Home
Quick Start Guide
Contents
1. gt 3 inches Facial amp Fingerprint Recognition Series Product User Manual 3 Add User Press Add on the User Mgt interface to display the Add User interface as shown below User ID Enter a user ID 1 to 9 digits user IDs are supported by default Name Enter a user name 12 characters user names are supported by default Fingerprint Enroll a user s fingerprint and the device displays the number of enrolled fingerprints A user can enroll 10 fingerprints at maximum Password Enroll a user s password The device supports 1 8 digit passwords by default Face Enroll a user s face Group No x Setting in the group of user Role Set the rights of a user A user is set to ordinary user by default and can also be set to administrator Ordinary users are only granted the rights of face fingerprint or password verification while administrators are granted access to the main menu for various operations apart from having all the privileges granted to ordinary users Auto Test lt Exit Dn Upload Add User User 10 1 Mame anser ii kp EEN SPa gt Ts i IG Face Group No 1 VL Fole User E Cad User Acces Exit Save Photo Enroll a user s photo During user verification is success the user s photo is displayed on screen User Access Set the lock control and access control parameters 24 Error Use the Home tab to apply fr 1 to
2. Converter 3 TCP IP Mode A Crossover cable The device and PC connected B Straight cable The device and PC connected to directly LAN WAN through switch Lanswitch IP Address 192 168 1 100 Subnet Mask 255 255 255 0 a gt IP Address 192 168 1 124 Subnet Mask 255 255 255 0 10 Cautions 1 Power cable is connected after all the other wiring If the device is working abnormally please shut down the power first then make the necessary check Kindly reminds you that any hot line work may damage the device and it is not included in the warranty 2 We recommend the 3A 12V DC Power supply Please contact our technical staff for details 3 Please read the terminals description carefully and wiring by rule strictly Any damage caused by improper operations will not under warranty 4 Keep the exposed part of wire less than 5mm to avoid unexpected connection 5 Please connect the GND before all the other wiring especially under the environment to prevent the overlarge instantaneous electrostatic to damage device 6 Do not change the cable type because of long distance between the power and the device 7 Please use specified RS485 wire RS485 active converter and bus type wiring 2 Main Menu 2 Main Menu There are two types of rights respectively granted to two types of users the Ordinary users and administrators Ordinary users are only granted the rights of face fingerprint p
3. Enroll Card interface 2 The Punch Card interface pops up as shown below Swipe your ID card properly in the swiping area For details see 1 6 Appearance of Device 3 If the card passes the verification the device will display a prompt message Read Successfully Card No oss and returns to the Add User interface 4 Press Save to save the current information and return to the previous interface Press Exit to return to the previous interface without saving the current information Enroll Card Enroll Card Punch Card Face Group No 1 1 a ne N jp Y 1 4 Role User p 4 k kA l Photo User Access C Exit N 4 note 3 inches Facial amp Fingerprint Recognition support Mifare card function It is an option function if you want to customize the Mifare card function please consult our commercial representatives or pre sales technical support engineers 30 Error Use the Home tab to apply r 1 to the text that you want to appear here 3 6 Enrolling a Face 1 Press Face on the Add User interface to display Add User the face enrollment interface 2 On the displayed face enrollment interface turn your head to the left and right slightly raise and lower your head according to the voice prompts so as to NN enroll different parts of your face into the system to Group No assure the accurate verification See 1 2 Enrollment Face Expr
4. I ILock gt 1A And the lock is near to the device Device does not shares power with the lock A Utock 12V_ ItockS 1A os B Urock 12V C The lock is far apart from the device 1 The system supporst NO LOCK and NC LOCK For example the NO LOCK normally open at power on is connected with NO terminal and the NC LOCK is connected with NC terminal 2 When the Electrical Lock is connected to the Access Cont rol System you need to parallel one FR 107 diode equipped in the package to prevent the self inductance EMF affecting the system do not reverse the polarities 5 Connected with Power 4 Connected with other parts Input DC 12V 500mA 50mA standby Door Bell Positive is connected with 12V negative is connected with GND do not reverse the polarities fp DC12V EXT BUTTON Exit Button Alarm Power Door Sensor Voltage output lt DC 12V for Alarm T device output current Urock lock lock voltage lock current 6 Wiegand Output 7 Wiegand Input The device supports standard Wiegand 26 output The device has the function of Wiegand signal input It s upports to as a reader device it has a very good compatibility connect with an independent card reader They are installed each side of the door to control the lock and access together Access Control 1 Please keep the distance between the device a
