Home

- Superior Sauna & Steam

image

Contents

1. with the second year and for the ten year warranty of the original purchaser only at the original installation only SCANDIA will at its option repair or exchange at the Factory all parts which it finds have become inoperative during said warranty period due to a defect in material or workmanship except the following parts which are excluded from this warranty the gas valve pilot generator heating element con tactor timer switch thermostat and high limit 5 This warranty in its entirety becomes null and void if unit is rented or to be used for rental purposes or installed in any mobile or fixed prefab rental room If original purchaser is a corporation then the president of said cor poration shall be construed as registered Original Owner for all purposes herein otherwise this warranty in its entirety becomes null and void 6 This warranty in its entirety becomes null and void if unit has been installed by an unlicensed party by and or in the city and or county where installation is made Furthermore if unit is disassembled and or tampered with in any way possible by any one individual and or company then this warranty in its entirety becomes null and void SCANDIA reserves the right to substitute new equipment or parts on any orders for replacement hereunder but shall not be obligated to do so This warranty is solely for the benefit of the original purchaser and no one else and only if the installation and operating instructions a
2. Heater Model Serial j SANL MANUFACTURING ULTRA SAUNA HEATER Proudly made in USA since 1964 SMALL HEATERS 3 0 4 5 KW Installation Instructions amp User Manual ULTRA SAUNA HEATER INSTALLATION INSTRUCTIONS SMALL HEATERS 3 0 4 5 KW SCA Sin MAA N OPAC I ORI mM i BEFORE YOU START Heater and controls must be installed by a licensed electrician Heater must be installed according to local codes Plastic must be removed from shell before operating heater Sauna door must always open outward Sauna door can never include a lock YOUR HEATER SHOULD INCLUDE Controls Main Heater Unit Sauna Rocks Thermostat sensor wall cover not included with T model heaters Installation Instructions Warning Sign HEATER SIZING Ultra Sauna Heaters Small 16 W x 10 3 4 D x 23 1 4 H 45208 30 sq ft 9 2 sq m SAUNA ROOM VENTING GUIDELINES Sauna room should be vented according to manufacturers specifications or Scandia sauna room specification found in the Scandia sauna installation instructions Improper ventilation is dangerous for the sauna user s health When the door is under cut there is no other venting required in small sauna rooms You should have between 3 4 to 1 between the finished floor and the bottom of the door If further venting is preferred or required the inlet vent should be below the heater or near the base of the heater Outlet vent can be just below the top bench o
3. N OPAC I ORI mM i WIRING DIAGRAMS H Controls for T Model Heaters 3000 Watts to 6000 W atts Heaters Volts 240 208 Heater Controls High Limit Line Timer to High Limit on Base of Heater Power Feed W ires Thermostat Powerto L1 and L2 H eater Elements Heater Element Line T2 to heater elements F Controls 60 minute timer 3000 Watts to 6000 Watts Heaters Single phase only 240 208 Volts Circuit Breaker Wires from control to heater 240 208 12 5 14 4 20 sq ft 3 qty 14 ga 240 208 18 8 21 7 30 sqft 3 qty 10 ga Thermostat High Limit Line Timer to High Limit on Base of Heater P ower Feed W ires Power to L1 and L2 Heater Elem ents Heater Element Line T2 to heater elem ents SEANA MAA B OPAC I ORI mM i SAUNA HEATER OPERATING INSTRUCTIONS Installation steps A Remove the protective cover off the heater shell B Hang the heater in place or as specified by manufacturer C Fill the heater rock tray with the sauna rocks Note This sauna heater should not be operated without the recommended quantity of rocks D ENSURE GOOD AIR CIRCULATION AROUND SENSOR BULB Install the heater guard around rail around heater After installation is completed the heater should be turned on to maximum temperature for one hour to break any rocks having fault lines and to burn off the protective coating on the heater elements Do not enter the sauna room during the initial start up The smell of
