Home

1 Compiler, Prom, Versions, Libraries, Options 1.1

image

Contents

1. Diagram 1 31 The Window of the Internal Graphics Editor in Editing Mode Lines are generated in the editing mode Diagram 1 31 of the editor by selecting the processing function Generate Line This is implemented by sequentially selecting the startand end pointofthe line by clicking with the left hand mouse key in the working area Points can be generated as lines of length 1 by selecting the startand end pointto be the same Filled in areas are drawn as lines lying next to one another Characters are created from lines Deleting a line in the editing mode Diagram 1 31 ofthe editorrequires one ofits two starting points to be selected by clicking with the left hand mouse key The line to be deleted will be marked by a small white line Repeated clicking of the left hand mouse key on the same point will acknowledge the delete intention and the line is removed 7 32 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 5 11 Communication Island 1 5 11 1 Define Communication Island Invoking this function is not necessary for simple plant configurations in which the island each only contain one rack To increase the c
2. Diagram 1 17 The Differing Screen Window Areas 1 5 8 The Menu Bar of the Internal Graphics Editor The menu bar of the internal graphics editor consists of the two menus File and Edit 1 5 8 1 The File Menu The file menu contains functions for loading and saving internal graphics libraries as well as the menu item for exiting the editor Siemens AG 465 981 7101 23 Edition 02 96 7 21 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options File New Laden Speichern Speichern als Ende Load Save Save as Exit Diagram 1 18 Create New Internal Graphics Library Selection ofthe menu item New causes an empty internal graphics library to be created and loaded The name of the library is only defined during the saving procedure If a library is currently been processed that has been modified but not saved then the function File New prompts whether the modified library should be saved first File Load Laden Speichern Speichern als Ende Save Save as Exit Diagram 1 19 Load Internal Graphics Library This function loads an already existing internal graphics library for processing in the editor A file selection window Diagram 1 20 is popped onto screen for the selection of this library If a library is currently being processed that has been modified and not saved then th
3. Diagram 1 30 The Window ofthe Internal Graphics Editor in the Overview Mode Edition 0 2 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options Display Line The function Display Line is activated after switching to the editing mode of the editor Diagram 1 31 The individual lines of the current internal graphic is drawn with a small white line if the left hand mouse key is pressed and dragged across the working area in this function STRUG G Innengrafik Editor ol Datei Edit Dateiname scousr00 gast struc Ink_igr makros v4 igr Klasse l Zeichen c w Zeichen selekt Linie erzeugen Gross lt gt Klein Klasse Zeichen w Linie anzeigen w Linie loeschen A Z a z Klasse Zeichen Siemens AG 465 981 7101 23 Edition 02 96 7 31 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options g69igr pgm of File Edit File name scousr00 gast struc Ink_igr makros v4 igr 4 FB class 1 ID char c w Select graph Create lines Edit lt gt Overview Class ID char x Show lines Delete lines A Z a z Class ID char
4. Messages from the compilation process are displayed in the window Message Output Basic Dialog Siemens AG 465 981 7101 23 Edition 02 96 7 1 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 1 2 FP COMP Compile Function Packet This function is only active i e the text of the sub menu is not ghosted when a function packet is selected If no function packet is selected then the text of the sub menu is ghosted 4 Ansicht Makros 10010 10010 selekt Funktionspaket selekt Makro Beschaeftigt l E Bitte warten FP COP sinus 4 4 View Macros 10010 10010 Selected FP Selected Macro E Please wait FP COP sinus L 4 ml Diagram 1 2 Compile Function Packet Compile Macro FP COMP Selected FP The selected function packet is compiled using this function The function is immediately implemented i e no further prompting occurs Configuring errors with regard to the SIMADYN D regulations are detected by the compiler and the number of Errors and Warnings reported The FP EDIT must be re invoked to correct these errors Function packets containing errors or uncomplied function packets are saved as ufp An error free compiled function packet is saved as cfp Remark The STRUC compilation will not be correct when ufp and cfp extensions ofa function packet name exist simul taneously This can occur when a function packetis copied into a master pro
5. STRUC G User manual 7 Compiler Prom Versions Libraries Options g69igrpgm Datei Klasse A N B O C P Zeichen selekt y Linie erzeugen w Linie anzeigen Linie loeschen D Q Dateiname Zeichen Gross Klein Klasse A Z lt gt a z Klasse E R F S G T H U UV J W K X L Y Zeichen Zeichen M Z Klasse 1 Klasse 1 Klasse 2 Klasse 2 Klasse 3 Klasse 3 Klasse 4 Klasse 4 Klasse 5 Klasse 5 Klasse 6 Klasse 6 Klasse 7 Klasse 7 Klasse 8 Klasse 8 Klasse 9 Klasse 9 Edition 02 96 Men leiste Informationsleiste Funktionsleiste Arbeitsbereich Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options E g69igrpgm e File Edit Menu Bar File name FB class Dchar Selectgraph Create lines Edit lt gt Overview Class ID char w Show lines Delete lines A Z lt gt a z Class ID char Function A N B O C P D Q E R F S G T H U IN J W K X L Y M Z Information Area Working Area Class 1 Class 1 Class 2 Class 2 Class 3 Class 3 Class 4 Class 4 Class 5 Class 5 Class 6 Class 6 Class 7 Class 7 Class 8 Class 8 Class 9 Class 9
6. UNIX command the content of the archiv file is loaded tar tvff fp name or m mp name With the following UNIX command error image files of the archiv file are loaded tar xvf f_ lt fp name gt If the error image is not immediately downloaded then it will be overwritten by the next error image since The directory HOME struc Ink_tmp fel can only hold one error image You should therefore immediately download a generated error image and subsequently delete it in the directory HOME struc Ink tmp fel 1 5 6 Internal Graphics Editor The chapter describes the internal graphics editor of STRUC G Itis designed to process the internal graphics that symbolize the block functionality in the graphics function packeteditor and during plotting ofthe function packets Diagram 1 15 7 16 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options The internal graphics editor is invoked from the basic dialog via the menu item OPTIONS Internal Graphics Editor and operates within its own screen window Diagram 1 17 INTEGR3 10T1 Innengrafik Internal Graphics Diagram 1 15 Internal Graphics of a Function Block Internal graphics for the standard block library FBSLIB and also for macros are defined after the installation of STRUC The application of an internal graphics editor is practical when special internal graphics are to be create
