX            ccccccccecssceeceeceeeeeeeseeesesseeesseeeesaaeeesseeeseeeeeeas 8  MUST OM AU S A eA E EE E EE E EE E E A E E A A E EET 8  APOI BOR ODE AO rE RE E EERE 10  Troubleshooting           ccccceccceececeeeeceececaeeeceeeeseueeseueeseueessueeseueeseueesaueeseneeseneessnees 22    Document  UM TAH68AQ 1100_A Page 2 of 23    Quick Start Guide    Unpack Therm App package     Make sure the Android device is compatible with  the Android Device Minimum Requirements     Visit the Google Play online store and download  the free Therm App Basic app  or scan the QR  code     Install the Therm App basic application on your  Android device     Verify that you have a stable internet connection     Insert the Android device  3  into the Therm App  device Attachment bracket  2  and carefully  fasten the Size knob  1      Connect the Android d
4.   in the Attachment brackets  2      m Attach Therm App to the back of the mobile  device by turning the size knob     m Fasten the Size knob  1  and the Attachment  bracket  2  to fit the Android device  Ensure that  the device is firmly attached     Note  Do not fasten the size knob too tightly   Fastening the size knob too tightly could damage  the Android device       Connect the USB OTG cable to both Therm App   2  and the mobile device  1        Note  Use only the USB OTG cable supplied  In  most cases  the micro USB cables supplied with  mobile phones do not support the USB OTG  functionality     Note  Verify that the USB OTG cable is  connected properly to the _Therm App device and  to the mobile device    Once it is a connected a USB connector  connected  or similar  message should be  shown and the Therm App application  if already  installed  should start automatically        Notes  For the first use of the Therm App device  with an Android device  an initialization process  that involves downloading of data must be  completed  This process may take a few minutes  and must not be interrupted  Make sure you  have a stable high speed internet connection   preferably WiFi  prior to connecting your mobile  device to the Therm App device     Document  UM TAH68AQ 1100_A Page 9 of 23    Application Operation Therm App Operation Manual    Initialization      This section is relevant to the first connection between the Therm App a  device and the Android device     m The An
5.  Note  Most off the shelf cables are not USB OTG and will not operate with the  Therm App device  Use only the USB OTG cables that are provided with the product     Below is a partial list of supported devices  For an updated list visit  http   therm app com therm   app supported devices       LG  Nexus 5  G2  Flex      Samsung   Galaxy Note 1  Galaxy Note 2  Galaxy Note 3  Galaxy Note 4  Galaxy Note 4 Edge   Galaxy S3  Galaxy S4  Galaxy S5  Galaxy Express  Galaxy Mega 6 3     m Sony  Xperia Z  C6603  Xperia C  Xperia Z1  Xperia Z3  Xperia Z3 compactXiaomi     HongMi   HM 1SW  MI 2  MI 2S  MI 3    m Zopo  C3  HTC  One  M7      Android 4 3 and up   Motorola  Moto G    Document  UM TAH68AQ 1100_A Page 7 of 23    Opening the Therm App Box Therm App Operation Manual    The Therm App TH carry case contains     Therm App TH device with 6 8mm lens E N    E   m 15 cm right angle USB OTG cable Therm APR TH    15cm left angle USB OTG cable   m 21cm straight USB OTG cable     Handle    m Quick start guide       Installing the Application      Make sure the Android device operating system   OS  is either version 4 1 or above excluding 5 0  and above  supporting USB On The Go      Visit the Google Play online store  download and    install the free Therm App Basic app  or scan the  QR code  m       Document  UM TAH68AQ 1100_A Page 8 of 23    Installation    Therm App Operation Manual    Connecting Therm App to the Android Device      Turn the Size knob  1  so the Android device  Slides  3
6.  details     Document  UM TAH68AQ 1100_A Page 5 of 23    Product Description Therm App Operation Manual    Therm App is a revolutionary concept that extends human vision by turning an Android device into a thermal  camera  This lightweight  modular  high resolution device clips onto your Android device  Therm App provides  your Android device with a capability of a powerful camera  able to display  record  and share thermal images     Therm App runs an entirely new suite of exciting night vision and thermography applications     Therm App combines the power of a fully functional thermal camera with the mobility  connectivity  processing  power  display capabilities and advanced features provided by Android devices today     QO        The Therm App device main  components     Therm App device housing  1    Lens  2  with manual focus   Grip Handle  3    Attachment bracket  4      connects the Therm   App device with the Android device    m Size knob  5      for adjustment to fit different sizes  of Android devices      OTG USB cable  6      for communication with the  Android device        Document  UM TAH68AQ 1100_A Page 6 of 23    Android Device Minimum Requirements Therm App Operation Manual      Therm App was designed to work with Android OS ver  4 1 or above  Due to modifications and  variations made by mobile manufacturers and operators there could be cases of non   compatibility      Android device supporting USB OTG  On The Go  also Known as USB HOST mode      Important
