Home
SIENNA Professional User Manual
Contents
1. NIE 13 33 MENU ITEM TOOLS 000ooe cece cee cece ceseceeccecescceeccecascecseeceasceeceecascecsaeceasseenseceaseeesseceaseteaeecsaseeesseenseeeeneeenas 13 A EE AE SEENEN 14 0014 _____ Steyourt Gef SIENNA Professional User Manual Secyourit GmbH 1 Introduction The program requires an active connection to the 230V power network via the USB network interface The trial version can be used without a network interface but it cannot be used to control any SIENNA devices that are present in the power network The configuration commands are disabled in the trial version SIENNA Demo ole is Project View Tools Refresh device data Active area Apartment Demo SIENNA gg geg wen veno Taa Taa FI A s aco A C D Heating P Lights B Sunblind A E Heating F al Lights B Fal Sunblind A Apartment Demo Demo Version 1 1 Operational Mode The program has two operational modes e Administrator mode All configuration and control functions are enabled in the administrator mode All available apartments will be displayed in this mode e User mode Only control funtions are enabled in the user mode Only the previously activated apartment will be displayed in this mode The program starts in the user mode A password is required to change from the user mode to the administrator mode The default password is admin 1 2
2. Tools Find devices Add devices Refresh device data Active area Apartment Demo SIENNA R I sl sl sl sl Deal ACD Display light 6 Garden 4 Hallway 7 Living Room 2 Heating P E Control CH S Bsa Sunbli Schedules Rename Living Room 5 Apartment Demo Lights B Demo version e Control e Group Switches on all devices included in the selected group e Group Off Switches off all devices included in the selected group e Group Dim Dims all dimmers included in the selected group to a preset value e Group Up Down Stop Controls all sunblinds included in the selected group e Schedules Manage schedules for all devices included in the activated apartment e Select a previously saved schedule by clicking the drop down list on the schedules screen or e Create a new schedule by clicking on the button marked New e Rename only in administrator mode Renames the selected group 04 Steyourt Gef SIENNA Professional User Manual Secyourit GmbH 23 Context menu Device group r S SIENNA Demo 15 Project View Tools Find devices Add devices Refresh device data Active area Apartment Demo E sema o Apartment Demo Q p a Baa aco aa Heating P Fal Lights B Display light 6 Actuator Motion detector Switch On Aff 1 Garden 4 Control 4 Schedules Rename L
3. a sensor within the apartment that is already configured Switch this sensor 10 times within a time interval of 5 seconds to activate the currently selected apartment The currently active apartment is highlighted in gray in the tree view displayed on the left side of the screen Please note that only a single apartment can be active at any one time Activating a new apartment automatically deactivates the previously active apartment SIENNA Demo demo es Project View Tools Find devices Add devices Refresh device data Active area Apartment Demo Samm NW Control 4 a Zra Schedules Heating P Lights B Sunblind A a l Heati Rename Lights B Fal Sunblind A Apartment Demo Demo Version Note The function described above is available only in the administrator mode If a particular apartment needs to be active in the user mode this apartment has to be activated in the administrator mode and saved as a project Steyourt Gef SIENNA Professional User Manual Secyourit GmbH 2 Context menu The context menu can be displayed by clicking the right mouse button 2 1 Context menu Apartment e SIENNA Demo en am Leite 2 Project View Tools Find devices Add devices Refresh device data Active area Apartment Demo as NN SW SW SN Control E Schedules Heating P Lights B Sunblind A Heat Rename Li
4. A SIENNA Professional User Manual V4 1 Secyourit GmbH Auensir 100 80469 M nchen Deutschland Tel 49 89 12294700 Fax 49 89 72430099 Copyright 2009 Secyourit GmbH SIENNA Professional User Manual Secyourit GmbH Table of contents 1 INTRODUCTION E 3 1 1 OPERATIONAL e 3 122 EE 3 1 3 SWITCHINGAND CONTROL 4 1 4 ACTIVATING AN APARTMENT stts tt esteet totte testne SEES SESE ESEESE 4 2 CONTEXT MENU bivisccssiscscesescssticsss sccesecssisccscelscecessesdenesscauesscs ssconsetssseesdseusesscouosesacesosessessdcouscvassesscasbessadseosexs 5 2 1 CONTEXT MENU APBARTMENT sto tt tettette etten 5 2 2 CONTEXT MENU GpOoUp 7 23 CONTEXT MENU DEVICE 8 2 4 CONTEXT MENU 9 25 CONTEXT MENU SENSOR 10 26 CONTEXT MENU 11 27 CONTEXT MENU REMOTE CONTROL 12 3 MENUITEMS srein snn eege ege Edge 13 3 1 MENU ITEM PROJECT 13 3 2 MENU
5. Commands e Find devices only in Administrator mode Searches the 230V network and displays all SIENNA devices that are connected to the 230V power network Please note that this command initializes the data set and deletes the currently displayed data e Find devices only in Administrator mode Searches for additional SIENNA devices that have been connected to the 230V power network The currently displayed data set is retained DI Steyourt GubH SIENNA Professional User Manual Secyourit GmbH e Refresh device data Updates device data Reads the current configuration settings and the state of the devices Please note that only unconfigured devices and devices that are attached to an active apartment are updated 1 3 Switching and control The actuators can be controlled by clicking the left mouse button either on the desired actuator icon or on the corresponding sensor icon 1 4 Activating an apartment In order to access a SIENNA device the corresponding apartment needs to be active Configuration and control of SIENNA devices is allowed only within an apartment that is active To activate an apartment proceed as follows a Click the SIENNA icon in the tree view displayed on the left side of the screen b Select the desired apartment and display the corresponding context menu by clicking the right mouse button c Click the menu item Activate to activate the selected apartment You will need to select