7. for the first time in a configuring session The corresponding PC also has an SINEC H1 interface board with the name H1 installed in addition to the serial interfaces The column island of the panel Addressing shows all the lines allocated with names i e a maximum of 16 islands can be accessed by STRUC G The displayed example defines that the island CQB can be accessed via the COM2 interface of the PC i e via a DUST1 connection with 9600 baud The panel Interface defines which physical interface and also implicitly which protocol will be utilized Only one interconnection can be selected in this panel Siemens AG 465 981 7101 23 Edition 02 96 7 33 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options If the interface COMI or COM2 is selected then the corresponding serial interfaces on the UNIX PC are intended These interfaces correspond internally to the UNIX device dev ttyla and dev tty2a The DUST1 protocol will be automatically utilized The transmission speed must then be selected in the panel Baud Rate The destination island to which the interconnection leads from the serial interface must be entered by the user into the STRUC G system in the panel Addressing by selecting the corresponding island in column C Only one island can be accessed via a serial interface and therefore only one button can be selected If the processes of a communication island or their utilities can be accessed via
8. those with the identifying character A Z This is necessary since the overview mode only has enough space to display half of the internal graphics contained in the process library Class respectively Class This button permits switching to the internal graphic with the same identifying characters ofthe previous respec tively of the next block class Character respectively Character This button switches to the internal graphic with the previous respectively with the next identifying character ofthe current block class 7 28 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 5 10 2 Processing Functions The processing functions are selected by radio buttons contained on the left hand section ofthe function strip The selected function is displayed by a filled in marking after selection of the corresponding button by clicking with the left hand mouse key Selecting Characters The function Selecting Characters is active in the editor overview mode The current internal graphics is selected in the overview mode by clicking on the desired internal graphics symbol in the working area with the left hand mouse key Block class and identifying character ofthe current internal graphic are displayed in the information strip see Diagram 1 29 STRUG G Innengrafik Editor ol Datei Edit Dateiname scousr00 gast struc Ink_igr m
9. 1 7101 23 Edition 02 96 7 13 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options The selection is implemented by activating the buttons in one ofthe library lines A B or C column FB libraries or IB libraries A sub menu is allocated to each button Select Deselect The function Select is only active when the button is designated with Empty The available libraries are listed in a selection window when Select is invoked A library can only be allocated once i e this library is no longer listed as available when selectis re invoked The FB libraries mustbe selected forthe configuring offunction pack ets or the IB libraries for the configuring of master programs The allocation of the FB libraries must be same for all function packets of a processor program One ofthe library lines A B or C allocated libraries can be deselected by selecting the function Deselect in the popped up sub menu The library is then no longer active The button is then designated with Empty The version ofthe supplementary libraries mustalways be the same as the version ofthe GSW Basic Software The release can however differ The following applies Block are available for P16 Function Packets P32 Blocks are available for P32 Function Packets Blocks for the P16 and for the P32 function packets are normally available Libraries consists of several inter dependent files shown in the example for the libra
10. 7 Compiler Prom Versions Libraries Options 1 Compiler Prom Versions Libraries Options 1 1 STRUC Compiler 1 1 1 MP COMP Compile Master Program This function is only active i e the sub menu text is not ghosted when a master program is selected If no master program is selected then the text in the sub menu is ghosted Beschaeftigt EH Bitte warten MP COP handmp Selected MP NC wait MP COP um Diagram 1 1 Compile Master Program MP COMP Selected MP The selected master program is compiled using this function The function is immediately implemented i e no further prompting occurs Configuring errors with regard to the SIMADYN D regulations are detected by the compiler and the number of Errors and Warnings reported The MP EDIT must be re invoked to correct these errors Non compiled master programs or master programs with errors are saved as ump An error free compiled master program is saved as cmp Remark The STRUC compilation will not be correct if ump and cmp extensions of a master program name exist simultaneously This can occur when a master program has been copied into a project directory atthe operating system shell in which a master program of the same name already exists Therefore please check whether a master program ofthe same name already exists before carrying outa copy operation Ifthe answeris Yes then rename omp or erase
