1. short hold more than 4 seconds PCB failure Replace the PCB call for service Power cord lose Replug the power cord AC fuse burn out Replace the AC fuse UPS always at battery mode Line voltage too high too low 1 iti ot black out normal condition PCB failure Replace the PCB call for service Buzzer continuous beeping Overload Remove the noncritical loads UPS does not provide expected Battery is weak due to wear or Allow UPS to recharge battery for run time Low battery warning successive mains outages a minimum of 8 hours If UPS is sounded prematurely sounds low battery warning prematurely when retested battery should be replaced Specifications are subject to change without prior notice YW A gt an a Y USER S MANUAL UPS 1200D Introduction SUP 1200D can instantly switches your computer to emergency battery backup power and allows you to work through brief power outages without data loss or downtime It continuo usly conditions the power coming into your computer and providing power supply for virtually zero interruption This state of the art UPS is specially designed for PC users and also suitable for computer peripherals or POS Besides its space saving compact size this UPS also impress you with its elegant appearance The attractive LCD display enables you to check the UPS working status at any time A microprocessor is used as the controller that re
2. Specification Characteristic Specification Rated Power 1200VA Backup Power 720W Input 165V 275V AVR Range 175V 265V Output 220V 10 Frequency 50Hz 60Hz Type Sealed maintenance free lead acid Battery Capacity 12V 7Ah 2 PCs Back up time half load Over 8 Minutes Typical Recharge Time 8 hour LCD indicators Status NORMAL FAULT BATTERY CHARGE OVERLOAD Battery Mode Beeping sound every four seconds every Audible Alarm second if approaches final discharge Overload Continuous beeping sound Operating Environment Temperature 3C 40C Humidity 10 90 RH non condensing Audible Noise lt 45dBA Transfer time lt 10ms Net weight 12 00 Kg Dimension WxDxH 120x300x190 mm Maintenance 1 With normal use a UPS battery will last three to six years depend on number of discharge and temperature Replacement and servicing of the battery should be performed or supervised by personnel knowledgeable of batteries and their precautions Keep unauthorized persons away 2 Charge the UPS s battery every 3 months during extended storage 3 Disconnect the power during extended storage to avoid overcharge of the battery 4 Avoid overload or short circuit thought the UPS have build in overload and short circuit protect function Troubleshooting Problem Possible Cause Action To Take POWER button not pushed or Press the POWER button and UPS not on LCD not light push too
3. nders the product an intelligent UPS capable of self protection and fault diagnosis Build in AVR function autom atically adjusts itself to maintain a power supply of stable voltage when the utility power is of extra high or low voltage High performance surge suppression protects your computer from electrical noise and damaging power surges Performance Uninterruptible Power Protects your data by supplying battery backup when power fails Microprocessor Control By means of innovative software control programs the complicated hardware circuitry is inlaid in the powerful microprocessor Apart from reduced size it also lowers the defective rate of UPS LCD Display and Audible Alarms Actively let you know if the unit is on battery if the battery is low or if there is an overload condition High quality battery The selection of high quality sealed lead acid maintenance free battery maximizes the life span of the battery for enhanced economic benefits Automatic Detection When the UPS is powered on it immediately performs an inspection of the battery capacity Automatic Voltage Regulation Corrects over and under voltages without draining the battery This preserves battery resources and ensures your UPS will provide the optimum runtime during a complete blackout Surge Protection Shields hardware from damage Automatic Charge The UPS charges its battery whenever it is connected to utility power Protection for Tel Fax Modem Connecti
4. on Protect the Tel Fax Modem from lightning and spike disturb Installation Inspection Inspect the UPS upon receipt The packaging is recyclable Save it for reuse or dispose of it properly Placement Install the UPS in a protected area with adequate airflow and away from direct sunlight and excessive dust Do not operate the UPS where the temperature and humidity is outside the specified limits in the Specifications Table Connect to Utility Connect the AC input power connector to utility power to power up the UPS Charge the battery The battery in the UPS will lose some charge in shipping and storage It will recharge completely after approximately 8 hours of normal operation Do not except full battery run time during this initial recharge period Connect the loads Plug the loads into the output connectors on the rear of the UPS Caution Never connect a laser printer or plotter to the UPS with other computer equipment A laser printer or plotter periodically draws significantly more power than when idle and may overload the UPS Presentation Front Panel Rear Panel D lt 2 L Ox O D ON JE ha Ss Pa D D D Normal Utility power in normal condition Fault Utility power unusual or other problem occur Overload UPS overload The buzzer emits continuous alarm for 30 seconds Charge Battery charge mode Battery UPS transfe
5. r to backup or battery test mode The buzzer emits alarm every four seconds Load Capacity indicator Battery Capacity indicator Power switch Power on off Battery test and buzzer on off Output socket Connect with load equipment Input socket Connect with utility power Fuse set Built in fuse avoid damaged by short circuit or overload Communication interface port Connect to the computer with the communication cable Optional Input phone jack Insert the phone line into the jack optional Output phone jack Connect to the Tel Fax Modem by another phone line optional Switch On With the UPS plugged in press and hold the POWER button more than 4 seconds until hearing one beep sound to switch the UPS on The UPS will perform self testing each time when it is switched on Switch Off By pressing and hold the POWER button more than 4 seconds until hearing one beep sound Self Test In normal utility power push the POWER button less than 1 second and UPS performs a self test on the battery capacity During the self test the UPS operates a back up mode the BATTERY and FAULT icon stay on Silence In Back up mode push the POWER button less than 1 second to silence the audible alarm Back Up slow alarm When in Back Up mode the BATTERY and FAULT icon illuminates and the UPS emit beeping sound every four seconds The alarms stops when the UPS return to the utility power operation Press the POWER bu
6. tton to stop the beeping Low Battery rapid alarm In Back Up mode when the battery energy runs low the UPS beeps rapidly until the UPS shuts down from battery exhaustion or return to utility power operation Overload continuous alarm When the UPS is overloaded the OVERLOAD icon illuminates and the UPS emits continuous alarm for 30 seconds to warn an overload condition Disconnect nonessential load equipment from UPS to eliminate the overload
Download Pdf Manuals
Related Search
ManualDOWNLOAD manual download windows update manual download windows 11 manual download kb5062553 manual download nvidia drivers manual download kb5034441 manual download page manual download kb5055523 manual download genshin impact manual download kb5062660 manual download windows 11 version 24h2 manual download windows 11 update manual download windows 11 24h2 manual download windows 10 update java manual download msbte manual download chrome manual download first aid manual pdf free download sda church manual 2024 pdf download manual download