6. ated e Properties Displays the sensor parameters 10 14 SIENNA Professional User Manual Secyourit GmbH 2 6 Context menu Controller This context menu is only visible in the administrator mode Project View 8 SIENNA Demo 18b2008_englishxml Lea Tools Find devices E 53 SIENNA J Apartment 102 10 Refresh fsal Delete Loss RF Gate Rename a Controller Configure gt cf RF Gateway Properties H Egg Heating Fea Lights B Fea Plug point E een Scenarios a fsa Sunblind A Add devices Refresh device data Active area Apartment 102 10 Apartment 102 10 Controller RF Gateway Demo version Refresh only in administrator mode Updates the controller parameters Only for devices that are attached to an active apartment Delete only in administrator mode Deletes the controller from the current data set Rename only in administrator mode Renames the controller Contigure only in administrator mode Reset All device parameters are reset to factory values Assign channel Assigns SIENNA addresses to the channels of a remote control Deactivate learn mode Switches off the learn mode Create apartment Creates a new apartment address for the SIENNA devices Only for controllers in the unconfigured state Extend apartment Includes new unconfigured SIENNA devices in an existing apartment Only for controllers i
7. d in the currently selected apartment Please follow the instructions displayed on the screen 1304 _ _ Steyourt Gut SIENNA Professional User Manual Secyourit GmbH e Control e AllOn Switches on all the devices available within the currently active apartment This menu item is disabled if there is no active apartment e All Off Switches off all the devices available within the currently active apartment This menu item is disabled if there is no active apartment e All Dim Dims all the dimmers available within the currently active apartment to a preset value This menu item is disabled if there is no active apartment e All Up Down Stop Controls all the sunblinds available within the currently active apartment This menu item is disabled if there is no active apartment e Activate Deactivate Autostart If autostart is activated then the program will be included in the Windows O S autostart menu 3 4 Menu ltem e Help Opens the help file in PDF format e Activate product Used to activate a trial version The licence key is associated with a single network interface If the network interface is changed then the new licence key can be entered via this menu item e Info Copyright and version information about SIENNA Professional 1404 Steyourt Gef
8. e control 04 Steyourrt Gut SIENNA Professional User Manual Secyourit GmbH 3 Menu items 3 1 Menu item Project Open Close Save project files Open Opens a previously saved project file Close Closes the currently project file Save The currently displayed data set is saved in a file XML format Save as The currently displayed data set is saved in a file XML format Exit Exits program 3 2 Menu item View Spatial view of the SIENNA devices Blueprint a Menu item File Load blueprint Reads in a blueprint in JPG GIF TIFF PNG or BMP format e Default blueprint Reads in the default blueprint data e Print screen Prints the data on the screen e Close Closes the spatial view b Commands e Refresh device data Updates the device data Reads the current configuration settings and the state of the devices e Position devices Enables available SIENNA devices to be positioned on the blueprint The control functions are deactivated in this modus 3 3 Menu item Tools Change mode Enables switching between the two operational modes A password is required to switch from the user mode to the administrator mode The default password is admin Change password only in administrator mode Enables the administrator password to be changed The password can have between 0 and 10 characters The default password is admin Schedules Manage schedules for all devices include
9. ghts B Sunblind A SW SS Apartment Demo Demo Version e Activate only in administrator mode Activates the selected apartment and allows the included devices to be controlled and configured e Control e A On Switches on the devices available within the selected apartment e All Off Switches off all the devices available within the selected apartment e All Dim Dims all the dimmers available within the selected to a preset value All Up Down Stop Controls all available sunblinds within the selected apartment 514 Steyourrt Gef SIENNA Professional User Manual Secyourit GmbH e Schedules Manage schedules for all devices included in the activated apartment e Select a previously saved schedule by clicking the drop down list on the schedules screen or e Create a new schedule by clicking on the button marked New Schedules az Available Schedules All on X Properties Name Apartment All on Apartment 102 10 Status Group Not active All available groups Schedule Action Device Set All On All available device groups Run at 14 33 36 Run on Mon Tue Wed Thu Fri Run Edit Delete Close e Rename only in administrator mode Renames the selected apartment d4 Steyourrt Gef SIENNA Professional User Manual Secyourit GmbH 2 2 Context menu Group pr SIENNA Demo Co xs Project View