11. AUTOCOMP All Macros This function is only active i e the text of the sub menu is not ghosted when the macro directory is selected All macros of the selected project are compiled using this function An error window Diagram 1 5 is popped onto screen when errors occur during the compilation The compilation errors in the macros are listed with the correspondingly detected number of error and warning messages AUTOCOMP Selected Macro Subdirectory This function is only active i e the text of the sub menu is notghosted when a macro sub directory is selected If no macro sub directory is selected then the text of the sub menu is ghosted All macros of the selected macro sub directory are compiled using this function An error window Diagram 1 5 is popped onto screen when errors occur during the compilation The compilation errors in the macros are listed with the correspondingly detected number of error and warning messages Siemens AG 465 981 7101 23 Edition 02 96 7 5 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 2 PROG Load Program Memory Sub Module Download 12 1 Load Program Memory Sub Module This function is only active i e the textofthe sub menu is notghosted when a processor program is selected Ifno processor program is selected then the text of the sub menu is ghosted Ansicht Makros l selekt Prozessor Attributspeicher loeschen Attributspeicher loeschen EEPROM loesche
12. DYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options Neu Laden Speichern Speichern als Ende New Load ave Save as Exit Diagram 1 21 Save Internal Graphics Library This function saves the processed internal graphics library If the library has not yet been defined with a name after invoking the function File New then the function File Save as pops a file selection window onto screen Diagram 1 23 File Save As Neu Laden Speichern Speichern als Diagram 1 22 Save Internal Graphics Library under Another Name This function is designed to save the processed internal graphics library under another name The file selection window Diagram 1 23 is therefore popped onto screen 7 24 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options Datei Filter scousr00 gast struc Ink_igr igr Directories Dateien struc Ink_igr A fba123 v4 igr makros v4 igr V Auswahl scousr00 gast struc Ink_igr fbaneu v4 igr OK Filter Abbrechen File Filter scousr00 gast struc Ink_igr igr Directories Files struc Ink igr A fba123 v4 igr struc Ink_igr macros v4 igr V Selection scousr00 gast struc Ink_igr foaneu v4 igr Diagram 1 23 File Selection Window During Saving of an Internal Graphics Library This window permits either an existing
13. akros v4 igr Klasse l Zeichen c Zeichen selekt Linie erzeugen Gross lt gt Klein Klasse Zeichen w Linie anzeigen w Linie loeschen A Z a z Klasse Zeichen A N B O C P D Q E R F S G T HU IV J W K X L Y MZ assel L asse 1 asse 2 asse 2 asse 3 asse 3 asse 4 asse 4 asse 5 asse 5 asse 6 asse 6 asse 7 asse 7 asse 8 asse 8 asse 9 asse 9 AVTA CA TATAIA JAIA IA IT IA IAIA A JATIA IA 5 Siemens AG 465 981 7101 23 Edition 02 96 7 29 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options g69igr pgm File Edit x Show lines w Create lines Delete lines A N ID char B O C P c D Q Edit lt gt Overvi E R F S G T ew H U File name scousr00 gast struc Ink_igr makros v4 igr FB class 1 Select graph Class ID char A Z lt gt a z Class ID char IV Jw K X L Y M Z ass 1 c ass 1 ass 2 ass 2 ass 3 ass 3 ass 4 ass 4 ass 5 ass 5 ass 6 ass 6 ass 7 ass 7 ass 8 ass 8 ass 9 CEO ES h ECE I EAEE EEES NOA ES NE EE EO EE ao la ass 9
14. d for macros or blocks from user libraries The internal graphics of the function blocks are held in their own internal graphics libraries A host internal graphics library can be created for each block library and for macros It is possible to differentiate between individual SIMADYN versions even here 1 5 6 1 Library Names The names ofthe internal graphics libraries are generated according to the following pattern D foxxxx vy igr for internal graphics of function block libraries D macros vy igr for internal graphics of macros where fbxxxx is the name of the associated block library vy the version of the library Examples D The internal graphics library for the block library FBA123 from version 4 2 must receive the name f5a123 v4 igr D The internal graphics library for the block library FBSLO3 from version 3 2 must receive the name fbsl03 v3 igr The function packet editor searches for internal graphics libraries in the directories D HOME struc Ink igr The user can insert his own internal graphics libraries here D HOME struc Ink font The internal graphics libraries supplied with the STRUC installation are inserted here These libraries should not be modified Note HOME designates the users home directory Siemens AG 465 981 7101 23 Edition 02 96 7 17 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 5 6 2 Block Classes and Identifier Characters Each funct
15. e function File Load prompts whether the modified library should first be saved before the new library is loaded 7 22 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options a Filter scousrooigaststucinkignigr igr igr Directories Dateien struc Ink_igr A fba123 v4 igr struc Ink gr Vi Auswahl scousr00 gast struc Ink_igr makros v4 igr OK Filter Abbrechen Pen Filter scousrooigaststucink inion igr igr Directories Files struc Ink_igr A fba123 v4 igr struc lnk igr V Selection scousr00 gast struc Ink_igr macros v4 igr Diagram 1 20 File Selection Window When Loading an Internal Graphics Library The panels Directories of the selection window requires the selection ofa directory in which the internal graphics library is located The selection is implemented by clicking on the corresponding entry with the left hand mouse key and subsequently activating the Filter button or simply double clicking the desired entry If the directory has been selected then the desired internal graphics library is selected in the panel Files and the window exited with the OK button The total path name is displayed in the panel Selection Entries are also possible into this panel Loading can be aborted by activating the Cancel button File Save Siemens AG 465 981 7101 23 Edition 02 96 7 23 SIMA