4. ar is repositioned above the word AUTO Your Ultra Sauna heater has been engineered and built to the highest quality standards and is backed by this warranty to as sure your complete satisfaction 1 SCANDIA Mfg warrants on the terms and conditions set forth below for ten years to the Original Owner only at the Original Installation site only this equipment to be free from defect in material and or workmanship under normal use as specified in the equipment s instructions FROM DATE OF PURCHASE and thereafter 2 A TEN YEAR LIMITED WARRANTY applies only on the heater unit as manufactured by and at SCANDIA Mfg Manufacturing Plant and specifically excludes all components and or parts which are accessories therein namely the gas valve pilot generator heating element contactor timer switch thermostat and high limit for which their respective manufacturers warranties apply The TEN YEAR LIMITED WARRANTY does not apply for units that have been installed in commercial locations such as clubs condominiums apartments spas or military facilities In commercial locations Scandia will provide a one year warranty on the unit 3 During the first year SCANDIA will at its option repair or exchange at the Factory all parts which it finds have become inoperative during said warranty period due to a defect in material or workmanship without cost to cus tomer except for freight and or crating charges 4 For the period commencing
5. ced parts or heaters will be returned freight collect This warranty is effec tive only when the attached Factory Registration Stub is completed and returned to the manufacturer Please contact Scandia for return authorization at 877 467 2862 or via e mail info scandiamfg com Warranty stub must be mailed or completed online within thirty DAYS TO REGISTER AND VALIDATE THIS WAR RANTY WHICH BECOMES VALID ONLY IF THE HEATER HAS BEEN PURCHASED DIRECTLY FROM SCANDIA MFG AND OR AUTHORIZED DEALERS IN U S A its territories or possessions TO VALIDATE WARRANTY VISIT WWW SCANDIAMFG COM PRODUCT_REGISTRATION HTML AND REGIS TER YOUR PRODUCT ALL PRODUCTS MUST BE REGISTERED PRIOR TO ANY WARRANTY CLAIMS SCANDIA BAA M O PAC I ORI MN
6. cessed pehind cover A please ask your 10 12 12 24 hour timer mounted Scandia sales Heater rt representative Wall E mounted ioi Line feeds ground from inside Line feeds ground from Control box to Heater Sauna room Control box to Heater Ii 6 o it by 100 Gace a i CACCCRAnANANi ae j oT T cnini grill vent below heater improves efficiency of heater IMPORTANT NOTES Heater must be installed by a licensed electrician Heater must be installed inside the sauna room and mounted 10 12 from the floor Controls must be installed outside of the sauna room Thermostat capillary sensor bulb must be located inside the sauna room horizontal position approx 10 inches from ceiling All wiring must comply with Local and State ordinances all wiring into the sauna room must be rated for at least 90 degrees Celsius 194 deg Farenhiet Standard sauna ceiling height is 7 feet Consult all local codes before installation Warning signs must be installed at eye level on door and above heater Door must always swing outward Air intake vent must be installed below heater and an air exhaust vent should be installed Thermostat should be placed behind cover and out of control of guests members Setting should be no higher than 180 degrees farenheit 85 Celcius H control F control SCANZA MAA
7. n the opposite side near the opposite side of the heater SCAND MAA N OPAC I ORI mM i SAUNA HEATER GUARD RAIL PLACEMENT GUIDE SMALL Description 3KW 4 5KW 1 Minimum dimensions of heater guard must be 26 L x 16 d x 29 1 4 H Top rail of guard must be below heater vent CONTROL PANEL MODELS AND SIZES H control suitable for heater models 30240 T 30208 T F control suitable for heater models 30240 30208 45240 T 45208 T 60240 T T model heaters only 45240 45208 60240 Control Cover Control Cover Plate Control Box Plate Control Box a __ 6 3 SCANDIA 0 Q 30 22ga Brushed Da a i Aluminum 22ga Brushed I8 ga Galvanized Aluminum I8 ga Galvanized Paint loc Steel Paint loc Steel N CONTROL PANEL LOCATION All controls must be mounted on the outside of the sauna NEVER inside the room Sauna exterior wall RESIDENTIAL INSTALLATION For convenience place the control box at eye level by the door approximately 12 from the door opening and 52 from the floor see fig 1 For conduit and wire size type and quantities see specific heater wiring diagram charts COMMERCIAL INSTALLATION for 60 min timer follow the residential installation recom mendatio
8. ns For 24 hour timer you may place the control panel either in front of the sauna or in the mechanical or electrical room away from the sauna room Please note that the thermo stat capillary tube is only 4 ft long therefore for controls placed away from the sauna we rec ommend T model heaters where the thermostat is built in the heater itself SCANIA MAA N OPAC I ORI mM i STANDARD HEATER CONTROL CONFIGURATION Line Feeds Ground 60 min timer timer From Breaker Hit PETE EEE EEE EEE EEE Thermostat sensor bulb must be Note Control All Ultra Sauna panel on the outside of sauna room Hlcontro Recessed Box mounted heaters have the p thermostat built in the W arning Signs heater eliminating the need to have the thermostat sensor in the wall Line feeds ground from Control box to Heater mounted inside the sauna 10 from ceiling horizontal position Use supplied bracket to hold it in place LITT heaters can be ordered as T model THT from factory T model Heater Wall mounted inside sauna room NA EHH HAAT h View from outside of sauna Recommended grill vent below heater im proves efficiency of heater Option 1 Option 2 Controls near door Controls in remote location i Important Line Feeds Ground Line Bee i iii Control a rrom greaker For controls in i T panel on the remote locations outside of T model heater is SAUNA TOUI recommended mm Re
