Home

regled - Framiral

image

Contents

1. so you can use it vertically or horizontally depending on the clinical need Wall bracket installation Figure 6 Mounting the Regled Wall bracket mounting kit Figure 7 Wall mounting The wall bracket is mounted on the bar Rotate the bar 90 so you can access to the 2 holes spaced apart 8cms Mark the spots on the wall drill the two holes insert the wall anchors and screw the wall bracket to the wall FRAMIRAL 4 Documentation REGLED rev2 Electric connection You can plug the transfo to 110V or 220V with the appropriate plug socket EU US Connect the other end at the back of the device Figure 9 Transfo Figure 8 Bar side connection The device can be left connected all the time with no risk The power consumption on Sleep mode is almost null less than 20mW Power on off A power switch is located on the Regled to turn it on and off M A Every time the device is turned on it will apply the current button settings a M V b e gt H lt N TA ir y h NC Ae gt Q 24 a te gt r Figure 10 ON OFF switch S FRAMIRAL 5 Documentation REGLED rev2 USING THE REGLED Set the initial parameters Figure 11 Buttons M Operating modes MI scrolling left to right M2 scrolling right to left M3 alternate scrolling left right left M4 random spot unpredictable MS random pursuit unpredic
2. LEO Dee gt D2D mm c_ mrhrm_nrmmm mm mmmog _ 6 Figure 12 Replace batteries ccssccerssscsuscoersescsscoersesensscoersesenascourse 10 Figure 13 Replace the batteries en oceanele eee ierti aie iat ste 10 Nw 11 Documentation REGLED rev2 FRAMIRAL FRAMIRAL 107 avenue Jean Maubert 06130 GRASSE FRANCE Tel 33 422 480 107 Fax 33 956 372 472 Email contact framiral tr NW 12
3. USER MANUAL REGLED Document rev2 Nw Documentation REGLED rev2 Overview REGLED is a cylinder 1 meter long 6cms wide containing a light bar of 126 LED controlled by a microprocessor The therapist can make the patient work on the fixation ocular pursuit saccadic system head eye synchronization oscillopsy The therapist can associate the Head pointer lazer for a better feedback The patient will then be able to have a better control and understanding of the exercises Figure 1 Headpointer This device is powered via a wall plug provided It is not recommended to use another kind of power plug than the one provided by Framiral REGLED can be controlled via e button panel located on top of the device e infrared remote controller PRODUCT CE x 1 Documentation REGLED rev2 DESCRIPTION General description The light bar contains 126 luminous adjacent dots materialized by a 7 62mm wide red LED rendering a 960 12mm long bar Figure 2 Regled Each operating mode will set a different scrolling strategy It is possible to limit de range of movement The scrolling light movement is also adjustable from 10 to 99 s Two LED 5mm wide located at each end of the bar can run in two different modes for extreme excentration exercises The two modes 6 and 7 for these exercises are not available on the remote controller Digital display On the left side th
4. ere is a 2 digits display beside the remote controller infrared receiver The digital display will flash the current mode for a few seconds every time it is changed via the buttons or the remote controller lll L 3 N _ 4 TY v re Daia x T e FRAMIRAL M Figure 3 Digital display S FRAMIRAL Documentation REGLED rev2 Button panel On the right hand side of the bar you can find the button panel to program the exercise when starting the device Figure 4 Button panel Remote controller The remote controller provided allows you to change the settings of an exercise while running Its range is about 3 meters from the infrared sensor It is powered by 3 batteries included and we recommend changing them annually for a better functioning see maintenance chapter Figure 5 Remote controller FRAMIRAL Documentation REGLED rev2 INSTALLATION The device is calibrated to run at a distance of 1 meter from the patient Indeed the luminous dot scrolling speed s corresponds to the instantaneous speed of the eye in its socket head still or the speed of the head relative to the neck eye still Any other distance from the patient would give a wrong angular speed The device has to be mounted on a vertical wall at about 1 2m high so the sitting patient s head 1s horizontal The device is mounted on a rotating wall bracket 360 free