16. ected Master or Processor Program AUTOCOMP Selected PN This function is only active i e the text of the sub menu is not ghosted when a processor program is selected If no processor program is selected then the text of the sub menu is ghosted This function compiles the master program if not compiled yet all function packets of the selected processor program and the selected processor program An error window Diagram 1 5 is popped onto screen when errors occur during the compilation The compilation errors in the master programs function packets or processor programs are listed with the corresponding number of detected error and warning messages FP COP TEST aborted Diagram 1 5 Error Window in AUTOCOMP 7 4 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options AUTOCOMP Selected MP This function is only active i e the text of the sub menu is notghosted when a master program is selected If no master program is selected then the text of the sub menu is ghosted This function compiles the master program all function packets and all processor programs An error window Diagram 1 5 is popped onto screen when errors occur during compilation The window displays the compilation errors in the master programs function packets or processor programs with a listing of the corresponding number of error and warning messages
17. entry content will have causal effects in the application programs IBS G down load such that certain SIMADYN D processor utilities seem not to be accessible Application programs usually wait to see if the utility will actually connect This can cause an accumula tion of these wait times during start up into considerable delays until the missing utility is detected and processed by the application program Even when these types of errors do not lead to system crashes care should be taken when setting parameters in the tables Example Diagram 7 30 shows a somewhat complex example for a window Select Communication Island As you can see the SIMADYN D equipment consists of 6 islands MPA INSELB INSELC MPD INSELE and INSELF The individual islands MPD INSELE and INSELF can be accessed via the SINEC H1 bus under the specified Ethernet address The CP1411 interface H1 is utilized for this purpose The utilities in the processor in the island INSELF can be accessed via the routing SIMADYN D network whereas the islands MPD or INSELE are interconnected via fixed links direct or peer to peer SIMADYN D network 7 34 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual Master Program MPA MPA020 MPA050 MPA090 MPA120 MPB030 MPB060 MPB100 MPB130 MPC040 MPB030 7 Compiler Prom Versions Libraries Options Define Communication Islands Isla
18. er programs or function packets with the number of detected blocks marked as faulty with Remark Ifthe libraries have been modified and no version update is carried out then the remark Version Incompatible is displayed when the listeditor is invoked If the libraries have only one release modification then an additional promptis displayed Version Update Y N If this promptis acknowledged with Y then a version update is carried out before invoking the editor If this promptis acknowledged with N then no version update is carried outand the MP FP can only be displayed butnot modified orthe listeditor can possibly be immediately aborted If the version is modified then only an up wards compatible up date version is possible i e system software i e V400 V420 If however the version has been changed then the remark Version Update Not Possible is displayed and the MP FP can only be displayed but not modified or the list editor can possibly be immediately aborted If the libraries have been modified and no version update has been carried out then no version update is forced when the graphics function packet editor is invoked The editor prevents blocks being inserted into the function packet from the library in question Siemens AG 465 981 7101 23 Edition 02 96 7 11 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options VERSION Version Matching Selected MP This function
19. gram directory atthe operating sys tem shell in which a function packetofthe same name already exists Therefore please check whether a function packet of the same name already exists before implementing a copy procedure When the answer is Yes then rename ofp or erase Compilation procedure messages are displayed in the window Message Output Basic Dialog FP COMP Selected Macro The selected macro is compiled using this function The function is immediately implemented i e no further prompting occurs Remark Only when a macro has been compiled can the function packet in which the macro is utilized be compiled Configuring errors with regard to the SIMADYN D regulations are detected by the compiler and the number of Errors and Warnings reported The FP EDIT must be re invoked to correct the errors Macros with errors or uncompiled macros are saved as umk 7 2 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options An error free compiled macro is saved as cmk Remark The STRUC compilation will not be correct when umk and cmk extensions of a macro name exists simulta neously This can occurwhen a macro is copied into a sub directory atthe operating systemhell in which a macro ofthe same name already exists Therefore please check whether a macro ofthe same name exists before starting the copying procedure If the answer is Yes t
20. hen rename omk or erase 1 1 3 PN COMP Compile Processor Program This function is only active i e the text in the sub menu is notghosted when a processor program is selected Ifno processor program is selected then the text in the sub menu is ghosted MPFP LIBS S AA PN COMP selekt Prozesso Beschaef gt E Bitte warten PN COP D01 P1 S zl MPFP LIBS yea PN COMP Selected PN Buy E Please wait PN COP D01 P1 E ES m Diagram 1 3 Compile Processor Program PN COMP Selected PN The selected processor program is compiled using this function The function is immediately started i e no further prompts are made The corresponding error window is popped onto screen if errors occur during compilation The window Message Output Basic Dialog displays the compilation process messages Siemens AG 465 981 7101 23 Edition 02 96 7 3 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 1 4 AUTO COMP Compile Selected Master or Processor Program E 3j MP PNI PNI Ansicht Makros IN po selekt MP alle Makros r Beschaeftigt l pee selekt PN selekt Makrounterverzeichnis AUTO COP MP v4_mp3 PN D01 P1 FP test L Abbrechen PN PN View Macros RN AUTOCOMP All Macros Selected Macro Subdirectory C Selected MP Selected PN AUTO COP MP v4_mp3 PN D01 P1 FP test Cancel En Diagram 1 4 Compile Sel
