Home

Owner`s Manual - Mustang Survival

image

Contents

1. MD3085 MD3087 5 Inflatable PFD Owner s Manual 2 Automatic Backup Inflation MD3087 Inflation will occur automatically within 10 seconds after the inflator is immersed in water The water sensing bobbin will disintegrate triggering a spring loaded plunger which punctures the CO gt cylinder Figs 8 and 10 to inflate the Inflatable PFD Information When inflated the carbon dioxide CO gas used to inflate the PFD will slowly escape through the fabric over time A slight reduction of pressure will be observed after several hours of inflation Topping up by oral inflation may be required in the event of very prolonged immersion IMPORTANT See Special Considerations for Automatic Devices Oral Inflation Properly armed and inspected Inflatable PFDs will inflate when manually or automatically activated However you can fully inflate the Inflatable PFD by mouth Fig 4 should inflation not occur or if you are in a non emergency situation To orally inflate the Inflatable PFD first locate the oral inflation tube by opening the wearer s left front panel of the Inflatable PFD Remove the dust cap from the end of the oral tube and blow into the tube until the Inflatable PFD is fully inflated Place the oral inflator dust cap back in the stowed position Fig 6 WARNING Avoid double inflation CO cylinder inflation after full oral inflation as it could damage the PFD FIGURE 4
2. nflatable PFD Owner s Manual 6 Special Considerations for Automatic Devices MD3087 The Inflatable PFD might not be armed when needed either knowingly or unknowingly Premature automatic inflation causes several risks that you must address to avoid drowning Much less common but also important are WARNING Avoid double inflation CO cylinder inflation after full oral inflation as it could damage the PFD Inflation when stored in a tight space could damage the PFD and The PFD could inflate when you are in an awkward place or position Premature inflation may occur in certain conditions including when the device is subjected to heavy splashing high humidity heavy fog and heavy rain Care and attention should be taken to ensure that when the device is used in these types of conditions auto inflation does not occur prematurely If this PFD should inflate prematurely a re arm kit MA7202 is required to re arm the device IMPORTANT The Inflatable PFD should be re armed according to the instructions Re arming Your PFD MD3087 p 10 Deflating the Inflatable PFD 1 To deflate the Inflatable PFD reverse the oral inflation tube dust cap and insert it into the valve or depress valve with fingertip The dust cap will not lock in the deflate position so it is necessary to hold it in place Fig 5 Gently squeeze the Inflatable PFD until all air or gas has been expelled To avoid damage do not wrin
3. Owner s Manual MD3085 Inflatable PFD Manual Inflation Model Recreational USCG Approved Type III Uninspected Commercial Vessels USCG Approved Type V MD3087 Inflatable PFD Manual with Automatic Backup Inflation Model Recreational USCG Approved Type II Uninspected Commercial Vessels USCG Approved Type V DO NOT REMOVE PRIOR TO SALE CONTENTS Page 1 Approval Conditions and Carriage Regulations 1 Note to Uninspected Commercial Vessel Operators 2 Why are PFDs Required Safety Equipment 2 What is an Inflatable PFD 2 Instructions for Use 3 Uninspected Commercial Vessel Use 3 Component Inspection Instructions 4 Readiness Checklist 4 Sizing and Fit 4 Donning Instructions 5 Inflating Your Inflatable PFD 7 Special Considerations for Automatic Devices MD3087 7 Deflating the Inflatable PFD 8 Usage Below Freezing 8 Re arming Your PFD MD3085 10 Re arming Your PFD MD3087 13 Repacking 14 Is Your PFD in Good and Servicable Condition 14 Care and Maintenance Instructions 16 Cleaning and Storing of Your Inflatable PFD IMD3085 17 Cleaning and Storing of Your Inflatable PFD IMD3087 17 How and Why to Test Your PFD 18 Model MD3087 18 How Do You Test Your PFD Using the Automatic Inflator MD3087 19 How Do You Test Your PFD Using the Manual Inflator 19 How Do You Test Your PFD Using the Oral Inflator 20 Wear Your PFD 20 Hypothermia 22 Each of These Devices is Intended to Help You Save Your Own Life 22 Inflatable PFD