5. MultiBio 700 Installation Guide Version V1 1 Date Nov 2011 1 Equiment Installation MultiBio 700 Mounting Paper only for your reference 1 Post the mounting template on the 2 Remove the screw on the bottom 3 Take away the back plate wall Drill the holes according to of device the marks on the template holes for screw and wiring 4 Fix the back plate on the wall according to the mounting paper 5 Fix the device to the back plate 2 Structure and Function Fe Access Control System Function 1 If a registered user verified the device will export the signal RS485 TCP IP I woe to unlock the door RS232 RS485 Converter 6 2 Door sensor will detect the on off state If the door is un af E 6 lock Senso 3 As the d evice is removed illegally it will output an alarm signal No F oy Door Bell External Reader EV 5 External exit button is supported it is convenient to open the Exit Button expected opened or improperly closed the alarm signal 4 digital value will be triggered 4 External card reader is supported door inside 6 External door bell is supported O 7 Supports RS485 TCP IP modes to connect with PC One PC can Alarm i manage multiple devices K Warning No operating with power on 3 Lock Connection 1 Shares power with the lock Device shares power with the lock Urock 12V
6. assword or card verification while administrators are granted access to the main menu for various operations apart from having all the privileges granted to ordinary users Press Menu on the initial interface to access the main menu as shown in the following figure FE Add User User Mgt Check In AX at ke Data Mgt Date Time A lt Auto Test Dn Upload Sys Info Exit N 4 The main menu includes nine sub menus Add User Through this submenu you can add a new user and input the information on the device including the user ID name fingerprint face card password rights group No and user access User Mgt Through this submenu you can browse the user information stored on the device including the user ID name fingerprint face card password rights group Nox and user access Here you can also add 21 3 inches Facial amp Fingerprint Recognition Series Product User Manual modify or delete a user s information Comm Through this submenu you can set related parameters for communication between the device and PC including the IP address gateway subnet mask baud rate x device No and communication password System Through this submenu you can set system related parameters including the basic parameters interface parameters fingerprint face and attendance parameters Keyboard definitions Access settings firmware update etc to enable the device to meet the u
7. essions 3 If your face image is enrolled successfully the Photo User Access lt Exit Save iii l I system will display a prompt message and automatically return to the Add User interface 4 Press Save to save the current information and return to the previous interface Press Exit to return to the previous interface without saving the current information Add User Group No 1 Role User f h Exit SAVE Phata User Access 31
8. eyboard interface see 12 1 T9 Input Instructions 3 After the user name is entered press Save to save the current information and return to the previous interface Press Exit to return to the previous interface without saving the current information Add User Add User File Face f Fingerprint 2 Password Fingerprint Password Password e card ea Group No 1 Role User Phote User Access H8o0o004 BS Tip The device supports the 1 to 12 characters names by default 26 Error Use the Home tab to apply fr 1 to the text that you want to appear here 3 3 Enrolling a Fingerprint 1 Press Fingerprint on the Add User interface to Add User display the Enroll Fingerprint interface 2 On the displayed Enroll Fingerprint interface place your finger on the fingerprint sensor properly according to the system prompt For details see 1 3 Finger Placement 3 Place the same finger on the fingerprint sensor for three consecutive times correctly If the enrollment eee EEE succeeds the system will display a prompt message 7 maj and automatically return to the Add User interface If the enrollment fails the system will display a prompt message and return to the Enroll Fingerprint interface In this case you need to repeat the operations of step 2 4 You can enroll the backup fingerprint by pressing Fingerprint again A user can enroll 10 finge