21. iertes MP Proj Betriebssystem selektiertes PN P32 Proj Betriebssystem selektiertes MP Reset MP DOD View Macros selected processor erase modification memory P32 erase modification memory P32 erase modification memory P16 erase modification memory P16 download gt Configuring selected PN P32 Configuring selected MP Conf toperating system selected PN P32 Conf toperating system selected MP Reset MP Diagram 1 7 Download PROG Download Configuring selected PN P32 Configuring selected MP The functions Download Configuring selected PN P32 or Download Configuring selected MP initiates a download of the configuring software of a P32 PN or all P32 PN s of a Master program A prompt will be displayed before the actual start to acknowledge whether the download to the selected processor should really be started Siemens AG 465 981 7101 23 Edition 02 96 7 7 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options u re In Projektierung selektiertes PN P32 1 MP Name tbr2 Prozessorname D08 P2 OK Abbrechen ed m Configuring selected PN P32 1 MP name tbr2 Processor name D08 P2 OK Cancel Diagram 1 8 Download Configuring selected PN Select Cancel to return to the basic dialog The download is started by selecting OK The following window is popped onto screen during the download procedure and contains informatio
22. ion block of a block library is allocated its internal graphics using the block class 1 9 and an identifier character a z or A Z An internal graphics library can therefore contain up to 52 individual internal graphics per block class The function blocks from the standard library are divided into the following block classes review Technical Description Standard Function Blocks P16 P32 Class 1 Control Blocks Class 2 Power Converter Specific Blocks Class 3 Arithmetic Blocks Class 4 Logic and Switching Blocks Class 5 Input Output Blocks Class 6 Communication Blocks Class 7 Conversion Blocks Class 8 Service Diagnostic Blocks Class 9 SpecialCommunications and Message Blocks The definition ofblock class and internal graphics identifier character is implemented for userfunction blocks in a user block generator It is recommended to maintain as far as practical the scheme utilized for the standard function blocks ITODOO TOD 0 00 Macros are allocated the block class 1 The internal graphics identifier character can be configured during the processing ofthe macro 1 5 6 3 Files of an Internal Graphics Library The following files are inserted in each internal graphics library foxxxx vy igr D A file foxxxx vy igr D Files foxxxx vy bstz for each block class z for which internal graphics are defined in the library 1 5 6 1 Layoutofan Internal Graphic The individual internal graphics c
23. is only active i e the text ofthe sub menu is notghosted when a master program is selected If no master program is selected then the text of the sub menu is ghosted This function implements a version update for the selected master program file VERSION Version Matching Selected FP This function is only active i e the text of the sub menu is notghosted when a function packet is selected If no function packet is selected then the text of the sub menu is ghosted This function implements a version update for the selected function packet file VERSION Version Matching All FP of PN This function is only active i e the textofthe sub menu is notghosted when a processor program is selected Ifno processor program is selected then the text of the sub menu is ghosted This function implements a version update for all function packets of the selected processor program VERSION Version Matching All FP and MP This function is only active i e the text ofthe sub menu is notghosted when a master program is selected If no master program is selected then the text of the sub menu is ghosted This function implements a version update for the selected master program and all function packets within this selected master program VERSION Version Matching Selected Macro This function is only active i e the text ofthe sub menu is not ghosted when a macro is selected If no macro is selected then the text of the sub menu is ghos
24. library name to be selected in the panel Files ora new name to be entered in the panel Selection analogous to the fast selection during loading of an internal graphics library Warning If a library exists with the selected name then this will be over written without further prompting Siemens AG 465 981 7101 23 Edition 02 96 7 25 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options File Exit Neu Laden Speichern Speichern als New Load Save Save as Diagram 1 24 Exiting the Internal Graphics Editor This function exits the internal graphics editor The editor prompts whetherthe currently processed library should be saved first 1 5 8 2 The Edit Menu The edit menu contains functions for deleting and copying the currently processed internal graphic Edit Cut Diagram 1 25 Cut Internal Graphic and Insert into the Data Bin The function Edit Cut deletes the current internal graphic and inserts it into the data bin Edit Copy Diagram 1 26 Copy the Internal Graphic into the Data Bin The function Edit Copy inserts a copy ofthe current internal graphic into the data bin 7 26 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options Edit Paste Diagram 1 27 Extract Internal Graphic from Data Bin The function Edit Paste inserts the conte
25. me tbr2 Processor name D08 P2 Cause Memory board write protected Repeat Cancel Diagram 1 10 Error Window The download can be repeated after the occurrence of an error Repeat or terminated Cancel It should also be noted that due to the interrupted download caused by the error the memory contents can possibly be inconsistent and that no reset is to be activated PROG Download Conf Operating System selected PN P32 Conf Operating System selected MP The functions Download Conf Operating System selected PN P32 or Download Conf Operating System selected MP initiates a download ofthe complete program configuring software and Operating system of a P32 PN or all P32 PN s of a Master program The subsequent dialog sequencing is the same as the functions Download Configuring selected PN P32 or Download Configuring selected MP PROG Download Reset MP The function Download Reset MP actives a rack reset This function will also promptfor a repeated intention to reset the rack 7 10 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 3 VERSION Version Matching FP Transformation P16 gt P32 Ansicht Makros VERSION VERSION Versionsanpassung Versionsanpassung Anwenderdaten Di selektiertes Makro selektiertes Makrounterverzeichnis DI selektiertes selektierte