4. To avoid accidental inflation don t allow the water to contact the inflator MD3087 iii Perform a thorough visual examination See Readiness Checklist p 4 Perform these tests more often if exposed to potential damage or used in extreme conditions After Each Inflation Re arm the Inflatable PFD See Re arming Your PFD your model p 8 or 10 Annually Perform the following at the beginning of each boating Inflatable PFD Owner s Manual season after inflation or whenever the integrity of the Inflatable PFD is in doubt i Check all components for dirt or corrosion Clean or replace as neccessary See Readiness Checklist p 4 ii Visually examine your Inflatable PFD for damage or excessive abrasion wear tear or contamination Particular attention must be paid to the stitching straps and hardware If in doubt send it to your Mustang dealer for evaluation and or servicing iii Perform the Oral Inflation Valve Test See the Oral Inflation Valve Test in the Every Two 2 Months Care and Maintenance Instructions section iv Perform the Leak Test See the Leak Test in the Every Two 2 Months Care and Maintenance Instructions section v For the MD3087 only Ensure the current date is not three 3 years past the date on the bobbin If it is re arm the inflator see Re arming Your PFD MD3087 p 10 vi Ensure the service indicator is green Fig 1 vii Record as an Annual inspection in permanent ink
5. owner s manual See Care and Maintenance Instructions p 14 for servicing information 3 The operator of an uninspected commercial vessel is responsible for providing each person onboard with the safety information required for use of the Inflatable PFD See page 1 for information NOTE TO UNINSPECTED COMMERCIAL VESSEL OPERATORS The operator of the vessel is required to provide the following user information to each person on board Inflatable PFDs will not provide any buoyancy without being inflated Follow these instructions to be sure your PFD is armed and donned 1 Inflatable PFD Owner s Manual correctly and that you understand how to inflate the device Basic visual inspection for readiness see p 3 Inflation system status check see p 4 Donning see p 4 Inflation see p 5 WHY ARE PFDS REQUIRED SAFETY EQUIPMENT Drownings are the leading cause of fatalities involving recreational boating A PFD provides flotation to help keep your head above water help you to stay face up in the water and increase your chances for survival and rescue Most adults only need an extra 7 to 12 Ib 3 2 to 5 5 kg of flotation to keep their heads above water The proper size PFD will properly support the weight of the wearer Since this Inflatable PFD does not have inherent buoyancy it provides flotation only when inflated Familiarize yourself with the use of this Inflatable PFD so you know what to do in an emergency WHAT IS AN INF
6. the o ring is in place and the sensor ring is attached Fig 10 Ensure that the CO cylinder has not been pierced Fig 10 Inflatable PFD Owner s Manual FIGURE 7 MD3085 Manual Inflator Cylinder Step 2 Sensor Ring Step 3 Bayonet Tab Step 4 O Ring Step 3 Lever Service Step 4 Indicator Step 5 Service Indicator If green unit is operable STOP If red stop and service unit 4 Raise and hold the lever into the inflator housing Install a new cylinder bayonet assembly by engaging bayonet tabs in housing pushing in then turning clockwise 1 8 turn to a full stop Fig 8 WARNING PFD WILL ONLY INFLATE IF CYLINDER IS TURNED TO A FULL STOP 9 Inflatable PFD Owner s Manual FIGURE 8 MD3085 Manual Inflator Tab S E s Piercing Pin t amp u Lever 5 Examine the service indicator Fig 8 and ensure it is GREEN If the service indicator is red the mechanism has been fired or is incorrectly fitted and the inflator requires service See Re arming Your PFD MD3085 p 8 NOTE The service indicator must be green before proceeding 6 Refold the Inflatable PFD in accordance with the Repacking section p 13 YOUR INFLATABLE PFD MD3085 IS NOW READY FOR MANUAL USE Re arming Your PFD MD3087 NOTE A re arm kit MA7202 with a valid bobbin install by date check re arm kit packaging is required for this procedure IMPORTANT Follow instr
