TRIAXIAL ELF Magnetic Field Meter TM-192/TM-192D
Contents
1. Diameter 6 3mm internal Diameter 2 0 mm EN 13 TENMARS TM 192 D 16 Safety Precaution For cleaning the instrument use a soft dry cloth Never use a wet cloth solvents or water etc Operation Altitude Up to 2000M Operating Environment Indoors use This instrument has been designed for being used in an environment of pollution degree 2 17Software installation 192D Please put the CD in the PC that will be connected to this meter Please select the USB driver that will be installed such as E TM 192D PL 2303 Driver Installer exe windows 2000 SP4 windows XP SP2 click twice on the left key of the mouse to install the USB driver Select the SETUP EXE i e E TM 192D SETUP EXE and installs the desktop icon Tack out the CD from PC after completed the installation of the desktop icon Use the USB cable to connect the meter and computer according to the drawing Select the desktop icon TM 192 and click twice on left key of the mouse to run the procedure 18 Note Caution this symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal EN 14
2. key to view logged readings mode Press SET Ah or v key to scroll through the readings Press key to exit this mode EN 11 TENMARS TM 192 D 13 Specifications Display 4 digits Triple LCD display Range 20 200 2000 mG 2 20 200uT Resolution 0 01 0 1 1 mG or 0 001 0 01 0 1 uT Frequency response 30Hz to 2000Hz E Sensor Triple Axis X Y Z Accuracy 20 mG 2uT 3 0 30dgt at 50Hz 60Hz 2 5 5dgt at 50Hz 60Hz 5 5dgt at 30Hz 2000Hz Over load LCD display OL Sample rate 2 5 times per second Battery 9V NEDA 1604 IEC 6F22 or JIS 006P Battery life Approximate 100 hours Operating temperature amp humidity 5 1 40 C below 80 RH Storage temperature amp humidity 10 C to 60 C below 7096 Weight About 230g Dimensions 173 L 80 W 32 H mm Accessories User s manual 9V battery Carrying case MINI USB 4P MALE to USB A Type cable CD disk 192D EN 12 TENMARS TM 192 D 14 Battery replacement WARNING If the symbol appears on the LCD please replace the battery immediately e Turn off the instrument Open the battery cover and remove the battery e Replace with four 9V NEDA 1604 IEC 6F22 or JIS 006P size battery Install the battery cover 15External DC Power External AC to DC adapter Voltage 9Vpc 8 14VpcMax Supply current gt 300mApc e Socket pin Positive Ground Casing External
3. the default value is triaxial total magnetic field reading press key to independent three single axis magnetic field readings and triaxial total magnetic field reading permanently lock and keep the reading displayed the LCD press E or press again to unlock To retain the maximum and minimum value press ie and the reading value displayed on the LCD will keep updating to the maximum value Press again to select minimum value press and hold down key 2 seconds to exit the maximum and minimum mode Due to the magnetic interference of the environment field factors this magnetic field meter could display a reading value that is lower than 0 5mG prior to measuring This is not a malfunction of the tester EN 4 TENMARS TM 192 D With the tester in hand move slowly towards to the object under measurement until it is physically touched Notice how the field intensity increases as you move closer to the object If the power of object was turned off during the measurement the reading of tester should return to zero unless there is the electromagnetic from other sources are detected EN 5 TENMARS TM 192 D 6 Clock setup e This meter clock to introduce 24 hour time Press key to clock setting mode 1 SET key to select option to adjust key to change the digit 55 key to store the setup exit the mode EN 6 TENMARS TM 192 D 7 Auto power
4. TENMARS TRIAXIAL ELF Magnetic Field Meter TM 192 TM 192D Triaxial Magnetic Field Meter EMFIELF Motor TM 1920 IJ e co HB2TM1920000 Table of Contents T1 10 Ot C2 ntroduction oe dentifying Parts Measurement Procedures lock Auto power off setup Continuity data logging setup Clear data logger Erase all data logger memory Single data memory Viewing logged reading control key 5 1 Battery replacement External DC Power Safety Precaution Software installation 192D IN OLE l2 TENMARS TM 192 D 1 Introduction Safety precautions should be taken against electric appliances in places including medical institutions schools and residential districts where people usually stay for a long time to prevent patients babies and senior citizens from exposure to high electromagnetic waves An electromagnetic wave simply means the wave motion of the electromagnetic field EMF The change in electric fields produces magnetic fields and the change in mag