26. n P16 View Macros l PROG Selected PN P16 Erase Modification Memory P16 Erase Modification Memory P32 Erase Modification Memory P32 Erase Modification Memory Diagram 1 6 Load Program Memory Sub Module PROG Selected PN The selected processor program is loaded into a memory sub module using this function An acknowledge window is popped onto screen if either no program memory sub module is installed or a program memory sub module of an incorrect type has been installed when this function is invoked Install Module If the program memory sub module of the type MS4x has not had its memory erased with UV light then an acknowledge window is also popped onto screen Module Not Erased Erase Attribute Memory PROG P16 Erase Modification Memory P32 Erase Modification Memory The functions PROG P16 Erase Modification Memory or P32 Erase Modification Memory erases the modifiable memory area of a program memory sub module for P32 or P16 processors The function is immediately implemented i e no further prompting occurs 7 6 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 2 2 Download Ansicht Makros Selektiertes PN P32 Aenderungsspeicher loeschen P32 Aenderungsspeicher loeschen P16 Aenderungsspeicher loeschen P16 Aenderungsspeicher loeschen Downl oad gt Projektierung selektiertes PN P32 Projektierung selekt
27. n regarding the progress ofthe load 7 8 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options EE MP Name tbr2 Speicher kByte Ladefortschritt belegt maximal in D08 P2 648 2048 28 PN Name ResetMP Schliessen Abbrechen eet In Download running 1 MP name tbr2 Memory kByte Load progress used maximum in 96 D08 P2 648 2048 28 PN name Reset mp Close Cancel E E Diagram 1 9 Information Window during the Download Procedure The current progress ofthe load procedure is displayed on screen in The Reset Close and Cancel buttons ofa processorare switched inactive during an active load The procedure can be cancelled between the loads of individual processors the Cancel button is active when loading an MP several processors Reset the rack Reset MP or exit the procedure Close after completion of the download When an error occurs during the download procedure then an error window is popped onto screen that mustbe acknowledged Siemens AG 465 981 7101 23 Edition 02 96 7 9 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options zu m es u un i Download verlief fehlerhaft Reset MP nicht ausl sen MP Name tbr2 Prozessorname D08 P2 Ursache Speicherkarte schreibgeschuetzt Wiederholen Abbrechen 4 Download sequencing fault Do not activate MP reset MP na
28. nd NSELB Reference Channel Diagram 7 28 Define Communication Islands Edition 02 96 7 Compiler Prom Versions Libraries Options Select Communication Island Addressing IslandNetw C H Ethernet Addr CQB j fD KQH j f NSELBj f NSELCj f NSELEj f NSELFj f MA f Baud Rate MPB j f MPG j f 300 MP H f 600 MQA f 1200 MQC f 2400 MQD f 4800 MQF f 9600 MQG f 19200 ZQE f Diagram 7 29 Select Communication Island 7 36 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options Select Communication Island Addressing IslandNetw C H Ethernet Addr NSELBj INSELCK NSELEj NSELFK MPA j MPD Baud Rate 300 600 1200 2400 4800 9600 19200 Diagram 7 30 Select Communication Island Siemens AG 465 981 7101 23 Edition 02 96 7 37 SIMADYN D STRUC G User manual
29. normally also the error itself can be exactly reproduced with the aid of this error image This is the prerequisite for the fastest possible error analysis and resolution The error image contains Implemented editor commands and their effects since invoking STRUC G The last selected function packet and master program file Page lists created by the editor for the currently selected function packet Cross reference lists of the processor program created by the compiler The core dump file after a program plunge Create Error Window An error image can be created by invoking the function OPTIONS Save Error Image after exiting the graphics function packet or master program editor The error image is inserted as a file in the directory HOME struc Ink tmp fel An information window containing the error image file names is displayed after the error image has been generated Ifthe function is invoked when a previous error image had already been saved then a dialog window is displayed containing the prompt to either overwrite the old error image or cancel the function Downloading the Error Image Save the error image file with Betrieb system commends on a DOS disc cd HOME struc Ink_tmp fel dos CA struc Ink_tmp fel gt copy a dos disc in Laufwerk a The data carrier should be sent together with the SIMADYN D Report to the SIMADYN D Hotline ASI1 V122 PTS The Error image is an archiv file With the following
30. nts ofthe data bin into the currentinternal graphic The data bin is not deleted such that this internal graphic can be inserted as often as required The instruction sequence Cut and Paste moves therefore an internal graphics symbol the sequence Copy and Paste duplicates it 1 5 9 The Information Strip of the Internal Graphics Editor The information strip ofthe editor Diagram 1 28 displays the file name ofthe processed internal graphics library as well as the block class and the identifier character ofthe current internal graphic The internal graphics processed in the working area during the editors editing mode is displayed here in normal size Dateiname scousr00 gast struc Ink_igr makros v4 igr Klasse Zeichen Bausteinklasse und Kennbuchstabe Dateiname der bearbeiteten aktuelle Innengrafik der aktuellen Innengrafik Innengrafik Bibliothek File name scousrO0 gast struc Ink igr macros v4 igr FB class ID char Function Block Class and ID Character of the File Name ofthe Internal Current Internal Graphic Current Internal Graphic Graphic Library Diagram 1 28 The Information Strip 1 5 10 The Function Strip of the Internal Graphics Editor The function strip of the editor Diagram 1 29 contains the dialog elements for selecting the current internal graphic and for selecting the processing function Siemens AG 465 981 7101 23 Edition 02 96 7 27 SIMADYN D STRUC G User man