7. LATABLE PFD While traditional PFDs are inherently buoyant inflatable PFDs rely entirely on inflation for buoyancy Uninflated the Inflatable PFD is a comfortable slim collar that can be inflated at any time with a 33 gram CO3 gas cylinder The Inflatable PFD is designed to offer maximum mobility with minimum bulk The Inflatable PFD MD3085 can be inflated either manually by jerking a pull tab or orally by mouth The Inflatable PFD MD3087 can be inflated either automatically during water immersion manually by jerking a pull tab or orally by mouth It is recommended that you familiarize yourself with the procedures outlined in INSTRUCTIONS FOR USE p 2 INSTRUCTIONS FOR USE This manual supplies instructional maintenance and safety information for all models MD3085 and MD3087 unless specified otherwise The model number is listed on the underside label Inflatable PFD Owner s Manual 2 Congratulations on your Inflatable PFD purchase Uninspected Commercial Vessel Use This Inflatable PFD is not approved for hot work and care must be taken to avoid damage from abrasion and sharp objects Component Inspection Instructions 1 Examine the service indicator through the window panel Fig 1 Ensure the service indicator is green If the service indicator is red the mechanism has been fired or is incorrectly fitted see Re arming Your PFD for your model NOTE The service indicator must be green before proceedin
8. Safety Accessories 23 Additional Information Inflatable PFD Owner s Manual i APPROVAL CONDITIONS AND CARRIAGE REQUIREMENTS Recreational This Inflatable PFD is approved by the U S Coast Guard USCG for use as a Type III Model MD3085 Type II Model MD3087 Personal Flotation Device PFD They are not approved for water skiing or other high impact high speed activities This Inflatable PFD was designed to be more comfortable and less restrictive to wear than inherently buoyant PFDs When worn used and serviced according to this owner s manual this Inflatable PFD can greatly increase your chances of survival in the water Not recommended for non swimmers or weak swimmers Users of inflatable PFDs must be at least 16 years old Commercial Models MD3085 and MD3087 are U S Coast Guard approved Type V inflatable PFDs approved ONLY WHEN WORN for use on uninspected commercial vessels less than 40 feet in length not carrying passengers for hire as a substitute for a Type Ill PFD MD3085 Type II PFD MD3087 when used in accordance with this owner s manual Conditions for Type V Approval in commercial applications 1 The Inflatable PFD must be worn before getting underway and whenever above deck and not within an enclosed space to meet the carriage requirement 2 The operator of an uninspected commercial vessel is responsible for servicing and maintaining the Inflatable PFD in good serviceable condition in accordance with this
9. amine the service indicator Fig 9 and ensure it is GREEN If the service indicator is red the mechanism has been fired or is incorrectly fitted and the inflator requires service See Inflatable PFD Owner s Manual 12 Re arming Your PFD MD3087 p 10 NOTE The service indicator must be green before proceeding 12 Refold the Inflatable PFD in accordance with the Repacking section p 13 YOUR INFLATABLE PFD MD3087 IS NOW READY FOR MANUAL USE WITH AUTOMATIC BACKUP FIGURE 11 MD3087 Automatic Inflator Wa T Tab Cylinder Piercing Pin Service Indicator 1 8 Turn Groove Pull cord Repacking Gently squeeze the Inflatable PFD until all air or gas has been expelled Fig 5 Do not wring or twist the Inflatable PFD Put the inflation tube dust cap back in its stowed position on the oral inflation tube Fig 6 NOTE Before following the repacking sequence be sure to properly re arm your Inflatable PFD 1 Fold side A inward along the full length of the dotted line Fig 13 2 Fold lapel B inward along dotted lines Fasten along the full length of the Velcro Ensure that the Inflatable PFD is tucked under the Velcro strip 3 Repeat steps 1 and 2 with side C and lapel D Your Inflatable PFD will look as illustrated in Fig 14 4 Fold down the collar E along the dotted line Fig 14 5 Fold the cover F up over the collar and fasten with 3 V