10. iving Room DDDDD Sunbind Apartment Demo Lights B Hallway 7 Demo Version e Control e Device group On Switches on all devices included in the selected device group e Device group Off Switches off all devices included in the selected device group e Device group Dim Dims all dimmers included in the selected device group to a preset value e Schedules Manage schedules for all devices included in the activated apartment e Select a previously saved schedule by clicking the drop down list on the schedules screen or e Create a new schedule by clicking on the button marked New e Rename only in administrator mode Renames the selected device group 804 Steyourt Gef SIENNA Professional User Manual Secyourit GmbH 2 4 Context menu Actuator SIENNA Demo x Project View Tools Find devices Add devices Refresh device data SIENNA Apartment Demo EA Control D o Refresh AED Delete Fal Heating P Rename Configure 4 al Lights B Properties Display light 6 3 Garden 4 Hallway 7 Living Room 2 DDDDD Living Room 5 a Ea Sunbind Active area Apartment Demo Apartment Demo Lights B Living Room 2 Demo Version e Control Allows the actuator to be controlled directly from the PC This menu item is enabled only if the corresponding apartment is activated e Refre
11. n the configured state This menu item is enabled only if the corresponding apartment is activated Properties only in administrator mode Displays the controller parameters 1104 _ Seeyourt Gut SIENNA Professional User Manual Secyourit GmbH 2 7 Context menu Remote control This context menu is only visible in the administrator mode SIENNA Demo 18b2008_english xml fase View Tools Add devices Refresh device data Active area Apartment 102 10 D SIENNA Apartment 102 10 Refresh E Zal Plug point E Delete Tel 8 Rename Controller Configure gt o Sl RF Gateway Deal Heating P g o E Pump Valve Zeal Lights B Central On O Display light Garden 4 Hallway 7 8 Living Room 2 E 0 Living Room m D Apartment 102 10 Lights Central On Off Demo Version Refresh only in administrator mode Updates the device parameters Only for devices that are attached to an active apartment Delete only in administrator mode Deletes the device from the current data set Rename only in administrator mode Renames the device Configure only in administrator mode Delete channel Deletes the channel assignment This menu item is enabled only if the corresponding apartment is activated Properties only in administrator mode Displays the configuration parameters of the remot
12. sh Updates the actuator data Reads the current configuraton settings and the state of the actuator Only for devices that are attached to an active apartment e Delete only in administrator mode Deletes the actuator from the current data set e Rename only in administrator mode Renames the actuator e Contigure only in administrator mode Reset All device parameters except the rotary and sliding switch settings are reset to factory values for actuators with a built in sliding switch Change address Allows the device address to be set directly from the PC Set sliding switch Allows the sliding switch position to be set directly from the PC Only Create apartment Creates a new apartment address for the SIENNA devices Only for actuators in the unconfigured state and with Firmware version gt 8 0 Extend apartment Includes new unconfigured SIENNA devices in an existing apartment Only for sensors in the configured state This menu item is enabled only if the corresponding apartment is activated e Properties Displays the actuator parameters 9 14 SIENNA Professional User Manual Secyourit GmbH 2 5 Context menu Sensor sienna Demo x Project View Tools Add devices Find devices SIENNA E Apartment Demo aco aa Heating P Fal Lights B DDDDD a Ea Sunbind Refresh device data Di
13. splay light Active area Apartment Demo Refresh Delete Rename Configure Properties Display light 6 Garden 4 Hallway 7 Living Room 2 Living Room 5 Apartment Demo Lights B Display light 6 Demo Version e Refresh Updates the sensor data Reads the current configuraton settings of the sensor Only for devices that are attached to an active apartment e Delete only in administrator mode Deletes the sensor from the current data set e Rename only in administrator mode Renames the sensor e Contigure only in administrator mode Reset All device parameters except the rotary and sliding switch settings are reset to factory values Set timer Allows the timer runtime to be set directly from the PC Only for sensors with timer functionality Set temperature Allows the temperature set point to be adjusted directly form the PC Only for modules with temperature sensors Change address Allows the device address to be set directly from the PC Set sliding switch Allows the sliding switch position to be set directly from the PC Only for sensors with a built in sliding switch Create apartment Creates a new apartment address for the SIENNA devices Only for sensors in the unconfigured state Extend apartment Includes new unconfigured SIENNA devices in an existing apartment Only for sensors in the configured state This menu item is enabled only if the corresponding apartment is activ
Download Pdf Manuals
Related Search
Related Contents
Whirlpool ED20DFXEB00 User's Manual EMULFOR - Atlantic Chimie industrie medela® dominant 50 - Schmidt Medizintechnik Manual de Instruções Vídeo Porteiro Manual de Instruções Kalorik 33005 User's Manual Handyprobe 2 user`s manual LD ROADKID - Adam Hall Punto singolo di ancoraggio EAP „SPIDER“ 0024-9505ES Rev 0 FOLD LINES_ES - Tune-Rite Copyright © All rights reserved.