31. ommunication activity several SIMADYN racks can be interconnected with one another via the rack link to create a SIMADYN D network review SIMADYN D user manual Communication chapter 25 Network This type of interconnection of racks and even an individual rack is designated as SIMADYN D communication island where it can be accessed externally via at least one communication connection i e SINEC H1 bus serial DUST1 connection STRUC G functions i e Function Packet Editor IBS G address these islands via a name the island name The allocation of the rack or a master program to an island is implemented via the window Define Communication Island see Diagram 7 28 that is opened by the STRUC G function of the same name An island name and a reference channel number for each master program of the current project can be specified in this window The reference channel name is utilized to shift the utilities channel numbers on the individual racks with respect to one another when communication is taking place via a peer to peer SIMADYN D network review details in chapter 8 Configuring Rules This value should be 0 in all other cases The default island name is the master program name the reference channel number is initialized with 0 To modify the allocation of a particular master program select the master program in the selection box using the scroll bar The selected data is repeated in 3 panels below the selecti
32. on box whereby the panels containing the island name and the reference channel number can be modified Actuate the Modify button to accept the data in the selection box after entering the desired allocation The OK button saves the selection box data for the project and returns to the basic dialog The Cancel button returns to the basic dialog without modifications being made 1 5 11 2 Select Communication Island The STRUC G functions Function Packet Editor IBS G and Download require the STRUC G processor to be connected with the configured SIMADYN D equipment via one of its serial interfaces or via the SINEC H1 bus At the equipment end one or several CSH11 boards are required when the SINEC H1 link is utilized or one CS7 SS4 combination when a serial link is utilized Any of these peripheral boards will permit the access to a so called island An island is a single rack or a group of several racks that are interlinked to a SIMADYN D network via a rack link see SIMADYN D user manual Communication chapter 25 Network The name of this type of island is specified by the function Define Communication Island see section 7 5 11 6 This function then defines which path the STRUC G processor takes to access the individual island in the SIMADYN D equipment After selection the window Select Communication Island is displayed Diagram 2 29 shows the layout of the window after it has been opened
33. onsist of 31 25 grid points Diagram 1 16 Symbols consisting of individual lines vector graphics are generated within this grid This permits internal graphics to be displayed on various output devices in any magnifying factor 7 18 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 25 Rp 31 Rasterpunkte 25 G P 31 Grid Points Diagram 1 16 Internal Graphics Symbol in the Grid 31 25 1 5 7 The Screen Window of the Internal Graphics Editor The screen window of the editor consists of D The menu bar D The information strip D The function strip and D a working area An overview mode of the editor permits all the internal graphics contained within the library to be displayed Individual internal graphics are processed in the working area in the editing mode see Diagram 1 31 Diagrammm 7 13 shows the screen window in the overview mode after invoking the editor No internal graphics library has been loaded as yet for processing Siemens AG 465 981 7101 23 Edition 02 96 7 19 SIMADYN D
34. ry FBSLO3 P16 fosl03 m86 P32 fbsl03 mr3 fbsl03 186 fbsl03 a fesl03 186 fesl03 a If for example after the installation of a new user library the library name fbaxxx does not appear in the selection window of the available libraries then individual files are possibly missing This can be checked with the UNIX command Is al HOME struc ver v400 f axxx Clicking on the OK button exits the selection function 7 14 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 5 OPTIONS Address Book FP UN Lock Save Error Image Internal Graphics Editor Communication Island Ansicht Makros OPTIONEN OPTIONEN Adressbuch Fehlerbild abspeichern FP Lock Innengrafikeditor FP Unlock Fehlerbild abspeichern Innengrafikeditor View Macros OPTIONS OPTIONS Log File Address Book Save Error Image FP Lock FP Unlock Save Error mage Editor for Internal Graphics Editor for Internal Graphics Diagram 1 14 OPTIONS 15 1 Log File The errormessage created in COMP functions and the listen editor invokes are collected in an log file This log file can be loaded with the function OPTIONS Log File View and erased with the function OPTIONS Log File Delete This function is only active i e the text of the sub menu is not ghosted when a function packet is selected If no function packet is selected then the text of the sub men
35. s Anwenderdaten alle FPs des alle Makros aller Makrounterverz alle FPs und Hi View Macros Version Matching Selected MP Selected FP All FP of PN Selected Macro FP Transformation P16 lt gt P3 Selected Macro Subdirectory All Macros All FP and MP Diagram 1 11 Sub Menu Title Version Update A version update can be implemented using the function VERSION Version Matching A version update of the user data is necessary when either the release or the version of the standard or user libraries utilized in the configuring is modified or a macro utilized in a function packetis once again changed after already being invoked in a function packet If the layout visual structure of the corresponding block or macro has not been altered then it is automatically revised during the version update Blocks whose layout have changed such that no automatic version update is possible are flagged with and must be revised using the function Configure block SUBMSK in the function packet editor A layout modification can be New or deleted connectors Modification of the type of connector Block was deleted from the library The re compilation of the processor program is mandatory subsequentto a version update AUTOCOMP An error window review Diagram 1 5 is popped onto screen when errors occur during the version update The window contains a listing of the corresponding mast
