1. User s Manual Electronic microprocessor controlled device for bee venom collecting Model BVC 0411 Bee venom collecting device g flashing slowly collector works good electronic device for safely collecting bee venom flashing quickly many bees on the market since 1992 Red LEL Red LED battery compartment amp solid red short circuit front wires a gt Hite te tentace batadas e gt flashing red batteries low p leS 2xAA Make sure the device is turned off Unscrew the bolts on this panel aPausing shortly every 50 seconds d EEEE cart anai hattniad Waimomatical me OFF after 40 minutes f Use 2 x AA 1 5 V alkaline teries Insert the new batteries a To restart nthe device OFF E model BVC 0411 IGK electronics Ltd wait 1 mip te and then turn it ON made in EU www beewhisper com 4 D 6 8 1 Visible wires of the device 6 Place for a sliding glass under wires 2 Red LED 7 Battery compartment 3 Green LED 8 Solid wood body 4 Compartment for electronics 9 Place for removing the lid on the 5 ON OFF button battery compartment How to use the device The device has a built in set of batteries and is ready for use right out of the box To start collecting bee venom put the glass directly below the stretched wires in the front angled side of the device The devices do not require any additional attendance or attaching Place the device at the hive entrance with the pointed part glass and wires towa
2. age sustained due to improper and or careless replace them at our cost use Shipping costs Wood part damage IGK electronics Bee Venom Collectors since 1992 www beewhisper com office igkelectronics com
3. device if left for long Always be careful about their polarity Use alkaline batteries size AA LR6 1 5V DO NOT use rechargeable batteries 1 2V One set of alkaline provides normal work for 3 5 months Alkaline batteries Duracell ultra digital MH1500 or GP Ultra Alkaline Battery size AACLR6 1 5V are used at 6 hours per day 5 days per week If water or another fluid wet the device let it dry in a warm place for 24 hours before turning on again Safety precautions Take all possible measures to ensure safe work with bee venom Work with gloves and protective glasses Make sure the venom does not get into your eyes nose or mouth Always work in a team of at least 2 Keep the glasses the devices and the venom itself out of children s reach other people away from food products or animals Wash your hands well after work Keep the clothes you used while you worked separately from your others Do not watch the LEDs directly for long from a distance shorter than 100cm Dimensions BeeVenomCollector BVC0411 BeeVenomCollector BVCO41 Iplaced in a box L 258mm W 158 mm H 38mm L 270mm W 170 mm H 45mm Weight 750 grams with glass and batteries Weight 850 grams Usage Tips Designed to work at temperatures between 10 and 40 degrees Celsius Keep in a dry place above 20 and bellow 55 degrees Celsius Warranty 2 years It includes It does not include We will repair products with damaged electronics or Any dam
4. ondition and separate the wires if needed The device will turn on and continue working automatically there is no need to turn it off on manually e Flashing RED batteries low Change the batteries with new ones If the batteries are completely dead none of the two indicators Red LED and Green LED should be working 5 seconds after you turn on the device Again in this case you should replace the batteries Reminder after manually shutting down the device you need to wait 1 minute before turning it on again Green LED This indication shows one of the following events collector works good triggered automatic protection when too many bees are on the device the humidity is too high e Flashing slowly collector works good e Flashing quickly too many bees on the device or humidity is too high The device shuts down automatically In a couple of seconds checks 1f what caused this is still present then attempts to turn on automatically If a protection has triggered and what caused the triggering 1s still present and the Green LED indication is flashing quickly it is possible the device to not turn off automatically after 40 minutes If that is the case turn the device off manually Changing the batteries Unscrew the bolts on the right panel battery compartment Bellow is the battery holding case Replace the batteries while making sure the polarity is correct Improperly inserted batteries might damage the
5. osition 0 i it Cian Bee venom scrapped off the glass after one session You see 2 cm of scale The dried bee venom might contain additional visible components they should be removed The final drying out of the venom is done in open test tube glasses over calcium chloride The venom in its final weight is kept in dark bottles in a dry place avoiding direct light Remaining moisture should be less than 10 The dehydrated venom can be stored in a refrigerator for over a year To increase the quality and preserve it even further the venom can be lyophilized treated this way and stored in a fridge the venom keeps its properties for 5 years Lyophilized bee venom The reasonable use of the device doesn t affect the extraction of the other bee products During the active season 0 2 to 1 grams of poison are produced from a bee family per day The best time to extract bee venom is during the early morning hours 1 2 hours before bees flight Duration of bee venom extracting can be from 30 minutes up to 2 hours per hive daily This is the venom weight when scrapped off the glass 5 20 minutes after the glass is removed from the device Red LED This indication shows one of the following events short circuit between the visible wires or batteries low Blinks in red color e Solid RED short circuit between the visible wires of the device Two or more wires are connected The device shuts down Check the device s c
6. rds the hive entrance Turn on the device using the button in position I The device starts working An indication that the device is working properly is the short blinking of the green LED about one time per second Every 50 seconds the device pauses for 10 seconds After 40 minutes work time the device turns off automatically That is the maximum time for bee venom collection in session per hive The device can be turned off manually before 40 minutes have passed by pressing the button in position Q When the device is turned off automatically the two LEDs turn off too To turn the device back on again press the button from position I to 0 Wait 1 minute then press it again in position I In 5 seconds the device is ready again the Green LED will blink shortly with green or blue light After 20 to 40 minutes turn off the device manually or let turn itself off in 40 minutes Leave the device for 5 20 minutes in a shady place without removing the glass Doing this lets the remaining bees fly away Now remove the glass there are white crystals on it Leave it in a shady place so the venom can dry and scrap it off using a razor Bee venom scrapped off the glass after one session Warning if some of the automatic protections has trigger and the red LED indicator is blinking it is possible in rare cases the device to not shut down automatically If such a case is present turn it off manually by pressing the button in p