9. nd Access Control or Card Reader less than 90 meters Please use Wiegand signal extender in long distance or interference environment 2 To keep the stability of Wiegand signal connect the device and the Access Control or Card Reader in same GND in any case Other Functions 1 Manual Reset If the device does not work properly because of misoperation or other abnormality you can use Reset function to restart it Side View Back View Operation Remove the black rubber cap then stick the Reset button hole with a sharp tool the tip diameter less than 2mm 2 Recovery Factory Settings You can use the tamper switch to recovery factory setting such as device number system password IP address RS485 address etc More information please refers to the user manual Operation Press the tamper switch three times after the alarm being triggered 30 seconds but no more than 60 seconds Reset Button Tamper Switch Note The user data won t be cleared 9 Communication There are three modes that the PC software communicate and exchange information with the device RS232 RS485 and TCP IP and the last two mode support remote control Terminals 1 RS232 Mode PC Serial Ports Warning No operating with power on 2 RS485 Mode EN Please use specified RS485 wire RS485 active converter and 485 gt ode a bus type wiring 485 485 Terminals RS485 Bus RS485
10. rprints at maximum 5 Press Save to save the current information and return to the previous interface Press Exit to return to the previous interface without saving the current information 21 3 inches Facial amp Fingerprint Recognition Series Product User Manual Enroll Fingerprint 201 0 Enroll Fingerprint 201 0 Add User Place Finger Enrolled Successfully Quality Passward Score e 7 Face Group No 1 Aole User Phata 28 Error Use the Home tab to apply r 1 to the text that you want to appear here 3 4 Enrolling a Password 1 Press Password on the Add User interface to Add User display the password management interface 2 On the displayed keyboard interface enter a password and press OK Re enter the password according to the system prompt and then press OK Group No BS Tip The device supports 1 8 digit passwords l Role User Photo by default 3 After the password is entered an interface is displayed as shown below Press Save to save the current information and return to the previous interface Press Exit to return to the previous interface without saving the current information Add User Tt Card Group No 1 b Rale User Photo User Access T 29 3 inches Facial amp Fingerprint Recognition Series Product User Manual 3 5 Enrolling an ID card 1 Press Card on the Add User interface to display Add User the
11. ser s requirements to the greatest extent in terms of functionality and display Data Mgt Through this submenu you can perform management of data stored on the device for example deleting the attendance records all data clear administrator restore to factory settings and query records Date Time Through this submenu you can set the alarm time and duration or set the Bell Auto Test This submenu enables the system to automatically test whether functions of various modules are normal including the screen sensor voice face keyboard clock tests and screen calibration Dn Upload Through this submenu you can download user information and attendance data stored in the device through a USB disk to related software or other fingerprint recognition equipment Sys Info Through this submenu you can browse the records and device 22 2 Main Menu information Any user can access the main menu by pressing the Menu key if the system does not have an administrator After administrators are configured on the device the device needs to verify the administrators identity before granting them access to the main menu To ensure device security it is recommended to set an administrator when using the terminal initially For detailed operations see 3 8 Modifying User Right mew www www ww mm 23 Cad gt gt gt gt gt gt gt gt
12. the text that you want to appear here 3 1 Entering a User ID The device automatically allocates an ID starting from 1 for every user in sequence If you use the ID allocated by the device you may skip this section 1 Press User ID on the Add User interface to display the user ID management interface 4S Tip The user ID can be modified during initial enrollment but once enrolled it cannot be modified 2 On the displayed keyboard interface enter a user ID and press OK If the message The user ID already exists is displayed enter another ID BS Tip The device supports 1 to 9 digits user IDs by default If you need to extend the length of current user ID numbers please consult our commercial representatives or technical pre sales 3 After the user ID is entered press Save to save the current information and return to the previous interface Press Exit to return to the previous interface without saving the current information 25 Add User Role User Photo en 4 Exit User Access 3 inches Facial amp Fingerprint Recognition Series Product User Manual 3 2 Entering a Name Use T9 input method to enter the user name through Add User the keyboard 1 Press Name on the Add User interface to EPET display the name input interface fenem 1 2 On the displayed keyboard interface enter a user Sea P name and press X For details of operations on the k
Download Pdf Manuals
Related Search
Related Contents
Fagor FC-86 ART fridge-freezer Trek7 aahf32 Instructions / Assembly Copyright © All rights reserved.
Failed to retrieve file