10. anual 14 for instructions Failure to follow these instructions rigorously could result in a non functioning PFD causing injury or death Check the following at the intervals listed below 1 3 4 15 Before Each Use i Examine the service indicator through the window panel ensuring it is green If the indicator is red the mechanism requires service See Re arming Your PFD your model p 8 or 10 ii Ensure the manual pull tab is accessible iii Visually examine your Inflatable PFD for damage or excessive abrasion wear tear or contamination Particular attention must be paid to the stitching straps and hardware If in doubt send it to your Mustang dealer for evaluation and or servicing Every Two 2 Months i Leak Test The Inflatable PFD should be tested for general leakage by orally inflating your Inflatable PFD until firm and let stand for 16 hours A leaking Inflatable PFD will not hold its firmness and should be replaced If your Inflatable PFD leaks take it to your Mustang dealer for evaluation and or servicing Repack the Inflatable PFD as outlined in the Repacking section p 13 ii Oral Inflation Valve Test To check the oral inflation valve fully inflate the Inflatable PFD using the oral inflator and hold valve under water If bubbles appear deflate and re inflate to test again Should the leak persist take your Inflatable PFD to your Mustang dealer for evaluation and or servicing CAUTION
11. ater Exhaustion or Expected Temperature C F Unconsciousness Time of Survival 0 3 32 5 Under 15 min Under 15 45 min 0 3 4 32 5 40 15 30 min 30 90 min 4 10 40 50 30 60 min 1 3 hrs 10 16 50 60 1 2 hrs 1 6 hrs 16 21 60 70 2 7 hrs 2 40 hrs 21 27 70 80 2 12 hrs 3 hrs to Indefinite over 27 over 80 Indefinite Indefinite PFDs can increase survival time because they allow you to float without using energy treading water and because of their insulating properties Naturally the warmer the water the less insulation you will require When operating in cold waters below 60 F 15 6 C you should consider using a coat or jacket style PFD or a Type V Thermal Protective PFD as they cover more of the body than the vest or belt style PFDs Some Points to Remember About Hypothermia Protection 1 Always wear your Inflatable PFD Even if you become incapacitated due to hypothermia the Inflatable PFD will keep you afloat and greatly improve your chances of rescue 2 Do not attempt to swim unless it is to reach a nearby craft fellow survivor or a floating object on which you can lean or climb Swimming increases the rate of body heat loss In cold water drown proofing methods that require putting your head in the water are not recommended Keep your head out of the water This will greatly lessen heat loss and increase your survival time 3 Use the standard H E L P position when wearing an Inflatable PFD drawing the leg
12. e Please refer to the governing body s documentation found online at http hazmat dot gov 23 Inflatable PFD Owner s Manual WE SAVE LIVES FOR A LIVING www mustangsurvival com TOLL FREE 1 800 526 0532 EMAIL custserv mustangsurvival com Mustang Survival and seahorse design is a registered trademark of Mustang Survival Corp Our commitment to quality has earned our Burnaby facilities ISO 9001 registration the highest of all international standards This is our guarantee you re receiving the ultimate in design and manufacturing HT1126 Rev 10Aug2011
13. elcro tabs Fig 14 inset 6 Ensure the pull tab is on the outside of the folded Inflatable PFD Fig 13 Inflatable PFD Owner s Manual 15 depicts a correctly folded Inflatable PFD NOTE Ensure that all Velcro strips and tabs are fastened FIGURE 13 s FIGURE 15 IS YOUR PFD IN GOOD AND SERVICEABLE CONDITION Check your Inflatable PFD between outings to be sure that it is properly armed that it is free of rips tears or holes that all seams are securely sewn and that the fabric straps and hardware are still strong See Readiness Checklist p 4 Inspect the inflatable portion of the Inflatable PFD in accordance with the CARE AND MAINTENANCE INSTRUCTIONS CARE AND MAINTENANCE INSTRUCTIONS Federal Regulations require Coast Guard approved personal flotation devices PFDs that are legibly marked with the Coast Guard approval number are in good and serviceable condition and are the correct size for each person on board It is the responsibility of the operator to be sure this PFD is in serviceable condition To be considered serviceable this PFD shall not exhibit deterioration that could diminish its performance such as broken or deformed hardware detached webbing rotted structural components air leaks or nonfunctional inflators Unless worn inflated this PFD must also be properly armed with a cylinder installed in the inflator and service indicator showing green See Page 2 Inflatable PFD Owner s M
