Home
A9GT-80V4 type Video input interface module User`s Manual
Contents
1. Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Ryoden Automation Ltd 500 Corporate Woods Parkway Vernon 10th Floor Manulife Tower 169 Electric Hills IL 60061 Road North Point HongKong Tel 1 847 478 2100 Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria China Ryoden Automation Shanghai Ltd Tecnica Ltda 3F Block5 Building Automation AV Paulista 1471 Conj 308 Instrumentation Plaza 103 Cao Bao Rd Sao Paulo City Sao Paulo State Shanghai 200233 China Brazil Tel 86 21 6475 3228 Tel 55 11 283 2423 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd RD Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea HAN NEUNG TECHNO CO LTD Tel 49 2102 486 0 1F Dong Seo Game Channel Bldg U K Mitsubishi Electric Europe B V UK 660 11 Deungchon dong Kangsec ku Branch Seoul Korea Travellers Lane Hatfield Herts AL10 Tel 82 2 3660 9552 8XB UK Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 ALEXANDRA ROAD 05 01 02 Italy Mitsubishi Electric Europe B V Italian MITSUBISHI ELECTRIC BUILDING Branch SINGAPORE 159943 Tel 65 6473 2308 Centro Dir Colleoni Pal Perseo Ingr 2 f Via Paracelso 12 20041 Agrate B Thailand F A Tech Co Ltd E l Milano Italy 898 28 29 30 S V City Building Office Tel 39 039 6053344 Tower 2 Floor 17 18 Rama 3 Road Spain Mitsubis
2. and Outline Dimension Drawing 105 1 agat sov4 Unit mm inch Description Rating plate ee a E a 4 Installation Procedure A985GOT V back 1 Insert the A9GT 80V4 connector into the option module interface at the back of A985GOT V 2 Tighten the attachment screw to a point within the prescribed torque range of 39 to 59 Necm To remove the unit reverse the installation procedure Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region
3. areas and electronic parts of this module directly Doing so can cause a module malfunction or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the module Not doing so can cause a fire failure or malfunction Always secure the cables connected to the module e g run them in conduits or clamp them Not doing so can cause module or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the module Doing so can cause module or cable damage or a malfunction due to a cable contact fault Before handling the unit touch a grounded metal or similar object to discharge the static electricity from the human body Failure to do so may cause the unit to fail or mulfunction DISPOSAL PRECAUTIONS Dispose of this product as industrial waste Manuals The following manuals are relevant to this product Refer to the following list and order the required manuals Detailed Manual Manual No ae A985GOT A975GOT A970GOT A960GOT User s Manual SH 4005 Available as option 1DMO099 Relevant Manual For relevant manual refer to the PDF manual stored within the drawing software 1 Overview This User s Manual describes the A9GT 80V4 type Video input interface module hereinafter A9GT 80V4 A9GT 80V4 can display the image taken by up to 4 video camer
4. coaxial shield cable Internal current consumption A 5 D VC 0 19 value for individual module Weight kg Ib 0 15 0 33 Maximum cable length m feet 30 98 42 2 2 Coaxial cable specifications 1 Coaxial cable Use high frequency coaxial cable 3C 2V 5C 2V conforms to JIS C 3501 for coaxial cable The following shows the coaxial cable specifications 2 Se lS z sees 4 lS z lS renee S S Z S S S 1 eo 0 eM OSC S S 4 KS KS S lS sae Ae RoR SSS Internal E condcuctive l material Insulating N rn material xternal conductive material Cable diameter 5 4mm 0 21in 7 4mm 0 29 in Allowable bending radius 22mm 0 87 in or more 30mm 41 18 in or more Internal conductive material 0 5mm 0 02 in 0 8mm 0 03 in diameter Annealed copper wire Annealead copper wire 3 1mm 0 12 in Polyethylene 4 9mm 0 19 in Polyethylene External conductive material 3 8mm 0 15 in Single annealed 5 6mm 0 22 in Single diameter copper wire mesh annealed copper wire mesh Connector plug for 3C 2V BNC Connectar plug ler aG EN P 3 N1 CAU is recommended E Construction Insulation material diameter Applicable connector plug 2 Connector and connector cover e GOT connector Use BNC connector for GOT side connector The following shows the connection method for BCN connector and coaxial cable a Structure of BNC connector and the coaxial cable Parts of
5. the BNC connector Structure of the coaxial cable D Outer sheath Outer conductor SY Nut Washer Gasket Insulating material Internal conductive material Pug SHen Clamp Contact P PE 1 Remove the outer sheath of the end of the coaxial cable as shown below 4 Remove the outer sheath 2 Slip a nut a washer a gasket anda Nut clamp on the coaxial cables as Washer shown below and loosen the outer Gasket conductor Insulating material 3 Cut the outer conductor insulating Internal conductive material material and internal conductive om LH material to specified dimensions OTni Clamp and shown below 6mm outer conductor Cut the outer conductor and extended 0 24inch it over the end of the clamp Soldering 4 Solder the contact to the tip of the internal conductive material 5 Insert the contact assembly in the plug shell and engage the plug shell with the nut 1 Soldered part must not have excess solder mound 2 The tail end of the contact must come into close contact with the cut end of the insulating material The contact must not be cutting in the insulating material 3 Apply solder quickly so that the insulating material may not be deformed by heat e Connector at the video camera and vision sensor Use the connector applicable to the video camera and vision sensor 3 Precautions for cable preparation The cable must be 30m 98 42feet or shorter 3 Name of the Part s