7. Rate 8 7Hz  Weight 123 grams   4 33 ounces  Size 55 x 65 x 40mm 2 16  x 2 55  x 1 57    Operating Temperature  10  C to  50  C  14  F to  122  F   Storage Temperature  20  C to  50  C   4  F to  122  F   Power Supply No battery  5V over USB OTG cable  power consumption  lt  0 5W  Certifications CE  FCC  RoHS  WEEE  Ingress protection  IP  rating IP 54   IEC 60529   Visible camera Depending on Android device used  Mount   Handle Ergonomic handle  using 1 4  standard tripod interface  Device Attachment Clip on for smartphone  5  10cm span   Smartphone  Minimal requirements Android 4 1 and above  supporting USB OTG    High Resolution touch screen Yes  by the Android device used     a       Annotations Text   Video annotations   Output Video   Audio  h 264   Snapshot  IR   VIS   Metadata    Cloud Share Dropbox   Android Share Via Android   s media gallery functionality to multiple services   Color Palettes Rainbow  Iron  Vivid  Grayscale  Red Hot Thershold  Blue Cold Thershold  Temperature Scale Range Auto  Manual   Zoom Digital touch screen gesture   Bad Pixel Repair Self supported user function   Background  reflected  Yes   compensation    Software and feature updates Yes  via Google Play applications update mechanism     Document  UM TAH68AQ 1100_ A Page 21 of 23    Troubleshooting Therm App Operation Manual    Before starting any troubleshooting procedure  make sure that       The Android device is compatible with Therm App     The Therm App Basic application is installed fr
8. ax temperatures       Temperature reading  6      displays the temperature at the center of the  image  marked by the cross hair        Note  In nightvision mode the temperature is not presented     Lower Toolbar    The lower toolbar includes      Gallery  1      displays pictures stored in the Android device using default  album application      Photo  2      takes a photo    m Video  3      starts video recording        Document  UM TAH68AQ 1100_ A Page 11 of 23    Application Operation Therm App Operation Manual    Setting Thermography Color    When the Thermography mode is selected  the Therm App device image  can be displayed using one of four palettes     To change the selected palette     Swipe the main screen left or right to toggle between palettes  or tap the  Thermography Color option on the Therm App Settings screen                  Select one of the following palettes     Rainbow  lron   Vivid  Grayscale    Note  In nightvision mode there are two grayscale palettes    Hot white   cold black and Hot black   cold white     In addition to the color palettes  you can choose one of two functional  palettes presenting    Hot Threshold    and    Cold Threshold     Once setting the  hot threshold  only items with temperature readings above the threshold will  be colored in Red  and the rest will be in grayscale        Once setting the cold threshold  only items with temperature readings below  the threshold will be colored in Blue  and the rest will be in grayscale     A
9. ck box on the  interrupts Therm  to sleep mode  Therm App Settings screen   App   Therm App The Android device Unplug the USB OTG cable     application is not switches to Safe mode  Restart the Android device   found  Connect the Therm App device with the Android device     Application screen   A messages screen Press the Android Home button to exit the App and  is not displayed appears on App startup reconnect Therm App and the Android device     No active view Camera view is not From the Apps menu  select My files  gt  All files  gt   displayed after Thermapp   completing app initial Delete folder with a serial number tag   setup Re install Therm App Basic application   Plug the Therm App device again     Video not Blank screen Ensure that the Android device is turned on   displayed on the Ensure that the Therm App device lens is not covered or  Android device  blocked   Ensure that USB OTG cable is properly connected between  the Android device and Therm App device        Document  UM TAH68AQ 1100_A Page 22 of 23    Troubleshooting    Problem    System Failure    Noisy image    Unfocused image    Inaccurate  temperature  readings    Document  UM TAH68AQ 1100_A    Indication    Image blurred    Temperature readings are  not as expected    Little dots appear on all  images and videos in  exactly the same spot  Android device overheats  while connected to  Therm App    Therm App Operation Manual    Solution    Ensure that USB OTG cable is properly connected between  the Andro