14. g 2 Undo the Velcro strips along both sides of the PFD FIGURE 1 Manual Inflator MD3087 Service Indicator 3 Ensure the oral inflation dust cap is in the stowed position Fig 6 4 Ensure the service indicator is green and the pull tab lanyard is 3 Inflatable PFD Owner s Manual hanging on the outside Fig 1 secure the Velcro strips on both sides of the Inflatable PFD 5 For the MD3087 only Ensure the bobbin is valid The PFD or bobbin must have been purchased within the last three 3 years If the purchase date is unknown check the date printed on the bobbin and replace if older than three 3 years see Re arming Your PFD MD3087 p 10 Readiness Checklist Check your Inflatable PFD and ensure all of the checkpoints listed below are true before use Service indicator is green Fig 1 No rips tears or holes all seams are securely sewn and the fabric straps and hardware are still strong All Velcro and waist belt are securely fastened Inflatable PFD is not twisted Oral inflation dust cap is in the stowed position Fig 6 For the MD3087 only Ensure the bobbin is valid The PFD or bobbin must have been purchased within the last three 3 years If the purchase date is unknown check the date printed on the bobbin and replace if older than three 3 years see Re arming Your PFD MD3087 p 10 Your Inflatable PFD is ready for
15. g or twist the Inflatable PFD Put the inflation tube dust cap back in its stowed position on the oral inflation tube Fig 6 Examine the service indicator Fig 1 If the service indicator is red the mechanism has been fired or is incorrectly fitted and the inflator requires service see Re arming your PFD for your model Inflatable PFD Owner s Manual NOTE The service indicator must be green before proceeding 4 Your device is ready to be repacked see Repacking p 13 FIGURE 5 FIGURE 6 Oral Inflator Beh k Dust cap Dust cap BS in stowed position for position deflation Usage Below Freezing When the temperature is below freezing the Inflatable PFD should be worn partially inflated because a fully discharged cylinder may not quickly or adequately inflate your Inflatable PFD Under these conditions use the oral inflator to adequately top up the PFD after CO3 inflation WARNING CO inflation could over pressurize and damage your Inflatable PFD if already fully inflated Re arming Your PFD MD3085 NOTE A re arm kit MA7203 is required for this procedure IMPORTANT Follow instructions in the exact sequence below 1 Unpack or open the Inflatable PFD so that the manual inflator is exposed Fig 7 2 Remove the cylinder bayonet assembly by rotating counterclockwise and then pull out Discard the used cylinder bayonet assembly 3 Check the new cylinder bayonet assembly to ensure
16. g properly and reduce the likelihood of premature inflation and its associated dangers HOW DO YOU TEST YOUR PFD USING THE AUTOMATIC INFLATOR MD3087 1 To test your Inflatable PFD you will need your fully armed Inflatable PFD and re arming kit MA7202 approved for your Inflatable PFD 2 Put on the Inflatable PFD 3 Get into shallow water just deep enough that you can stand with your head above the surface Once the inflator is underwater the Inflatable PFD should fully inflate automatically within 10 seconds 4 See if the Inflatable PFD will float you on your back or just slightly back of vertical In a relaxed floating position verify that your mouth is well above the water s surface Note the effect of where you hold your legs on how you float 5 Get out of the water and remove the Inflatable PFD Remove the used CO3 cylinder bayonet assembly and the used bobbin from the Inflatable PFD inflator Deflate the Inflatable PFD by depressing the oral inflator valve see Deflating the Inflatable PFD p 7 6 Let the Inflatable PFD dry thoroughly Re arm and Repack the PFD p 13 Inflatable PFD Owner s Manual 18 HOW DO YOU TEST YOUR PFD USING THE MANUAL INFLATOR 7 To test your Inflatable PFD you will need your fully armed Inflatable PFD and re arming kit approved for your Inflatable PFD MA7203 for model MD3085 MA7202 for model MD3087 Put on the Inflatable PFD Actuate the inflation system by jerking firml
