1. if the motor is on Also if you listen close to the motor you should be able to hear it running If the motor does not start up when you flip the switch most likely the 9V battery is dead To change out use a key or similar shaped object to pry open the hatch seen in lower left of Figure 1 on the base of the telescope mount and change out the battery 10 Declination Brake Won t Lock Telescope in Place The declination brake can become loose so that even locked in place the telescope will move This has an easy fix TO FIX The declination brake knob has 2 positions locked and unlocked as seen in the top and bottom pictures in Figure 5 respectively In the unlocked position you can twist the knob to tighten and then lock the brake again This will make the declination brake have a tighter hold so the telescope will not move when the brake is set 11 RA Brake Won t Lock Telescope in Place If you have tightened the set screws on the knob and it still doesn t lock the telescope then there is an issue deep down in the base of the telescope mount and currently we do not have a fix for this Figure 5 Declination brake Can unlock the brake so that it is parallel to the mechanism it rests on seen in the top picture Twist the knob and lock the brake in place perpindicular to the mechanism seen in bottom picture so that the brake has a tighter hold on the telescope Figure 6 End of night storing position 4 things 1 Point tele
2. Observatory 8 inch Telescopes Tips Tools amp Quick Fixes Rhiannon Griffin August 7 2014 1 Tools Needed e Allen wrenches for set screws 2 sizes e For collimating Phillips head screwdriver amp slotted screwdriver 10 Some Tips for a Smooth Observing Experience If you are setting up the telescopes for a class or a star party DO NOT let students or the public set up or take down the telescopes That s asking for trouble Prior to the event use the Allen wrenches to tighten set screws not too tight but snug This will help to prevent things loosening up during the night Center the declination arm As seen and described in Figure 2 Align the finder scope When at the observatory on Asp I like to use the OU symbol on the stadium sign Do not turn the RA fine adjustment knob if the RA brake is set tightly The telescope will resist movement and it can damage the telescope Warn your students about this Make sure your students know to loosen the brakes before moving the telescope so that the brakes do not become stripped To properly adjust the height of the eyepiece assembly loosen the screws holding the diagonal in place turn the eyepiece assembly and then lock into place again Make sure students know this Before class star party remove the diagonal eyepiece assembly tighten the collar of the diagonal shiny metal part in Figure 3 and make sure set scr
3. ews are tight This will help to prevent the eyepiece assembly from falling off the telescope At the end of an event make sure telescope is in its proper position so that it fits easily into the storage crates 4 things make sure telescope is pointed toward the mount with handle bar on top with the eyepiece pointed down also known as sad eyepiece and check that RA motor is turned off Also when storing the telescope in the crate make sure the finderscope is on the part of the telescope that is up not in the styrofoam See Figure 6 The telescopes are named and labeled and so are their respective storage crates At the end of the night make sure the appropriate telescope goes in its own crate The rest of this manual is a description of common problems and how to fix them poe af Lyn i atts t Bay Ponp 5 T i z yA 4 Hulihuli liN Figure 1 2 of the knobs that can be loose so that turning them achieves nothing There is the RA brake the silver L shaped one and the RA fine adjustment knob silver wide cylinder On the L shaped one you can see at the corner of the L is the set screw that can be tightened The other knob has a set screw that can be seen on its base 4 Knobs Won t Tighten The knobs sit on posts and the post needs to turn for the mechanism to tighten If the set screws are not tight enough the post won t turn and turning the knob doesn t achieve anything Figure 1 sho
4. it is not As seen in Figure 4 you can pop off the orange cap covering the secondary mirror by taking Figure 3 Eyepiece assembly with current eyepiece diagonal and collar piece Figure 4 Figure showing how to remove orange cover over collimation screws Use a slotted screwdriver to pry off the cover and a Phillips head screwdriver to adjust the screws using tiny subtle adjustments a slotted screwdriver and applying pressure in the groove THIS STEP SHOULD BE PERFORMED WITH CARE The secondary mirror is mounted such that some pressure is ok however don t let the screwdriver slip as this would damage the corrective lense Under the orange cover is 3 screws for a Phillips head screwdriver With the telescope still pointed at a bright point source unfocused SLIGHTLY turn one of the screws in one direction If the center ring moves towards the edge i e makes it worse turn the screw in the other direction This should only take slight adjustments to fix so use subtle tiny turns In this manner put the center ring in the middle so it looks like 2 concentric circles To place the orange cover back on the telescope line up the 2 hooks on the cover seen in Fig 4 right with the slots on the secondary mirror and press firmly 9 RA Motor Not Turning On The RA right ascension motor counteracts the motion of the Earth s rotation so that the telescope roughly tracks objects across the sky There is an indicator light that is red
5. k Also the forks on the end of the declination arm can break causing the declination adjustment to be unusable To avoid this center the arm before class event 7 Diagonal Eye Piece Falls Out or Is Droopy The eyepiece sits in a diagonal which has a collar attached to it These 3 pieces are shown in Figure 3 The collar piece screws into the diagonal be sure not to cross thread The eyepiece sits in the diagonal with 2 set screws and then the collar fits inside the telescope with 2 more set screws These set screws can be turned by hand Make sure these screws are tight so the eyepiece does not fall out of the telescope To turn the eyepiece to adjust for height one should loosen the screws that hold it into the telescope while holding the eyepiece and then turn the diagonal to adjust height Tell students this is the proper procedure to adjust for height 8 Collimation Issue Can t Get the Telescope to Focus This takes time to fix It is not advisable to do this unless you have 20 minutes before the telescope is needed A telescope that is not properly collimated will appear out of focus no matter how you adjust the focus knob The primary and secondary mirrors can get out of alignment over time and become uncollimated TO FIX Point at a bright star planet Unfocus the telescope until you see a donut If the center of the donut is in the middle then the telescope is collimated if it is off to one side then
6. scope so that its facing the mount 2 Have handle directly on top of the telescope Lock both brakes 3 Sad eyepiece point the eyepiece so that it hangs down 4 Check that RA Motor is off
7. ws the brake knob silver and L shaped and the fine adjustment knob wide silver cylinder TO FIX tighten the set screws using the Allen wrenches provided Do not over tighten the screws this will strip the heads just tighten until nice and snug 5 Focus Knob Falls Off This knob is located at the base of the telescope by the eyepiece assembly It has a similar set screw as the brake knobs and fine adjustment knobs Use an Allen wrench to tighten 6 Twisting the Declination Knob Too Much If you twist the declination knob too much in one direction what we call the declination arm will get caught to one side see Figure 2 If you keep turning past this point the small knob and copper bushing opposite the declination knob can fall off and be hard to find in the dark so don t do this To avoid this center the arm before class star party One has to really keep turning the knob to have the arm reach a side Also if you keep turning the knob after the declination arm has reached one side it can break the fork ends off the arm itself which could make the declination adjustment knob unusable Figure 2 Upper left shows center best configuration of declination arm the central bar seen in the picture Upper right shows the arm against one side If you keep turning the declination knob in the same direction the smaller knob and bushing shown in the bottom picture can pop off the other end and be nigh impossible to find in the dar