10. djusting Hot  amp  Cold Threshold     By pressing the threshold temperature indicator just below the temperature  scale  an adjustable gauge will appear on screen  Swipe it left or right for  setting your threshold of choice  By touching anywhere on the screen the  gauge will disappear        Document  UM TAH68AQ 1100_ A Page 12 of 23    Application Operation Therm App Operation Manual    Setting Manual Temperature Scale      By pressing the left or right temperature scale  reading number  a drop down scale allows for  manually fixing the range  After choosing the fixed  temperature  touch anywhere on the screen to  continue      A fixed temperature scale is marked with a  thumbtack icon near the min or max temperature  indication      For cancelling the fixed range touch the cancel   thumbtack icon at the bottom of the drop down  scale        Full Screen Mode      By tapping twice quickly  you can switch between  standard and full screen modes        Digital Zoom      By pinching the screen the image will be zoomed in  and out  When in zoom mode  a magnifying glass  icon with the zoom level appears on the top left  corner of the thermal image        Document  UM TAH68AQ 1100_A Page 13 of 23    Application Operation Therm App Operation Manual    Therm App Settings    Tap the Settings button located on the upper toolbar  The Settings screen is  displayed and includes     iE fice Om ORGRin   lll  E 15 42      Imaging Mode     switches between Night Vision and Thermography  mode
11. droid device asks for your permission to associate the USB port Open ThermApp when this USB  with the Therm App application  device is connected       Select the Use by default for this USB device check box and tap the OK  Use by default for this USB device  The Therm App application  App  automatically starts and displays the  Terms and conditions screen  Review and accept the Terms and  conditions      The App shows the Initializing message and downloads files which are  specific to your Therm App device  per device serial number   When  download is completed  the App displays the Camera View screen        Note  For the most accurate temperature measurement  it is  recommended to use the grip handle and wait at least 8 minutes after  Therm App starts for stabilization     Camera View     Thermography mode       The Camera View screen includes    m Upper Toolbar  1     Image display  2     Lower toolbar  3        Document  UM TAH68AQ 1100_ A Page 10 of 23    Application Operation Therm App Operation Manual    Upper Toolbar    The upper toolbar includes       Settings button  1      for configuring the Therm App TH Settings       Quick access button     allows for quick access to settings needed while  taking measurments      Temperature bar  3      presents the range of temperatures currently  viewed     m The minimum and maximum image temperatures are also functional  buttons  4  5       displayed on both sides of the bar  Pressing them  allows to manually set the min and m
12. evice with the Therm App  device using the USB OTG cable supplied     Therm App application should pop up  automatically and begin downloading of files from  Therm App server    Wait until download and initialization process are  competed  For the first operation of the Therm   App device  downloading may take a few  minutes     Read and confirm the user agreement       The basic application is running and you are    ready to start using your Therm App   Temperature readings accuracy is improved after  warmup time of 8 minutes and when using the  grip handle     Document  UM TAH68AQ 1100_A       Therm App Operation Manual       Page 3 of 23    Safety and Caution Notes Therm App Operation Manual      Attach Therm App to your mobile device with care  Do not use any external tools as too much  pressure might mark or damage your mobile device  Secure locking knob using your fingers  only      Therm App uses specific factory prepared calibration data  If  during prolonged field usage of  Therm App  a degraded performance is noted  we recommend that you send the Therm App  device  for re calibration  Please contact our support team at hitp   www therm app com for  further instructions      For the most accurate temperature measurement  it is recommended to wait at least 8 minutes  after Therm App starts for stabilization      Please avoid any direct contact between your hand and the Therm App device  by using the  grip handle or tripod  during stabilization and while measuring as i
13. he file types in this section you SAVE TO MEDIA FOLDER   allow for using the Android   s native gallery and camera with Therm App m    IR Photo mi   outputs      IR Photo     the thermal image taken by Therm App TH  Screenshot caf      Screenshot     The thermal image and its surrounding data  the  temperature readings  scale colors and temperatures  etc      Color Photo     The native Android camera picture  You can set it to  capture automatically in addition to Therm App TH  for having a IR Photo cal  standard visible light image in addition to the thermal image     Color Photo    SAVE TO EXPORT FOLDER    Screenshot w  Save To Export Folder     Export Folder is a Therm App TH dedicated Color Photo  folder that allows for media to be exported from Therm App to its PC Paw Date 7  reporting software       Row Data     A mandatory file for using the PC analysis and reporting ACTS  software with all data of an image  annotations  metadata  etc     Dropbox    Cunrently linked  MUA   Click to unlink     Upload From Media Folder    Cloud Accounts Upload From Export Folder       DropBox   Therm App outputs can be uploaded automatically to a DropBox  lt   O C    account  Use the    click to link    for linking the Therm App TH app with your  DropBox account     Uplaod from Media Folder     upload files marked for saving on the media  folder  Choose this option for backing up or accessing images from  DropBox  but without using the PC reporting software     Upload from Export Folder 