17. heat Inflatable PFD Safety Accessories For the MD3085 MA7203 Re arm Kit Contains 33 gram replacement CO3 cylinder bayonet assembly for the manual inflator Inflatable PFD Owner s Manual 22 For the MD3087 MA7202 Re arm Kit Contains 33 gram replacement CO3 cylinder bayonet assembly and bobbin for the auto inflator ADDITIONAL INFORMATION If you need more information about PFDs and safe recreational boating contact your state boating authority U S Coast Guard Auxiliary U S Power Squadron Red Cross or your nearest unit of the U S Coast Guard or call the free boating course number1 800 336 BOAT in VA call 800 245 BOAT DO NOT ATTACH PFD S TO YOUR BOAT Each PFD has straps hooks buckles or other means for securing the device in place on the wearer Some PFDs also incorporate decorative d rings or tabs Such items are not to be used to attach the device to the boat Attaching the device to the boat will not permit it to perform as intended AIRLINE OPERATOR POLICY ON CARRIAGE OF INFLATABLE PFDS AND CO CARTRIDGES Please be aware that the following regulations apply to the air transport of this product According to U S Research and Special Programs Administration Regulations Title 49 CFR 75 10 a 25 With the approval of the aircraft operator one small carbon dioxide cylinder fitted into a self inflating jacket plus one spare cartridge may be carried by a passenger or crew in checked or carry on baggag
18. lete inflation without touching bottom Note this level of inflation because it is the minimum needed for you to safely use this Inflatable PFD 6 Fully inflate the Inflatable PFD using the oral inflator 7 See if the Inflatable PFD will float you on your back or just slightly back of vertical In a relaxed floating position verify that your mouth is well above the water s surface Note the effect of where you hold your legs on how you float 8 Get out of the water and remove the Inflatable PFD Completely deflate the Inflatable PFD using the oral inflator 9 Let the Inflatable PFD dry thoroughly Re arm for your model and Repack the PFD p 13 WEAR YOUR PFD In approximately 80 percent of all boating fatalities the victims were not wearing a PFD Most fatal accidents happen on calm sunny days This Inflatable PFD is much more comfortable to wear than other PFD types Get into the habit of wearing this Inflatable PFD Non swimmers and children especially should wear a hybrid or non Inflatable PFD at all times when on or near the water HYPOTHERMIA Prolonged exposure to cold water causes a condition known as hypothermia a substantial loss of body heat which leads to exhaustion and unconsciousness Most drowning victims first suffer from hypothermia The following chart shows the effects of hypothermia how hypothermia affects most adults Inflatable PFD Owner s Manual 20 How hypothermia affects most adults W
19. obbin If the bobbin has been fired or damaged replace it Ensure the new bobbin is valid it must have been purchased within the last three 3 years If the bobbin purchase date is unknown check the date printed on the bobbin and replace if older than three 3 years see Re arming Your PFD MD3087 p 10 7 IMPORTANT Bobbin yellow must be installed into the HOUSING see figure 9 white side up aligning the slots on the bobbin with the ridges inside the threaded housing The bobbin will slide in easily if installed correctly 8 Install cap by screwing clockwise until it meets the housing shoulder 9 Check the new cylinder bayonet assembly to ensure the o ring is in place and the sensor ring is attached Fig 9 Ensure that the CO gt cylinder has not been pierced Fig 10 FIGURE 10 Solid Pierced sto Caution Do not use Cylinder Cylinder the cylinder bayonet Top Top assembly if either Attached Broken me ae k Peta Sensor Sensor ring ees Ring Ring missing or damaged IMPORTANT You will damage the sensor ring if bobbin and cap are not installed first 10 Push and hold the lever into the inflator housing The pull cord should be situated in the groove Fig 11 Install a new cylinder bayonet assembly by engaging bayonet tabs in housing pushing in then turning clockwise 1 8 turn to a full stop Fig 11 WARNING PFD WILL ONLY INFLATE IF CYLINDER IS TURNED TO A FULL STOP 11 Ex