6. M ITSUBISHI Mitsubishi Graphic Operation Terminal A9GT 80V4 type Video input interface module Thank you for buying the MELSEC GOT Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product User s Manual Hardware MODEL AYGT 80V4 U MODEL CODE 1DM123 IB NA 0800167 D 0406 MEE 2000 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Always read before starting use When using Mitsubishi equipment thoroughly read this manual and the associated manuals introduced in the manual Also pay careful attention to safety and handle the module properly These precautions apply only to the installation of Mitsubishi equipment and the wiring with the external device Refer to the user s manual of the CPU module to be used for a description of the PLC system safety precautions These e SAFETY PRECAUTIONS e classify the safety precautions into two categories DANGER and CAUTION l Procedures which may lead to a dangerous condition and cause DANG ER death or serious injury if not carried out properly Procedures which may lead to a dangerous condition and cause CAUTION superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual i
7. as on the A985GOT V by connecting with A985GOT TBA V and A985GOT TBD V hereinafter abbreviated as A985GOT V It is possible to use A985GOT V as the vision sensor monitor Image data Video cam A985GOT V A9GT 80V4 Tht Od Vision sensor AS5OVS or other The camera power pack may be necessary depending on the vision sensor used e A9GT 80V4 cannot be mounted to the GOT other than A985GOT V e For details of the system configuration refer to the GOT A900 Series User s Manual GT Works Version5 GT Designer Version5 compatible Connection System Manual e For details of the video window to display on A985GOT V refer to GT Works Version5 GT Designer Version5 Reference Manual e One of the following software packages are required for A9GT 80V4 F version of SW5D5C GTWORKS E GT Works Version5 or higher F version of SW5D5C GOTR PACKE GT Designer Version5 or higher After opening the box check that the following items are present Description A9GT 80V4 2 Specification 2 1 AIGT 80V4 specifications Video inputeveten Color NTSC format PAL format interlaced format Monochrome EIA format CCIR format interlaced format Number of video input channels 4 channel 640x480 possible to reduce to 320x240 160x120 Display Size IPIXgIes 720x480 possible to reduce to 360x240 180x120 Video external connection method Coaxial cable Applicable wire size 75Q
8. hi Electric Europe B V Spanish Bangkpongpang Yannawa Branch Bangkok 10120 Carretera de Rubi 76 80 Tel 66 2 682 6522 08190 Sant Cugat del Valles Indonesia P T Autoteknindo SUMBER MAKMUR Barcelona Spain Jl Muara Karang Selatan Block A Utara Tel 34 93 565 3131 No 1 Kav No 11 Kawasan Industri France Mitsubishi Electric Europe B V French Pergudangan Jakarta Utara 14440 Branch ner Te PAN a a ndia essun stems Put Ltd 29 POU EVara dES BOUVEISS Jart Electronic Sadan NO 111 Unit No15 Nanterre Cedex France M I D C BHOSARI PUNE 411026 TEL 33 1 5568 5568 Tel 91 20 712 2807 South Africa Circuit Breaker Industries LTD Australia Mitsubishi Electric Australia Pty Ltd Tripswitch Drive Elandsfontein Gauteng 348 Victoria Road PostalBag No 2 South Africa Rydalmere N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper
9. n a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS Do not bundle control lines or communication wires together with main circuit or power lines or lay them close to these lines As a guide separate the lines by a distance of at least 100 mm 3 94 inch otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS Before mounting or dismounting this module to or from the GOT always shut off GOT power externally in all phases Not doing so can cause a module failure or malfunction CAUTION Use this module in the environment given in the general specifications of the GOT User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to GOT or screw damage STARTUP AND MAINTENANCE PRECAUTIONS Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a module failure or malfunction STARTUP AND MAINTENANCE PRECAUTIONS CAUTION Do not disassemble or modify any module This will cause failure malfunction injuries or fire Do not touch the conductive
Download Pdf Manuals
Related Search
Related Contents
新商品案内 新商品案内 2010 Graco 309584H User's Manual Samsung PL50A440P1D User's Manual ごみの分け方・出し方 心得手帳(PDF BSQUARE® Corporation Remote Device Administrator for use with DEFY Model DGS 150 150 User's Manual INSTRUCTIONS DE RETRAIT/D`INSTALLATION : LÈVE RCS5133CB RCS5140B RCS5145B - Nářadí USE+MAINTENANCE BOOK Copyright © All rights reserved.