9. pplicable to the model purchased are followed These instructions are furnished with the unit and also are available by writing SCANDIA s warehouse These instructions are incorporated herein by reference as if set forth in full This warranty does not cover damages which appear to SCANDIA to have resulted from neglect alteration abuse mis use accident flood fore or other act of force majeure or other than normal use This warranty is expressly in lieu of other warranties or liabilities express or implied by the Company or its representatives and in lieu of all other obligations and liabilities for damage to persons or property caused in any manner by the heater or its component parts More specifically by not by way of limitation SCANDIA assumes no liability for damages which may occur as a result of neglect or intentional misuse of the unit and the purchaser or user of the unit agrees to assume all liability for the consequences of its use or misuse by such purchaser or user and his its or their respective employees and agents or other third person THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF NO REPRESENTATION OR WARRANTIES ARE MADE EXPRESSED OR IMPLIED OTHER THAN THOSE EXPRESSLY HEREIN SET FORTH TO THE ORIGINAL PURCHASER ONLY To obtain the benefits of this Warranty the inoperative parts and or complete heater must be sent to Scandia all shipping and crating charges prepaid And all repaired or repla
10. smoke and cracking of rocks will not re occur Sauna Timer Scandia Sauna controls come with standard 60 minute timer wall mounted outside the sauna and thermostat For T models the thermostat is located on the heater To turn on the heater turn the timer knob up the desired time up to the 60 min mark Leave knob at the setting and sauna will operate for one hour before shutting off auto matically Allow 30 minutes for room to heat up to an average sauna temperature The thermostat is marked with numbers 1 through 10 With 1 being the coolest temperature and 10 the highest Set the desired temperature Note Make sure the thermostat is on before setting up the time otherwise the heater will not heat up For 24 hour timer operation see attached Operating Guidelines for 24 hour digital timer Product Liability The buyer acknowledges that the goods sold to them by Scandia Manufacturing can Cause property damage and personal injury if not properly sized handled or installed The buyer further agrees to indemnify and hold harmless Scandia Manufacturing from any or all claims for damage loss and or liability arising out of improper handling siz ing and or installation of goods Programming Instructions 24 digital hour timer To Set or Change the Day and Time To clear entire memory press key Hold down the CLOCK key while pressing either the DAY HOUR or MINUTES keys Continue pressing until the desired da
11. y or number is shown Then simply lift finger off of the CLOCK key to set Display To Set Program ON OFF times ee cancel all prior Press TIMER key once to enter into program mode Display will settings show 1 ON Press DAY key to choose any of 15 dif ferent day combinations for the first ON time Note days of the week having the same program should be copied by selecting the desired combination of days ON AUTO OFF Selection Key Press the HOUR key and then the MINUTE key to select the de sired first ON time Indicator LED ON when connected to power source and contacts are closed Press TIMER key once Display will show 1 OFF Repeat previous step to select the desired OFF time Repeat the entire sequence to complete up to eight ON OFF times as de sired When programming is done press the CLOCK key then the MANUAL key repeatedly until the indicator bar is above the word AUTO To Review Program Press TIMER key repeatedly When done press CLOCK key to return to the time of day To Cancel Change Part of the Program Press TIMER key repeatedly until the particular ON or OFF time appears the repeatedly press the DAY key until the display show Set new ON and OFF time See To Set Programs To Override Automatic Operation Press MAMUAL key to move indicator bar to the desired ON or OFF position Note Timer will not resume automatic operation until indicator b

Download Pdf Manuals

image

Related Search

Related Contents

1 - Brother  LS-B50 - Onkyo  Générations 02.2006  AEG LAVAMAT 16810 User's Manual  SMC 6.1 - Oracle Documentation  HV-37 User Guide  通信機能付 環境放射線モニタRadi(ラディ) PA-1100 製品  FLETS接続サービス設定マニュアル(PDF)版  Deutsche Anleitung  fonte de alimentação dc regulada manual de instruções  

Copyright © All rights reserved.