20. on the Care and Storage label in the Date Maintained column Repack the Inflatable PFD as outlined in the Repacking section p 13 WARNING If you are not confident in the self inspection and servicing of your Inflatable PFD in accordance with these instructions take your Inflatable PFD to a Mustang dealer for professional servicing or contact Mustang Survival see contact information on back of manual Cleaning and Storing of Your Inflatable PFD IMD3085 To clean your Inflatable PFD remove the CO3 cylinder bayonet assembly Hand wash or sponge down the Inflatable PFD including inflator in warm soapy water and rinse with clean water Hang to dry on a plastic coat hanger Be sure to replace CO3 cylinder bayonet assembly See Re arming your PFD MD3085 p 8 Always store your Inflatable PFD in a warm dry place out of direct Inflatable PFD Owner s Manual 16 sunlight Cleaning and Storing of Your Inflatable PFD IMD3087 To clean your Inflatable PFD remove the CO3 cylinder bayonet assembly cap and bobbin Keep the bobbin dry Hand wash or sponge down the Inflatable PFD in warm soapy water Rinse the PFD and inflator with clean water Hang the Inflatable PFD to dry on a plastic coat hanger Ensure the inflator is thoroughly dry before installing the bobbin Be sure to replace CO3 cylinder bayonet assembly cap and bobbin see Re arming your PFD MD3087 p 10 Always store your Inflatable PFD in a warm dry
21. place out of direct sunlight HOW AND WHY TO TEST YOUR PFD Inflate your Inflatable PFD and try it out in the water to Make sure it floats you e Comfortably when worn properly e Adequately for expected wave conditions body shapes densities affect performance Make sure it works e A flow of bubbles should not appear see CARE AND MAINTENANCE INSTRUCTIONS for leak tests p 14 It should inflate quick and easily Learn how it works by e Activating the CO3 inflation system e Re arming the CO inflation system e Using the oral inflator tube To check the manual inflation system with CO3 cylinder bayonet assembly removed determine that the CO3 cylinder piercing pin moves freely when pushing up on the lever arm by pushing down on the pins and releasing the pins followed by the lever arm for MD3085 see Fig 8 and for MD3087 see Fig 11 Repeat this several times to check the manual inflation system 17 Inflatable PFD Owner s Manual MODEL MD3087 The U S Coast Guard recommends that you purchase two automatic re arming kits MA7202 One kit is to be used immediately in testing the automatic inflation system see HOW DO YOU TEST YOUR PFD USING THE AUTOMATIC INFLATOR p 18 and the other to carry on board as a spare The U S Coast Guard recommends you test the automatic inflation system in the water at the beginning of each boating season By doing this you demonstrate that the automatic inflation system is still workin
22. s up to a seated position because doing so will help you conserve body heat Fig 16 4 Keep a positive attitude about your survival and rescue This will improve your chances of extending your survival time until rescued Your will to live does make a difference 5 If there is more than one person in the water huddling is recommended while waiting to be rescued This action tends to reduce the rate of heat loss and thus increase the survival time 21 Inflatable PFD Owner s Manual FIGURE 16 HELP Position EACH OF THESE DEVICES IS INTENDED TO HELP YOU SAVE YOUR OWN LIFE For your Inflatable PFD to function properly follow these suggestions to verify that it fits floats and remains in good condition Check the inflation mechanism status indicators before each use Get in the habit of re arming the inflation mechanism right after each inflation Try your wearable Inflatable PFD on and adjust it until it fits comfortably in and out of the water Mark your Inflatable PFD with your name if you are the only wearer Do not alter your Inflatable PFD If it doesn t fit properly get one that does An altered device is no longer Coast Guard approved Your Inflatable PFD is not intended for use as a fender or kneeling pad If your Inflatable PFD is wet allow it to dry thoroughly before storing it Store it in a well ventilated area Do not dry your Inflatable PFD in front of a radiator or other source of direct