5. netic fields can also generate electric fields The fluctuation of correlation between each other is known as electromagnetic waves which is a form of energy similar to light and heat that can be transmitted either by radiation in the air or by an electric conductor It is suggested that rearrangements should be made in families and work locations where electromagnetic fields are detected the strongest in order to avoid prolonged exposure to excessive electromagnetic fields Application This meter is applied to measuring electromagnetic fields of extremely low frequency ELF of 30 to 2000Hz It is capable of measuring the electromagnetic field radiation intensity that is produced from electric transmission equipment power line microwave oven air conditioner refrigerator computer monitor video audio device and so forth e The magnetic field unit is Tesla T Gauss G milli Gauss mG or micro Tesla u T 1 T 10 000 1 1 000 mG EN 1 TENMARS TM 192 D 3 Features Uses three internal orthogonal sensors to test a wide range of ELF magnetic fields independent of measurement angle The tester is designed to provide user a quick reliable and easy way to measure magnetic field radiation levels around power lines home appliances and industrial devices The tester is a cost effective hand held instrument that was designed and calibrated to measure magnetic field radiation at different bandwidths from 30HZ
6. off setup 55 key again to auto power off time setting mode 2 5 PIee iE AM e Press oA time a 55 to store the setup exit the mode This meter the auto power off time default value is 5 minutes for cancellation auto power off please set time as 00MM J key to change the auto power off EN 7 TENMARS TM 192 D 8 Continuity data logging setup Press key again to continue data logging interval setting mode 3 SET REC a t key to select option to adjust key to change the value 55 key to store the setup exit the mode EN 8 TENMARS TM 192 D 9 Clear data logger memory Press key again to clear data logger memory for last record setting mode 4 SET n n Li Li I 29 I Press key to clear data logger memory for last record Press key to clear data logger memory for last record and exit the mode EN 9 TENMARS TM 192 D 10 Clear all data logger memory 55 key again to clear data logger memory for all record setting mode 5 SET a LL e Press record 4 Press S to store the setup exit the mode key to clear data logger memory for all EN 10 TENMARS TM 192 D 11 Single data memory key each time to store the display reading and memory location in memory 12 Viewing logged reading control key READ e Press
7. to 2000HZ Display micro Tesla u T or milli Gauss m G units Data hold HOLD gt maximum Hold MAX and minimum Hold MIN function Auto range or manual range select mode Datalogging capacity with Memory Size 500 data sets or 9999 data sets 192D USB PC interface 192D Time and calendar function Low battery indication Over load display OL Auto power OFF function EN 2 TENMARS 4 Identifying Parts EN 3 TM 192 D 1 LCD display 2 Power key 3 maximum Hold and minimum Hold key 4 Data Hold key 5 Record dada and Setup function left key 6 Range and Setup function up key 7 Reading and Setup function right key 8 Setup function key 9 Units and Setup function down key 10 Enter key 11 Calibrate point for Triple axis 12 External power DC 9V 13 USB interface TM 192D 14 Tripod mounting screw 15 Battery cover TENMARS TM 192 D 5 Measurement Procedures Press key turn the meter press 0 key again to turn OFF the meter G T Press key to select milli gauss mG or micro tesla uT unit Position the front of the meter to measure the electromagnetic waves Read the measured value When manual range select mode LCD will shown the mark The display of OL on the highest position indicates there is an overload on the reading Press Fange to select a higher range for measurement again This meter displays
Download Pdf Manuals
Related Search
Related Contents
TEAM MANAGERS` MANUAL - Home » East Perth Football Club MG-2.0 User Manual Konzeptionelle und technische Weiterentwicklung eines Brother EM-430 User's Manual COMETH COMETH-LITE USER GUIDE 第64回特別講演記録 - 日本核医学会関東甲信越地方会 Electrolux EOC5951AAX Kramer Electronics VS-33VXL video switch Génie frigorifique et génie climatique Copyright © All rights reserved.