14. id device and Therm App device    Ensure that nothing is obstructing the Therm App device  view    Check that the camera lens is clean    Ensure that line of sight is not blocked by glass or other  transparent materials    Turn the lens focus ring while pointing the Therm App  device to a sharp edged object    Do not turn the lens focus ring too far as the lens could  slip out of place    Verify that you use the original 6 8mm lens  Calibrationi  will work only for it    If you just turned on the device or you changed the  environmental temperature  e g   went out to the cold   wait for a few minutes until device temperature stabilizes   Disconnect the USB OTG cable when Therm App is not in  use    Run    Bad Pixel Repair    procedure  Enter Settings  gt   General Settings  gt  Bad Pixel Repair    When an Android device is not fully USB OTG compatible  and power consumption exceed normal use   Connect Therm App to a supported Android device       Page 23 of 23    
15. missivity              Tap the Emissivity option on the       Therm App Settings screen              Scroll to the correct emissivity ratio and tap the Set button        Another option is to use the quick access menu while at the camera mode        Document  UM TAH68AQ 1100_A Page 15 of 23    Application Operation Therm App Operation Manual    Adjusting the Reflected Temperature      Reflected temperature represents the energy emitted by the  Surrounding objects and reflected by the measured surface  Setting  this value accurately is important if the Emissivity value is low     To adjust the reflected temperature    Tap the Reflected Temperature option on the  Therm App Settings screen    Scroll to the correct temperature and tap the Set button     Adjusting the Scale Truncation    Within every image frame  the temperature span is calculated and  displayed on the top of the thermography image  Use this parameter to  define the minimum number of pixels  defined by percentage  require to  impact the temperature span calculation  This setting prevents a small  number of pixels to reduce the temperature measuring resolution     To adjust the truncation value      Tap the Scale Truncation option on the     Therm App Settings screen      Scroll to the desired value and tap the Set button        Document  UM TAH68AQ 1100_A Page 16 of 23    Application Operation Therm App Operation Manual       Thermography Settings  Units     choose between Celsius and Farenheit  annega   ull  UE  E
16. mmisivity     change the Emissivity according to the measured item   s  29 Thermography Settings  charestatistic and material   l l MEASUREMENT    Reflected temperatures   improve temperature readings by  adjusting this value for reflected background correction  Units Celsius    Scale Truncation bey  Emissivity 0 95  Reflected Temperature 20  Scale Truncation 0 25    lt  O E    Document  UM TAH68AQ 1100_A Page 17 of 23    Application Operation Therm App Operation Manual    General Settings            Record Audio     Enable or disable audio recording during video Ghhewoga   ul   15 43  reco rding  a General Settings     Watermark on Snapshot      enable or disable the Therm App  watermark on images  Record Audio EA     Disable screen timeout     allows you to disable the devices    default Wat yo    screen timeout for working continuously with Therm App  only valid scissile es    when Therm App is connected and image is shown   Maable Geraen ineo Z     Raw Data Annotations     marking it will make a pop up screen to  appear after each photo is taken  where you ll be able to add Raw Data Annotations a    annotations to the photo     Document  UM TAH68AQ 1100_A Page 18 of 23    Application Operation Therm App Operation Manual    Export Save Options       Therm App TH has user customizable media creation and saving options  TnT y EN   Save To Media Folder     Media folder is the Android device   s native camera    A  export save Options   images and videos folder  When marking t
17. mode              Tap the Imaging Mode option on the Therm App Settings screen        Select one of the following modes       Thermography   image pixels are colored in relation to their  temperature  On the default rainbow palette  the blue indicates  the coldest measured temperature and red represents the hottest  temperature measured  This mode is useful with applications  searching for temperature differences on the scanned scene   The color palette is selectable       Night Vision     the default pallete displays image using 256  shades of gray  This mode displays more detailed image  useful Thermography  for human observation during surveillance and detection  In night  vision mode image quality is enhanced but temperature  information is lost  two pixels with the same color might have  different temperature         Notes  Temperature measurements are stabilized about 3 minutes after  activating the Therm App TH device  connecting the USB cable      Thermography measurement might be influenced by the environment of  the measured objects  the surrounding objects reflected temperature   and the measured object emissivity     Adjusting Emissivity    Emissivity is a characteristic of the material being observed  Emissivity is the  ability of the material surface to emit energy by radiation  The emissivity  value  0     1  represents the ratio of energy radiated by the material being  observed to the energy radiated by a black body at the same temperature     To adjust the e