5. ffset When setting the parameters the selected setting is displayed for 3 seconds on the 2 digits display FRAMIRAL 7 Documentation REGLED rev2 Using the remote controller The infrared remote controller allows you to change those settings except mode M6 M7 1 Mode MI 2 Mode M2 3 Mode M3 4 Mode M4 5 Mode M5 L Increments working area Width LI to LS Decrements working area Width LS LI F Shifts the working area to the left FI FS to FC f Shifts the working area to the right FC to FS FI S Switch scrolling mode Linear Sinusoidal V Increments scroll speed from 10 to 99 s when in MI M2 and M3 Increments the duration of the LED flashing period from 1 0s to 9 95 when in M4 and M6 v Decrements scroll speed from 99 to 10 s when in MI M2 and M3 Decrements the duration of the LED flashing period from 9 9s to 1 0s when in M4 and MO When using the remote controller the control buttons at the back of the device are disabled If you want to use them you need to turn Off and On the Regled When holding the V or v button on the remote controller you can quickly increment or decrement the scroll speed Nw 8 Documentation REGLED rev2 MAINTENANCE No maintenance is necessary The device is made to be set up in a low humidity location at room temperature 10 to 35 C Avoid liquid splashes on the device and the remote controller Remove dust regularly
6. table direction delay speed M6 alternate extreme spots the two external LED alternatively turn on at stable frequency M7 random extreme the two external LED randomly turn on S Linear or Sinusoidal Switch from linear scrolling to sinusoidal For mode M1 M2 et M3 only V Scrolling speed s check that the distance between the device and the patient is 1m The speed varies from 10 to 99 s for M1 M2 and M3 mode For the M4 M6 and M7 modes the frequency is specified in 1 10s from 1 0 to 9 9 seconds FRAMIRAL 6 Documentation REGLED rev2 E Shifting the scrolling window The led bar is made of 8 segments of 16 LED here under marked from FI to F8 SEGMENTS F8 F7 F6 F5 F4 F3 F2 FI The F command sets the right end of the LED working area to the right end of the selected segment FI to F8 Example ii set to F5 the LED working area will be from the left end of the bar to the right end of F5 so the left half of the Regled The special FC mode will automatically center the LED working area L Width of the working area The working area width is divided into 8 segments from L1 to L8 L1 is 1 segment long L2 is 2 segments long etc L8 is the maximum size Example if set to L2 the LED working area will be from the right end of the selected Fx segment to the right end of Fx 2 So when combining the L and the F commands it is possible to adjust the LED working area on Width and O
7. with a dry cloth Nw Documentation REGLED rev2 TROUBLESHOOTING Replace the remote controller batteries The batteries lifetime depends on the usage of the remote controller To prevent any inconvenience you can replace them annually To replace the batteries unclip the top part of the controller DO NOT UNSCREW THE BACK Figure 12 Replace batteries Take the batteries out and replace them with AAA 1 5V LRO3 batteries Ensure the polarity is respected Figure 13 Replace the batteries FRAMIRAL 10 Documentation REGLED rev2 Table of Illustrations Flere L FIC ACO OINIEC EI 2 s ea int ai ine bi lama ra J 1 Figure 2 Regled aaaaaaaaaaaaasasaasasannannnnannnnannnnannnnannnnnnnnnnnnnnnnnnnnnsnnnninanaa 2 Figure 3 Digital CISA Y 12600 0005 Ss ioanad Di alte n aia ari ba arad ii 2 FUG 4 Button Dan iy 54445 y544441544523 0 0144a taia a a i 88 k n W n n n 3 Figure 5 Remote controller kk keke 3 Figure 6 Mounting the Regled ceea eee kk keke ka 4 Figure 7 Wall mounting aaiaaaaaaaaaasaaaasanuannananannannnnannnnnnannnnnnnnnninnnninanina 4 l e Bar side CONNECT ON RKSSRRNURR o a tat ilie i ta lite ni it 5 Duha FO sasa ei atena ei alei ai ai mm nl m nm mlr tape tati 5 Figure 10 ON OFF switch aaaaaaaaaaaaaaaaaaaa asannnnnnnannnnnnnnnnnnnnnnnnnnnnnnnnnnninii 5 Fera LL L gt BU