23. uctions in the exact sequence below 1 Unpack or open the Inflatable PFD so that the manual automatic inflator is exposed Fig 9 2 Remove the cylinder bayonet assembly by rotating counter clockwise and then pull out Discard the used cylinder bayonet assembly NOTE You will damage the sensor ring if bobbin and cap are not installed first 3 Remove cap by turning counter clockwise Fig 9 4 Remove bobbin from cap or housing unit Discard bobbin NOTE The yellow bobbin may remain in the housing or in the cap assembly when you remove the cap The bobbin must be Inflatable PFD Owner s Manual 10 removed prior to re arming FIGURE 9 MD3087 Automatic Inflator Cap CO F Step3 Cylinder Step 2 Cylinder e o Bayonet Sensor Ring Assembly Step 9 i Yellow Bobbin LS white side up Bayonet V mie Step 4 Tab aN HOUSING Step 10 a Step 4 O ring l Step 9 Ji Housing Pins i Shoulder Step 8 gt C Service ZJ Indicator ae aa Lever ep Step 10 Pull Tab Service Indicator If green unitis operable STOP If red stop and service unit 5 Check the housing to be sure it is clear and dry If necessary rinse the inflator with fresh water to remove dirt and salt Let dry before going to step 6 11 Inflatable PFD Owner s Manual 6 Inspect the b
24. use if all applicable boxes are checked NOTE Contact your Mustang Dealer if you have any concerns about the readiness of your Inflatable PFD Sizing and Fit This PFD provides a minimum of 33 7 lbs of buoyancy when inflated and is designed for wearers over 16 years of age with a chest range of 30 52 inches 76 132 cm weighing over 80 pounds 36 kg Donning Instructions It is important that the Inflatable PFD is properly adjusted to fit the person wearing it An incorrect fit or improper fastening of attachments could impede its effectiveness Inflatable PFD Owner s Manual 4 1 All belts and straps are already threaded correctly and only need to be adjusted for fit The belt should fit below your rib cage adjusted to a tight personal fit 2 Put the Inflatable PFD on just like a jacket Fig 2 and fasten the front buckle Adjust the waist belt using the side buckle on the belt and secure the belt s loose end in the belt loop WARNING Do not wear Inflatable PFDs under clothing as the inflation could be restricted or you could be injured FIGURE 2 Inflating Your Inflatable PFD It is recommended that the following procedures be followed to inflate your Inflatable PFD 1 Manual Inflation Activate the inflation system by jerking firmly downward on the pull tab Fig 3 The Inflatable PFD should fully inflate within 5 seconds FIGURE 3 Manual Inflator Automatic Inflator
25. y downward on the pull tab The Inflatable PFD should fully inflate within 5 seconds Get into shallow water just deep enough that you can stand with your head above the surface See if the Inflatable PFD will float you on your back or just slightly back of vertical In a relaxed floating position verify that your mouth is well above the water s surface Note the effect of where you hold your legs and how you float Get out of the water and remove the Inflatable PFD Completely deflate the Inflatable PFD using the oral inflator see Deflating the Inflatable PFD p 7 Remove the CO3 cylinder bayonet assembly from the inflator Let the Inflatable PFD dry thoroughly Re arm and Repack the PFD p 13 HOW DO YOU TEST YOUR PFD USING THE ORAL INFLATOR 1 2 19 No spare parts or re arming kits are needed to test your Inflatable PFD Remove the CO3 cylinder bayonet assembly to prevent inadvertent inflation which could potentially damage the Inflatable PFD Inspect the cylinder to confirm it is unused Fig 10 Unscrew and remove the cap and the bobbin MD3087 only Otherwise the bobbin will disintegrate during water immersion Put on the Inflatable PFD Get into shallow water just deep enough that you can stand with your head above the surface Inflatable PFD Owner s Manual 5 If you are a weak swimmer or non swimmer orally inflate the Inflatable PFD partially so that you are supported well enough to be able to comp