18. om Google Play     Therm App and the Android device are connected properly via a USB OTG cable     Verify that your cable is OTG compatible   Plug the USB OTG cable into the Android device USB port     Verify that the USB connector connected message appears on top of the screen  Replace the  cable if this message does not appear     Table  1  Troubleshooting List    Problem   Indication Solution  System Failure  Application does App is not initiated after Ensure that USB OTG cable is properly connected between  not start  connecting to Therm App    the Android device and Therm App device   Try using a different cable  from the 3 supplied   Ensure that the Therm App Basic app is installed from  Google Play   Try installing the app ona different device to find if this is  an Androidd Device or Therm App device problem   On some rare cases thre might be compatibility issues  between the Android device and the Therm App device   Application shuts Application shuts itself Ensure that USB OTG cable is properly connected between  off  off  the Android device and Therm App device   Verify that you are using a USB OTG cable     3 Repeated Each startup Therm App From the Apps menu  select My files  gt  all files  gt   initialization performs the initialization   Thermapp   process  Delete folder with a serial number tag   Uninstall and re install Therm App Basic application   Plug the Therm App device again   4 Battery saver Android device switches Select the Disable screen timeout che
19. s  a Settings    Night Vision Color     inverts Black and White on Night Vision mode        l Imaging Mode Thermography  Thermography Color     enables selecting thermography color palettes   Temperature Measure     in Thermography  selecting Center activates  readings of temperature measured at the center of the image  at the  cross hair mark   Thermography Color Rainbow  E Thermography Settings     enables choosing temperature units  Temperature Measure Ciar  emissivity  reflected temperature  and scale truncation level   m General Settings     choose adding audio to videos  watermark Thermography Settings  settings  disabling screen timeout  and adding annotations to raw data  options  General Settings    Export     allows for defining which files  such as IR Photo  Color  Export Save Options    Photo  Screenshots  and more  are created and shared when using  Therm App TH  Here you ll also be able to link Therm App TH to your  DropBox account for auto upload     Maintenance     performs bad pixel repair  Help  Help   Therm App Support     link to Therm App support web page   About     general application and device version information     Maintenance    About     lt  O L    Tap the Back button to exit the Settings screen and return to  the Camera View screen    Document  UM TAH68AQ 1100_ A Page 14 of 23    Application Operation Therm App Operation Manual    Imaging Mode    The Therm App device image can be displayed in one of two modes  Night Vision  To change the imaging 
20. t may impact the  measurement results      Therm App manuals are updated from time to time  and product critical notifications are  published occasionally  To access the latest manuals and notifications  go to http   www therm   app com   Therm App is a Class B digital product     This product has been tested and found to comply with the limits for a class B digital product   pursuant to Part 15 of the U S  FCC Rules     Some parts of Therm App have sharp edges and could cause injury   Read this document in full  as well as the warranty document provided with the product     Do not drop Therm App or apply pressure on the IR lens to avoid breaking the lens  If the IR  lens breaks  do not touch the broken pieces  Touching the broken lens pieces can cause injury       Do not point the infrared detector  with or without the lens and lens cover  at intensive energy  sources  for example products that emit laser radiation  or the sun  This could damage the  detector      Do not use Therm App in a temperature environment higher than  50 degrees Celsius   122  degrees Fahrenheit   unless specified otherwise in user documentation or technical data  High  temperatures can cause damage to the detector      The Therm App device is not sealed  Do not expose the Therm App device to water  rain or  dust     Do not apply solvents or similar liquids to the detector or the lens     The lens has a delicate anti reflective coating  Clean the lens using a soft cloth applying very  light pressure 
    