36. ted This function implements a version update for the selected macro file using this function VERSION Version Matching Selected Macro Subdirectory This function is only active i e the text of the sub menu is notghosted when a macro sub directory is selected If no macro sub directory is selected then the text of the sub menu is ghosted This function implements a version update for all macros of the selected macro sub directory VERSION Version Matching All Macros This function is only active i e the text of the sub menu is not ghosted when the macro directory is selected This function implements a version update for all macros of the selected project VERSION FP Transformation P16 gt P32 The FP transformation is a special kind of version up date This function is only active i e the text of the sub menu is not ghosted when the function packet is selected If no funktion packetis selected then the text of the sub menu is ghosted If the selected processor is a P32 processor and the function packet is a P16 function packet then the function packet is transformed in a P32 function packet If the selected processor is a P16 processor and the function packet is a P32 function packet then the function packet is transformed in a P16 function packet function packet to a P32 function packet or a P32 function packet to a P16 function packet If the function packet that must be selected was created b
37. the routing SIMADYN D network then Network must also be selected for this communication island If the interface H1 is selected then the connection runs via the SINEC CP1411 board installed in the PC under this name The layers 1 to 4 of the SINEC H1 network are utilized for the protocol It is therefore possible to create several transport connections to various SINEC H1 network nodes i e also to SIMADYN D CSH11 boards Which island drives what SINEC H1 network node is defined in the column Ethernet Address of the Addressing panel The same Ethernet address must be entered here as has been defined at the connector MAA of the CSHII function block that initializes the CSH11 board of the corresponding island A selection in the S column must now take place in order to enable the node and therefore also the connection to the island for use by STRUC G This separate enable seems to be unnecessary at first sight It permits however only the really necessary interconnections to be activated Therefore less interconnections to the individual utilities need to be created at the start of applications i e IBS G which leads to shorter initialization times for the application If the processors of an island or their utilities are accessible via the routing SIMADYN D network then Network must be additionally selected for this island The specifications in the panel Baud Rate and in the column C can be ignored Errors in the window
38. u is ghosted 1 5 2 Address Book A directory of all connector addresses of the selected P32 processor program is created using this function This function is only active i e the text of the sub menu is not ghosted when a P32 processor is selected and a processor program does exist If this function is invoked fora P16 processor program then itwill abortwith an error message 15 3 FP Lock This function is only active i e the text of the sub menu is not ghosted when a function packet is selected If no function packet is selected then the text of the sub menu is ghosted This function disables the selected function packet for retro documentation A disabled function packetcannotbe loaded again from the binary file know how protection 1 5 4 FP Unlock This function is only active i e the text of the sub menu is not ghosted when a function packet is selected If no function packet is selected then the text of the sub menu is ghosted Siemens AG 465 981 7101 23 Edition 02 96 7 15 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options An FP lock disable is removed using this function 1 5 5 Save Error Image If errors have occurred in the graphics editor during the processing ofa master program or function packet then you should firstsave the corresponding error image and send itto your service center before re invoking the editor The configuring steps up to the occurrence ofthe error and
39. ual 7 Compiler Prom Versions Libraries Options Auswahl der Bearbeitungsfunktion Umschalten zwischen bersichts und Editiermodus n chste V ME n chste NN ee Zeichen selekt y Linie erzeugen Gross lt gt Klein sd m Linie anzeigen w Linie ee A Z lt gt a z Klasse ZZ nn Innengrafik V orhergehende Bausteinklasse Umschalten der bersicht Kennbuchstaben a z bzw A Z Selection ofthe Editor Function Switch Edit Overview Mode Next T Class Next iiu Graphic Select graph w Create lines Edit lt gt Overview m ID H Vv lines Delete lines A Z a z Class ID Previous Internal mnm Previous Block Class Switch ID Characters a z or A Z Diagram 1 29 The Function Strip 1 5 10 1 Selection Functions The selection functions are operated via buttons in the right hand section of the function strip Large lt gt Small This button switches between the overview mode Diagram 1 30 and the editing mode Diagram 1 31 ofthe editor The overview mode is utilized to selectthe internal graphic to be currently processed and the internal graphic to be deleted or copied using the Cut Copy Paste Mechanism The current internal graphic is framed within the working area The current internal graphic is processed in the editing mode A Z lt gt a z This button switches between the representation of the internal graphic with the identifying character a z and
40. y an older system software version then a version adaptaion is additionally carried out while the transformation If the maske layout of a transformed block has changed then this block is marked with as the version adaptation While projecting the block mustbe replaced with the function Configure Block SUBMSK 7 12 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 7 Compiler Prom Versions Libraries Options 1 4 LIBRARIES SelectLibraries Diagram 1 12 Select Libraries The library selection window is popped onto screen when this function is invoked The user can select three of the available libraries in addition to the standard block rack FBSLIB or the block library IBSLIB for configuring his project The standard library is always present even when no additional libraries have been selected Itis part of the STRUC scope of supply and cannot be modified Bibliotheken selektieren Grundsoftware GSW FB Bibliotheken Version Stand P16 P32 IB Bibliotheken Version Stand P16 BLSIB A frei J LI Cj ae n A frei j oO L a B frei oO Cl n n B frei LI DJ a C frei J LI Li n n C frei LI CJ Lox A Select Libraries 1 Basic Software GSW FB libraries Version Release P16 P32 IB libraries Version ReleaseP16 P32 A Empty LI DJ ae n A Empty L1 CL n B Empty O C2 n B Empty L OJ sa Ge Empty LI Li n n C Empty LI Li ca Diagram 1 13 Select Libraries Siemens AG 465 98